N971Z
1966 Douglas DC9-15 standard FAA →
earlier registrations
1 past record
- 1966
service difficulty reports
9 reports
- 24 Mar 1999
Panel, worn
WHILE PARKED AT THE GATE USING GROUND POWER, SMOKE WAS SEEN COMING INTO THE CABIN FROM THE LOWER ELECTRONIC COMPARTMENT. SHUT DOWN ELECTRICAL POWER. FOUND THE…
- 3 Sep 1998
Connector, dirty
THE OVERWING EXIT SECTION OF THE EGRESS LIGHTS WERE COMING ON INTERMITTENTLY IN FLIGHT. FOUND CONNECTOR FOR THAT SECTION WAS DIRTY. CLEANED ELECTOR CONNECTOR.…
- 24 Aug 1998
Control Valve, failed
WHEN LANDING THE RT BRAKE WAS INOPERATIVE WHEN THE RT HYD SYSTEM WAS SELECTED. BRAKING NORMAL WHEN LT HYD SYS SELECTED. REPLACED THE RT BRAKE CONTROL VALVE…
- 6 Mar 1997
Fuel Control, malfunctioned
BNA - DURING TAKEOFF ROLL, NR 1 ENGINE, S/N 3817, SPOOLED DOWN DUE TO A FAILED FUEL PUMP. REMOVED AND REPLACED FUEL PUMP, MFG P/N 378200, AND JET FUEL…
- 25 Feb 1997
Power Supply, failed
STL - FLT 581 - DURING LAYOVER MAINTENANCE, FIRST CLASS EMERGENCY EGRESS LIGHTING POWER SUPPLY FAILED. REMOVED AND REPLACED EGRESS POWER SUPPLY, MFG P/N…
- 22 Jan 1997
Longeron, cracked
STL - DURING OP-15, FOUND TWO INCH CRACK IN LONGERON 15R, STATION 780. REPAIRED PER SRM 53-02, PAGE 2A. (M)
- 27 Oct 1996
Power Supply, inoperative
STL - EMERGENCY EGRESS LIGHTS AT ROWS 2.5 INOPERATIVE. REMOVED AND REPLACED POWER SUPPLY, MFG P/N 5822-2. OPERATION CHECK NORMAL. (M)
- 25 Mar 1996
Oil Clog Light, illuminated
DURING CLIMB NR 1 ENGINE, S/N 3810, WAS SHUT DOWN DUE TO OIL STRAINER CLOG LIGHT ILLUMINATION. ENGINE TOTAL TIME 39,869, TOTAL CYCLES 46,939.
- 11 Sep 1995
Seat Track, corroded
STL - DURING OP-9, FOUND CORROSION IN NR 2 GALLEY RIGHT CABIN OUTBOARD SEAT TRACK MOUNT AREA, STATION 237. INSTALLED NEW SEAT TRACK PER SRM 53-05, FIGURE 4. (M)