N994CF
1999 Raytheon Aircraft Company B300 standard FAA →
registration
- 1999
aircraft radio
2 past records
earlier registrations
1 past record
service difficulty reports
477 reports
- 21 Jan 2008
Frame, damaged
DURING A MAINT VISIT, FOUND MISDRILLED HOLES IN THE UPPER CARGO COMPT. FS 1340 AND L21R TO L21L, DAMAGE EXCEEDED LIMITATIONS IAW SRM. REMOVED DAMAGE, TREATED…
- 26 Jan 2005
Frame, damaged
DURING A MAINTENANCE VISIT, FOUND MISDRILLED HOLES IN THE UPPER CARGO COMPT FS 1220 AND L21R TO L21L, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED…
- 28 Apr 2000
Bulkhead, cracked
DURING A MAINTENANCE VISIT, FOUND A CRACK ON AFT PRESSURE BULKHEAD FRAME TOP ANGLE ON FR & BOTTOM OF FRAME Z + 43 X + 2 TO -2, DAMAGE EXCEEDED LIMITATIONS IAW…
- 28 Apr 2000
Bulkhead, cracked
DURING A MAINTENANCE VISIT, FOUND A CRACK ON AFT FRAME AFT PRESSURE BULKHEAD FRAME BOTTOM ANGLE ON FRAME & TOP ANGLE AT Z + 30 X -2 TO +4, DAMAGE EXCEEDED…
- 28 Apr 2000
Bulkhead, cracked
DURING A MAINTENANCE VISIT, FOUND A CRACK ON AFT FRAME AFT PRESSURE BULKHEAD FRAME Z + 18 X + 2 TO -2 TOP ANGLE OF FRAME, DAMAGE EXCEEDED LIMITATIONS IAW DC-8…
- 14 Apr 2000
Fitting, misdrilled
DURING A MAINTENANCE VISIT FOUND SEVERAL AREAS DRILLED IN THE CABIN L/H FLOOR BEAM ATTACH FITTING AT FS 580 AND L21L, DAMAGE EXCEEDED LIMITATIONS IAW DC-8…
- 13 Apr 2000
Structure, damaged
DURING A MAINTENANCE VISIT, ROBBED CARGO DOOR FOR AIRCRAFT N8079U, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8.…
- 12 Apr 2000
Seat Track, worn
DURING A MAINTENANCE VISIT, FOUND ELONGATED HOLES IN THE CABIN UPPER CARGO COMPT SEAT TRACK C5-R7, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE,…
- 12 Apr 2000
Cargo Track, damaged
DURING A MAINTENANCE VISIT, FOUND ELONGATED HOLES IN THE CABIN UPPER CARGO COMPT SEAT TRACK C8-R4, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE,…
- 12 Apr 2000
Cargo Track, damaged
DURING A MAINTENANCE VISIT, FOUND ELONGATED HOLES IN THE CABIN UPPER CARGO COMPT SEAT TRACK C5-R2, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE,…
- 12 Apr 2000
Cargo Track, damaged
DURING A MAINTENANCE VISIT, FOUND ELONGATED HOLES IN THE CABIN UPPER CARGO COMPT SEAT TRACK C7-R5, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE,…
- 12 Apr 2000
Seat Track, damaged
DURING A MAINTENANCE VISIT FOUND ELONGATED HOLES TO THE CABIN UPPER CARGO BAY. SEAT TRACK C8-R5, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE,…
- 12 Apr 2000
Seat Track, damaged
DURING A MAINTENANCE VISIT FOUND ELONGATED HOLES IN THE CABIN UPPER CARGO COMPT. SEAT TRACK C11-R1, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE.
- 12 Apr 2000
Seat Track, damaged
DURING A MAINTENANCE VISIT FOUND ELONGATED HOLES IN THE CABIN UPPER CARGO COMPT. SEAT TRACK C-13 R3, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE,…
- 12 Apr 2000
Seat Track, damaged
DURING A MAINTENANCE VISIT FOUND ELONGATED HOLES IN THE CABIN UPPER CARGO COMPT. SEAT TRACK C-10, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE,…
- 12 Apr 2000
Seat Track, damaged
DURING A MAINTENANCE VISIT FOUND ELONGATRED HOLES IN THE CABIN UPPER CARGO BAY. SEAT TRACK C11, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE,…
- 12 Apr 2000
Cargo Track, damaged
DURING A MAINTENANCE VISIT FOUND AREAS OF TRIM AT MULTIPLE LOCATIONS THROUGHOUT AIRCRAFT LWR. EDGE OF LWR. VERTICAL FLANGE OF CABIN CARGO TRACK, DAMAGE…
- 12 Apr 2000
Splice, mislocated
DURING A MAINTENANCE VISIT FOUND THAT THE CABIN FLOORBOARD SPLICE LOCATIONS ARE NOT PER AVAILABLE STC. DRAWINGS. CABIN FLOORBOARD SPLICE LOCATIONS ARE…
- 12 Apr 2000
Splice, mislocated
DURING A MAINTENANCE VISIT FOUND THAT THE CABIN CARGO TRACK SPLICE LOCATIONS ARE NOT PER AVAILABLE STC. DRAWINGS. EXISTING CABIN CARGO TRACK SPLICE LOCATIONS…
- 12 Apr 2000
Seat Track, broken
DURING A MAINTENANCE VISIT FOUND THE CABIN UPPER CARGO COMPT. SEAT TRACK C11-R3 BROKEN, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA…
- 12 Apr 2000
Seat Track, damaged
DURING A MAINTENANCE VISIT FOUND ELONGATED HOLES IN THE CABIN UPPER CARGO COMPT SEAT TRACK C12-R4, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE,…
- 12 Apr 2000
Seat Track, damaged
DURING A MAINTENANCE VISIT FOUND ELONGATED HOLES IN THE CABIN UPPER CARGO COMPT. SEAT TRACK C12-R4, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE,…
- 12 Apr 2000
Seat Track, damaged
DURING A MAINTENANCE VISIT FOUND ELONGATED HOLES IN THE CABIN UPPER CARGO COMPT. SEAT TRACK C5-R3, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE,…
- 12 Apr 2000
Seat Track, gouged
DURING A MAINTENANCE VISIT FOUND SEVERAL AREAS GOUGED IN THE CABIN UPPER CARGO COMPT. SEAT TRACK C13-R1, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED…
- 12 Apr 2000
Seat Track, damaged
DURING A MAINTENANCE VISIT FOUND ELONGATED HOLES IN THE CABIN UPPER CARGO COMPT SEAT TRACK C7-R3, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE,…
- 12 Apr 2000
Seat Track, damaged
DURING A MAINTENANCE VISIT FOUND ELONGATED HOLES IN THE CABIN UPPER CARGO COMPT SEAT TRACK C7-R6, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE,…
- 12 Apr 2000
Seat Track, damaged
DURING A MAINTENANCE VISIT FOUND ELONGATED HOLES IN THE CABIN UPPER CARGO COMPT SEAT TRACK C9-R5, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE,…
- 12 Apr 2000
Seat Track, gouged
DURING A MAINTENANCE VISIT FOUND SEVERAL GOUGED AREAS IN THE CABIN UPPER CARGO COMPT. SEAT TRACK C8-R1, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED…
- 12 Apr 2000
Seat Track, damaged
DURING A MAINTENANCE VISIT FOUND ELONGATED HOLES IN THE CABIN UPPER CARGO COMPT SEAT TRACK C10-R5, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE,…
- 12 Apr 2000
Seat Track, damaged
DURING A MAINTENANCE VISIT FOUND ELONGATED HOLES IN THE CABIN UPPER CARGO COMPT SEAT TRACK C8-R1, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE,…
- 12 Apr 2000
Seat Track, damaged
DURING A MAINTENANCE VISIT FOUND ELONGATED HOLES IN THE CABIN UPPER CARGO COMPT SEAT TRACK C10-R3, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE,…
- 4 Apr 2000
Seat Track, misdrilled
DURING A MAINTENANCE VISIT, FOUND MISDRILLED HOLES IN THE CABIN UPPER CARGO COMPT SEAT TRACK C2-R1, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE,…
- 4 Apr 2000
Seat Track, worn
DURING A MAINTENANCE VISIT, FOUND ELONGATED HOLES IN THE CABIN UPPER CARGO COMPT SEAT TRACK C1-R2, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE,…
- 4 Apr 2000
Seat Track, damaged
DURING A MAINTENANCE VISIT, FOUND ELONGATED HOLES IN THE MAIN CABIN UPPER CARGO COMPT SEAT TRACK C4-R6, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED…
- 4 Apr 2000
Seat Track, damaged
DURING A MAINTENANCE VISIT, FOUND ELONGATED HOLES IN THE UPPER CARGO COMPT SEAT TRACK C4-R3, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED…
- 4 Apr 2000
Seat Track, damaged
DURING A MAINTENANCE VISIT, FOUND HOLES ELONGATED IN THE CABIN UPPER SEAT TRACK C4-R4, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND…
- 4 Apr 2000
Seat Track, worn
DURING A MAINTENANCE VISIT, FOUND A WORN SEAT TRACK C2-R3 IN THE UPPER CARGO COMPT, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND…
- 4 Apr 2000
Seat Track, damaged
DURING A MAINTENANCE VISIT FOUND ELONGATED HOLES IN THE CABIN UPPER CARGO BAY. SEAT TRACK C6-R6, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE,…
- 4 Apr 2000
Seat Track, misdrilled
DURING A MAINTENANCE VISIT, FOUND MISDRILLED HOLES TO THE SEAT TRACK C1-R4 IN THE UPPER CARGO COMPT. DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE,…
- 31 Mar 2000
Skin, damaged
DURING A MAINTENANCE VISIT, FOUND TWO SCREWS NOT INSTALLED IN RT WING L/E BETWEEN STA XFS 26.250 AND 63.750 (EO), DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.…
- 29 Mar 2000
Web, cracked
DURING A MAINTENANCE VISIT, FOUND A CRACK TO THE WEB AT THE WHEEL WELL IB SIDE AT STA 900 Z = -60, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE,…
- 28 Mar 2000
Floorboard, misdrilled
DURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES ON FLOOR PLANK (C1-R10), DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED…
- 28 Mar 2000
Floorboard, misdrilled
DURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES THROUGHOUT FLOOR PLANK/PANEL (C12-R10), DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE,…
- 28 Mar 2000
Floorboard, misdrilled
DURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN FLOOR PLANK C15-R9, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW…
- 28 Mar 2000
Floorboard, misdrilled
DURING A MAINTENANCE VISIT FOUND NUMEROUS DRILLED HOLES ON FLOORBOARD C9 TO R13, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW…
- 28 Mar 2000
Web, cracked
DURING A MAINTENANCE VISIT, FOUND A CRACK TO THE WEB IN THE LT WHEEL WELL IB SIDE STA 900 Z = -60, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE,…
- 28 Mar 2000
Floorboard, misdrilled
DURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN FLOORBOARD C15-R4, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8…
- 28 Mar 2000
Floorboard, misdrilled
DURING A MAINTENANCE VISIT FOUND NUMEROUS DRILLED HOLES IN FLOORBOARD C1-R8, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8…
- 28 Mar 2000
Floorboard, misdrilled
DURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN FLOORBOARD C6-R3, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8…
- 28 Mar 2000
Floorboard, misdrilled
DURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN FLOOR PANEL C15-R6, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW…
- 28 Mar 2000
Floorboard, misdrilled
DURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN FLOOR PANEL C14-R8, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW…
- 28 Mar 2000
Floorboard, misdrilled
DURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN THE FLOOR PANEL C14-R6, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW…
- 28 Mar 2000
Floorboard, misdrilled
DURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN FLOOR PANEL C14-R4, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW…
- 28 Mar 2000
Floorboard, misdrilled
DURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN FLOOR PANEL C5-R3, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8…
- 28 Mar 2000
Floorboard, misdrilled
DURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN FLOOR PANEL C5-R6, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8…
- 28 Mar 2000
Floorboard, misdrilled
DURING A MAINTENANCE VISIT, FOUND A LARGE HOLE 9 INCHES FROM EDGE, 5 INCHES FROM OUTBOARD EDGE C12-R6, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED…
- 28 Mar 2000
Floorboard, misdrilled
DURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES THROUGHOUT FLOOR PANEL C2-R11, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA…
- 28 Mar 2000
Floorboard, misdrilled
DURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES THROUGHOUT FLOOR PANEL C2-R1, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA…
- 28 Mar 2000
Floorboard, misdrilled
DURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES ON FLOOR PANEL C29-R9, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW…
- 28 Mar 2000
Floorboard, misdrilled
DURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN FLOOR PANEL C15-R5, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW…
- 28 Mar 2000
Floorboard, misdrilled
DURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN FLOOR PANEL C6-R5, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8…
- 28 Mar 2000
Floorboard, misdrilled
DURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN FLOOR PANEL C1-R1, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8…
- 28 Mar 2000
Floorboard, misdrilled
DURING A MAINTENANCE VISIT FOUND NUMEROUS DRILLED HOLES IN FLOOR PANEL C1-R13, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8…
- 28 Mar 2000
Floorboard, misdrilled
DURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN FLOOR PANEL C2-R12, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW…
- 28 Mar 2000
Floorboard, misdrilled
DURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN FLOOR PANEL C2-R8, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8…
- 28 Mar 2000
Floorboard, misdrilled
DURING A MAINTENANCE VISIT, FOUND NUMEROUS HOLES DRILLED IN FLOOR PANEL C2-R2, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8…
- 28 Mar 2000
Floorboard, misdrilled
DURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN FLOOR PANEL C1-R11, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW…
- 28 Mar 2000
Floorboard, misdrilled
DURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES THROUGHOUT FLOOR PANEL C5-R7, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA…
- 28 Mar 2000
Floorboard, misdrilled
DURING A MAINTENANCE VISIT FOUND NUMEROUS DRILLED HOLES THROUGHOUT FLOOR PANEL C6-R6, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA…
- 28 Mar 2000
Floorboard, misdrilled
DURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES THROUGHOUT FLOOR PANEL C2-R10, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA…
- 28 Mar 2000
Floorboard, misdrilled
DURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN FLOOR PANEL C8-R9, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8…
- 27 Mar 2000
Floorboard, misdrilled
DURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES THROUGHOUT FLOOR PLANK/PANEL (C1-R7) 12 INCHES FROM EDGE FLANGE, DAMAGE EXCEEDED LIMITATIONS IAW DC-8…
- 27 Mar 2000
Floorboard, misdrilled
DURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN FLOOR PLANK C3-R2, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8…
- 27 Mar 2000
Floorboard, misdrilled
DURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN FLOOR PLANK (C8-R8), DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW…
- 27 Mar 2000
Floorboard, misdrilled
DURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES ON FLOORBOARD C12-R4, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8…
- 27 Mar 2000
Floorboard, misdrilled
DURING A MAINTENANCE VISIT FOUND NUMEROUS DRILLED HOLES IN FLOORBOARD C5-R13, DAMAGED EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8…
- 27 Mar 2000
Floorboard, misdrilled
DURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES THROUGHOUT FLOOR PANEL C2-R7, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA…
- 27 Mar 2000
Floorboard, misdrilled
DURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES THROUGHOUT FLOOR PANEL C2-R5, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA…
- 27 Mar 2000
Floorboard, misdrilled
DURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES THROUGHOUT FLOOR PANEL C9-R2, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA…
- 27 Mar 2000
Floorboard, misdrilled
DURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES ON FLOOR PANEL C1-R3, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8…
- 27 Mar 2000
Floorboard, misdrilled
DURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN FLOOR PANEL C5-R10, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW…
- 27 Mar 2000
Floorboard, misdrilled
DURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN FLOOR PANEL C1-R12, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW…
- 27 Mar 2000
Structure, cracked
DURING A MAINTENANCE VISIT, FOUND A CRACK BEHIND LT NOSE LANDING GEAR DOOR ON FUSELAGE, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND…
- 27 Mar 2000
Floorboard, misdrilled
DURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES ON FLOOR PANEL C5-R2, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8…
- 27 Mar 2000
Floorboard, misdrilled
DURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES ON FLOOR PANEL C4-R7, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8…
- 27 Mar 2000
Floorboard, misdrilled
DURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES ON FLOOR PANEL C5-R8, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8…
- 27 Mar 2000
Floorboard, misdrilled
DURING A MAINTENANCE VISIT, FOUND NUMEROUS HOLES THROUGHOUT FLOOR PANEL C12-R11, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW…
- 27 Mar 2000
Floorboard, misdrilled
DURING A MAINTENANCE VISIT, FOUND NUMEROUS HOLES ON FLOOR PANEL C12-R13, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM…
- 26 Mar 2000
Floorboard, misdrilled
DURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN FLOOR PLANK (C9-R3), DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW…
- 26 Mar 2000
Floorboard, misdrilled
DURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES THROUGHOUT FLOOR PLANK/PANEL (C9-R6), DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE,…
- 26 Mar 2000
Floorboard, misdrilled
DURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN THE FLOORBOARD C14-R7, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW…
- 26 Mar 2000
Floorboard, misdrilled
DURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN FLOOR PANEL C13-R6, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW…
- 26 Mar 2000
Floorboard, misdrilled
DURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN FLOOR PANEL C8-R2, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8…
- 26 Mar 2000
Floorboard, misdrilled
DURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN FLOOR PANEL C5-R5, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8…
- 26 Mar 2000
Floorboard, misdrilled
DURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN FLOOR PLANK C8-R11, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW…
- 26 Mar 2000
Floorboard, misdrilled
DURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN FLOOR PANEL C2-R9, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8…
- 26 Mar 2000
Floorboard, misdrilled
DURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN THE FLOOR PANEL C12-R3, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW…
- 26 Mar 2000
Floorboard, misdrilled
DURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES C2-R12, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8.…
- 26 Mar 2000
Floorboard, misdrilled
DURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES THROUGH FLOOR PANEL, LARGE HOLE WITH CRACK AT ABOUT CENTER OF FLOOR PANEL AND LARGE DENT WITH CRACK…
- 26 Mar 2000
Floorboard, misdrilled
DURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES THROUGHOUT FLOOR PANEL O1-R6, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA…
- 25 Mar 2000
Floorboard, misdrilled
DURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES THROUGHOUT FLOOR PLANK/PANEL (C2-R3), DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE,…
- 25 Mar 2000
Floorboard, misdrilled
DURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN FLOORBOARD C2-R5, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8…
- 25 Mar 2000
Floorboard, misdrilled
DURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN FLOOR PANEL C15-R3, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW…
- 25 Mar 2000
Floorboard, misdrilled
DURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN FLOOR PANEL C8-R4, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8…
- 25 Mar 2000
Floorboard, misdrilled
DURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN FLOOR PANEL C6-R13, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW…
- 25 Mar 2000
Floorboard, misdrilled
DURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN FLOOR PANEL C15-R10, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW…
- 25 Mar 2000
Floorboard, misdrilled
DURING A MAINTENANCE VISIT, FOUND DRILLED HOLES CLUSTERED TOGETHER C14-R9, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM…
- 25 Mar 2000
Floorboard, misdrilled
DURING A MAINTENANCE VISIT, FOUND WORN DRILLED HOLE AREA ON FLOOR PANEL ALSO NUMEROUS DRILLED HOLES ON FLOOR PANEL C12-R1, DAMAGE EXCEEDED LIMITATIONS IAW…
- 25 Mar 2000
Floorboard, misdrilled
DURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES THROUGHOUT C1-R6, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM…
- 25 Mar 2000
Floorboard, misdrilled
DURING A MAINTENANCE VISIT FOUND NUMEROUS HOLES IN FLOOR PANEL C9-R8, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM…
- 21 Mar 2000
Panel, cracked
DURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO LT WING LWR WING PANEL AT STA XRS 351, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED…
- 21 Mar 2000
Frame, misdrilled
DURING A MAINTENANCE VISIT FOUND DOUBLE DRILLED AT STA 300 AND L2L TO L4L, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA…
- 17 Mar 2000
Skin, damaged
DURING A MAINTENANCE VISIT FOUND TEN ELONGATED SCREW HOLES IN THE UPPER AFT MOUNTING NR 1 STUB WING AT XS 520 TO XFS 566.250, DAMAGE EXCEEDED LIMITATIONS IAW…
- 17 Mar 2000
Skin, cracked
DURING A MAINTENANCE VISIT FOUND A CRACK EMANATING FROM A SCREW HOLE LT WING CENTER LE AT O/B SLOT LE AT STA XS 520, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.…
- 17 Mar 2000
Skin, cracked
DURING A MAINTENANCE VISIT FOUND AN ENLARGED AND ELONGATED SCREW HOLE ON THE LT WING O/B SLOT LE I/B END AT STA XS 520, DAMAGE EXCEEDED LIMITATIONS IAW DC-8…
- 17 Mar 2000
Structure, damaged
DURING A MAINTENANCE VISIT, FOUND ELONGATED SCREW HOLES LT WING IB LE LWR. SURFACE AT STA XFS 107 TO 113, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED…
- 17 Mar 2000
Stiffener, corroded
DURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE ON THE STIFFENER AROUND EXTERNAL POWER SOURCE WIRES AT STA 198 TO 204, RBL 69 TO 61, DAMAGE EXCEEDED…
- 14 Mar 2000
Floor Support, misdrilled
DURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN THE CABIN SUB FLOOR STA 225 CUSP TO CUSP, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED…
- 14 Mar 2000
Longeron, corroded
DURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO THE FUSELAGE AT STA 1500 TO 1520 AND LONGERON 24L, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED…
- 14 Mar 2000
Vane, delaminated
DURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO THE RT WING OB FLAP VANE BETWEEN CENTER AND OB HINGE, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED…
- 8 Mar 2000
Floorbeam, misdrilled
DURING A MAINTENANCE VISIT, FOUND SEVERAL MISDRILLED HOLES CUSP TO CUSP AT STA 1580, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND…
- 8 Mar 2000
Web, cracked
DURING A MAINTENANCE VISIT FOUND CRACKED AND GOUGED RT WING I/B TE FLAP WELL FWD WEB AT FUS. STA 980 RT WING STA XW5. EO, DAMAGE EXCEEDED LIMITATIONS IAW DC-8…
- 8 Mar 2000
Frame, cracked
DURING A MAINTENANCE VISIT, FOUND A CRACK IN THE CABIN AT STA 520 AND L6L TO L7L, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED…
- 8 Mar 2000
Skin, cracked
DURING A MAINTENANCE VISIT, FOUND A 2.5 INCH CRACK TO THE RT WING UPPER SKIN AT STA 960 AND XCW 69.5 , DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED…
- 7 Mar 2000
Floorbeam, misdrilled
DURING A MAINTENANCE VISIT, FOUND SEVERAL MISDRILLED HOLES CUSP TO CUSP AT STA 1560, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND…
- 6 Mar 2000
Panel, delaminated
DURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE AT LT WING O/B AILERON I/B HINGED PANEL, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED…
- 6 Mar 2000
Floorbeam, corroded
DURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE FLOORBEAM AT STA 1480 AT LONGERON 21 X + 12 Z O, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED…
- 6 Mar 2000
Vane, delaminated
DURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO THE RT WING IB FLAP O/B FLAP VANE, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED…
- 3 Mar 2000
Floorbeam, misdrilled
DURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN THE AFT LWR CARGO COMPT TOP OF FLOORBEAM AT STA 1480, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.…
- 1 Mar 2000
Panel, delaminated
DURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO LT WING REAR SPAR UPPER PANEL AT STA XRS 589 TO STA XRS 530, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.…
- 1 Mar 2000
Web, cracked
DURING A MAINTENANCE VISIT FOUND A CRACK IN THE R-1 DOOR FWD LIGHTING HOLE, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA…
- 1 Mar 2000
Web, cracked
DURING A MAINTENANCE VISIT, FOUND A CRACK IN THE FUSELAGE STRUCTURE, R-1 DOOR JAM LIGHTING HOLE AT STA 348 TO 354 R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.…
- 29 Feb 2000
Panel, delaminated
DURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO THE RT WING T/E LWR PANEL I/B OF O/B FLAP I/B HINGE, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED…
- 29 Feb 2000
Pan, damaged
DURING A MAINTENANCE VISIT, FOUND THE L-1 DOOR THRESHOLD DRAIN HOLE RIPPED OPEN, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED…
- 29 Feb 2000
Fitting, misdrilled
DURING A MAINTENANCE VISIT FOUND A HOLE DRILLED IN TERMINAL LUG FITTING FWD. AT STA 857 AND LONGERON 21RT, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED…
- 29 Feb 2000
Longeron, cracked
DURING A MAINTENANCE VISIT FOUND A CRACKED LONGERON BETWEEN STA. 781 TO 778 RT. AND LONGERON 10 RT, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE,…
- 29 Feb 2000
Web, cracked
DURING A MAINTENANCE VISIT FOUND A GOUGED & CRACKED I/B TE FLAP WELL WEB ON THE RT WING STA XW5 STA. 1020 TO 980, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.…
- 29 Feb 2000
Attach Fitting, cracked
DURING A MAINTENANCE VISIT, FOUND A CRACK TO THE FLOORBEAM ATTACH FITTING AT STA 781 RT, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED…
- 29 Feb 2000
Attach Fitting, cracked
DURING A MAINTENANCE VISIT, FOUND A CRACK TO THE FLOORBEAM ATTACH FITTING AT STA 798 LT, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND…
- 28 Feb 2000
Panel, delaminated
DURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE RT WING T/E UPPER PANEL AT STA XRS 530 TO XRS 580, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED…
- 28 Feb 2000
Door Frame, cracked
DURING A MAINTENANCE VISIT, FOUND A CRACK TO THE FUSELAGE STRUCTURE AT AFT FRAME JAMB (R2 DOOR) AT STA 1500 R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.…
- 28 Feb 2000
Fitting, corroded
DURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGEA TO THE FUSELAGE STRUCTURE AT LONGERON BATHTUB FITTING AT STA 1520 TO 1530 AND L22R, DAMAGE EXCEEDED…
- 25 Feb 2000
Intercostal, misdrilled
DURING A MAINTENANCE VISIT, FOUND SEVERAL MISDRILLED HOLES IN THE UPPER CARGO COMPT FLOORBEAM INTERCOSTALS AT STA 280 TO 270, DAMAGE EXCEEDED LIMITATIONS IAW…
- 25 Feb 2000
Intercostal, misdrilled
DURING A MAINTENANCE VISIT, FOUND SEVERAL MISDRILLED HOLES IN THE UPPER CARGO COMPT FLOORBEAM INTERCOSTALS STA 270 TO 225, DAMAGE EXCEEDED LIMITATIONS IAW…
- 25 Feb 2000
Intercostal, misdrilled
DURING A MAINTENANCE VISIT, FOUND SEVERAL MISDRILLED HOLES IN THE UPPER CARGO COMPT FLOORBEAM INTERCOSTALS BETWEEN STA 1540 TO 1557, DAMAGE EXCEEDED…
- 25 Feb 2000
Intercostal, misdrilled
DURING A MAINTENANCE VISIT, FOUND SEVERAL MISDRILLED HOLES IN THE UPPER CARGO COMPT FLOORBEAM INTERCOSTALS AT STA 1220 TO 1240, DAMAGE EXCEEDED LIMITATIONS…
- 25 Feb 2000
Intercostal, misdrilled
DURING A MAINTENANCE VISIT, FOUND SEVERAL MISDRILLED HOLES IN THE UPPER CARGO COMPT FLOORBEAM INTERCOSTALS AT STA 1280 TO 1300, DAMAGE EXCEEDED LIMITATIONS…
- 25 Feb 2000
Intercostal, misdrilled
DURING A MAINTENANCE VISIT, FOUND SEVERAL MISDRILLED HOLES IN THE UPPER CARGO COMPT FLOORBEAM INTERCOSTALS AT STA 1360 TO 1380, DAMAGE EXCEEDED LIMITATIONS…
- 25 Feb 2000
Fitting, cracked
DURING A MAINTENANCE VISIT, FOUND THE END FITTING AT PRODUCTION BREAK AFT SIDE CRACKED AT STA 1530 AND L24L, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED…
- 25 Feb 2000
Fitting, corroded
DURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO THE FITTING WHEEL WELL UPPER SURFACE BETWEEN STA 960 TO 980 RT. Z AXIS -9, RBL -40, DAMAGE EXCEEDED…
- 25 Feb 2000
Fitting, corroded
DURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE FITTING WHEEL WELL UPPER SURFACE BETWEEN STA 960 TO 980 LT. Z AXIS -9, LBL +27 TO 39, DAMAGE EXCEEDED…
- 25 Feb 2000
Fitting, corroded
DURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE FITTING WHEEL WELL UPPER SURFACE AT STA 977 TO 980 LT. Z AXIS -9, LBL +25 LT., DAMAGE EXCEEDED…
- 25 Feb 2000
Intercostal, misdrilled
DURING A MAINTENANCE VISIT FOUND SEVERAL MISDRILLED HOLES IN THE UPPER CARGO COMPT. FLOOR BEAM INTERCOSTALS AT FS 680 TO 660, DAMAGE EXCEEDED LIMITATIONS IAW…
- 25 Feb 2000
Angle, cracked
DURING A MAINTENANCE VISIT FOUND CRACKED ATTACH ANGLES AT BS 680 TO 660, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW…
- 25 Feb 2000
Angle, cracked
DURING A MAINTENANCE VISIT FOUND CRACKED ATTACH ANGLES AT FS 420 TO 400, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW…
- 25 Feb 2000
Intercostal, misdrilled
DURING A MAINTENANCE VISIT FOUND SEVERAL MISDRILLED HOLES IN THE UPPER CARGO BAY. FLOORBEAM INTERCOSTALS AT FS 560 TO 540, DAMAGE EXCEEDED LIMITATIONS IAW…
- 25 Feb 2000
Bracket, cracked
DURING A MAINTENANCE VISIT FOUND A CRACKED INTERCOSTAL BRACKET AT STA 560 TO 540, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED…
- 25 Feb 2000
Structure, chafed
DURING A MAINTENANCE VISIT, FOUND CHAFFING BY THE ATTACH HOLES ON THE RT WING NR 4 STUB WING LE BOTTOM IB, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED…
- 25 Feb 2000
Floorbeam, misdrilled
DURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN THE FLOORBEAM AT STA 940, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND…
- 25 Feb 2000
Floorbeam, misdrilled
DURING A MAINTENANCE VISIT FOUND NUMEROUS DRILLED HOLES IN THE FLOOR BEAM AT STA 902 CUSP TO CUSP, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE,…
- 25 Feb 2000
Floorbeam, misdrilled
DURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN THE AFT LWR CARGO COMPT. TOP OF FLOORBEAM AT STA 1300, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.…
- 25 Feb 2000
Attach Angle, cracked
DURING A MAINTENANCE VISIT, FOUND A CRACK TO THE INTERCOSTAL TO BEAM ATTACH ANGLE AT STA 270 LT AND LBL 46 Z-AXIS 1INCH, DAMAGE EXCEEDED LIMITATIONS IAW DC-8…
- 25 Feb 2000
Intercostal, damaged
DURING A MAINTENANCE VISIT, FOUND LARGE HOLE IN INTERCOSTAL AT CABIN UPPER CARGO COMPT. AT FS 1300 TO 1320 AND LONG. STR 3L, DAMAGE EXCEEDED LIMITATIONS IAW…
- 25 Feb 2000
Intercostal, misdrilled
DURING A MAINTENANCE VISIT FOUND SEVERAL MISDRILLED HOLES IN THE UPPER CARGO COMPT. FLOOR BEAM INTERCOSTALS AT FS 420 TO 400, DAMAGE EXCEEDED LIMITATIONS IAW…
- 24 Feb 2000
Panel, corroded
DURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO TAIL RT HORIZ STAB REAR SPAR UPPER SURFACE INSIDE AT STA XE52.825 -XE.75.672, DAMAGE EXCEEDED…
- 24 Feb 2000
Panel, corroded
DURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO TAIL RT HORIZ STAB REAR SPAR UPPER SURFACE INSIDE BETWEEN STA XE245 TO XE270, DAMAGE EXCEEDED…
- 24 Feb 2000
Panel, corroded
DURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO TAIL RT HORIZ STAB REAR SPAR UPPER SURFACE AT STA XE 219 TO XE 245, DAMAGE EXCEEDED LIMITATIONS IAW DC-8…
- 24 Feb 2000
Panel, corroded
DURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO TAIL RT HORIZ STAB REAR SPAR UPPER SURFACE INSIDE AT STA XE 99 TO XE 123, DAMAGE EXCEEDED LIMITATIONS IAW…
- 24 Feb 2000
Floorboard, worn
DURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO THE CABIN COCKPIT FLOOR PANEL AT STA 148 TO 168, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED…
- 24 Feb 2000
Angle, loose
DURING A MAINTENANCE VISIT, FOUND MISSING AND LOOSE BOLTS IN THE FLOORBEAM ATTACH ANGLE AT STA 400 AND LBL 63, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.…
- 24 Feb 2000
Floorbeam, misdrilled
DURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN THE AFT LWR CARGO COMPT TOP OF FLOORBEAM AT STA 1380, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.…
- 24 Feb 2000
Floorbeam, misdrilled
DURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN THE FUSE STRUCTURE AFT UPPER CARGO COMPT OF FLOORBEAM AT STA 1440, DAMAGE EXCEEDED LIMITATIONS IAW…
- 24 Feb 2000
Angle, corroded
DURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE ACCESS PANEL NR 62 FWD MOST COMPTARTMENT, RT SIDE BOTTOM ANGLE OF FWD BULKHEAD, DAMAGE EXCEEDED…
- 24 Feb 2000
Intercostal, misdrilled
DURING A MAINTENANCE VISIT FOUND SEVERAL MISDRILLED HOLES IN THE UPPER CARGO BAY. FLOORBEAM INTERCOSTALS FLOORBEAM TO FLOORBEAM AT STA 620 TO 600, DAMAGE…
- 24 Feb 2000
Angle, cracked
DURING A MAINTENANCE VISIT FOUND CRACKED ATTACH ANGLES AT FS 620 TO 600, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW…
- 24 Feb 2000
Intercostal, misdrilled
DURING A MAINTENANCE VISIT FOUND SEVERAL MISDRILLED HOLES IN THE UPPER CARGO BAY. FLOORBEAM INTERCOSTALS AT FS 600 TO 580, DAMAGE EXCEEDED LIMITATIONS IAW…
- 24 Feb 2000
Angle, cracked
DURING A MAINTENANCE VISIT FOUND CRACKED ATTACH ANGLES AT FS 600 TO 580, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW…
- 24 Feb 2000
Intercostal, misdrilled
DURING A MAINTENANCE VISIT FOUND SEVERAL MISDRILLED HOLES IN THE UPPER CARGO BAY. FLOORBEAM INTERCOSTALS AT FS 440 TO 420, DAMAGE EXCEEDED LIMITATIONS IAW…
- 24 Feb 2000
Angle, cracked
DURING A MAINTENANCE VISIT FOUND CRACKED ATTACH ANGLES AT FS 420 TO 440, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW…
- 24 Feb 2000
Seat Track, damaged
DURING A MAINTENANCE VISIT FOUND ELONGATED HOLES IN THE CABIN UPPER CARGO COMPT. SEAT TRACK C7-R2, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE,…
- 24 Feb 2000
Floor Support, cracked
DURING A MAINTENANCE VISIT FOUND A CRACKED SUB-FLOOR UNDER L/H ELEC. CENTER AT STA 225 LT. RBL 24 -28 Z AXIS 0, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.…
- 24 Feb 2000
Angle, corroded
DURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE CABIN MAIN CABIN ANGLE AT STA 1040 AND LONGERON -1, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED…
- 24 Feb 2000
Intercostal, misdrilled
DURING A MAINTENANCE VISIT, FOUND SEVERAL MISDRILLED HOLES IN THE UPPER CARGO COMPT. FLOORBEAM INTERCOSTAL AT STA 520 TO 500, DAMAGE EXCEEDED LIMITATIONS IAW…
- 24 Feb 2000
Intercostal, misdrilled
DURING A MAINTENANCE VISIT, FOUND SEVERAL MISDRILLED HOLES IN THE UPPER CARGO COMPT. FLOORBEAM INTERCOSTALS AT STA 480 TO 460, DAMAGE EXCEEDED LIMITATIONS IAW…
- 24 Feb 2000
Attach Angle, cracked
DURING A MAINTENANCE VISIT, FOUND A CRACK TO THE INTERCOSTAL ATTACH ANGLES AT FUSELAGE STA 460 TO 400, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED…
- 24 Feb 2000
Intercostal, misdrilled
DURING A MAINTENANCE VISIT, FOUND SEVERAL MISDRILLED HOLES IN THE UPPER CARGO COMPT. FLOORBEAM INTERCOSTALS AT STA 460 TO 440, DAMAGE EXCEEDED LIMITATIONS IAW…
- 24 Feb 2000
Intercostal, misdrilled
DURING A MAINTENANCE VISIT, FOUND SEVERAL MISDRILLED HOLES IN THE UPPER CARGO COMPT. FLOORBEAM INTERCOSTALS AT FS 400 TO 380, DAMAGE EXCEEDED LIMITATIONS IAW…
- 24 Feb 2000
Attach Angle, cracked
DURING A MAINTENANCE VISIT, FOUND A CRACK TO THE INTERCOSTAL ATTACH ANGLES IN THE UPPER CARGO COMPT. FS 400 TO 380, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.…
- 24 Feb 2000
Longeron, cracked
DURING A MAINTENANCE VISIT, FOUND A CRACK TO THE FUSELAGE STRUCTURE, LWR CARGO BILGE AT STA 1160 AND L32LT, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED…
- 24 Feb 2000
Hinge, cracked
DURING A MAINTENANCE VISIT FOUND A CRACK TO THE NR 1 PYLON TOP PLYLON CAP HINGE, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW…
- 24 Feb 2000
Floorbeam, misdrilled
DURING A MAINTENANCE VISIT FOUND NUMEROUS DRILLED HOLES IN THE AFT UPPER CARGO COMPT. TOP OF FLOORBEAM AT STA 1530, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.…
- 24 Feb 2000
Attach Fitting, cracked
DURING A MAINTENANCE VISIT, FOUND A CRACK TO THE BATH TUB FITTING AT STA 1530 AND L24 RT, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED…
- 24 Feb 2000
Floorbeam, misdrilled
DURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN THE FLOORBEAM STA 920 CUSP TO CUSP, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE,…
- 24 Feb 2000
Floorbeam, misdrilled
DURING A MAINTENANCE VISIT FOUND NUMEROUS MISDRILLED HOLES IN THE CABIN FLOORBEAM AT STA 857 CUSP TO CUSP, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED…
- 24 Feb 2000
Floorbeam, misdrilled
DURING A MAINTENANCE VISIT FOUND NUMEROUS MISDRILLED HOLES IN THE CABIN FLOORBEAM AT STA 857 CUSP TO CUSP, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED…
- 24 Feb 2000
Floorbeam, misdrilled
DURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN THE AFT LWR CARGO COMPT. TOP OF FLOORBEAM AT STA 1340, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.…
- 24 Feb 2000
Floorbeam, misdrilled
DURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN THE AFT LWR CARGO COMPT. TOP OF FLOORBEAM AT STA 1320, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.…
- 24 Feb 2000
Boss, corroded
DURING A MAINTENANCE VISIT, FOUND THAT THE LT MLG REQUIRES RE-WORK ON BOSS, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8…
- 24 Feb 2000
Boss, corroded
DURING A MAINTENANCE VISIT, FOUND THAT THE RT. MLG REQUIRES RE-WORK ON BOSS, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8…
- 24 Feb 2000
Attach Fitting, cracked
DURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE AND A POSSIBLE CRACK AT THE RT WHEEL WELL ATTACH FITTING AT STA 960 AND L24R, DAMAGE EXCEEDED LIMITATIONS…
- 24 Feb 2000
Seat Track, damaged
DURING A MAINTENANCE VISIT, FOUND ELONGATED HOLES IN THE CABIN F/E FWD SEAT TRACK LOCKING HOLES, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE,…
- 24 Feb 2000
Floorboard, corroded
DURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO THE MAIN CABIN FLOORING AT STA 225 TO 208 AND RBL 10 TO RBL 45 Z AXIS 0, DAMAGE EXCEEDED LIMITATIONS IAW…
- 23 Feb 2000
Panel, delaminated
DURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO LT WING REAR SPAR UPPER PANEL AT STA XRS 624 TO STA XRS 693, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.…
- 23 Feb 2000
Panel, delaminated
DURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO THE LT WING TRAILING EDGE LOWER PANEL BETWEEN O/B FLAP CENTER AND O/B HINGES, DAMAGE EXCEEDED…
- 23 Feb 2000
Intercostal, misdrilled
DURING A MAINTENANCE VISIT, FOUND HOLES DRILLED IN RADIUS OF INTERCOSTAL AT THE CABIN UPPER CARGO COMPT STA 1270 AND LONGERON ST 19L, DAMAGE EXCEEDED…
- 23 Feb 2000
Intercostal, misdrilled
DURING A MAINTENANCE VISIT, FOUND HOLES DRILLED IN RADIUS OF INTERCOSTAL IN CABIN UPPER CARGO COMPT STA 1240 TO 1260 AND LONG ST 14L, DAMAGE EXCEEDED…
- 23 Feb 2000
Intercostal, misdrilled
DURING A MAINTENANCE VISIT, FOUND HOLES DRILLED IN RADIUS OF INTERCOSTAL CABIN UPPER CARGO COMPT STA 1200 TO 1200 LONG ST 14L, DAMAGE EXCEEDED LIMITATIONS IAW…
- 23 Feb 2000
Frame, cracked
DURING A MAINTENANCE VISIT, FOUND THE FUSELAGE STRUCTURE FWD OF LT W/W PANEL SUPPORT FRAME CRACKED O/B PANEL 161S AT STA 834, DAMAGE EXCEEDED LIMITATIONS IAW…
- 23 Feb 2000
Finger Doubler, corroded
DURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE FINGER DOUBLER IN CABIN STA 188 TO 208 AND RBL 69, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED…
- 23 Feb 2000
Floorbeam, misdrilled
DURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN THE AFT LWR CARGO COMPT. TOP OF FLOORBEAM AT STA 1260, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.…
- 23 Feb 2000
Plate, damaged
DURING A MAINTENANCE VISIT, FOUND A TEMP. REPAIR AT EXT. AIR RECEPTICLE, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW…
- 23 Feb 2000
Intercostal, misdrilled
DURING A MAINTENANCE VISIT, FOUND A HOLE DRILLED IN RADIUS OF INTERCOSTAL IN THE CABIN UPPER CARGO COMPT. AT FS 1280 TO 1300 AND LONG. 14L, DAMAGE EXCEEDED…
- 22 Feb 2000
Panel, delaminated
DURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO THE LT WING FILLET PANEL AT 161P, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA…
- 22 Feb 2000
Web, chafed
DURING A MAINTENANCE VISIT FOUND CHAFFING AT THE LT AFT FILLET WEB AT FUSELAGE STA 920, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, ALODINED AND…
- 22 Feb 2000
Floor Support, cracked
DURING A MAINTENANCE VISIT FOUND SEVERAL AREAS CRACKED IN THE FLOOR SUPPORT AND ATTACH ANGLE 2 AXIS 0 BETWEEN STA 225 TO 208 AND LBL 14 TO RBL 11, DAMAGE…
- 22 Feb 2000
Web, cracked
DURING A MAINTENANCE VISIT, FOUND CRACKED HOLES AND A CRACKED MEMBRANE IN THE CABIN BETWEEN STA 225 TO 270 AND L21R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.…
- 21 Feb 2000
Panel, delaminated
DURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE RT WING REAR SPAR UPPER PANEL AT STA 456 TO XRS 519, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.…
- 21 Feb 2000
Panel, delaminated
DURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE LT WING FILLET PANEL AT 161Q, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA…
- 21 Feb 2000
Panel, delaminated
DURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO THE LT WING REAR SPAR UPPER PANEL AT STA XRS 653 TO STA XRS 763, DAMAGE EXCEEDED LIMITATIONS IAW DC-8…
- 21 Feb 2000
Panel, delaminated
DURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE RT WING T/E UPPER PANEL AT STA XRS 580 TO XRS 630, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED…
- 21 Feb 2000
Panel, delaminated
DURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO THE RT WING T/E LWR PANEL AFT OF FUEL DUMP HINGE PANEL, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.…
- 21 Feb 2000
Floorbeam, misdrilled
DURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN THE AFT LWR CARGO COMPT TOP OF FLOORBEAM AT STA 1500, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.…
- 21 Feb 2000
Floorbeam, misdrilled
DURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN THE AFT LWR CARGO COMPT TOP OF FLOORBEAM AT STA 1400, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.…
- 21 Feb 2000
Floorbeam, misdrilled
DURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN THE AFT LWR CARGO COMPT. TOP OF FLOORBEAM AT STA 1180, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.…
- 21 Feb 2000
Floorbeam, misdrilled
DURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN THE AFT LWR CARGO COMPT. TOP OF FLOORBEAM AT STA 1000, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.…
- 21 Feb 2000
Spar, corroded
DURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO THE LT WING REAR SPAR UPPER SURFACE AT STA XRS 162 TO 163, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.…
- 18 Feb 2000
Floorbeam, misdrilled
DURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN THE AFT LWR CARGO COMPT. TOP OF FLOORBEAM AT STA 1200, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.…
- 18 Feb 2000
Panel, delaminated
DURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO THE LT WING TRAILING EDGE LOWER PANEL AFT OF DUMP CHUTE, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.…
- 18 Feb 2000
Floorbeam, misdrilled
DURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN THE AFT LWR CARGO COMPT TOP OF FLOORBEAM AT STA 1460, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.…
- 18 Feb 2000
Skin, cracked
DURING A MAINTENANCE VISIT, FOUND A CRACK TO THE R-2 DOOR IN THE LOWER INNER SKIN CENTER OF DOOR BOTTOM, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED…
- 18 Feb 2000
Attach Fitting, misdrilled
DURING A MAINTENANCE VISIT FOUND A DRILLED HOLE IN THE FUSELAGE. STRUCTURE FLOORBEAM ATTACH FITTING AT UPPER LEG IN RADIUS OF STA 702 LBL +23, AXIS 0, DAMAGE…
- 18 Feb 2000
Attach Fitting, cracked
DURING A MAINTENANCE VISIT FOUND A CRACK TO THE FLOORBEAM ATTACH FITTING UPPER CHORD (MAIN CABIN) AT STA 717 AND RBL -23 Z AXIS 0, DAMAGE EXCEEDED LIMITATIONS…
- 18 Feb 2000
Floorbeam, misdrilled
DURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN THE AFT LWR CARGO COMPT. TOP OF FLOORBEAM AT STA 1140, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.…
- 18 Feb 2000
Floorbeam, misdrilled
DURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN THE AFT LWR CARGO COMPT. TOP OF FLOORBEAM AT STA 1120, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.…
- 18 Feb 2000
Longeron, corroded
DURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO THE DOUBLER ATTACHED TO LONGERON IN AFT LOWER CARGO BILGE AT STA 1080 TO 1100 AND L35R, DAMAGE EXCEEDED…
- 17 Feb 2000
Floorbeam, misdrilled
DURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILL HOLES IN THE AFT LWR CARGO COMPT TOP OF FLOORBEAM AT STA 1520, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.…
- 17 Feb 2000
Floorbeam, misdrilled
DURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN THE FLOOR BEAM AT STA 980, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND…
- 17 Feb 2000
Floorbeam, cracked
DURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE RT FLOORBEAM UPPER LOWER CARGO BAY FS 360, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE,…
- 17 Feb 2000
Floorbeam, misdrilled
DURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN THE AFT LWR CARGO COMPT. TOP OF FLOORBEAM AT STA 1280, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.…
- 17 Feb 2000
Floorbeam, misdrilled
DURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN THE AFT LWR CARGO COMPT. TOP OF FLOORBEAM AT STA 1160, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.…
- 17 Feb 2000
Floorbeam, misdrilled
DURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN THE AFT LWR CARGO COMPT. TOP OF FLOORBEAM AT ST 1100, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.…
- 17 Feb 2000
Floorbeam, misdrilled
DURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN THE AFT LWR CARGO COMPT. TOP OF FLOORBEAM AT STA 1240, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.…
- 17 Feb 2000
Floorbeam, misdrilled
DURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN THE AFT LWR CARGO COMPT. TOP OF FLOORBEAM AT STA 1360, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.…
- 17 Feb 2000
Floorbeam, misdrilled
DURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN THE AFT LWR CARGO COMPT. TOP OF FLOORBEAM AT STA 1020, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.…
- 16 Feb 2000
Panel, delaminated
DURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO THE LT WING TRAILING EDGE LOWER PANEL AFT OF FUEL DUMP CHUTE HINGED DOOR, DAMAGE EXCEEDED LIMITATIONS…
- 16 Feb 2000
Structure, cracked
DURING A MAINTENANCE VISIT, FOUND 5 CRACKS TO THE BULKHEAD THRU DOOR AT THE AFT LOWER CARGO BILGE AT STA 1380, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.…
- 16 Feb 2000
Floorbeam, misdrilled
DURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN THE AFT LWR CARGO COMPT. TOP OF FLOORBEAM AT STA 1220, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.…
- 15 Feb 2000
Floorbeam, misdrilled
DURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN THE FWD LWR CARGO COMPT TOP OF FLOORBEAM AT STA 620, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.…
- 14 Feb 2000
Panel, delaminated
DURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO THE LT WING TRAILING EDGE UPPER PANEL I/B OF I/B AILERON, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.…
- 14 Feb 2000
Floorbeam, misdrilled
DURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN THE FWD LWR CARGO COMPT. TOP OF FLOORBEAM AT STA 480, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.…
- 14 Feb 2000
Floorbeam, misdrilled
DURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN THE FWD LWR CARGO COMPT. TOP OF FLOORBEAM AT STA 420, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.…
- 14 Feb 2000
Floorbeam, misdrilled
DURING A MAINTENANCE VISIT FOUND NUMEROUS MISDRILLED HOLES IN THE CABIN FLOOR AT STA 834 CUSP TO CUSP, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED…
- 14 Feb 2000
Floorbeam, misdrilled
DURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN THE AFT LWR CARGO COMPT. TOP OF FLOORBEAM AT STA 1040, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.…
- 12 Feb 2000
Panel, delaminated
DURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO THE LT WING AUX SPAR LOWER PANEL, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA…
- 11 Feb 2000
Floorbeam, misdrilled
DURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN THE AFT UPPER CARGO COMPT TOP OF FLOORBEAM AT STA 1420, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.…
- 11 Feb 2000
Floorbeam, misdrilled
DURING A MAINTENANCE VISIT FOUND NUMEROUS MISDRILLED HOLES IN THE CABIN FLOORBEAM AT STA 822 CUSP TO CUSP, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED…
- 11 Feb 2000
Attach Fitting, cracked
DURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE AND POSSIBLE CRACK ON THE ATTACH FITTING AT STA 940 AND L24R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.…
- 10 Feb 2000
Shim, cracked
DURING A MAINTENANCE VISIT FOUND A CRACK TO THE RT. WING I/B NR 4 PYLON WING SPAR LWR CHORD SHIM PLATE, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED…
- 10 Feb 2000
Shim, cracked
DURING A MAINTENANCE VISIT FOUND A CRACK TO THE LT. WING I/B NR 1 PYLON WING SPAR LWR CHORD SHIM PLATE, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED…
- 10 Feb 2000
Fitting, corroded
DURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE IN THE LT WHEEL WELL AT STA 940 AND LONGERON 24 LT. ON LONGERON 24, DAMAGE EXCEEDED LIMITATIONS IAW DC-8…
- 10 Feb 2000
Spar Cap, gouged
DURING A MAINTENANCE VISIT FOUND A GOUGE AT THE SCREW HOLE ON THE LT WING I/B L/E LWR FRONT SPAR CAP, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED…
- 10 Feb 2000
Floorbeam, misdrilled
DURING A MAINTENANCE VISIT FOUND NUMEROUS DRILLED HOLES IN THE CABIN FLOORBEAM AT STA 742 CUSP TO CUSP, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED…
- 9 Feb 2000
Fitting, corroded
DURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE VERTICAL STIFFNER AT STA 188 AND RBL 69 Z AXIS -10, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED…
- 9 Feb 2000
Floorbeam, misdrilled
DURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN THE FWD LWR CARGO COMPT. TOP OF FLOORBEAM AT STA 460, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.…
- 9 Feb 2000
Floorbeam, misdrilled
DURING A MAINTENANCE VISIT FOUND NUMEROUS DRILLED HOLES IN THE CABIN FLOOR BEAM AT STA 781 CUSP TO CUSP, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED…
- 9 Feb 2000
Floorbeam, misdrilled
DURING A MAINTENANCE VISIT FOUND NUMEROUS MISDRILLED HOLES IN THE CABIN FLOORBEAM AT STA 717 CUSP TO CUSP, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED…
- 8 Feb 2000
Attach Fitting, cracked
DURING A MAINTENANCE VISIT, FOUND A CRACK TO THE FLOORBEAM ATTACH FITTING AT STA 759 RT, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED…
- 8 Feb 2000
Floorbeam, misdrilled
DURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES TO THE TOP OF FLOORBEAM IN THE FWD. UPPER CARGO COMPT. AT STA 360, DAMAGE EXCEEDED LIMITATIONS IAW…
- 7 Feb 2000
Fitting, cracked
DURING A MAINTENANCE VISIT FOUND A CRACKED FITTING AT THE PRODUCTION BREAK AT STA 680 - 700 AND LONG 11 RT, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED…
- 3 Feb 2000
Fitting, cracked
DURING A MAINTENANCE VISIT FOUND A CRACK TO THE FRAME TO LONGERON ATTACH FITTING AT FRAME AT STA 680 LT. AND LONGERON 11 LT, DAMAGE EXCEEDED LIMITATIONS IAW…
- 3 Feb 2000
Skin, corroded
DURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO SCREW HOLES INBD L/E UPPER SURFACE LT. WING AT STA XFS 157 TO XFS 145, DAMAGE EXCEEDED LIMITATIONS IAW…
- 3 Feb 2000
Skin, damaged
DURING A MAINTENANCE VISIT FOUND ELONGATED SCREW HOLES INBD. L/E LWR SURFACE AT STA XFS 57 TO XFS 76, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED…
- 3 Feb 2000
Floorbeam, misdrilled
DURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES TO THE TOP FLOORBEAM AT FWD. UPPER CARGO COMPT. STA 380, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.…
- 3 Feb 2000
Floorbeam, misdrilled
DURING A MAINTENANCE VISIT FOUND NUMEROUS DRILLED HOLES IN THE FWD. CARGO COMPT TOP OF FLOOR BEAM AS STA 270, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.…
- 3 Feb 2000
Fitting, broken
DURING A MAINTENANCE VISIT FOUND A BROKEN FASTENER AT THE RT. WING NR 3 STUB WING THROUGH STUB WING FRAME FITTING, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.…
- 3 Feb 2000
Floorbeam, misdrilled
DURING A MAINTENANCE VISIT FOUND NUMEROUS DRILLED HOLES IN THE FWD. UPPER CARGO COMPT. TOP OF FLOORBEAM AT STA 640, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.…
- 3 Feb 2000
Floorbeam, misdrilled
DURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN THE FWD UPPER CARGO COMPT. TOP OF FLOORBEAM AT STA 400, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.…
- 3 Feb 2000
Structure, corroded
DURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE LT WING SCREW HOLES AT THE CENTER LE UPPER SURFACE AT XFS 422, DAMAGE EXCEEDED LIMITATIONS IAW DC-8…
- 3 Feb 2000
Skin, corroded
DURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE AROUND THE SCREW HOLES ON THE LT WING CENTER LE UPPER SURFACE AT XFS 325 TO XFS 304, DAMAGE EXCEEDED…
- 3 Feb 2000
Pressure Panel, distorted
DURING A MAINTENANCE VISIT, FOUND DISTORTED SKIN IN THE RT WHEEL WELL AT FWD AND AFT SIDE OF RT MLG OPENING, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED…
- 3 Feb 2000
Frame, cracked
DURING A MAINTENANCE VISIT, FOUND A CRACK IN THE WHEEL WELL FRAME OUTBD. SIDE NEAR OPENING FOR GEAR, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE,…
- 31 Jan 2000
Attach Fitting, gouged
DURING A MAINTENANCE VISIT, FOUND A GOUGE TO THE UPPER CARGO COMPT MAIN CARGO DOOR FLOORBEAM ATTACH PLATE AT STA 400 TO XCW 64L, DAMAGE EXCEEDED LIMITATIONS…
- 31 Jan 2000
Skin, damaged
DURING A MAINTENANCE VISIT, FOUND ELONGATED HOLES IN THE LEFT MID-WING L/E ON LOWER SURFACE AT STA XS 520.168, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.…
- 31 Jan 2000
Floorbeam, misdrilled
DURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN THE CABIN FLOORBEAM AT STA 798 CUSP TO CUSP, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED…
- 31 Jan 2000
Floorbeam, misdrilled
DURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN THE CABIN FLOORBEAM AT STA 759 CUSP TO CUSP, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED…
- 31 Jan 2000
Floorbeam, cracked
DURING A MAINTENANCE VISIT, FOUND A CRACK TO THE FLOORBEAM IN THE UPPER CARGO COMPT FS 360 AND XCW 64L, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED…
- 31 Jan 2000
Attach Angle, misdrilled
DURING A MAINTENANCE VISIT, FOUND DRILL HOLES IN THE FLOORBEAM ATTACH ANGLE IN THE UPPER CARGO COMPT FS 460 AND XCW 64L, DAMAGE EXCEEDED LIMITATIONS IAW DC-8…
- 28 Jan 2000
Floorbeam, misdrilled
DURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN THE FWD LWR CARGO COMPT TOP OF FLOORBEAM AT STA 440, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.…
- 28 Jan 2000
Web, torn
DURING A MAINTENANCE VISIT, FOUND A TORN WEB AT THE L1 DOOR AFT JAM LWR BOX AT STA 270, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND…
- 28 Jan 2000
Floorbeam, misdrilled
DURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN THE AFT LWR CARGO COMPT TOP OF FLOORBEAM AT STA 1060, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.…
- 27 Jan 2000
Floorbeam, misdrilled
DURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN THE FWD LWR CARGO COMPT TOP OF FLOORBEAM AT STA 300, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.…
- 27 Jan 2000
Floorbeam, misdrilled
DURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN THE FWD LWR CARGO COMPT TOP OF FLOORBEAM STA 280, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.…
- 27 Jan 2000
Frame, misdrilled
DURING A MAINTENANCE VISIT, FOUND MISDRILLED HOLES IN THE UPPER CARGO COMPT FS 920 AND L21R TO L21L, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE,…
- 27 Jan 2000
Frame, misdrilled
DURING A MAINTENANCE VISIT, FOUND MISDRILLED HOLES IN THE UPPER CARGO COMPT FS 600 AND L21R TO L21L, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE,…
- 27 Jan 2000
Frame, misdrilled
DURING A MAINTENANCE VISIT, FOUND MISDRILLED HOLES IN THE UPPER CARGO COMPT FS 540 AND L21R TO L21L, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE,…
- 27 Jan 2000
Floorbeam, misdrilled
DURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN THE FWD LWR CARGO COMPT TOP OF FLOORBEAM AT STA 560, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.…
- 26 Jan 2000
Frame, misdrilled
DURING A MAINTENANCE VISIT, FOUND MISDRILLED HOLES IN THE UPPER CARGO COMPT AT STA 1460 AND LONGERON 21R TO 21L, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.…
- 26 Jan 2000
Floorbeam, misdrilled
DURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN THE AFT LWR CARGO COMPT TOP OF FLOORBEAM AT STA 1080, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.…
- 25 Jan 2000
Floorbeam, misdrilled
DURING A MAINTENANCE VISIT FOUND MISDRILLED HOLES, CABIN FLOORBEAM AT STA 742 CUSP TO CUSP, NUMEROUS DRILLED HOLES. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM.…
- 25 Jan 2000
Floorbeam, misdrilled
DURING A MAINTENANCE VISIT FOUND MISDRILLED HOLES, FUSELAGE, CABIN FLOORBEAM AT STA 717 CUSP TO CUSP, NUMEROUS DRILLED HOLES. DAMAGE EXCEEDED LIMITS IAW DC-8…
- 25 Jan 2000
Floorbeam, misdrilled
DURING A MAINTENANCE VISIT FOUND MISDRILLED HOLES, FUSELAGE, CABIN FLOORBEAM AT STA 702 CUSP TO CUSP, NUMEROUS DRILLED HOLES. DAMAGE EXCEEDED LIMITS IAW DC-8…
- 25 Jan 2000
Floorbeam, misdrilled
DURING A MAINTENANCE VISIT FOUND MISDRILLED HOLES, FUSELAGE, CABIN FLOORBEAM AT STA 680 CUSP TO CUSP, NUMEROUS DRILLED HOLES. DAMAGE EXCEEDED LIMITS IAW DC-8…
- 25 Jan 2000
Floorbeam, misdrilled
DURING A MAINTENANCE VISIT FOUND MISDRILLED HOLES, FUSELAGE, CABIN FLOORBEAM AT STA 660 CUSP TO CUSP, NUMEROUS DRILLED HOLES. DAMAGE EXCEEDED LIMITS IAW DC-8…
- 25 Jan 2000
Floorbeam, misdrilled
DURING A MAINTENANCE VISIT FOUND MISDRILLED HOLES, FUSELAGE, CABIN FLOORBEAM AT STA 902 CUSP TO CUSP, NUMEROUS DRILLED HOLES. DAMAGE EXCEEDED LIMITS IAW DC-8…
- 25 Jan 2000
Floorbeam, misdrilled
DURING A MAINTENANCE VISIT FOUND MISDRILLED HOLES, FUSELAGE, CABIN FLOORBEAM AT STA 960 FROM CUSP TO CUSP, NUMEROUS DRILLED HOLES. DAMAGE EXCEEDED LIMITS IAW…
- 25 Jan 2000
Frame, misdrilled
DURING A MAINTENANCE VISIT FOUND MISDRILLED HOLES, FUSELAGE, CABIN UPPER CARGO COMPT AT ST 320 BETWEEN LONGERON 21 RIGHT AND LONGERON 21 LEFT (EO). DAMAGE…
- 25 Jan 2000
Frame, misdrilled
DURING A MAINTENANCE VISIT FOUND MISDRILLED HOLES, FUSELAGE, CABIN UPPER CARGO COMPT STA 560, BETWEEN LONGERON 21 RIGHT AND LONGERON 21 LEFT. DAMAGE EXCEEDED…
- 25 Jan 2000
Frame, misdrilled
DURING A MAINTENANCE VISIT FOUND MISDRILLED HOLES, FUSELAGE, UPPER CARGO COMPT AT STA 640, BETWEEN LONGERON 21 RIGHT AND LONGERON 21 LEFT. DAMAGE EXCEEDED…
- 25 Jan 2000
Frame, misdrilled
DURING A MAINTENANCE VISIT FOUND MISDRILLED HOLES, FUSELAGE, UPPER CARGO COMPT AT STA 742 BETWEEN LONGERONS 21 RIGHT AND LONGERON 21 LEFT. DAMAGE EXCEEDED…
- 25 Jan 2000
Frame, misdrilled
DURING A MAINTENANCE VISIT FOUND MISDRILLED HOLES, FUSELAGE, UPPER CARGO COMPT AT STA 1260 BETWEEN LONGERON 21 RIGHT AND LONGERON 21 LEFT. DAMAGE EXCEEDED…
- 25 Jan 2000
Frame, misdrilled
DURING A MAINTENANCE VISIT FOUND MISDRILLED HOLES, FUSELAGE, CABIN - UPPER CARGO COMPT AT STA 320 FRAME. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED,…
- 25 Jan 2000
Frame, misdrilled
DURING A MAINTENANCE VISIT FOUND MISDRILLED HOLES, FUSELAGE, CABIN UPPER CARGO COMPT AT STA 460 FRAME. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED,…
- 25 Jan 2000
Floorbeam, misdrilled
DURING A MAINTENANCE VISIT FOUND MISDRILLED HOLES, FUSELAGE, CABIN FLOORBEAM AT STA 702 CUSP TO CUSP. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED,…
- 25 Jan 2000
Floorbeam, misdrilled
DURING A MAINTENANCE VISIT FOUND MISDRILLED HOLES, FUSELAGE, CABIN FLOORBEAM AT STA 717 CUSP TO CUSP. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED,…
- 25 Jan 2000
Floorbeam, misdrilled
DURING A MAINTENANCE VISIT FOUND MISDRILLED HOLES, FUSELAGE, CABIN FLOORBEAM AT STA 742 CUSP TO CUSP. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED,…
- 25 Jan 2000
Floorbeam, misdrilled
DURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES TO THE TOP OF FLOORBEAM IN THE FWD LWR CARGO COMPT AT STA 340, DAMAGE EXCEEDED LIMITATIONS IAW DC-8…
- 25 Jan 2000
Frame, misdrilled
DURING A MAINTENANCE VISIT, FOUND MISDRILLED HOLES IN THE UPPER CARGO COMPT FS 742 AND L21R TO L21L, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED…
- 25 Jan 2000
Frame, misdrilled
DURING A MAINTENANCE VISIT, FOUND MISDRILLED HOLES IN THE UPPER CARGO COMPT FS 640 AND L21R TO L21L, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE,…
- 25 Jan 2000
Frame, misdrilled
DURING A MAINTENANCE VISIT, FOUND MISDRILLED HOLES IN THE UPPER CARGO COMPT FS 320 AND L21R TO L21L, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE,…
- 25 Jan 2000
Floorbeam, misdrilled
DURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN THE CABIN FLOORBEAM AT STA 660 CUSP TO CUSP, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED…
- 25 Jan 2000
Frame, misdrilled
DURING A MAINTENANCE VISIT, FOUND MISDRILLED HOLES IN THE UPPER CARGO COMPT AT FS 560 AND L21R TO L21L, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED…
- 24 Jan 2000
Fitting, cracked
DURING A MAINTENANCE VISIT FOUND CRACK, FUSELAGE, CABIN FLOORBEAM ATTACH FITTING AT STA 759R. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED…
- 24 Jan 2000
Fitting, cracked
DURING A MAINTENANCE VISIT FOUND CRACK, FUSELAGE, CABIN FLOORBEAM ATTACH FITTING AT STA 798L. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED…
- 24 Jan 2000
Seat Track, damaged
DURING A MAINTENANCE VISIT FOUND ELONGATED HOLES, FUSELAGE, CABIN UPPER CARGO COMPT SEAT TRACK C-10 R2. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED,…
- 24 Jan 2000
Seat Track, damaged
DURING A MAINTENANCE VISIT FOUND ELONGATED HOLE, FUSELAGE, CABIN UPPER CARGO COMPT SEAT TRACK C-12 R3. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED,…
- 24 Jan 2000
Seat Track, damaged
DURING A MAINTENANCE VISIT FOUND ELONGATED HOLES, FUSELAGE, CABIN UPPER CARGO COMPT SEAT TRACK C-10 R6. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED,…
- 24 Jan 2000
Seat Track, damaged
DURING A MAINTENANCE VISIT FOUND ELONGATED HOLES, FUSELAGE, CABIN-UPPER CARGO COMPT SEAT TRACK C-13 R3. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED,…
- 24 Jan 2000
Seat Track, cracked
DURING A MAINTENANCE VISIT FOUND CRACK, FUSELAGE, CABIN-UPPER CARGO COMPT SEAT TRACK C1-R3 CRACKED. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED,…
- 24 Jan 2000
Seat Track, cracked
DURING A MAINTENANCE VISIT FOUND BENT AND CRACKED SEAT TRACK C14, FUSELAGE, CABIN UPPER CARGO COMPT. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED,…
- 24 Jan 2000
Seat Track, misdrilled
DURING A MAINTENANCE VISIT FOUND MISDRILLED HOLES, FUSELAGE, CABIN UPPER CARGO COMPT SEAT RACK C2-R4. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED,…
- 24 Jan 2000
Seat Track, misdrilled
DURING A MAINTENANCE VISIT FOUND MISDRILLED HOLES, FUSELAGE, CABIN UPPER CARGO COMPT SEAT TRACK C1-R4. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED,…
- 24 Jan 2000
Seat Track, broken
DURING A MAINTENANCE VISIT FOUND BROKEN SEAT TRACK, C5-R4, FUSELAGE, CABIN UPPER CARGO COMPT. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED…
- 24 Jan 2000
Floorbeam, misdrilled
DURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN THE FWD LWR CARGO COMPT TOP OF FLOORBEAM AT STA 600, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.…
- 24 Jan 2000
Floorbeam, misdrilled
DURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN THE FWD LWR CARGO COMPT TOP OF FLOORBEAM AT STA 580, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.…
- 21 Jan 2000
Floorbeam, misdrilled
DURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN THE FWD LWR CARGO COMPT TOP OF FLOORBEAM AT STA 520, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.…
- 21 Jan 2000
Floorbeam, misdrilled
DURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN THE FWD LWR CARGO COMPT TOP OF FLOORBEAM AT STA 500, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.…
- 21 Jan 2000
Floorbeam, misdrilled
DURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN THE FWD LWR CARGO COMPT TOP OF FLOORBEAM AT STA 540, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.…
- 21 Jan 2000
Floorbeam, cracked
DURING A MAINTENANCE VISIT, FOUND A CRACKED FLOORBEAM IN THE UPPER CARGO COMPT FS 340 AND XCW 64L, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE,…
- 20 Jan 2000
Skin, cracked
DURING A MAINTENANCE VISIT, FOUND A CRACK TO THE SUB FLOOR SKIN AT STA 225 LT. Z AXIS O LBL 58, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE,…
- 20 Jan 2000
Floorbeam, misdrilled
DURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN THE FWD LWR CARGO COMPT TOP OF FLOORBEAM AT STA 320, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.…
- 19 Jan 2000
Skin, corroded
DURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE AROUND SCREW HOLES LT WING I/B LEADING EDGE UPPER SURFACE AT STA XFS 13.750, DAMAGE EXCEEDED LIMITATIONS…
- 15 Jan 2000
Frame, misdrilled
DURING A MAINTENANCE VISIT, FOUND NUMEROUS HOLES THROUGHOUT FRAME AT FRAME 878 FROM CUSP TO CUSP LONGERON 21R TO LONGERON 21L, DAMAGE EXCEEDED LIMITATIONS IAW…
- 14 Jan 2000
Frame, misdrilled
DURING A MAINTENANCE VISIT FOUND MISDRILLED HOLES IN THE UPPER CARGO COMPT AT FS 300 AND L21R TO L21L, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED…
- 13 Jan 2000
Intercostal, damaged
DURING A MAINTENANCE VISIT FOUND DAMAGE, FUSELAGE, CABIN AT STA 620, LONGERON 11 RIGHT, INTERCOSTAL TIE HAS A SAW CUT IN IT. DAMAGE EXCEEDED LIMITS IAW DC-8…
- 13 Jan 2000
Skin, corroded
DURING A MAINTENANCE VISIT FOUND CORROSION, FUSELAGE, SKIN BETWEEN STA 1500 AND STA 1520 LT BETWEEN LONGERON 21 LEFT AND LONGERON 22 LEFT. DAMAGE EXCEEDED…
- 13 Jan 2000
Floor Panel, misdrilled
DURING A MAINTENANCE VISIT FOUND MISDRILLED HOLES, FUSELAGE, FORM NR 84, ITEM NR 1 NUMEROUS DRILLED HOLES IN FLOOR PLANK/PANEL. DAMAGE EXCEEDED LIMITS IAW…
- 13 Jan 2000
Floor Panel, misdrilled
DURING A MAINTENANCE VISIT FOUND MISDRILLED HOLES, FUSELAGE, FORM #84, ITEM #4, NUMEROUS HOLES THROUGHOUT FLOOR PLANK/PANEL. (C12-R11). DAMAGE EXCEEDED LIMITS…
- 13 Jan 2000
Floor Panel, misdrilled
DURING A MAINTENANCE VISIT FOUND MISDRILLED HOLES, FUSELAGE, FORM NR 84, ITEM NR 4, NUMEROUS DRILLED HOLES ON FLOOR PLANK/PANEL (C7-R1). DAMAGE EXCEEDED…
- 13 Jan 2000
Floor Panel, misdrilled
DURING A MAINTENANCE VISIT FOUND MISDRILLED HOLES, FUSELAGE, FORM NR 84, ITEM NR 4 & NR 5. WORN DRILLED HOLE AREAS ON FLOOR PLANK AND NUMEROUS DRILLED HOLES…
- 13 Jan 2000
Floor Panel, misdrilled
DURING A MAINTENANCE VISIT FOUND MISDRILLED HOLES, FUSELAGE, FORM NR 84, ITEM NR 2 NUMEROUS DRILLED HOLES ON FLOOR PLANK (C1-R1). DAMAGE EXCEEDED LIMITS IAW…
- 13 Jan 2000
Floor Panel, misdrilled
DURING A MAINTENANCE VISIT FOUND MISDRILLED HOLES, FUSELAGE, FORM NR 84 ITEM NR 5 SCREW HOLE CRACKED 63-1/2 FROM EDGE AND 3 FROM OUTBOARD EDGE (C5-R4). DAMAGE…
- 13 Jan 2000
Floor Panel, misdrilled
DURING A MAINTENANCE VISIT FOUND MISDRILLED HOLES, FUSELAGE, FORM NR 84 ITEM NR 1 NUMEROUS DRILLED HOLES THROUGHOUT FLOOR PANEL (C5-R2). DAMAGE EXCEEDED…
- 13 Jan 2000
Floor Panel, misdrilled
DURING A MAINTENANCE VISIT FOUND MISDRILLED HOLES, FUSELAGE, FORM NR 84 ITEM NR 1 NUMEROUS DRILLED HOLES ON FLOOR PLANK/PANEL (C9-R13). DAMAGE EXCEEDED LIMITS…
- 13 Jan 2000
Floor Panel, misdrilled
DURING A MAINTENANCE VISIT FOUND MISDRILLED HOLES, FUSELAGE, FORM NR 84 ITEM NR 1 NUMEROUS DRILLED HOLES FLOOR PANEL (C12-R3). DAMAGE EXCEEDED LIMITS IAW DC-8…
- 13 Jan 2000
Floor Panel, misdrilled
DURING A MAINTENANCE VISIT FOUND MISDRILLED HOLES, FUSELAGE, FORM #84 ITEMS #1, #3, AND #5 NUMEROUS DRILLED HOLES THROUGH FLOOR PLANK/PANEL. ALSO LARGE HOLE…
- 13 Jan 2000
Floor Panel, misdrilled
DURING A MAINTENANCE VISIT FOUND MISDRILLED HOLES, FUSELAGE, FORM NR 84 ITEMS NR 4 AND NR 5 12 FROM EDGE FLANGE DRILLED. ALSO NUMEROUS DRILLED HOLES…
- 13 Jan 2000
Floor Panel, misdrilled
DURING A MAINTENANCE VISIT FOUND MISDRILLED HOLES, FUSELAGE, FORM NR 84 ITEM NR 1 NUMEROUS DRILLED HOLES THROUGHOUT FLOOR PLANK (C5-R7). DAMAGE EXCEEDED…
- 13 Jan 2000
Floor Panel, misdrilled
DURING A MAINTENANCE VISIT FOUND MISDRILLED HOLES, FUSELAGE, FORM NR 84 ITEM NR 3 NUMEROUS DRILLED HOLES ON FLOOR PLANK/PANEL (C5-R9). DAMAGE EXCEEDED LIMITS…
- 13 Jan 2000
Floor Panel, misdrilled
DURING A MAINTENANCE VISIT FOUND MISDRILLED HOLES, FUSELAGE, FORM NR 84 ITEM NR 1 NUMEROUS DRILLED HOLES THROUGHOUT FLOOR PANEL/PLANK (O1-R6). DAMAGE EXCEEDED…
- 13 Jan 2000
Floor Panel, misdrilled
DURING A MAINTENANCE VISIT FOUND CORROSION, FUSELAGE, FORM NR 84 ITEM NR 4 NUMEROUS DRILLED HOLES IN FLOOR PLANK/PANEL (C1-R4). DAMAGE EXCEEDED LIMITS IAW…
- 13 Jan 2000
Floor Panel, misdrilled
DURING A MAINTENANCE VISIT FOUND MISDRILLED HOLES, FUSELAGE, FORM NR 84 ITEM NR 4 NUMEROUS DRILLED HOLES ON FLOOR PANEL/PLANK (C4-R7). DAMAGE EXCEEDED LIMITS…
- 13 Jan 2000
Floor Panel, misdrilled
DURING A MAINTENANCE VISIT FOUND MISDRILLED HOLES, FUSELAGE, FORM NR 84 ITEM NR 5 NUMEROUS DRILLED HOLES ON FLOOR PANEL/PLANK. DAMAGE EXCEEDED LIMITS IAW DC-8…
- 13 Jan 2000
Floor Panel, misdrilled
DURING A MAINTENANCE VISIT FOUND MISDRILLED HOLES, FUSELAGE, FORM NR 84 ITEM NR 4 NUMEROUS DRILLED HOLES ON FLOOR PLANK (C9-R11). DAMAGE EXCEEDED LIMITS IAW…
- 13 Jan 2000
Intercostal, cracked
DURING A MAINTENANCE VISIT, FOUND A CRACKED INTERCOSTAL AND STIFFENER SHEARED RIVET AT STA 188 BL ''O'', DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED…
- 13 Jan 2000
Intercostal, damaged
DURING A MAINTENANCE VISIT, FOUND A SAW CUT IN THE INTERCOSTAL TIE AT STA 620 AND L11R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND…
- 12 Jan 2000
Skin, cracked
DURING A MAINTENANCE VISIT FOUND CRACK, FUSELAGE, SUB-FLOOR SKIN AT STA 225 LT WL 0 LEFT BL 58, CRACKED. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED,…
- 11 Jan 2000
Boss, corroded
DURING A MAINTENANCE VISIT FOUND CORROSION, RT MLG REQUIRES RE-WORK ON BOSS, LT MLG STRUT. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA…
- 11 Jan 2000
Boss, corroded
DURING A MAINTENANCE VISIT FOUND CORROSION, LT MLG STRUT, LT MLG REQUIRES RE-WORK ON BOSS. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA…
- 11 Jan 2000
Frame, misdrilled
DURING A MAINTENANCE VISIT, FOUND MISDRILLED HOLES TO THE UPPER CARGO COMPT STA 940 AND LONGERON 21R TO 21L, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED…
- 11 Jan 2000
Frame, misdrilled
DURING A MAINTENANCE VISIT, FOUND MISDRILLED HOLES IN THE UPPER CARGO COMPT FS 822 AND L21R TO L21L, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE,…
- 11 Jan 2000
Frame, misdrilled
DURING A MAINTENANCE VISIT, FOUND MISDRILLED HOLES IN THE UPPER CARGO COMPT FS 822 AND L21R TO L21L, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE,…
- 11 Jan 2000
Frame, misdrilled
DURING A MAINTENANCE VISIT, FOUND MISDRILLED HOLES IN THE UPPER CARGO COMPT FS 717 AND L21R TO L21L, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE,…
- 11 Jan 2000
Frame, misdrilled
DURING A MAINTENANCE VISIT, FOUND MISDRILLED HOLES IN THE UPPER CARGO COMPT FS 879 AND L21R TO L21L, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE,…
- 11 Jan 2000
Frame, misdrilled
DURING A MAINTENANCE VISIT, FOUND MISDRILLED HOLES IN THE UPPER CARGO COMPT FS 879 AT L21R TO L21L, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE,…
- 11 Jan 2000
Bracket, dented
DURING A MAINTENANCE VISIT, FOUND DENTS TO THE DOUBLER AND BRACKET ATTACH TO LONGERON AT THE AFT LOWER CARGO BILGE AT STA 1100 TO 1115 AND L33R, DAMAGE…
- 10 Jan 2000
Frame, misdrilled
DURING A MAINTENANCE VISIT, FOUND MISDRILLED HOLES IN THE UPPER CARGO COMPT FS 580 AND L21R TO L21L, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE,…
- 10 Jan 2000
Frame, misdrilled
DURING A MAINTENANCE VISIT, FOUND MISDRILLED HOLES IN THE UPPER CARGO COMPT FS 759 AT L21R TO L21L, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE,…
- 7 Jan 2000
Frame, misdrilled
DURING A MAINTENANCE VISIT, FOUND MISDRILLED HOLES IN THE UPPER CARGO COMPT FS 960 AND L21R TO L21L, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE,…
- 7 Jan 2000
Frame, misdrilled
DURING A MAINTENANCE VISIT, FOUND MISDRILLED HOLES IN THE UPPER CARGO COMPT AT FS 834 AND L21R TO L21L, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED…
- 6 Jan 2000
Frame, misdrilled
DURING A MAINTENANCE VISIT, FOUND MISDRILLED HOLES IN THE UPPER CARGO COMPT FS 660 AND L21R TO L21L, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE,…
- 6 Jan 2000
Frame, misdrilled
DURING A MAINTENANCE VISIT, FOUND MISDRILLED HOLES IN THE UPPER CARGO COMPT AT FS 781 AND L21R TO L21L, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED…
- 4 Jan 2000
Finger Dougler, corroded
DURING A MAINTENANCE VISIT FOUND CORROSION, FUSELAGE, BETWEEN STA 188 AND STA 108, RIGHT BL 69, WL 10 RIGHT, FINGER DOUBLER. DAMAGE EXCEEDED LIMITS IAW DC-8…
- 4 Jan 2000
Fitting, corroded
DURING A MAINTENANCE VISIT FOUND CORROSION, FUSELAGE, AT STA 188, RIGHT BL 69, WL 10 RIGHT, VERTICAL STIFFENER. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED…
- 4 Jan 2000
Frame, misdrilled
DURING A MAINTENANCE VISIT, FOUND MISDRILLED HOLES IN THE UPPER CARGO COMPT FS 620 AND L21R TO L21L, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE,…
- 4 Jan 2000
Frame, misdrilled
DURING A MAINTENANCE VISIT, FOUND MISDRILLED HOLES IN THE UPPER CARGO COMPT AT FS 798 AND L21R TO L21L, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED…
- 3 Jan 2000
Hinge, worn
DURING A MAINTENANCE VISIT FOUND EXCESSIVE PLAY, O/B UPPER LT MLG DOOR HINGE. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM…
- 3 Jan 2000
Frame, misdrilled
DURING A MAINTENANCE VISIT, FOUND MISDRILLED HOLES IN THE UPPER CARGO COMPT STA 1120 AND LONGERON 21R TO 21L, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.…
- 3 Jan 2000
Frame, misdrilled
DURING A MAINTENANCE VISIT, FOUND MISDRILLED HOLES IN THE UPPER CARGO COMPT FS 702 AND L21R TO L21L, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE,…
- 3 Jan 2000
Floorbeam, misdrilled
DURING A MAINTENANCE VISIT, FOUND NUMEROUS DRILLED HOLES IN THE AFT LWR CARGO COMPT TOP OF FLOORBEAM AT STA 640, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.…
- 30 Dec 1999
Frame, misdrilled
DURING A MAINTENANCE VISIT, FOUND MISDRILLED HOLES IN UPPER CARGO COMPT STA 1180 BETWEEN LONGERONS 21R TO 21L, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.…
- 30 Dec 1999
Frame, misdrilled
DURING A MAINTENANCE VISIT, FOUND MISDRILLED HOLES IN THE UPPER CARGO COMPT STA 1160 AND LONGERONS 21R TO 21L, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.…
- 30 Dec 1999
Frame, misdrilled
DURING A MAINTENANCE VISIT, FOUND MISDRILLED HOLES IN THE UPPER CARGO COMPT AT FS 1020 AND L21R TO L21L, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED…
- 29 Dec 1999
Frame, misdrilled
DURING A MAINTENANCE VISIT, FOUND MISDRILLED HOLES IN THE UPPER CARGO COMPT STA 1040 AND LONGERONS 21R TO 21L, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.…
- 29 Dec 1999
Frame, misdrilled
DURING A MAINTENANCE VISIT, FOUND MISDRILLED HOLES IN THE UPPER CARGO COMPT FS 280 AND L21R TO L21L, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE,…
- 29 Dec 1999
Frame, misdrilled
DURING A MAINTENANCE VISIT, FOUND MISDRILLED HOLES IN THE UPPER CARGO COMPT AT FS 1000 AND L21R TO L21L, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED…
- 28 Dec 1999
Frame, misdrilled
DURING A MAINTENANCE VISIT, FOUND MISDRILLED HOLES TO THE UPPER CARGO COMPT AT STA 1060 AND L21R TO L21L, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED…
- 28 Dec 1999
Frame, misdrilled
DURING A MAINTENANCE VISIT, FOUND MISDRILLED HOLES IN THE UPPER CARGO COMPT AT STA 1100 AND L21R TO L21L, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED…
- 28 Dec 1999
Stiffener, corroded
DURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO THE FWD LOWER CARGO COMPARTMENT RIGHT STIFFENER AT STA 550 TO 560 AND L32R, DAMAGE EXCEEDED LIMITATIONS…
- 28 Dec 1999
Frame, misdrilled
DURING A MAINTENANCE VISIT, FOUND MISDRILLED HOLES IN THE UPPER CARGO COMPT STA 520 AND L21R TO L21L, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED…
- 28 Dec 1999
Frame, misdrilled
DURING A MAINTENANCE VISIT, FOUND MISDRILLED HOLES IN THE UPPER CARGO COMPT FS 340 AND L21R TO L21L, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE,…
- 28 Dec 1999
Frame, misdrilled
DURING A MAINTENANCE VISIT, FOUND MISDRILLED HOLES IN THE UPPER CARGO COMPT FS 392 AND L21R TO L21L, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE,…
- 28 Dec 1999
Doubler, corroded
DURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO THE DOUBLER TO LONGERON IN THE AFT LOWER CARGO BILGE AT STA 1140 TO 1160 AND L35L, DAMAGE EXCEEDED…
- 23 Dec 1999
Frame, misdrilled
DURING A MAINTENANCE VISIT, FOUND MISDRILLED HOLES IN THE UPPER CARGO COMPT FS 460 AND L21R TO L21L, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE,…
- 23 Dec 1999
Frame, misdrilled
DURING A MAINTENANCE VISIT, FOUND MISDRILLED HOLES IN THE UPPER CARGO COMPT FS 400 AND L21R TO L21L, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE,…
- 23 Dec 1999
Frame, misdrilled
DURING A MAINTENANCE VISIT, FOUND MISDRILLED HOLES IN THE UPPER CARGO COMPT FS 380 AND L21R TO L21L, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE,…
- 23 Dec 1999
Frame, misdrilled
DURING A MAINTENANCE VISIT, FOUND NUMEROUS MISDRILLED HOLES IN THE UPPER CARGO COMPT FS 360 AND L21R TO L21L, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.…
- 23 Dec 1999
Frame, misdrilled
DURING A MAINTENANCE VISIT, FOUND MISDRILLED HOLES IN THE UPPER CARGO COMPT AT FS 480 AND L21R TO L21L, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED…
- 22 Dec 1999
Frame, misdrilled
DURING A MAINTENANCE VISIT, FOUND NUMEROUS MISDRILLED HOLES TO THE FRAME AT STA 270 AND L21R TO L21L, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED…
- 22 Dec 1999
Frame, misdrilled
DURING A MAINTENANCE VISIT, FOUND MISDRILLED HOLES IN THE UPPER CARGO COMPT AT STA 500 AND L21R TO L21L, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED…
- 21 Dec 1999
Frame, misdrilled
DURING A MAINTENANCE VISIT, FOUND MISDRILLED HOLES IN THE UPPER CARGO COMPT FS 440 AND L21R TO L21L, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED…
- 21 Dec 1999
Frame, misdrilled
DURING A MAINTENANCE VISIT, FOUND MISDRILLED HOLES IN THE UPPER CARGO COMPT FS 420 AND L21R TO L21L, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE,…
- 21 Dec 1999
Floorbeam, cracked
DURING A MAINTENANCE VISIT, FOUND A CRACK TO THE RT FLOORBEAM UPPER LOWER CARGO COMPT FS 235 AND XCW 69, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED…
- 13 May 1999
Jamb, torn
PER FAA RAMP INSP, METAL TORN AT UPPER SECTION OF MAIN CARGO DOOR JAMB. AIRCRAFT FERRIED TO KMQY FOR REPAIRS.
- 11 Mar 1998
Connector, failed
LEFT MAIN LANDING GEAR GREEN SAFE LIGHT WOULD NOT COME ON WHEN LANDING GEAR EXTENDED. REPLACED PLUG ON LEFT DOWN LOCK SWITCH, OP CHECKS GOOD.
- 27 Jan 1998
Vertical Gyro, malfunctioned
ON APPROACH, F/O HORIZON WENT TO 6 DEG NOSE UP - HORIZON LIGHT ON - ON GO AROUND F/O SHOWED 15 DEG NOSE UP. CAPT 5 DEG NOSE UP. REMOVED AND REPLACED NR 2 VG…
- 22 Nov 1997
Egt Indicator, failed
ON CLIMB-OUT, NR 1 EGT WENT TO 60 DEGREE. INSTALLED SERVICEABLE EGT IND IN NR 1 POS. OPS CK NORMAL ON GRD RUN-UP AT VARIOUS PWR SETTINGS.
- 20 Sep 1997
Floorbeam, corrosion
PERFORMED FOLLOW-UP INSPECTION OF FLOORBEAM AT STA 1360 AND BL 58RT, FOUND CORROSION DAMAGE BEYOND LIMITATIONS IAW DC-8 SRM. REMOVED CORROSION DAMAGE,…
- 29 May 1997
Floorbeam, corroded
DURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE ON FLOORBEAM, AT 1500 AND X=+36. TREATED AND REMOVED CORROSION FROM AREA IAW DC-8 SRM 51-1-8. FABRICATED…
- 28 May 1997
Frame, corroded
DURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE ON FRAME, AT Y=1530 BETWEEN LONGERONS 32R AND 36. *S/D* REMOVED CORRODED SECTION OF SPLICE FITTING AT…
- 20 May 1997
Frame, misdrilled
DURING A MAINTENANCE VISIT, FOUND MISDRILLED HOLE IN CUSP RADIUS, AT Y=780 AND LONGERON 21R. *S/D* FABRICATED AND INSTALLED REPAIR IAW FAA DER COTNEY…
- 20 May 1997
Floorbeam, corrosion
DURING A MAINTENANCE VISIT, FOUND LOWER AFT LEG OF TRANSVERSE FLOORBEAM SUPPORT CORRODED BEYOND LIMITATIONS, AT Y=902 AND X=-20 TO X-50. REMOVED CORROSION AND…
- 20 May 1997
Plating, corrosion
DURING A MAINTENANCE VISIT, FOUND CORROSION ON UPPER LEADING EDGE OF LEFT WING, AT XFS=32.75. *S/D* ATTACHED SCREW HOLES CORRODED BEYOND LIMITS, MATERIAL…
- 19 May 1997
Frame, misdrilled
DURING A MAINTENANCE VISIT, FOUND MISDRILLED HOLE IN FRAME RADIUS, AT Y=700 AND LONGERON 21R. FABRICATED AND INSTALLED REPAIR ANGLE AND SHIMS IAW DER APPROVED…
- 19 May 1997
Frame, misdrilled
DURING A MAINTENANCE VISIT, FOUND MIS-DRILLED HOLE IN FRAME AND FRAME INTERCOASTAL ATTACHMENT ANGLE, AT Y=1240, 14 ABOVE LONGERON 21 RIGHT. *S/D* FABRICATED…
- 19 May 1997
Frame, misdrilled
DURING A MAINTENANCE VISIT, FOUND MIS-DRILLED HOLE IN VERTICAL LEG OF FRAME AND DOUBLER, AT Y=780 AND BETWEEN LONGERONS 18R AND 20R. *S/D* FABRICATED AND…
- 19 May 1997
Frame, misdrilled
DURING A MAINTENANCE VISIT, FOUND MISDRILLED HOLE 5 PLACES JUST BELOW WINDOW, AT Y=460 AND BETWEEN LONGERONS 20R AND 21R. FABRICATED AND INSTALLED DOUBLER…
- 19 May 1997
Frame, misdrilled
DURING A MAINTENANCE VISIT FOUND MISDRILLED HOLES IN FRAME RADIUS, AT Y=1060 AND 11 ABOVE LONGERON 21L. PLUGGED HOLES WITH E RIVETS, FABRICATED AND INSTALLED…
- 19 May 1997
Floorbeam, cracked
DURING A MAINTENANCE VISIT, FOUND CRACK ON FLOORBEAM, AT Y=500 AND 6 INCHES INBD FROM LT O/B END OF BEAM TOP FLANGE. FABRICATED AND INSTALLED 1 ANGLE DOUBLER…
- 19 May 1997
Longeron, corroded
DURING A MAINTENANCE VISIT, FOUND CORROSION TO FUSELAGE SKIN AT LT REAR CARGO PIT Y=1230 TO 1240. ALSO, FOUND CORROSION ON LONGERON 31L. REMOVED FASTENERS AND…
- 19 May 1997
Frame, misdrilled
DURING A MAINTENANCE VISIT, FOUND MISDRILLED HOLES, AT Y=1240, 25 INCHES AND 3 INCHES ABOVE LONGERON 21R. FABRICATED AND INSTALLED REPAIRS IAW DER APPROVED…
- 19 May 1997
Frame, misdrilled
DURING A MAINTENANCE VISIT, FOUND MISDRILLED HOLE IN FRAME, AT Y=1140 AND 25 INCHES ABOVE LONGERON 21R. PLUGGED HOLE WITH E RIVET, FABRICATED AND INSTALLED…
- 19 May 1997
Frame, misdrilled
DURING A MAINTENANCE VISIT, FOUND MISDRILLED HOLES IN FRAME RADIUS, AT Y=1140 AND 11 INCHES ABOVE LONGERON 21L. PLUGGED 3 HOLES WITH E RIVETS, FABRICATED AND…
- 19 May 1997
Frame, misdrilled
DURING A MAINTENANCE VISIT, FOUND MISDRILLED HOLES IN FRAME RADIUS, AT Y=560 AND LONGERON 21L. PLUGGED MISDRILLED HOLES WITH E RIVETS, FABRICATED AND…
- 19 May 1997
Frame, misdrilled
DURING A MAINTENANCE VISIT, FOUND MISDRILLED HOLE IN FRAME RADIUS, AT Y=1020 AND LONGERON 21L. PLUGGED HOLE, FABRICATED AND INSTALLED REPAIR IAW DER COTNEY…
- 19 May 1997
Frame, misdrilled
DURING A MAINTENANCE VISIT, FOUND MISDRILLED HOLES IN FRAME, AT Y=1080, AND 28 INCHES ABOVE LONGERON 21L. PLUGGED HOLES WITH E RIVETS, FABRICATED AND…
- 19 May 1997
Frame, misdrilled
DURING A MAINTENANCE VISIT, FOUND MISDRILLED HOLES IN FRAME DOUBLER, AT Y=440, AND 12 INCHES ABOVE LONGERON 21R. FABRICATED AND INSTALLED REPAIR IAW DER…
- 19 May 1997
Frame, misdrilled
DURING A MAINTENANCE VISIT, FOUND MISDRILLED HOLES IN FRAME, AT Y=280 LT AND GUSSET. FABRICATED AND INSTALLED REPAIR ANGLE, 4 CLIPS AND 5 GUSSETS IAW DER…
- 19 May 1997
Frame, misdrilled
DURING A MAINTENANCE VISIT, FOUND MISDRILLED HOLES IN FRAME RADIUS, AT Y=1300 AND LONGERON 21L. PLUGGED HOLES WITH E RIVETS, FABRICATED AND INSTALLED REPAIR…
- 19 May 1997
Jamb Plate, cracked
DURING A MAINTENANCE VISIT, FOUND MAIN CARGO DOOR UPPER JAMB PLATE BROKEN OUT AND CORRODED EDGES. REMOVED DAMAGED AREA, REMOVED CORROSION AND TREATED IAW DC-8…
- 19 May 1997
Plating, cracked
DURING A MAINTENANCE VISIT, FOUND TOP PLATING OF LT LEADING EDGE CRACKED, AT XW=257.5. REMOVED DAMAGED AREA 0.85, FABRICATED AND INSTALLED 1 FILLER AND 2…
- 19 May 1997
Frame, misdrilled
DURING A MAINTENANCE VISIT, FOUND MISDRILLED HOLES IN FRAME RADIUS, AT Y=1160 AND 11 INCHES ABOVE LONGERON 21L. FABRICATED AND INSTALLED REPAIR ANGLE AND…
- 19 May 1997
Frame, misdrilled
DURING A MAINTENANCE VISIT, FOUND MISDRILLED HOLES IN FRAME RADIUS, AT Y=660 AND LONGERON 18R. PLUGGED MISDRILLED HOLES WITH E RIVETS. FABRICATED AND…
- 19 May 1997
Frame, misdrilled
DURING A MAINTENANCE VISIT, FOUND MISDRILLED HOLE THUR HI-LOK IN FRAME, AT Y=492 AND LONGERON 21R. FABRICATED AND INSTALLED REPAIR ANGLE AND SHIMS AND WEB IAW…
- 19 May 1997
Frame, misdrilled
DURING A MIANTENANCE VISIT, FOUND MISDRILLED HOLES IN FRAME RADIUS, AT Y=920 AND LONGERON 19R. PLUGGED HOLE WITH E RIVETS. FABRICATED AND INSTALLED REPAIR…
- 19 May 1997
Frame, misdrilled
DURING A MAINTENANCE VISIT, FOUND MISDRILLED HOLES IN FRAME RADIUS, AT Y=300 AND LONGERON 21L. FABRICATED AND INSTALLED REPAIR IAW DER APPROVED ENGINEERING…
- 19 May 1997
Frame, misdrilled
DURING A MAINTENANCE VISIT, FOUND MISDRILLED HOLE IN FRAME RADIUS, AT Y=798 AND LONGERON 21L. PLUGGED HOLE WITH E RIVET. FABRICATED AND INSTALLED REPAIR IAW…
- 19 May 1997
Frame, misdrilled
DURING A MAINTENANCE VISIT, FOUND MISDRILLED HOLES IN CUSP FITTING AND FRAME RADIUS, AT Y=300 AND LONGERON 21R. FABRICATED AND INSTALLED REPAIR ANGLE AND…
- 19 May 1997
Frame, misdrilled
DURING A MAINTENANCE VISIT, FOUND MISDRILLED HOLE IN FRAME AND THUR HI-LOK, AT Y=760 AND LONGERON 18R. FABRICATED AND INSTALLED REPAIR IAW DER APPROVED COTNEY…
- 19 May 1997
Frame, misdrilled
DURING A MAINTENANCE VISIT, FOUND MISDRILLED HOLES IN FRAME RADIUS, AT Y=1120 AND ABOVE LONGERON 21L. FABRICATED AND INSTALLED REPAIR IAW DER APPROVED…
- 19 May 1997
Plating, gouged
DURING A MAINTENANCE VISIT, FOUND AFT SIDE OF LT INBD FLAP GOUGED JUST ABOVE WEDGE AT Y=107 TO Y=117. CUT OUT DAMAGED AREA, FABRICATED AND INSTALLED REPAIR…
- 17 May 1997
Frame, misdriiled
DURING A MAINTENANCE VISIT, FOUND MISDRILLED HOLE IN FRAME RADIUS, AT Y=1200 AND 25 INCHES ABOVE LONGERON 21R. FABRICATED AND INSTALLED REPAIR IAW DER…
- 17 May 1997
Frame, misdrilled
DURING A MAINTENANCE VISIT, FOUND MISDRILLED HOLES IN FRAME FITTING, AT Y=800 AND LONGERON 21R. PLUGGED HOLES, FABRICATED STRAP AND SHIMS IAW DER APPROVED…
- 12 May 1997
Doubler, corrosion
DURING A MAINTENANCE VISIT, FOUND CORROSION AND BULGED AND POPPED RIVETS ON DOUBLER, AT Y=188 TO Y=208 AND X=+50. *S/D* REMOVED CORROSION FROM FINGER DOUBLER…
- 6 May 1997
Frame, cracked
DURING A MAINTENANCE VISIT, FOUND MIS-DRILLED HOLE AND CRACKED IN FRAME AND FRAME INTERCOSTAL, AT Y=1240, AND 14 INCHES ABOVE UPPER CARGO COMPARTMENT FLOOR.…
- 29 Apr 1997
Floorbeam, misdrilled
DURING A MAINTENANCE VISIT, FOUND MISDRILLED HOLE IN FLOORBEAM, AT Y=1460 AND X=-47.5. FABRICATED AND INSTALLED REPAIR IAW DER APPROVED COTNEY ENGINEERING…
- 26 Apr 1997
Skin, gouged
DURING A MAINTENANCE VISIT, FOUND INNER SKIN GOUGED, AT Y=512 AND BETWEEN LONGERONS 32R AND 33R. FABRICATED AND INSTALLED REPAIR DOUBLER IAW DER APPROVED…
- 25 Apr 1997
Floorbeam, misdrilled
DURING A MAINTENANCE VISIT, FOUND MISDRILLED HOLE IN FLOORBEAM, AT Y=1420 AND X=+18. FABRICATED AND INSTALLED REPAIR ANGLE IAW DER COTNEY ENGINEERING SKETCH…
- 23 Apr 1997
Pressure Panel, corroded
DURING A MAINTENANCE VISIT, FOUND PRESSURE PANEL CORRODED BEYOND LIMITATIONS, AT Y=920 AND X=+70. REMOVED CORROSION DAMAGE IAW DC-8 SRM 51-1-8. FABRICATED AND…
- 22 Apr 1997
Floorbeam, corrosion
DURING A MAINTENANCE VISIT, FOUND FLOORBEAM CORRODED PAST LIMITS IAW DC-8 SRM, AT Y=1440 AND X=-10.5. REMOVED AND TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED…
- 21 Apr 1997
Pressure Panel, corroded
DURING A MAINTENANCE VISIT, FOUND SUBFLOOR DOUBLER WITH 2 AREAS OF CORROSION DAMAGE, AT Y=902 TO Y=920 AND X=+4. REMOVED CORROSION DAMAGE IAW DC-8 SRM 51-1-8.…
- 20 Apr 1997
Floorbeam, corroded
DURING A MAINTENANCE VISIT, FOUND CORROSION ON FLOORBEAM DAMAGE BEYOND LIMITS IAW DC-8 SRM, AT Y=920 AND X=+49.5. REMOVED CORROSION AND TREATED IAW DC-8 SRM.…
- 19 Apr 1997
Web, misdrilled
DURING A MAINTENANCE VISIT, FOUND MIS-DRILLED HOLE IN WEB AT FWD SIDE OF X-SLIDE DOOR OPENING, AT Y=500 AND OTBD OF TRACK. *S/D* FABRICATED AND INSTALLED…
- 19 Apr 1997
Frame, misdrilled
DURING A MAINTENANCE VISIT, FOUND MISDRILLED HOLE IN WEB BETWEEN Y=492 AND Y=500 FRAME, ABOVE LONGERON 35R. REMOVED DAMAGED SECTION OF 0.25. TREATED AND…
- 19 Apr 1997
Floorbeam, buckled
DURING A MAINTENANCE VISIT, FOUND FLOORBEAM BUCKLED, AT Y=1500 AND X=+4 TO X=+15. FABRICATED AND INSTALLED REPAIR IAW DER APPROVED ENGINEERING SKETCH C44-R20.
- 18 Apr 1997
Frame, misdrilled
DURING A MAINTENANCE VISIT, FOUND MISDRILLED HOLE IN FRAME RADIUS, AT Y=1400 AND LONGERON 21L. FABRICATED AND INSTALLED REPAIR ANGLE AND SHIMS IAW DER…
- 18 Apr 1997
Frame, misdrilled
DURING A MAINTENACE VISIT, FOUND MISDRILLED HOLE IN FRAME RADIUS, AT Y=1380 AND 28 INCHES ABOVE LONGERON 21L. FABRICATED AND INSTALLED REPAIR ANGLE AND SHIMS…
- 18 Apr 1997
Fitting, corroded
DURING A MAINTENANCE VISIT, FOUND BATHTUB FITTING CORRODED BEYOND LIMITATIONS IAW DC-8 SRM, AT Y=520 AND BETWEEN LONGERONS 33R AND 34R. *S/D* REMOVED CORRODED…
- 17 Apr 1997
Frame, misdrilled
DURING A MAINTENANCE VISIT, FOUND MISDRILLED HOLE IN FRAME, AT Y=1140 AND LONGERON 21L. FABRICATED AND INSTALLED REPAIR ANGLE AND SHIMS IAW DER APPROVED…
- 17 Apr 1997
Frame, misdrilled
DURING A MAINTENANCE VISIT, FOUND MISDRILLED HOLE IN FRAME RADIUS, AT Y=1340 AND LONGERON 21R. FABRICATED AND INSTALLED REPAIR ANGLE AND SHIMS IAW DER…
- 17 Apr 1997
Frame, misdrilled
DURING A MAINTENANCE VISIT, FOUND MISDRILLED HOLES IN FRAME RADIUS AND CUSP FITTING, AT Y=1400 AND LONGERON 21R. FABRICATED AND INSTALLED REPAIR ANGLE AND…
- 17 Apr 1997
Longeron, cracked
DURING A MAINTENANCE VISIT, FOUND CRACKED WEB IN TWO PLACES ON LONGERON 21R, AT Y=280 TO Y=300. FABRICATED AND INSTALLED REPAIR IAW DER APPROVED ENGINEERING…
- 17 Apr 1997
Exhaust Nozzle, cracked
DURING A MAINTENANCE VISIT, FOUND NR 4 ENGINE NOZZLE AFT OUTSIDE SKIN CRACKED AT TOP RT FAN AIR SLOT. FABRICATED AND INSTALLED EXHAUST NOZZLE SKIN REPAIR IAW…
- 17 Apr 1997
Bulkhead Web, cut
DURING A MAINTENANCE VISIT, FOUND CUT IN BULKHEAD WEB, AT Y=980 AND X=+59. FABRICATED AND INSTALLED REPAIR IAW DER APPROVED COTNEY ENGINEERING SKETCH C44-R30.
- 17 Apr 1997
Skin, dented
DURING A MAINTENANCE VISIT, FOUND INNER SKIN DENTED BEYOND LIMITS IAW DC-8 SRM, AT Y=1240 AND BETWEEN LONGERONS 34R AND 36. REMOVED DAMAGED SECTION,…
- 16 Apr 1997
Plating, cracked
DURING A MAINTENANCE VISIT, FOUND NR 1 PLYON PLANK CRACKED, AT YN=204 RT. FABRICATED AND INSTALLED REPAIR IAW DER APPROVED ENGINEERING SKETCH C44-R03.
- 16 Apr 1997
Plating, cracked
DURING A MAINTENANCE VISIT, FOUND UPPER LEFT WING PLATING CRACKED, AT XRS=162. FABRICATED AND INSTALLED REPAIR IAW DER COTNEY ENGINEERING SKETCH C44-R41.
- 16 Nov 1995
Uplock Mech, lack of lube
KDAY/KAUS - FLT 108 - ON GEAR RETRACTION, THE GEAR DOOR LIGHT REMAINED ON. THE FLIGHT CREW CYCLED THE LANDING GEAR PER THE ABNORMAL OPERATIONS PROCEDURES AND…