N977Z
1968 McDonnell Douglas DC-9-31 standard FAA →
earlier registrations
1 past record
- 1968
service difficulty reports
59 reports
- 4 Oct 2000
Skin, cracked
DURING OP 15 MAINT CHECK THE FUSELAGE HAD A 2 INCH CRACK AND ONE FASTENER MISSING AT STA 332 BETWEEN LONGERON 30 AND 29R. REPAIRED PER SRM 53-04, FIG 44, AT…
- 5 Sep 2000
Floor Panel, corroded
DURING OP 15 MAINT CHECK FOUND ON CABIN FLOOR, CORROSION ON FLOOR PANEL NUMBER 14. NEW FLOOR PANEL MADE PER SSRM 53-00-104, PAGE 201, AND PAINTED.
- 25 Aug 2000
Frame, misrepaired
DURING OP 15 MAINT CHECK, FOUND IN AFT CABIN RT SIDE, AT STA 980, LONGERON 16R, A FRAME REPAIR NOT APPROVED FOR THIS OPERATION. REPLACED FRAME SECTION PER…
- 21 Aug 2000
Floor Panel, corroded
DURING OP 15 MAINT CHECK FOUND CORROSION ON COCKPIT FLOOR PANEL, STA 149 AT RT EDGE LONGERON 18R. REMOVED CORRODED MEMBRANE AND REPLACED WITH 0.032 7075T6 PER…
- 21 Aug 2000
Frame, cracked
DURING OP 15 MAINT CHECK ON RT SIDE OF CABIN, STA 699, A FORMER CASTING HAD A CRACK APPROX 3 INCHES LONG IN AFT LOWER I/B FLANGE, CONFIRMED BY NDT. REMOVED…
- 21 Aug 2000
Frame, cracked
DURING OP 15 MAINT CHECK ON RT SIDE OF CABIN, STA 718, FORMER CASTING HAD A CRACK APPROX 4 INCHES LONG ON FWD LOWER I/B FLANGE, CONFIRMED BY NDT. REMOVED AND…
- 17 Aug 2000
Door Frame, cracked
DURING OP 15 MAINT CHECK, ON THE AFT BULKHEAD DOOR, FOUND A CRACK IN DOOR FRAME APPROX 6 INCHES LONG AT LT AFT EDGE, 35 INCHES ABOVE BOTTOM OF DOOR. REPLACED…
- 14 Aug 2000
Web, cracked
DURING OP 15 MAINT CHECK, THE AFT BULKHEAD DOOR, CENTER DOOR PRESSURE STOP INTERIOR WEB WAS CRACKED AT O/B AND I/B CUT OUT AT PRESSURE STOP FITTING. REPAIRED…
- 14 Aug 2000
Fitting, cracked
DURING OP 15 MAINT CHECK, ON AFT BULKHEAD DOOR, CENTER DOOR PRESSURE STOP INTERIOR FITTING WAS CRACKED. REPLACED CRACKED FITTING (P/N 4917851-501), PER SRM…
- 11 Aug 2000
Floor Panel, corroded
DURING OP 15 MAINT CHECK, FOUND CORROSION ON FLOOR PANELS 12 AND 22. MADE NEW PANELS IN SHOP PER SSRM 53-00-104.
- 11 Aug 2000
Floor Panel, corroded
DURING OP 15 MAINT CHECK, FLOOR PANEL NUMBER 11 AT FWD ENTRY DOOR HAD AREAS AROUND SCREW HOLES BLENDED BEYOND LIMIT. PANEL MADE NEW IN SHOP PER SSRM 53-00-104.
- 10 Aug 2000
Floorbeam, corroded
DURING OP 15 MAINT CHECK HAD CORROSION ON SHORT FLOORBEAM AT STA 200, LBL 44 IN TO LBL 56 INCHES. MECHANICALLY REMOVED CORROSION PER SPM 6-80-01. REMOVED…
- 9 Aug 2000
Floor Support, corroded
DURING OP 15 MAINT CHECK, FOUND CORROSION ON FLOOR SUPPORT FROM STA 160 TO 200, LBL 44. REMOVED CORRODED PART AND REPLACED PER SRM 53-11-1, FIG 11 SHEET 1 AND…
- 9 Aug 2000
Floorbeam, corroded
DURING OP 15 MAINT CHECK THE FWD ENTRY AREA HAD CORROSION ON FLOOR SUPPORT BEAM AT STA 200, LBL 0 TO 20 INCHES. FABRICATED AND REPLACED CORRODED PART PER SRM…
- 9 Aug 2000
Seat Track, corroded
DURING OP 15 MAINT CHECK, THE FLOOR TRACK BETWEEN FLOOR PANEL 14 AND 15 WAS CORRODED AT LBL 22 INCHES FROM STA 200 TO 229. REPLACED SEAT TRACK PER SRM 53-05…
- 7 Aug 2000
Seat Track, corroded
DURING OP 15 MAINT CHECK, FOUND CHAIR TRACK CORROSION AT STA 598 TO 639, STA 639 TO 699, 699 TO 756, 756 TO 813, 813 TO 870, AND 870 TO 965 ALL AT RBL 22…
- 5 Aug 2000
Strap, corroded
DURING OP 15 MAINT CHECK, FOUND CORROSION RUST ON WINDOW FRAME STRAP LOWER AFT END OF CAPT SLIDING WINDOW. REMOVED CORROSION FROM FRAME PER DRAWING 5912350.…
- 5 Aug 2000
Frame, corroded
DURING OP 15 MAINT CHECK, FOUND RUST ON LOWER AFT END OF F/O SLIDING WINDOW FRAME. REMOVED CORROSION PER DRAWING 5912350. MANUFACTURED NEW PART AND SENT TO…
- 5 Aug 2000
Attach Angle, corroded
DURING OP 15 MAINT CHECK, FOUND CORROSION ON FLOOR ATTACH ANGLE AT AFT PRESSURE BULKHEAD, STA 996 BETWEEN LONGERONS 24L AND 24R. REMOVED CORROSION FROM AREA…
- 1 Aug 2000
Floor Support, corroded
DURING OP 15 MAINT CHECK, THE FWD ENTRY AREA, THE FLOOR CENTER SUPPORT BEAM HAD CORROSION AROUND SCREW HOLES FROM STA 160 TO 218, BL 0. FABRICATED NEW PART…
- 29 Jul 2000
Seat Track, corroded
DURING OP 15 MAINT CHECK, FOUND MEMBRANE BADLY CORRODED O/B OF NUMBER 1 CHAIR TRACK, STA 218 TO 237. REMOVED DAMAGED SECTION OF WEB. MADE NEW IN SHOP PER SRM…
- 29 Jul 2000
Seat Track, corroded
DURING OP 15 MAINT CHECK, FOUND CORROSION ON FLOOR TRACK AT LBL 44 FROM STA 200 TO 229, BETWEEN FLOOR PANEL 15 AND 16. REMOVED DAMAGED TRACK AND REPLACED PER…
- 28 Jul 2000
Longeron, cracked
DURING OP 15 MAINT CHECK, LONGERON 27L FORMER FOOT WAS CRACKED ON THE FWD END OF STA 579. REMOVED AND REPLACED STRINGER FITTING PER SRM 51-01, PAGE 1 ITEM C.
- 28 Jul 2000
Web, chafed
DURING OP 15 MAINT CHECK, FOUND FLOOR MEMBRANE HAD RUBBED THROUGH AT STA 200, BL 0 TO LBL 24 IN. REPAIRED PER SRM 53-01, PAGE 9 FIG 2.
- 27 Jul 2000
Web, corroded
DURING OP 15 MAINT CHECK, FOUND CORROSION ON FLOOR MEMBRANE AT STA 598 TO 617, LT SIDE OF FUSELAGE. REMOVED CORROSION PER SPM 6-80-1.
- 27 Jul 2000
Web, cracked
DURING OP 15 MAINT CHECK, FOUND CRACKS IN FLOOR MEMBRANE AT STA 617 TO 615, LBL 54. INSTALLED WEB REPAIR PER SRM 53-01, PAGE 9 FIG 2 SHEET 3.
- 27 Jul 2000
Fastener, missing
DURING OP 15 MAINT CHECK, FOUND FASTENERS MISSING AT LBL 58, STA 598 TO 617. INSTALLED HI-LOKS PER SRM 51-30-05. FASTENERS REMOVED AND REPLACED TO FACILITATE…
- 26 Jul 2000
Skin, corroded
DURING OP 15 MAINT CHECK, FOUND CORROSION ON CENTER WING UPPER SKIN AT STA 689, LBL 25 IN TO LBL 58. CLEANED AND REMOVED CORROSION FROM AREA PER SPM 6-80-1.…
- 26 Jul 2000
Pan, cracked
DURING OP 15 MAINT CHECK, THE LT FWD ENTRY DOOR HAD A CRACK IN THE DOOR PAN UNDER THE LOWER FWD DOOR PRESSURE STOP. REMOVED AND REPLACED DOOR PAN (P/N…
- 26 Jul 2000
Plate, cracked
DURING OP 15 MAINT CHECK ON LT FWD PAX DOOR, THE FWD BOTTOM LIGHTENING HOLE, DOOR HINGE SHAFT PLATE HAD A CRACK. REMOVED AND REPLACED BEAM (P/N 99557-503) BY…
- 26 Jul 2000
Rib, cracked
DURING OP 15 MAINT CHECK ON THE VERTICAL STABILIZER LOWER LEADING EDGE SECTION HAD 3 CRACKED RIBS ON INTERIOR. INSTALLED REPAIR ANGLE DOUBLERS PER SSRM…
- 26 Jul 2000
Longeron, cracked
DURING OP 15 MAINT CHECK, LONGERON 29R FORMER FOOT WAS CRACKED ON THE FWD END, AFT OF STA 579. INSTALLED NEW 29R LONGERON PER SRM 51-30-2 PAGE 1, AND 51-30-5…
- 24 Jul 2000
Angle, cracked
DURING OP 15 MAINT CHECK, FOUND TRANSITION ANGLE FROM FUSELAGE TO VERTICAL STABILIZER, APPROXIMATELY STA 1096, WITH A CRACK AT A SCREW HOLE TO EDGE OF ANGLE,…
- 17 Jul 2000
Seat Track, corroded
DURING OP 16 MAINT CHECK, FOUND CORROSION ON SEAT TRACK AT RBL 22 FROM APPROX STA 200 TO 229, BETWEEN FLOOR PANELS 14 AND 13. REMOVED CORRODED TRACK TO…
- 10 Jul 2000
Keelbeam, damaged
DURING OP 15 MAINT CHECK, FOUND ON THE LOWER FUSELAGE, THE RT CANTED KEEL BEAM AREA, NECESSARY TO ANALYZE THE CANTED KEEL BEAM WEB SPLICE REPAIR PER SSRM…
- 10 Jul 2000
Keelbeam, damaged
DURING OP 15 MAINT CHECK, ON THE LOWER FUSELAGE, LT CANTED KEEL BEAM AREA WAS NECESSARY TO ACCOMPLISH KEEL BEAM WEB SPLICE REPAIR PER SSRM 53-10-110. MODIFIED…
- 9 Feb 2000
Wire, worn
THE EGRESS LIGHTING WAS INOPERATIVE FROM ROW 9 TO THE AFT CABIN. REPLACED FEEDER CABLE (P/N 5854-1) AND FLEX CABLE (P/N 5853-1). CHECK-C 1-14-00 STL.
- 7 Feb 2000
Power Supply, failed
F/C EGRESS LIGHTS ON WITH SWITCH IN ARMED POSITION. REPLACED POWER SUPPLY. CHECK-C 01-14-00 STL.
- 7 Feb 2000
Tail Cone, ejected
ON THE GROUND, THE TAIL CONE WAS INADVERTANTLY DEPLOYED. REINSTALLED TAIL CONE ASSEMBLY PER MC8-5303. OP16 08-24-97 MCI..
- 5 Jul 1999
Valve, failed
DURING FINAL APPROACH, THE RIGHT ENGINE FLAMED OUT. FOUND FUEL LEAKING AT THE PRESSURIZATION AND DUMP VALVE FITTING. REPLACED THE DUMP VALVE, THE SEAL AND THE…
- 26 Jun 1999
Wire, worn
THE FORWARD SECTION OF THE COACH CABIN FLOOR EGRESS LIGHTS WAS INOPERATIVE. FOUND A HOLE IN THE FEEDER CABLE. REPLACED THE FEEDER CABLE FROM THE POWER SUPPLY…
- 28 May 1999
Longeron, cracked
LONGERON 5L FS 639 WAS CRACKED .25 INCH. REPLACED SECTION ON LONG 5L AND INSTALLED SPLICE SECTION PER SRM 53-02, FIG 18 AND SRO9530128 DRAWING. CHECK-C…
- 28 May 1999
Longeron, cracked
LONGERON 6R AT FS 756 WAS CRACKED .25 INCH. REPAIRED LONGERON 6R AT FS 756 PER SRM 53-02 FIG 18 SHEET 1. CHECK-C 11-13-98 STL.
- 28 May 1999
Longeron, cracked
FOUND LONGERON 4R AT FS 756 CRACKED .25 INCH. CUT OUT DAMAGED SECTION AND REPAIRED LONGERON PER SRM 53-02 FIG 18 SHEET 1. CHECK-C 11-13-98 STL.
- 28 May 1999
Longeron, cracked
FOUND LONGERON 5L AT FS 699 CRACKED .25 INCH. FABRICATED AND INSTALLED LONGERON AND SPLICES IN LONGERON 5L AT FS 699 PER SRM 53-02 FIG 18 SHEET 1. CHECK-C…
- 27 May 1999
Longeron, cracked
LONGERON 6L AT FS 658 WAS CRACKED .25 INCH LONG. REPAIRED PER SRM 53-02, FIG 18 AND STANDARD PRACTICES. CHECK-C 11-13-98 STL.
- 27 May 1999
Longeron, cracked
FOUND .25 INCH CRACKS AT LONGERON 6L AT FS 737 AND 756, AND LONGERON 7R AT FS 680. REPAIRED EACH PER SRM 53-02 FIG 18, AND SRO 9530128. CHECK-C 11-13-98 STL.
- 11 Nov 1998
Pan, cracked
DURING CHECK-C MAINT, FOUND LT FWD EMERGENCY EXIT DOOR WITH A ONE INCH CRACK IN AFT UPPER CORNER, AND 1 INCH CRACK IN LOWER AFT CORNER. REMOVED AND REPLACED…
- 11 Nov 1998
Pan, cracked
DURING CHECK-C MAINT, FOUND RT FWD EMERGENCY EXIT DOOR WITH TWO 1 INCH PAN CRACKS IN DOOR CORNERS. REPLACED DOOR PAN PER SRM 51-30 STANDARD PRACTICES ON SHOP…
- 11 Nov 1998
Pan, cracked
DURING CHECK-C MAINT, THE LT AFT EMERGENCY EXIT DOOR HAD TWO 1 INCH CRACKS IN DOOR PAN IN BOTH CORNERS. REPAIRED PAN PER DC9 SRM 51-00 STANDARD PROCEDURES.
- 7 Nov 1998
Beam, cracked
DURING CHECK-C MAINT, FOUND ON THE RT FWD SERVICE DOOR THE NR 5 BEAM HAD A CRACK AT THE AFT END OF THE BEAM CLIP AT I/B RIVET HOLE. REPLACED CLIP FASTENER PER…
- 15 Dec 1997
Shield, worn
IND - FLT 374 - DURING CLIMB, CAPTAIN EXPERIENCED ELECTRIC SHOCK WHEN TAXI LIGHT SWITCH MFG P/N 8906K1269 AND GROUND FLOOD LIGHT SWITCH MFG P/N MS24523-23…
- 4 Aug 1997
Frame, cracked
DURING OP16 MAINTENANCE CHECK, FOUND FUSELAGE MAIN FRAME CRACKED AT FS 756L AT FWD END OF AFT CARGO BIN. INSTALLED NEW MAIN FRAME PER ARA 11821. (M)
- 4 Aug 1997
Rib, cracked
MCI - DURING OP 16 MAINTENANCE CHECK, FOUND ON RT WING XRS 414.1 RIB, THE INBD AFT LOWER FOOT FORWARD END CRACKED APROXIMATELY 3 INCHES. REPLACED FITTING PER…
- 4 Aug 1997
Bulkhead Angle, cracked
MCI - DURING OP 16 MAINTENANCE CHECK, FOUND FORWARD CARGO PRESSURE BULKHEAD ANGLE AFT OF STR 24L AT FS 608, HAD CRACK IN RADIUS. REPLACED WITH NEW PART PER…
- 9 Apr 1997
Actuator, worn
STL - FLT 627 - DURING CLIMB FOLLOWING GEAR RETRACTION, LEFT MAIN GEAR UNSAFE LIGHT AND GEAR DOOR LIGHT REMAINED ON. REMOVED AND REPLACED LEFT MAIN RETRACT…
- 18 Dec 1996
Wire, broken
STL - AFTER TAKEOFF WHEN LANDING GEAR WAS RETRACTED, RIGHT MAIN LANDING GEAR DID NOT INDICATE UP AND LOCKED. CYCLED LANDING GEAR. FOUND WIRE 2G204E24 AND…
- 16 Apr 1996
Longeron, cracked
STL - DURING SPECIAL CHECK, FOUND CABIN AREA LONGERON 6L CRACKED AT BOTH ATTACH POINTS, STATION 718. REPAIRED PER SRM 53-02, FIGURE 2. (M)
- 13 Jul 1995
Oleo Seals, sticking
STL - FLT 246 - AFTER TAKEOFF, LANDING GEAR HANDLE WAS LOCKED IN THE DOWN POSITION. FOUND NOSE LANDING GEAR OLEO STICKING IN THE COMPRESSED POSITION. REPLACED…