1967 McDonnell Douglas DC-9-31 standard FAA →

earlier registrations

1 past record
  1. 1967

    Alameda Corp Trustee

    1967 McDonnell Douglas DC-9-31

    deregistered 19 Oct 2005 exported to Venezuela

    s/n 47135 engine P & W JT8D-9 Ser

service difficulty reports

100 reports
  1. 26 Jul 2001

    Slide

    Doug DC931

    THE LEFT SIDE NUMBER 1 CABIN DOOR ESCAPE SLIDE PRESSURE WAS LOW. REPLACED THE SLIDE. CHECK-C 5-10-01 STL. --CLOSED--

  2. 30 Jan 2001

    Switch, shorted

    Doug DC931

    WHEN CREW WAS ACCOMPLISHING THE LANDING GEAR HANDLE CHECK, SMOKE APPEARED FROM THE LANDING GEAR HANDLE SWITCH. FOUND SWITCH SHORTED. REPLACED THE SWITCH.…

  3. 27 Oct 2000

    Battery Pack, discharged

    Doug DC931

    THE EGRESS LIGHTS FOR ROWS 7 TO 14 WERE INOPERATIVE. REPLACED THE BATTERY PACK AT ROW 14. CHECK-C 4-16-00 MCI.

  4. 5 Apr 2000

    Rib, cracked

    Doug DC931

    DURING OP 16 MAINT CHECK, FOUND LT WING L/E RIB APPROX 7 INCHES I/B OF NUMBER 11 SLAT TRACK WAS CRACKED AT LOWER AFT FASTENER, AND ANOTHER CRACK 19 INCHES /B…

  5. 2 Apr 2000

    Structure, cracked

    Doug DC931

    DURING OP 16 MAINT CHECK, THE FWD ENTRY DOOR UPPER AFT STOP HOLE WAS CRACKED .5 IN FWD AND .125 IN AFT. FABRICATED DOUBLERS AND INSTALLED PER SRO 9530252.

  6. 31 Mar 2000

    Rib, damaged

    Doug DC931

    DURING OP 16 MAINT CHECK ON THE RT WING A HOLE WAS WORN IN UPPER AND LOWER FLAP RIB AT METAL SHIM BOTTOM SIDE AT FLEX JOINT APPROX 90 INCHES FROM I/B END.…

  7. 30 Mar 2000

    Skin, dented

    Doug DC931

    DURING OP 16 MAINT CHECK ON LT WING FLAP, FOUND DENT IN LOWER SURFACE TO A DEPTH OF APPROX 0.125 IN LOCATED 48 INCHES FROM I/B END, AND A SECOND DENT TO SAME…

  8. 24 Mar 2000

    Longeron, cracked

    Doug DC931

    DURING OP 16 MAINT CHECK, FOUND LONGERON 30 AT STA 584 WAS CRACKED. REPLACED LONGERON TIE PER DOUGLAS INSTALLATION DRAWING 5910068.

  9. 24 Mar 2000

    Longeron, cracked

    Doug DC931

    DURING OP 16 MAINT CHECK, FOUND LONGERON 30 CRACKED FROM ABOUT STA 582 TO 586. REPAIRED PER SRM 53-02, FIG 14.

  10. 23 Mar 2000

    Skin, damaged

    Doug DC931

    DURING OP 16 MAINT CHECK, FOUND TEMPORARY REPAIR ON RT WING I/B SKIN AT STA 154 JUST AFT OF I/B FLAP HINGE ON THE FLAP L/E. INSTALLED REPAIR PER ARA 16901.…

  11. 22 Mar 2000

    Frame, damaged

    Doug DC931

    DURING OP 16 MAINT CHECK, THE AFT RT LAV AREA HAD A TEMPORARY FORMER REPAIR AT STA 908, STRINGER 16R TO 18R. INSTALLED NEW FRAME SECTION AND SPLICED PER SRM…

  12. 21 Mar 2000

    Longeron, cracked

    Doug DC931

    DURING OP 16 MAINT CHECK, LONGERONS 28R, 29R, AND 29L AT STA 584 WERE CRACKED. REPLACED LONGERON TIE FOR EACH, (P/N 5920332-IN), PER DOUGLAS DRAWING 5910068,…

  13. 20 Mar 2000

    Frame, cracked

    Doug DC931

    DURING OP 16 MAINT CHECK, THE LT KEEL BEAM AREA, A FORMER FOOT WAS CRACKED APPROXIMATELY STA 622, BETWEEN LONGERON 28L AND 29L. REPAIRED CRACK IN FORMER FOOT…

  14. 20 Mar 2000

    Angle, cracked

    Doug DC931

    DURING OP 16 MAINT CHECK, THE RT PYLON UPPER ATTACH ANGLE WAS CRACKED, RT SIDE APPROX STA 980. CRACK RUNS FWD .25 INCH. STOP DRILLED CRACK PER SRM 34-04, FIG…

  15. 20 Mar 2000

    Skin, cracked

    Doug DC931

    DURING OP 16 MAINT CHECK, FUSELAGE SKIN WAS CRACKED AT TOP FASTENER HOLE OF FRAME, BELOW STRINGER 14R AT STA 980 RT SIDE. INSTALLED AND FINISHED REPAIR PER…

  16. 20 Mar 2000

    Keelbeam, cracked

    Doug DC931

    DURING OP 16 MAINT CHECK, KEEL BEAM CENTER WEB WAS CRACKED AT STA 618, UPPER END AT CENTER FUEL TANK LOWER SKIN. REPAIRED CRACK WEB PER ARA 16584 PAGES 1 AND 2.

  17. 16 Mar 2000

    Floorbeam, cracked

    Doug DC931

    DURING OP 16 MAINT CHECK HAD CRACK ON FITTING ON O/B FLOOR SUPPORT BEAM AT STA 996, LBL 60 INCHES. INSTALLED NEW FITTING (P/N 5913700-IN) PER 5910163 DRAWING…

  18. 14 Mar 2000

    Frame, cracked

    Doug DC931

    DURING OP 16 MAINT CHECK, THE AFT FUSELAGE FRAME AT STA 1076 WAS CRACKED AT LOWER AFT CORNER OF THE LT HEAT EXCHANGER PORT. REPAIRED CRACK IN FRAME PER SRM…

  19. 11 Mar 2000

    Skin, chafed

    Doug DC931

    DURING OP 16 MAINT CHECK AT STA 937, LT SIDE A WORN AREA IN FUSELAGE AT L/E OF LT PYLON. INSTALLED DOUBLER PER SRM 53-04 FIG 3A.

  20. 9 Mar 2000

    Angle, cracked

    Doug DC931

    DURING OP 16 MAINT CHECK AT STA 996 AND BELOW LONGERON 18L, THE BULKHEAD L-ANGLE WAS CRACKED. INSTALLED NEW PIECE OF (P/N 5910763-79) AND SPLICE PER SRM…

  21. 8 Mar 2000

    Seat Track, corroded

    Doug DC931

    DURING OP 16 MAINT CHECK, NUMBER 4 SEAT TRACK HAD CORROSION AT STA 232, RBL 44. REPLACED SECTION OF TRACK FROM STA 200 TO 284, NUMBER 4 TRACK PER SRM 53-05…

  22. 8 Mar 2000

    Floorbeam, corroded

    Doug DC931

    DURING OP 16 MAINT CHECK, FOUND FLOOR SUPPORT AT STA 200, JUST OTBD OF NUMBER 4 TRACK, HAD CORROSION. FABRICATED LIKE PART FROM 7075-T65 EXTRUSION PER IPC…

  23. 7 Mar 2000

    Intercostal, damaged

    Doug DC931

    DURING OP 16 MAINT CHECK, FOUND DEFORMED INTERCOSTAL AT STA 380, RBL 6 TO 12. REPLACED INTERCOSTAL PER SPM 6-70-01, PAGE 3, AND DOUGLAS DRAWING 5910142.

  24. 7 Mar 2000

    Intercostal, damaged

    Doug DC931

    DURING OP 16 MAINT CHECK, INTERCOSTAL WAS DEFORMED AT STA 400, RBL 6 TO 12. REPLACED INTERCOSTAL PER SPM 6-70-01, PAGE 3, AND DOUGLAS DRAWING 5910142.

  25. 6 Mar 2000

    Floorboard, cracked

    Doug DC931

    DURING OP 16 MAINT CHECK, CABIN FLOOR PANEL 11, TOP SIDE HAD CORROSION IN SEVERAL AREAS. FABRICATED NEW FLOOR PANEL USING OLD PANEL AS A TEMPLATE. USED…

  26. 6 Mar 2000

    Seat Track, corroded

    Doug DC931

    DURING OP 16 MAINT CHECK, NUMBER 3 CABIN FLOOR TRACK HAD CORROSION AT STA 216, RBL 22 INCHES. REPLACED NUMBER 3 SEAT TRACK FROM STA 216 TO STA 266 EXISTING…

  27. 6 Mar 2000

    Floorbeam, cracked

    Doug DC931

    DURING OP 16 MAINT CHECK, AT CABIN STA 200 RT, STRINGER 18, FLOOR MEMBRANE WAS CRACKED AND HEAVLY CORRODED. REMOVED MEMBRANE AND FABRICATED NEW MEMBRANE PER…

  28. 5 Mar 2000

    Intercostal, misdrilled

    Doug DC931

    DURING OP 16 MAINT CHECK, INTERCOSTAL WAS DEFORMED AND HAD MISDRILLED HOLES AT STA 350 TO 370, RBL 6 INCHES. REPLACED INTERCOSTAL PER 6-70-01, PAGE 3 AND…

  29. 4 Mar 2000

    Seat Track, corroded

    Doug DC931

    DURING OP 16 MAINT CHECK, FOUND TRACK CORRODED ON INSIDE AT STA 237 TO 304, NUMBER 2 TRACK LBL 22 INCHES. INSTALLED NUMBER 2 TRACK SPLICE AT STA 200 TO 322,…

  30. 4 Mar 2000

    Floorbeam, cracked

    Doug DC931

    DURING OP 16 MAINT CHECK, FOUND FLOOR MEMBRANE CRACKED AT STA 592, RBL 40 IN TO 48 IN. STOP DRILLED, INSTALLED DOUBLER PER SRM 53-01, PAGE 9.

  31. 4 Mar 2000

    Intercostal, damaged

    Doug DC931

    DURING OP 16 MAINT CHECK, INTERCOSTAL WAS DEFORMED AT STA 409, RBL 6 TO 12. REPLACED INTERCOSTAL PER SPM 6-70-01, PAGE 3, AND DOUGLAS DRAWING 5910142.

  32. 4 Mar 2000

    Intercostal, damaged

    Doug DC931

    DURING OP 16 MAINT CHECK, INTERCOSTAL WAS DEFORMED AT STA 389, RBL 6 TO 12. REPLACED INTERCOSTAL PER SPM 6-70-01, PAGE 3, AND BOEING DRAWING 5910142.

  33. 3 Mar 2000

    Intercostal, misdrilled

    Doug DC931

    DURING OP 16 MAINT CHECK, INTERCOSTAL WAS DEFORMED AND HAD MISDRILLED HOLES AT STA 370 TO 427, RBL 6. REPLACED INTERCOSTAL PER SPM 6-70-1, PAGE 3 AND DOUGLAS…

  34. 3 Mar 2000

    Floorbeam, corroded

    Doug DC931

    DURING OP 16 MAINT CHECK, FLOOR WEB AT STA 200 TO 218, BL 0 AND LBL 56, HAD CORROSION ON TOP SIDE OF WEB. REPLACED FLOOR MEMBRANE FROM LBL 20 TO BL 0 WITH…

  35. 3 Mar 2000

    Seat Track, corroded

    Doug DC931

    DURING OP 16 MAINT CHECK, NUMBER 1 CABIN FLOOR TRACK HAD CORROSION FROM STA 200 TO 237. TREATED METAL PER SRM 51-10-03. REPLACED NR 1 TRACK AND SPLICE FROM…

  36. 1 Mar 2000

    Hinge, cracked

    Doug DC931

    DURING OP 16 MAINT CHECK, THE RT WING SUPPORT STRUCTURE INSIDE OF THE FLAP OTBD IDLE HINGE WAS CRACKED INBD AND OTBD SIDE.. INSTALLED INBD AND OTBD RIBS PER…

  37. 1 Mar 2000

    Longeron, cracked

    Doug DC931

    DURING OP 16 MAINT CHECK, LONGERON 17L WAS CRACKED AT THE AFT SIDE OF STA 965 BULKHEAD. REPLACED LONGERON 17L FROM STA 955 TO 996 PER DRAWING 5911427.…

  38. 1 Mar 2000

    Floorbeam, corroded

    Doug DC931

    DURING OP 16 MAINT CHECK, FOUND CORROSION ON FLOOR SUPPORT ANGLE, STA 200 LBL 0 TO 20 INCHES. INSTALLED NEW FLOOR SUPPORT MADE FROM TWA PN S2652479-1200, WITH…

  39. 1 Mar 2000

    Floorbeam, corroded

    Doug DC931

    DURING OP 16 MAINT CHECK AT STA 200 AND BL 0 TO LBL 24 INCHES, FOUND HEAVY CORROSION AND SEALANT INSTALLED ON FLOOR WEB. PARTIAL MEMBRANE REMOVED. REPLACED…

  40. 1 Mar 2000

    Floorbeam, corroded

    Doug DC931

    DURING OP 16 MAINT CHECK, FLOOR SUPPORT WEB AT STA 160 TO 200 HAD LIGHT CORROSION, LB 0 TO LBL 24. REMOVED CORROSION FROM BL 0 TO LBL 24 PER SPM 6-80-1 AND…

  41. 1 Mar 2000

    Floorbeam, corroded

    Doug DC931

    DURING OP 16 MAINT CHECK, CABIN FLOOR WEB STA 160 TO 200 AND LBL 22 IN TO LBL 43 INCHES HAD LIGHT CORROSION TOP OF WEB. REMOVED MEMBRANE CORRODED AREA FROM…

  42. 1 Mar 2000

    Floorbeam, corroded

    Doug DC931

    DURING OP 16 MAINT CHECK, FOUND HEAVY SEALANT OVER CORRODED FLOOR WEB AT STA 218, LBL 0 TO 12 INCHES. REPLACED FLOOR MEMBRANE FROM BL 0 TO LBL 20 IN WITH…

  43. 1 Mar 2000

    Structure, cracked

    Doug DC931

    DURING OP 16 MAINT CHECK, THE SUPPORT STRUCTURE IN SIDE OF RT WING FLAP OTBD IDLE HINGE WAS CRACKED AT INBD AND OTBD SIDE. INSTALLED INBD AND OTBD RIBS PER…

  44. 29 Feb 2000

    Floorbeam, canning

    Doug DC931

    DURING OP 16 MAINT CHECK, THE CABIN FLOOR WEB AT STA 160 TO 200 WAS OIL CANNING AND STRETCHED EXCESSIVELY, BL 0 AND LBL 42 INCHES. INSTALLED NEW MEMBRANE FROM…

  45. 29 Feb 2000

    Web, corroded

    Doug DC931

    DURING OP 16 MAINT CHECK, FOUND SEVERE CORROSION AT STA 220, RBL 58, THE RT SIDE CUSP ANGLE. REPAIRED PER SRM CUSP ANGLE CORROSION REPAIR 53-05, PAGE 141 AND…

  46. 29 Feb 2000

    Splice, corroded

    Doug DC931

    DURING OP 16 MAINT CHECK CUSP ANGLE SPLICE HAD CORROSION AT STA 210 RT. NEW SPLICE MADE PER CUSP ANGLE CORROSION REPAIR, SRM 53-05, PAGE 141. --CLOSED---

  47. 29 Feb 2000

    Floorbeam, corroded

    Doug DC931

    DURING OP 16 MAINT CHECK, CABIN FLOOR SUPPORT AT LBL 46 TO LBL 56 HAD HEAVY CORROSION. REPLACED FLOOR SUPPORT AT STA 200 FROM LBL 46 TO 56 WITH RIVETS PER SRM…

  48. 29 Feb 2000

    Floorbeam, corroded

    Doug DC931

    DURING OP 16 MAINT CHECK, FOUND HEAVY CORROSION AT STA 200, LBL 24 AND LBL 43. INSTALLED NEW FLOOR SUPPORT WITH RIVETS PER SRM 51-30-2. PATTERN FROM OLD PART.…

  49. 28 Feb 2000

    Skin, cracked

    Doug DC931

    DURING OP 16 MAINT CHECK AT THE AFT RIGHT LAVATORY, THE FUSELAGE SKIN WAS CRACKED AT FASTENER HOLES AT STA 965 FRAME BELOW LONGERON 16R. REPAIRED CRACKED SKIN…

  50. 28 Feb 2000

    Floorbeam, cracked

    Doug DC931

    DURING OP 16 MAINT CHECK, THE FLOORBEAM DOUBLER WAS CRACKED AT STA 180, LBL 19 TO 54. REPAIRED PER SRM 53-05, PAGE 224 AND DOUGLAS PRINT 9923484.

  51. 28 Feb 2000

    Floorbeam, cracked

    Doug DC931

    DURING OP 16 MAINT CHECK, THE FLOORBEAM DOUBLER WAS CRACKED AT STA 180, LBL 19 TO BL 0. REPAIRED PER SRM 53-05, PAGE 224, AND DOUGLAS PRINT 99223484.

  52. 28 Feb 2000

    Floorbeam, corroded

    Doug DC931

    DURING OP 16 MAINT CHECK, FLOOR WEB HAD CORROSION AT STA 20, LBL 48 INCHES, BELOW FWD END OF CHAIR TRACK. REMOVED CORROSION PER SPM 6-80-1. INSTALLED NEW…

  53. 25 Feb 2000

    Door Frame, cracked

    Doug DC931

    DURING OP 16 MAINT CHECK, THE LT FWD OVERWING EMERGENCY EXIT FRAME IN THE FUSELAGE WAS CRACKED ON THE FWD AND AFT SIDE OF THE EXIT DOOR UPPER LATCH FITTING.…

  54. 25 Feb 2000

    Door Frame, cracked

    Doug DC931

    DURING OP 16 MAINT CHECK, THE LT AFT OVERWING EXIT FRAME IN THE FUSELAGE WAS CRACKED ON THE FWD AND AFT SIDE OF THE EXIT DOOR UPPER LATCH FITTING. STOP…

  55. 24 Feb 2000

    Stringer, cracked

    Doug DC931

    DURING OP 16 MAINT CHECK, AT THE AFT RT LAV, STRINGER 16R WAS CRACKED AT BOTTOM FASTENER AT AFT SIDE OF 965 BULKHEAD. REPLACED LONGERON 16R FROM STA 955 TO…

  56. 22 Feb 2000

    Skin, cracked

    Doug DC931

    DURING OP 16 MAINT CHECK, FOUND FUSELAGE SKIN CRACKED AT FASTENER HOLE OF STA 965 FRAME AND BELOW STRINGER 16R. REPAIRED CRACKED SKIN PER SRM 53-04, PAGE 93…

  57. 19 Feb 2000

    Bracket, cracked

    Doug DC931

    DURING OP 16 MAINT CHECK, THE BULKHEAD BRACKET WAS CRACKED AT STA 148 BELOW LONGERON 3L. FABRICATED AND INSTALLED NEW BRACKET PER SPM 6-70-01, PAGE 3 AND DAC…

  58. 17 Feb 2000

    Floorbeam, corroded

    Doug DC931

    DURING OP 16 MAINT CHECK, FOUND CORROSION ON TOP OF FLOOR WEB, FWD SIDE OF FLOOR SUPPORT ON AFT SIDE, STA 200, BL-0, LBL 52. REMOVED CORROSION BY REMOVING…

  59. 16 Feb 2000

    Frame, damaged

    Doug DC931

    DURING OP 16 MAINT CHECK, FOUND TEMPORARY FORMER REPAIR AT STA 980, STRINGER 16L TO 18L. REPLACED FORMER FRAME WITH NEW PER TWA SP. INSTALLED FRAME SPLICE…

  60. 15 Feb 2000

    Longeron, cracked

    Doug DC931

    DURING OP 16 MAINT CHECK, LONGERON 2L WAS CRACKED AT STA 200. REPAIRED LONGERON PER SRM 53-02, FIG 18.

  61. 13 Feb 2000

    Floorbeam, corroded

    Doug DC931

    DURING OP 16 MAINT CHECK, FOUND CORROSION ON MEMBRANE, LT SIDE BETWEEN STA 851 AND 870. TREATED, PRIMED AND PAINTED ALL AREAS WORKED PER 51-10-03. INSTALLED…

  62. 13 Feb 2000

    Floorbeam, corroded

    Doug DC931

    DURING OP 16 MAINT CHECK, FOUND CORROSION ON MEMBRANE BETWEEN STA 870 AND 889. INSTALLED ALUMINUM ALOY REPAIR PER SRM 53-01, PAGE 9. TREATED, PRIMED, AND…

  63. 11 Feb 2000

    Floorbeam, corroded

    Doug DC931

    DURING OP 16 MAINT CHECK, FOUND LIGHT CORROSION ON TOP OF FLOOR WEB, LBL 44 IN TO 56 IN, STA 160 TO 200. REMOVED CORROSION AND PRIMED AREA PER SRM 51-10-3.

  64. 10 Feb 2000

    Intercostal, cracked

    Doug DC931

    DURING OP 16 MAINT CHECK, FOUND RT SIDE INTERCOSTAL CRACKED AT 2 CENTER NUT PLATE HOLES, STA 579 TO 598. REPLACED PART PER SPM 6-70-01, PAGE 1 ITEM 1, AND SRM…

  65. 10 Feb 2000

    Floorbeam, corroded

    Doug DC931

    DURING OP 16 MAINT CHECK, THE AFT CARGO COMPT LT FLOOR SUPPORT STRAP AT LBL 17 WAS CORRODED BEYOND LIMITS FROM STA 756 TO 927. INSTALLED NEW STRAP PER SRM…

  66. 8 Feb 2000

    Longeron, cracked

    Doug DC931

    DURING OP 16 MAINT CHECK, FOUND CABIN LONGERON 3L CRACKED AT STA 160. REPAIRED PER SRM 53-02, FIG 18.

  67. 6 Feb 2000

    Fitting, cracked

    Doug DC931

    DURING OP 16 MAINT CHECK FOUND CRACK ON FITTING, O/B FLOOR SUPPORT BEAM AT STA 996, RBL 60 INCHES. INSTALLED NEW FITTING (P/N 5913700-24) WITH HI-LOKS PER SPM…

  68. 5 Feb 2000

    Bulkhead, gouged

    Doug DC931

    DURING OP 16 MAINT CHECK FOUND GOUGE IN FWD SIDE OF AFT PRESSURE BULK HEAD SKIN BELOW LONGERON 2L. REMOVED FASTENER AND BLENDED GOUGE PER SRM 53-01 FIG 1 AND…

  69. 5 Feb 2000

    Intercostal, cracked

    Doug DC931

    DURING OP 16 MAINT CHECK FOUND AT BL 0 JUST AFT OF CABIN FLOOR BEAM, STA 965, INTERCOSTAL WAS CRACKED AT UPPER FWD CORNER. INTERCOSTAL WAS FABRICATED AND…

  70. 2 Feb 2000

    Longeron, cracked

    Doug DC931

    DURING OP 16 MAINT CHECK FOUND LONGERON 4L CRACKED AT STA 200. REMOVED AND REPLACED LONGERON PER DRAWING 5911406.

  71. 2 Feb 2000

    Longeron, cracked

    Doug DC931

    DURING OP 16 MAINT CHECK FOUND LONGERON 4L CRACKED AT STA 160. REMOVED AND REPLACED LONGERON PER DRAWING 5911406.

  72. 31 Jan 2000

    Frame, cracked

    Doug DC931

    DURING OP 16 MAINT CHECK, FOUND CRACK ON TWO RIVETS ON MEMBRANE 2 IN AFT OF RT FORMER RING, STA 775 BELOW FLOOR. INSTALLED ALUMINUM ALLOY DOUBLER REPAIR PER…

  73. 28 Jan 2000

    Vane, damaged

    Doug DC931

    DURING OP 16 MAINT CHECK ON THE RT WING FOUND REPAIR ON FLAP INBD FIXED VANE SEGMENT AT LE THAT NEEDED TO BE REPLACED. INSTALLED HOT BOND REPAIR PER SRM…

  74. 26 Jan 2000

    Panel, damaged

    Doug DC931

    DURING OP 16 MAINT CHECK, A PREVIOUS REPAIR WAS FOUND ON THE RT WING FIXED T/E PANEL ASSY (P/N 5920521-2) UPPER O/B SKIN PANEL INTERIOR. INSTALLED DOUBLER PER…

  75. 26 Jan 2000

    Panel, damaged

    Doug DC931

    DURING OP 16 MAINT CHECK, ENGINEERING REQUESTED ACCOMPLISH PERMANENT REPAIR TO FIXED RT WING UPPER TRAILING EDGE PANEL ASSY (P/N 5920521-2). INSTALLED DOUBLER…

  76. 26 Jan 2000

    Frame, cracked

    Doug DC931

    DURING OP 16 MAINT CHECK, FOUND MEMBRANE CRACKED AND CORRODED AROUND RIVETS ON AFT SIDE OF RT FORMER RING, STA 813. MADE ALUM ALLOY REPAIR PER SRM 53-01, PAGE…

  77. 26 Jan 2000

    Skin, dented

    Doug DC931

    DURING OP 16 MAINT CHECK, FOUND ON LT WING FLAP, A DENT IN LOWER SURFACE APPROX 65 IN FROM I/B END AND APPROX 37 IN FROM T/E APPROX 0.125 INCHES DEEP, LENGTH…

  78. 25 Jan 2000

    Skin, cracked

    Doug DC931

    DURING OP 16 MAINT CHECK, THE LT TOP NOSE FUSELAGE SKIN WAS CRACKED AT 5 RIVETS, STA 69.550, 15 IN LBL TO 20 IN LBL. TRIMMED DAMAGED AREA AND ADDED REPAIR…

  79. 25 Jan 2000

    Skin, cracked

    Doug DC931

    DURING OP 16 MAINT CHECK, THE TOP NOSE SKIN WAS CRACKED AT RIVET RT STA 76.550, RBL 18. REMOVED DAMAGED AREA PER DOUGLAS DRAWING SRO 9530239. INSTALLED REPAIR…

  80. 25 Jan 2000

    Support, cracked

    Doug DC931

    DURING OP 16 MAINT CHECK, FOUND VERTICAL SUPPORT (P/N 9957860-6) WAS CRACKED AT STA 69.55. REMOVED DAMAGED VERTICAL SUPPORT AND INSTALLED NEW SUPPORT PER SRO…

  81. 25 Jan 2000

    Skin, cracked

    Doug DC931

    DURING OP 16 MAINT CHECK, FOUND LT TOP NOSE FUSELAGE SKIN WAS CRACKED AT 4 RIVETS STA 76.550, 16 IN LBL TO 20 IN LBL. TRIMMED DAMAGED AREA AND ADDED REPAIR…

  82. 25 Jan 2000

    Skin, cracked

    Doug DC931

    DURING OP 16 MAINT CHECK, THE TOP NOSE SKIN WAS CRACKED AT RIVET RT STA 76.550, RBL 15. REMOVED DAMAGED AREA PER DOUGLAS DRAWING SRO 9530239 AND INSTALLED…

  83. 25 Jan 2000

    Frame, cracked

    Doug DC931

    DURING OP 16 MAINT CHECK, FOUND MEMBRANE CRACKED AND CORRODED 1.5 IN FWD OF RT FORMER RING, STA 813 BELOW FLOOR. MADE ALUM ALLOY REPAIR PER SRM 53-01, PAGE 9.…

  84. 21 Jan 2000

    Door Jam, corroded

    Doug DC931

    DURING OP 16 MAINT CHECK THE AFT CARGO COMPT DOOR JAM, AFT INTERIOR SURFACE HAD LIGHT CORROSION. REPAIRED DAMAGED SECTION OF WEB AT AFT DOOR JAM PER SRM 53-01…

  85. 21 Jan 2000

    Floor Panel, corroded

    Doug DC931

    DURING OP 16 MAINT CHECK FOUND CABIN FLOOR PANEL 71 CORRODED. MADE NEW FLOOR PANEL PER SSRM 53-00-104 PAGE 201.

  86. 20 Jan 2000

    Stiffener, cracked

    Doug DC931

    DURING OP 16 MAINT CHECK FOUND CRACK IN UPPER END OF VERTICAL STIFFENER AT STA 1019, APU ENCLOSURE LEFT SIDE. REMOVED STIFFENER AND SENT TO WELDING SHOP.…

  87. 17 Jan 2000

    Intercostal, cracked

    Doug DC931

    DURING OP 16 MAINT CHECK FUSELAGE STA 40, LBL 12 IN, TOP NOSE SKIN AREA, INTERCOSTAL HAD CRACK APPROX 5 IN LONG RUNING ANGULAR. REPLACED 9957899-3 INTERCOSTAL…

  88. 14 Jan 2000

    Floor Panel, cracked

    Doug DC931

    DURING OP 16 MAINT CHECK, FLOOR PANEL NUMBER 61 HAD 2 EA CRACKED HAT SECTIONS AT AFT END. REMOVED 4 HAT SECTIONS AND REPLACED WITH 4 NEW HAT SECTIONS PER SSRM…

  89. 11 Jan 2000

    Floorbeam, corroded

    Doug DC931

    DURING OP 16 MAINT CHECK, FOUND CORROSION ON FLOOR SUPPORT RAIL AT STA 446, WAS BLENDED OUT OF LIMITS. FABRICATED 40 IN SECTION USING OLD FLOOR SUPPORT AS…

  90. 18 Jun 1999

    Battery Pack, discharged

    Doug DC931

    FOUND CABIN EGRESS LIGHTS INOPERATIVE FROM ROW 7 TO 14, AND ROW 22 TO AFT CABIN. ACCOMPLISHED A SPLICE TO A CUT FEEDER CABLE FOR ROWS 7 TO 9. REPLACED A FLEX…

  91. 12 Feb 1999

    Power Supply, inop

    Doug DC931

    THE AFT OVERWING EMERGENCY EXIT LIGHT WAS INOPERATIVE. REPLACED THE POWER SUPPLY. CHECK-C 6-25-98 STL.

  92. 26 Jun 1998

    Light, shorted

    Doug DC931

    STL - FLT 579 - FIRST OFFICER'S LIGHT ON YOKE STARTED TO SMOKE AND ARC. REPLACED CHART HOLDER. CHECK-C 6-13-98 STL. (X)

  93. 8 Apr 1998

    Skin, damaged

    Doug DC931

    MCI - DURING OP 15 MAINTENANCE CHECK, FOUND TEMPORARY REPAIR 3 INCHES BY 6 INCHES AT APPROX FS 985 BETWEEN L22R AND L23R. INSTALLED REPAIR PER ARA 11690 AND…

  94. 14 May 1997

    Power Supply, inoperative

    Doug DC931

    STL - FLT 333 - DURING LAYOVER MAINTENANCE CHECKED, LEFT EMERGENCY NACELLE LIGHT WOULD NOT ILLUMINATE. REMOVED AND REPLACED POWER SUPPLY, MFG P/N 60-1177-9LB,…

  95. 8 Apr 1997

    Skin, buckled

    Doug DC931

    MCI - DURING OP 15 MAINTENANCE CHECK, FOUND FUSELAGE SKIN OIL CANNED OR BUCKLED AT L16R TO L18R, FS 1005. REPAIRED OIL CANNED SKIN WITH A .050 DOUBLER PER SRM…

  96. 8 Apr 1997

    Bulkhead, cracked

    Doug DC931

    MCI - DURING OP 15 MAINTENANCE CHECK, FOUND AT BS 996, THE AFT PRESS BULKHEAD 'T' CAP ANGLE FROM FLOOR TO STRINGER 19R HAD CRACK. REPLACED ANGLE PER SRM…

  97. 8 Apr 1997

    Frame, corroded

    Doug DC931

    MCI - DURING OP 15 MAINTENANCE CHECK FOUND CORROSION ON AFT SIDE OF STA 963 FORMER RING, BETWEEN STA 29R AND 29L. REMOVED CORROSION PER SRM 51-103, PARA 31 TO…

  98. 13 Jul 1996

    Power Supply, discharged

    Doug DC931

    STL - DURING CRUISE, EGRESS LIGHTS AT SEAT ROW 15 TO 20 ILLUMINATED. FOUND POWER SUPPLY, MFG P/N 5822-2, WEAK. REPLACED POWER SUPPLY. OPERATION THEN CHECKED…

  99. 4 Jul 1996

    Battery Pack, discharged

    Doug DC931

    STL - DURING CRUISE, FLOOR EGRESS LIGHTING STRIP ILLUMINATED AT ROWS 14 TO 20. DISCONNECTED, CLEANED AND RECONNECTED BATTERY PACK AT ROWS 14 TO 20.…

  100. 18 Mar 1995

    Cylinder, cracked

    Doug DC931

    STL - AFTER TAKEOFF LEFT MAIN LANDING GEAR UNSAFE AND GEAR DOOR OPEN LIGHTS REMAINED ILLUMINATED WITH GEAR HANDLE IN THE UP POSITION. FOUND LEFT MAIN LANDING…

Copied daily from public FCC, FAA and NTSB downloads. Not affiliated with any of them.

sources and dates
sourcerecordsas of
FCC amateur1,702,05624 Nov 2026
FCC GMRS633,27224 Nov 2026
FCC ship radio403,52022 Nov 2026
FCC antenna structures198,13522 Nov 2026
FCC aircraft radio153,38322 Nov 2026
FAA airmen910,1651 Nov 2026
FAA deregistered aircraft383,84423 Nov 2026
FAA registered aircraft319,59223 Nov 2026
FAA N-number reservations126,12623 Nov 2026
FAA dealers12,51023 Nov 2026
FAA airports19,43329 Oct 2026
FAA service difficulty reports1,699,33524 Nov 2026
NTSB accidents, 1982 on88,0301 Nov 2026

History is kept: records the agencies stop publishing stay here, marked with the date they left.

Airmen who keep their address private aren't in the FAA's download, so they aren't here.

Not a consumer report: don't use it to screen anyone for a job, a lease, credit or insurance.

To hide your address here, email george.main@gemiv.net.