N973NA
Bell 206B FAA →
registration
earlier registrations
1 past record
service difficulty reports
19 reports
- 3 Jun 1999
Floorbeam, corroded
FOUND CORROSION ON FLOORBEAM FRAME 41 CENTER AREA BY FITTING. CAUSE OF CORROSION DETERMINED TO BE ENVIRONMENTAL CORROSION BLENDED AND FOUND BEYOND LIMITS IAW…
- 3 Jun 1999
Frame, corroded
FOUND FRAME 27A RT CORRODED INBOARD AND OUTBOARD OF LOWER INTERCOSTAL. CAUSE OF CORROSION DETERMINED TO BE ENVIRONMENTAL CORROSION BLENDED AND FOUND BEYOND…
- 3 Jun 1999
Frame, corroded
FOUND FORWARD CARGO DOOR INNER STRUCTURE HAS CORROSION AFT OF PRESSURE DOOR. CAUSE OF CORROSION DETERMINED TO BE ENVIRONMENTAL. CORROSION REMOVED AND FOUND…
- 3 Jun 1999
Intercostal, corroded
FOUND INTERCOSTAL BETWEEN FRAMES 27A RT AND 28A RT BELOW STRINGER 19 CORRODED. CAUSE OF CORROSION DETERMINED TO BE ENVIRONMENTAL. CORROSION REMOVED AND FOUND…
- 3 Jun 1999
Frame, corroded
FOUND UPPER CHORD ON FRAME 27A RT CORRODED INBOARD OF LOWER INTERCOSTAL. CAUSE OF CORROSION DETERMINED TO BE ENVIRONMENTAL. CORROSION REMOVED AND FOUND BEYOND…
- 3 Jun 1999
Intercostal, corroded
INTERCOSTAL BETWEEN FRAMES 27A LT AND 28A LT BELOW STRINGER 19 CORRODED. CAUSE OF CORROSION DETERMINED TO BE ENVIRONMENTAL. CORROSION REMOVED AND FOUND BEYOND…
- 3 Jun 1999
Intercostal, corroded
FOUND INTERCOSTAL BETWEEN FRAMES 27A RT AND 28 RT BELOW STRINGER 16R CORRODED. CAUSE OF CORROSION DETERMINED TO BE ENVIRONMENTAL. CORROSION BLENDED AND FOUND…
- 3 Jun 1999
Frame, corroded
FOUND FRAMES 28A RT CORRODED INBOARD AND OUTBOARD OF LOWER INTERCOSTAL. CAUSE OF CORROSION DETERMINED TO BE ENVIRONMENTAL. CORROSION BLENDED AND FOUND BEYOND…
- 3 Jun 1999
Stringer, corroded
SPECIAL STRINGER ON LOWER KEEL BEAM, LEFT SIDE HAS CORROSION BETWEEN FRAMES 24A LT AND 27A LT. CAUSE OF CORROSION DETERMINED TO BE ENVIRONMENTAL. CORROSION…
- 3 Jun 1999
Stringer, corroded
SPECIAL STRINGER ON LOWER KEEL BEAM, RIGHT SIDE HAS CORROSION BETWEEN FRAMES 24A RT AND 27A RT. CAUSE OF CORROSION DETERMINED TO BE ENVIRONMENTAL. CORROSION…
- 3 Jun 1999
Fitting, corroded
FUSELAGE ATTACH FITTING FOR SPLICE CONNECTING FRAMES 27A RT AND LT CORRODED. CAUSE OF CORROSION DETERMINED TO BE ENVIRONMENTAL. CORROSION BLENDED AND FOUND…
- 3 Jun 1999
Bulkhead Web, corroded
FORWARD BULKHEAD BONDING STRIP AT 11:00 O'CLOCK POSITION HAS CORROSION PITTING. CAUSE OF CORROSION DETERMINED TO BE ENVIRONMENTAL. CORROSION BLENDED AND FOUND…
- 3 Jun 1999
Frame, corroded
FRAME 27A LT CORRODED INBOARD OF LOWER INTERCOSTAL. CAUSE OF CORROSION DETERMINED TO BE ENVIRONMENTAL. CORROSION BLENDED AND FOUND BEYOND LIMITS IAW SRM…
- 23 Feb 1998
Spar, corroded
DURING ACCOMPLISHEMENT OF SB ATR 42-57-0044R2 AD 97-26-11, FOUND CORROSION DAMAGE ON THE LEFT WING REAR SPAR LOWER EXTRUSION FOUND OUT OF LIMITS. THE…
- 14 May 1997
Support, corroded
DURING A CPCP 4 CHECK PERFORMED AT AMR REGIONAL AIRCRAFT MAINTENANCE CENTER, CORROSION WAS FOUND ON THE SUPPORT BEAM THAT RUNS IN THE MIDDLE OF FRAME 39 AND…
- 14 May 1997
Support, corroded
DURING A CPCP 4 CHECK PERFORMED AT AMR REGIONAL AIRCRAFT MAINTENANCE CENTER, CORROSION WAS FOUND ON THE SUPPORT BEAM THAT RUNS IN THE MIDDLE OF FRAME 39 AND…
- 14 May 1997
Seat Track, corroded
DURING A CPCP-4 CHECK PERFORMED AT AMR REGIONAL AIRCRAFT MAINTENANCE CENTER, SEAT TRACK FROM FRAMS 39 TO 41 HAVE CORRROSION IN LAVATORY. REMOVED AND REPLACED…
- 14 Jul 1996
Transfer Tube, loose
DURING CLIMB, CREW RECEIVED FIRE INDICATION ON THE LEFT ENGINE AND FIRE BOTTLE WAS DISCHARGED. FOUND NR 14 SECONDARY FUEL NOZZLE TRANSFER TUBE LOOSE WITH FUEL…
- 27 Jan 1995
Fitting, cracked
DURING PHASE NR 4 INSPECTION, FOUND NR 2 ENGINE LEFT AFT LATERAL ENGINE MOUNT ATTACHMENT FITTING CRACKED WITH NO VIBRATION OR DISCREPANCY REPORTED DURING…