N969JT
2016 Airbus A321-231 standard FAA →
registration
- 2016
service difficulty reports
20 reports
- 26 Oct 2025
Unknown, odor
FLT#8357, PHX-LAX. "ON DEPARTURE FROM FLL AFTER A HEAVY RAIN SHOWER WE EXPERIENCED AN ODOR IN THE A/C THAT WAS SENSED BY BOTH PILOTS AND FWD FAS DISSAPATED…
- 20 Oct 2025
Fcu, leaking
FLT#734, SFO-BOS. "OIL FUME EVENT RECOGNIZED BY PILOTS, INTERMITTENT THROUGHOUT DESCENT FROM 10,000 FT TO THE GROUND. UNABLE TO ISOLATE/IDENTIFY SOURCE. F/A'S…
- 13 Oct 2025
Fcu, leaking
FLT 189, JFK-SAN. DESCENDING THROUGH 9000 FT ON ARRIVAL, FLIGHT ATTENDANT IN AFT GALLEY REPORTED FUMES (DIRTY SOCK SMELL). NO SMELL REPORTED IN FORWARD…
- 13 Oct 2025
Filter, odor
FLT#190, SAN-JFK. "INFLIGHT ADVISED REACHING TO GATE OF AN ODOR EVENT DESCENDING THROUGH 20,000 FT PLATIC BURNING DIRTY SOCK SMELL IN AFT JUMPSEAT. ALSO…
- 21 Jul 2025
A/C Pack, odor
FLT#1178, LAS-BOS. ODOR EVENT BELOW 4000' CLOSED X-BLEED AND TURNED PACK 1OFF ODOR DISSIPATED. AT GATE W/APU BLEED ON OPENED X-BLEED & TURNED PACK 1 BACK TO…
- 14 Mar 2025
Oil System, leaking
FLT#823, JFK-LAX. (AIRCRAFT DIVERTED TO ORD) 'ENG 2 OIL QUANTITY WAS OVER 11 QTS LEAVING JFK WGEN WE LANDED IN SFO OIL WAS AT 3.5 QTS; REF GMM 6.45 SVC ENG 2…
- 12 Nov 2024
Hinge, cracked
DURING HEAVY MAINTENANCE: REF AEROMAN WO: 2024 311/1 NR# 2024-670889. CRACK ON ELEVATOR HINGE #2 FLANGE ON LH HORIZONTAL STABILIZER; (RESOLVED ON W/O: 1332286…
- 29 Aug 2024
Apu, contaminated
FLT#1833, BOS-SFO. 'DIRTY SOCK SMELL IN COCKPIT & FWD CABIN CLIMBING OUT OF BOSTON (ALSO SLIGHT SMELL CHALF) UNTIL ABOUT 15K THEN STARTED DISSIPATING. BETTER…
- 28 Jun 2024
Smoke Detector, false activation
FLT#81, JFK-RNO. (AIRCRAFT DECLARED AN EMERGENCY AND DIVERTED TO DEN). ' AFT AVIONICS SMOKE IND IN CRUISE QRH COMPLETED ( AVIONIC SMOKE DETECTION SYSTEM AFT…
- 15 Dec 2022
None, none
FLT#277, FLL-SFO. 'AS PER MCC, VERBAL REPORT RECEIVED FROM FLT CREW FOR SEVERE TURBULENCE; PERFORMED INSPECTION AFTER FLIGHT IN EXCESSIVE TURBULENCE IAW AMM…
- 13 May 2022
None, none
FLT#915, JFK-SFO. 'PASSING THROUGH 9,000 FEET IN THE DESCENT WE COULD SMELL A MUSTY DIRTY SOCKS SMELL. VERY NOTICEABLE IN THE FLIGHT DECK. TURNING PACK 1 OFF…
- 3 Apr 2022
Skin, dented
DURING HEAVY MAINTENANCE, DENT EXTERNAL SKIN LOCATED FRAME 35.1 PLUS 5 INCH BTW STR 36R AND STR 37R AT LOWER FUSELAGE; REF AE NR 2022-156488 WO 2022…
- 3 Apr 2022
Skin, dented
DURING HEAVY MAINTENANCE, DENT EXTERNAL SKIN LOCATED FRAME 35 PLUS 6 INCH BTW STR 30L AND STR 31L AT LOWER FUSELAGE ; (RESOLVED ON W/O: 1156227 TASKCARD:…
- 21 Apr 2021
Unknown, unknown
FLT 620, SAN-BOS. DUE TO A FAULT TURNOVER ABOUT DOOR ASSIST NOTOPENING L-1 DOOR, DOR ASSIST TEST NEEDED ; PERFORMED OPERATIONAL TEST OF DEPLOYMENT ON L-1 DOOR…
- 20 Apr 2021
Slide, inoperative
FLT 620, SAN-BOS. SLIDE PIN WOULD NOT ENGAGE ; REMOVED AND REPLACED L1 SLIDE DOOR IAW AMM 25-62-44. OPS CHK GOOD, NO FURTHER DEFECTS NOTED AT THIS TIME.
- 20 Apr 2021
Diaphragm, punctured
FLT 620, L1 DOOR ASSIST DIAPHRAGM PUNCTURED ; REPLACED DIAPHRAGM AS REQUIRED PER AMM 52-10-00 NO FURTHER DEFECTS NOTED
- 26 Jan 2020
Battery, no test
11WL FAILED EPSU BATTERY FAILED A CAPACITY TEST. R & R THE 11WL BATTERY IAW AMM 33-51-00 EPSU TEST GOOD.
- 26 Jan 2020
Battery, no test
15WL BATTERY FAILED A CAPACITY TEST. R & R THE 15WL BATTERY IAW AMM 33-51-38 EPSU TESTED GOOD.
- 4 Mar 2017
Unknown, odor
DURING CRUISE, ROWS 27-29 HAD A STRONG ELECTRICAL BURNING ODOR NOTED. ALL DEVICES WERE UNPLUGGED. ODOR DISAPPEARED. NO GALLEY & LAV ABNORMALLITIES NOTED. ALL…
- 20 Nov 2016
Amu, loose
AFTER TAKEOFF, PILOT REPORTED THE CAPTAIN`S AND FIRST OFFICER AND BACK UP AUDIO CONTROL PANELS FAILED. NO COMMS AVAILABLE. CREW WAS ABLE TO COMMUNICATE VIA…