search

N969AS

McDonnell Douglas MD-90-30 FAA →

earlier registrations

1 past record
  1. Aersale INC

    McDonnell Douglas MD-90-30

    deregistered 31 Jul 2021

    s/n 53496

service difficulty reports

210 reports
  1. 10 Jul 2007

    Longeron, dented

    Doug DC983

    FUSELAGE DENTED. REPAIR FUSELAGE SKIN AND LONGERON PER SRM 53-02.

  2. 29 Mar 2007

    Skin, dented

    Doug DC983

    FUSELAGE SKIN DENTED. REMOVED DAMAGED AREA. INSTALLED SKIN FILLER INTERNAL FINGER DOUBLERS INTERNAL REPAIR DOUBLERS AND INTERNAL REPAIR STRAPS PER SRM 53-04.

  3. 29 Mar 2007

    Skin, dented

    Doug DC983

    FUSELAGE DENTED. REMOVED DAMAGED AREA. INSTALLED SKIN FILLER INTERNAL REPAIR DOUBLERS REPAIR STRAPS AND FINGER DOUBLERS PER SRM 53-04.

  4. 29 Mar 2007

    Seat Track, corroded

    Doug DC983

    CABIN SEAT TRACK CORRODED. REMOVED DAMAGED SECTION OF TRACK. INSTALLED REPAIR TRACK AND SPLICE PER SRM 53-05.

  5. 29 Mar 2007

    Doubler, chafed

    Doug DC983

    LEFT WING OUTBOARD FLAP CENTER VANE IS CHAFED ON EXISTING REPAIR DOUBLER. REPLACED DOUBLER PER SRM 51-70-2.

  6. 29 Mar 2007

    Doubler, gouged

    Doug DC983

    RIGHTHAND OUTBOARD FLAP VANE LEADING EDGE IS GOUGED AT PREVIOUS REPAIR. REPLACED EXISTING REPAIR DOUBLER PER SRM 51-70-2.

  7. 29 Mar 2007

    Vane, gouged

    Doug DC983

    RIGHTHAND OUTBOARD FLAP OUTBOARD VANE IS GOUGED. INSTALLED REPAIR DOUBLER PER SRM 51-70-2.

  8. 29 Mar 2007

    Vane, gouged

    Doug DC983

    LEFTHAND OUTBOARD FLAP OUTBOARD VANE IS GOUGED. INSTALLED REPAIR DOUBLER PER SRM 51-70-2.

  9. 28 Mar 2007

    Intercostal, cracked

    Doug DC983

    AFT ACCESSORY INTERCOSTAL CRACKED. REPLACED INTERCOSTAL PER SRM 51-10-4 AND 51-30-2.

  10. 28 Mar 2007

    Floor Panel, corroded

    Doug DC983

    CABIN FLOOR PANEL CORRODED. REPLACED PANEL PER SRM 51-10-3 AND DAC DWG 9932816.

  11. 28 Mar 2007

    Floor Panel, corroded

    Doug DC983

    CABIN FLOOR PANEL CORRODED. REPLACED PANEL PER SRM 53-05 AND DAC DWG S4932106.

  12. 28 Mar 2007

    Floor Panel, punctured

    Doug DC983

    CABIN FLOOR PANEL PUNCTURED. REPLACED PANEL PER SRM 53-05 AND DAC DWG S4932106.

  13. 28 Mar 2007

    Floor Panel, punctured

    Doug DC983

    CABIN FLOOR PANEL PUNCTURED. REPLACED PANEL PER SRM 53-05 AND DAC DWG S4932106.

  14. 28 Mar 2007

    Floor Panel, cracked

    Doug DC983

    CABIN FLOOR PANEL WEB IS CRACKED. REMOVED DAMAGED SECTION. INSTALLED REPAIR FILLER AND DOUBLER PER SRM 51-70.

  15. 28 Mar 2007

    Floor Panel, cracked

    Doug DC983

    CABIN FLOOR WEB IS CRACKED. REMOVED DAMAGED SECTION. INSTALLED REPAIR FILLER AND DOUBLER PER SRM 51-70-4.

  16. 28 Mar 2007

    Floor Panel, punctured

    Doug DC983

    CABIN FLOOR PANEL PUNCTURED. REPLACED PANEL PER SRM 53-05 AND DAC DWG S4932106.

  17. 28 Mar 2007

    Floor Panel, punctured

    Doug DC983

    CABIN FLOOR PANEL PUNCTURED. REMOVED DAMAGED SECTION. APPLIED FILLER PLIES.

  18. 13 Mar 2007

    Slide, malfunctioned

    Doug DC983

    AFT ACCY COMPARTMENT EMERGENCY ESCAPE SLIDE FAILED TO DEPLOY DURING DEPLOYMENT TEST. INDICATION WAS THAT THE TAIL CONE STRAP (LANYARD) DETACHED FROM THE SLIDE…

  19. 15 Jan 2006

    Longeron, corroded

    Doug DC983

    C-CHECK, LONGERON CORRODED. REPLACED DAMAGED SECTION WITH SPLICES. (K)

  20. 15 Jan 2006

    Floor Panel, punctured

    Doug DC983

    C-CHECK, CABIN FLOOR PANEL PUNCTURED. REPLACED FLOOR PANEL. (K)

  21. 15 Jan 2006

    Floor Panel, gouged

    Doug DC983

    C-CHECK, CABIN FLOOR PANEL GOUGED. REPLACED FLOOR PANEL. (K)

  22. 15 Jan 2006

    Floor Panel, delaminated

    Doug DC983

    C-CHECK, CABIN FLOOR PANEL DELAMINATED. REPLACED FLOOR PANEL. (K)

  23. 15 Jan 2006

    Floor Panel, delaminated

    Doug DC983

    C-CHECK, CABIN FLOOR PANEL DELAMINATED AT FASTENER LOCATIONS. REPLACED FLOOR PANEL. (K)

  24. 15 Jan 2006

    Floor Panel, delaminated

    Doug DC983

    C-CHECK, CABIN FLOOR PANEL DELAMINATED. REMOVED DAMAGED AREA. APPLIED GLASS CLOTH REPAIR. (K)

  25. 15 Jan 2006

    Floor Panel, delaminated

    Doug DC983

    C-CHECK, CABIN FLOOR PANEL DELAMINATED. REMOVED DAMAGED AREA. APPLIED GLASS CLOTH REPAIR. (K)

  26. 15 Jan 2006

    Floor Panel, delaminated

    Doug DC983

    C-CHECK, CABIN FLOOR PANEL DELAMINATED. REMOVED DAMAGE AREA. APPLIED GLASS CLOTH REPAIR. (K)

  27. 15 Jan 2006

    Floor Panel, delaminated

    Doug DC983

    C-CHECK, CABIN FLOOR PANEL DELAMINATED. REMOVED DAMAGED AREA. APPLIED GLASS CLOTH REPAIR. (K)

  28. 15 Jan 2006

    Floor Panel, delaminated

    Doug DC983

    C-CHECK, CABIN FLOOR PANEL DELAMINATED. REMOVED DAMAGED AREA. APPLIED GLASS CLOTH REPAIR. (K)

  29. 15 Jan 2006

    Floor Panel, delaminated

    Doug DC983

    C-CHECK, CABIN FLOOR PANEL DELAMINATED. REMOVED DAMAGED AREA. APPLIED GLASS CLOTH REPAIR. (K)

  30. 15 Jan 2006

    Floor Panel, delaminated

    Doug DC983

    C-CHECK, CABIN FLOOR PANEL DELAMINATED. REMOVED DAMAGED AREA. APPLIED GLASS CLOTH REPAIR. (K)

  31. 15 Jan 2006

    Floor Panel, delaminated

    Doug DC983

    C-CHECK, CABIN FLOOR PANEL DELAMINATED. REMOVED DAMAGED AREA. APPLIED GLASS CLOTH REPAIR. (K)

  32. 15 Jan 2006

    Floor Panel, delaminated

    Doug DC983

    C-CHECK, CABIN FLOOR PANEL DELAMINATED. REMOVED DAMAGED AREA. APPLIED GLASS CLOTH REPAIR. (K)

  33. 15 Jan 2006

    Cusp Web, corroded

    Doug DC983

    C-CHECK, CABIN FLOOR CUSP WEB CORRODED. REMOVED DAMAGED SECTION. INSTALLED REPAIR DOUBLER AND FILLER. (K)

  34. 15 Jan 2006

    Skin, dented

    Doug DC983

    C-CHECK, FUSELAGE DENTED. REMOVED DAMAGED SECTION. INSTALLED INTERNAL DOUBLERS, FINGER DOUBLERS, AND INTERNAL STRAP. (K)

  35. 15 Jan 2006

    Skin, dented

    Doug DC983

    C-CHECK, FUSELAGE DENTED. REMOVED DAMAGED SECTION. INSTALLED INTERNAL DOUBLERS AND INTERNAL STRAPS. (K)

  36. 15 Jan 2006

    Skin, gouged

    Doug DC983

    C-CHECK, LT WING OB FLAP IB VANE IS GOUGED OF LEADING EDGE. REMOVED DAMAGED SECTION. INSTALLED REPAIR DOUBLER AND FILLER. (K)

  37. 15 Jan 2006

    Skin, debonded

    Doug DC983

    C-CHECK, LT WING OB FLAP CENTER PREVIOUS SKIN REPAIR IS DEBONDED. REMOVED DAMAGED SECTION. INSTALLED REPAIR DOUBLER AND FILLER. (K)

  38. 15 Jan 2006

    Skin, nicked

    Doug DC983

    C-CHECK, RT WING OB FORE FLAP CENTER DENTED ON LE PREVIOUS REPAIR. REMOVED DAMAGED SECTION. INSTALLED REPAIR DOUBLER AND FILLER. (K)

  39. 15 Jan 2006

    Skin, dented

    Doug DC983

    C-CHECK, FUSELAGE SKIN DENTED. COLD-WORKED AREA BACK TO ORIGINAL CONTOUR AND INSTALLED REPAIR DOUBLER. (K)

  40. 15 Jan 2006

    Torque Tube, corroded

    Doug DC983

    C-CHECK, RUDDER TAB TORQUE TUBE LOWER SPLINES CORRODED. REPLACED RUDDER TAB TORQUE TUBE SHAFT ASSEMBLY. (K)

  41. 15 Jan 2006

    Crank Assy, corroded

    Doug DC983

    C-CHECK, RUDDER TAB TORQUE TUBE CONTROL CRANK SPLINES CORRODED. REPLACED TORQUE TUB CONTROL CRANK ASSY. (K)

  42. 15 Jan 2006

    Spline, corroded

    Doug DC983

    C-CHECK, RUDDER TAB TORQUE TUBE SPLINE CORRODED. REPLACED RUDDER TAB TORQUE TUBE. (K)

  43. 15 Jan 2006

    Spring, corroded

    Doug DC983

    C-CHECK, RUDDER LOAD FEEL AND TRIM SPRING ASSEMBLY CORRODED. REPLACED RUDDER LOAD FEEL AND TRIM SPRING ASSEMBLY. (K)

  44. 15 Jan 2005

    Longeron, corroded

    Doug DC983

    C-CHECK, LONGERON CORRODED. REPLACED LONGERON. (K)

  45. 30 Oct 2004

    Wire Harness, misrouted

    Doug DC983

    SEA BTB NON-ROUTINE LINE CHECK-SPARKS AND SMOKE NOTED COMING FROM OVERHEAD GRILL BETWEEN L1 DOOR AND FORWARD GALLEY. INSP REVEALED THAT A WIRE BUNDLE WAS…

  46. 30 Oct 2004

    Skin, dented

    Doug DC983

    C-CHECK- RT IB FLAP LOWER SURFACE IS DENTED 11.5 INCHES FROM T/E AND 19.25 INCHES FROM IB FAIRING SEAL. REMOVED DAMAGED SECTION. INSTALLED REPAIR DOUBLER IAW…

  47. 30 Oct 2004

    Skin, dented

    Doug DC983

    C-CHECK- RT IB FLAP LOWER SURFACE IS DENTED 24 INCHES FROM THE T/E AND 17.5 INCHES FROM IB FAIRING SEAL. REMOVED DAMAGED SECTION. INSTALLED REPAIR DOUBLER IAW…

  48. 30 Oct 2004

    Skin, delaminated

    Doug DC983

    C-CHECK- RT IB FLAP VANE HAS DELAMINATION ON LOWER SURFACE. REMOVED DAMAGED SECTION, AND INSTALLED REPAIR FILLER AND DOUBLER IAW SRM.

  49. 30 Oct 2004

    Skin, chafed

    Doug DC983

    C-CHECK- LT WING L/E SURFACE HAS 7 CHAFED AREAS 5 INCHES FROM L/E AND I/B OF NR 5 L/E SLAT TRACK. REMOVED DAMAGED AREAS, THEN HFEC TREATED, PRIMED AND…

  50. 30 Oct 2004

    Diverter, cracked

    Doug DC983

    C-CHECK- RT ACM(AIR CYCLE MOTOR) DIVERTER IS CHAFED AND CRACKED. REMOVED DAMAGE, WELDED IN FILLER REPAIR IAW EA.

  51. 30 Oct 2004

    Retainer, cracked

    Doug DC983

    C-CHECK-HEAT EXCHANGER RAM AIR (Y) DUCT HAS BROKEN RETAINER ON LT SIDE. REMOVED DAMAGE, WELDED IN REPAIR TAB IAW EA.

  52. 30 Oct 2004

    Floor Panel, delaminated

    Doug DC983

    C-CHECK-MAIN CABIN FLOOR PANEL IS DELAMINATED AT CORNER. REPLACED FLOOR PANEL IAW SRM.(K)

  53. 30 Oct 2004

    Frame, chafed

    Doug DC983

    C-CHECK - AFT ACCESSORY COMPARTMENT FRAME CHAFED AT LONGERON 20R. REMOVED DAMAGED SECTION AND INSTALLED REPAIR ANGLE IAW SRM.(K)

  54. 28 Oct 2004

    Battery Pack, discharged

    Doug DC983

    OKC C-CHECK, OVERWING EMERGENCY EVACUATION LIGHTS INOPERATIVE. REPLACED ASSOCIATED POWER SUPPLY (BATTERY PACK). LIGHTS THEN OPERATED PROPERLY.(K)

  55. 1 Aug 2004

    Handle, malfunctioned

    Doug DC983

    LAS - POST FLIGHT INSPECTION, FOUND AFT SERVICE L2 DOOR COULD NOT BE OPENED FROM INSIDE. REPLACED DOOR HANDLE AND RETAINING PIN, BOLT P/N 2705574. DOOR THEN…

  56. 13 May 2004

    Linkage, out of adjust

    Doug DC983

    ANC - DURING PREFLIGHT CHECK, FOUND LEFT CAPTAINS SLIDING CLEARVIEW WINDOW WOULD NOT OPEN. ADJUSTED SLIDING MECHANISM IN TRACK. WINDOW THEN OPERATED PROPERLY.…

  57. 7 May 2004

    Linkage, disconnected

    Doug DC983

    ANC - DURING PREFLIGHT CHECK, FOUND LEFT CAPTAINS SLIDING CLEARVIEW WINDOW WOULD NOT OPEN. RECONNECTED LINKAGE. WINDOW THEN OPERATED PROPERLY. (M)

  58. 4 Nov 2003

    Rod, out of position

    Doug DC983

    LAX PREFLIGHT CHECK, LEFT CAPTAINS SLIDING CLEARVIEW WINDOW WOULD NOT OPEN. REPOSITIONED ACTUATING ROD GUIDE PIN. WINDOW THEN OPERATED PROPERLY. (M)

  59. 15 Oct 2003

    Vane, punctured

    Doug DC983

    OKC DURING 15K CHECK, FOUND RIGHT WING INBOARD FLAP VANE, FOREFLAP, IS PUNCTURED. INSTALLED DOUBLER PER SRM 51-70-2 AND EA 5750-01876. (M)

  60. 15 Oct 2003

    Skin, corroded

    Doug DC983

    OKC - DURING 15K CHECK, FOUND FUSELAGE SKIN CORRODED AT STATION 769 TO 788 UNDER FAIRING RUB STRIP AND AROUND FASTENER HOLES. INSTALLED DOUBLER, FILLERS,…

  61. 15 Oct 2003

    Floorboard, cracked

    Doug DC983

    OKC - DURING 15K CHECK, FOUND PASSENGER CABIN FLOORBOARD CRACKED AT FS 889-927. REPLACED FLOORBOARD PER SRM 53-05. (M)

  62. 15 Oct 2003

    Frame, cracked

    Doug DC983

    OKC - DURING 15K CHECK, FRAME IS CRACKED IN AFT CARGO BAY AT FS 1231. REPLACED DAMAGED SECTION AND SPLICED IN NEW SECTION PER SRM 53-05. (M)

  63. 15 Oct 2003

    Skin, dented

    Doug DC983

    OKC - DURING 15K CHECK, FUSELAGE SKIN DENTED AT FS 327-350. INSTALLED CLASS 1 REPAIR PER SRM 53-04. (M)

  64. 11 Oct 2003

    Floorboard, debonded

    Doug DC983

    FOUND DURING 15K CHECK, CABIN FLOORBOARD HAS LARGE SOFT, DEBONDED, AREA FROM FS 1117 TO 1174. REPLACED FLOORBOARD PER SRM 53-05. (M)

  65. 11 Oct 2003

    Floorboard, corroded

    Doug DC983

    FOUND DURING 15K CHECK, CABIN FLOORBOARD HAS SEVERAL CORRODED INSERTS AND LARGE TORN AREA FROM FS 1155 TO 1250. REPLACED FLOORBOARD PER SRM 53-05. (M)

  66. 11 Oct 2003

    Skin, cracked

    Doug DC983

    FOUND DURING 15K CHECK, LT ENGINE UPPER COWL IS CRACKED. REPAIRED PER EA 7110-01208 AND SRM 54-06. (M)

  67. 11 Oct 2003

    Skin, corroded

    Doug DC983

    FOUND DURING 15K CEHCK, FUSELAGE SKIN CORRODED AT FS 769-788, BETWEEN LONGERON 30 AND 29R UNDER FAIRING RUB STRIP AND AROUND FASTENER HOLES. REPAIRED PER EA…

  68. 11 Oct 2003

    Beam, corroded

    Doug DC983

    FOUND DURING 15K CHECK, AFT CARGO BAY DOOR BEAM IS CORRODED IN SEVERAL PLACES. REPLACED DOOR BEAM PER SRM 51-30-5. (M)

  69. 11 Oct 2003

    Floorboard, gouged

    Doug DC983

    DURING 15K C-CHECK, FOUND CABIN FLOOR PANEL HAS SEVERAL GOUGES BETWEEN FS 1117 AND 1174. REPLACED DAMAGED FLOOR PANEL PER SRM 53-05. (M)

  70. 7 Oct 2003

    Structure, cracked

    Doug DC983

    FOUND SUB FLOORING IS CRACK AT FS 200. REPLACED DAMAGED SUB-FLOORING SECTION PER SRM 51-70-4. (M)

  71. 7 Oct 2003

    Floorboard, torn

    Doug DC983

    FOUND FLOORBOARD FIBERGLASS CLOTH TORN FROM UPPER SURFACE AT FS 1079-1117. REPLACED FLOORBOARD PER SRM 53-03. (M)

  72. 7 Oct 2003

    Floorboard, corroded

    Doug DC983

    FOUND DURING 15K CHECK, FLIGHT DECK FLOORBOARD DELAMINATED AND CORRODED AT FS 125-160. REPLACED FLOORBOARD PER SRM 53-05. (M)

  73. 7 Oct 2003

    Floor Support, corroded

    Doug DC983

    FOUND DURING 15K CHECK, FLOOR SUPPORT CORRODED AT FS 1098-1193. REPLACED FLOOR TRACK PER SRM 51-30-1, 51-10-2, 51-10-4, AND 51-10-3. (M)

  74. 7 Oct 2003

    Floor Panel, cracked

    Doug DC983

    FOUND DURING 15K CHECK, FLOOR PANEL HAS MULTIPLE CRACKS AND PUNCTURES ON BOTTOM SURFACE AT FS 796-826. REPLACED FLOOR PANEL PER SRM 53-05. (M)

  75. 7 Oct 2003

    Floor Panel, debonded

    Doug DC983

    FOUND DURING 15K CHECK, FLOOR PANEL DISBONDED AT EDGE AT FS 769-826. REPLACED FLOOR PANEL PER SRM 53-05. (M)

  76. 7 Oct 2003

    Seat Track, corroded

    Doug DC983

    OKC - FOUND 15K CHECK, CABIN SEAT TRACK IS CORRODED AT FS 1098-1217. REPLACED SEAT TRACK PER SRM 53-05. (M)

  77. 7 Oct 2003

    Floorboard, corroded

    Doug DC983

    FOUND DURING 15K CHECK, CABIN FLOORBOARD HAS CORRODED AND SOME MISSING INSERTS AT FS 160-200. REPLACED FLOORBOARD PER SRM 53-05. (M0

  78. 7 Oct 2003

    Floorboard, corroded

    Doug DC983

    FOUND DURING 15K CHECK, FLOORBOARD HAS CORRODED AND SOME MISSING INSERTS AT FS 160-200. REPLACED FLOORBOARD PER SRM 53-05. (M)

  79. 7 Oct 2003

    Floorboard, corroded

    Doug DC983

    FOUND DURING 15K CHECK, FLIGHT DECK HAS CORRODED FLOORBOARD INSERTS AT FS 150-160. REPLACED FLOORBOARD PER SRM 53-05. (M)

  80. 7 Oct 2003

    Floorboard, debonded

    Doug DC983

    FOUND DURING 15K CHECK, CABIN FLOOR PANEL IS DISBONDING AROUND INSERTS AT FS 190-256. REPLACED FLOORBOARD [ER SRM 53-05. (M)

  81. 7 Oct 2003

    Floorboard, corroded

    Doug DC983

    FOUND DURING 15K CHECK, CABIN FLOOR PANEL IS CORRODED AROUND INSERTS AT FS 160-190. REPLACED FLOORBOARD PER SRM 53-05. (M)

  82. 7 Oct 2003

    Floorboard, corroded

    Doug DC983

    FOUND DURING 15K CHECK, CABIN FLOORBOARD JUST INSIDE L1 ENTRY IS CORRODED AROUND INSERTS AT FS 148-196. REPLACED FLOORBOARD PER SRM 53-05. (M)

  83. 7 Oct 2003

    Floorboard, damaged

    Doug DC983

    FOUND DURING 15K CHECK, CABIN FLOORBOARD HAS SEVERAL WATER DAMAGED INSERTS AT FS 218-256. REPLACED FLOORBOARD IAW SRM 53-05. (M)

  84. 7 Oct 2003

    Floorboard, delaminated

    Doug DC983

    FOUND DURING 15K CHECK, CABIN FLOOR PANEL IS DELAMINATED IN TWO PLACES BETWEEN FS 465-541. REPLACED FLOORBOARD IAW SRM 53-05. (M)

  85. 7 Oct 2003

    Floorboard, debonded

    Doug DC983

    DURING 15K CHECK FOUND CABIN FLOOR PANEL IS DISBODED AT CORNER AND CREASED THROUGH MIDDLE AT FS 465-522. REPLACED FLOORBOARD PER SRM 53-05. (M)

  86. 7 Oct 2003

    Floorboard, delaminated

    Doug DC983

    OKC - FOUND DURING 15K CHECK, CABIN FLOOR PANEL IS DELAMINATED AT TWO LOCATIONS BETWEEN FS 541 AND 617. REPLACED FLOORBOARD PER SRM 53-05. (M)

  87. 7 Oct 2003

    Floorboard, corroded

    Doug DC983

    FOUND DURING 15K CHECK, CABIN FLOORBOARD IS CORRODED BETWEEN FS 598-636. REPLACED FLOORBOARD PER SRM 53-24-0. (M)

  88. 7 Oct 2003

    Floorboard, damaged

    Doug DC983

    FOUND DURING 15K CHECK, CABIN FLOOR EDGES HAVE BEEN WATER DAMAGED BETWEEN FS 1003 AND 1074. REPLACED FLOORBOARD PER SRM 53-24-0. (M)

  89. 7 Oct 2003

    Floorboard, broken

    Doug DC983

    FOUND DURING 15K CHECK, CABIN FLOOR INSERTS ARE DAMGED, SOME BROKEN AND SOME PULLED, BETWEEN FS 1117 AND 1174. REPLACED FLOORBOARD PER SRM 53-05. (M)

  90. 23 Sep 2003

    Seat Track, corroded

    Doug DC983

    OKC - DURING 15K CHECK, FOUND SEAT TRACK IS CORRODED FROM FS 1098 TO 1193. REPLACED TRACK IAW SRM 51-30-1, 10-2, 10-4, AND 10-3. (M)

  91. 9 Mar 2003

    Light, malfunctioned

    Doug DC983

    OAK - DURING LINE CHECK, FOUND PORTABLE EMERGENCY LIGHT AT FORWARD ENTRY DOOR WOULD NOT EXTINGUISH WITH SWITCH OFF. REPLACED LIGHT ASSEMBLY. LIGHT THEN…

  92. 30 Jan 2003

    Light, malfunctioned

    Doug DC983

    PDX - DURING LINE CHECK, FOUND PORTABLE EMERGENCY LIGHT AT FORWARD ENTRY DOOR ILLUMINATED WITH SWITCH TURNED OFF. REPLACED LIGHT ASSEMBLY, INCLUDING BATTERY…

  93. 20 Dec 2002

    Lanyard, disconnected

    Doug DC983

    SJC - DURING PREFLIGHT CHECK, R-1 DOOR EMERGENCY SLIDE LANYARD WAS FOUND TO BE DETACHED. REATTACHED LANYARD. (M)

  94. 23 Oct 2002

    Harness, failed

    Doug DC983

    DURING C CHECK, FORWARD SERVICE DOOR EMERGENCY SLIDE HARNESS FAILED SYSTEM CHECK. REPLACED EMERGENCY SLIDE. SYSTEM CHECKED, OK.

  95. 19 Oct 2002

    Wire, disconnected

    Doug DC983

    DURING LINE CHECK, FOUND EMERGENCY TRACK LIGHT INOPERATIVE AT ROW 21. REPLACED CONNECTOR WIRE. LIGHTS THEN OPERATED PROPERLY. (M)

  96. 17 Oct 2002

    Door Frame, corroded

    Doug DC983

    OAK - FOUND C-CHECK, AFT CARGO BAY DOOR JAMB BEAM IS CORRODED IN SEVERAL PLACES. REMOVED CORRODED AREA, ADDED FILLER, AND INSTALLED DOUBLER PER EA 5310-02122.…

  97. 21 Sep 2002

    Mechanism, out of adjust

    Doug DC983

    SEA - FOUND L1 DOOR DIFFICULT TO OPEN. ADJUSTED DOOR MECHANISM. DOOR THEN OPENED NORMALLY. (M)

  98. 26 Aug 2002

    Module, disconnected

    Doug DC983

    PDX - DURING PREFLIGHT CHECK, FOUND EMERGENCY TRACK LIGHTS WERE FOUND TO BE INOPERATIVE AT ROW 7. RECONNECTED DISCONNECTED LIGHT MODULE. LIGHTS THEN OPERATED…

  99. 25 Aug 2002

    Light, inoperative

    Doug DC983

    PDX - DURING LINE CHECK, FOUND PORTABLE EMERGENCY LIGHT ON AND WILL NOT TURN OFF. REPLACED PORTABLE LIGHT ASSEMBLY. LIGHT THEN OPERATED NORMALLY. (M)

  100. 22 Aug 2002

    Module, inoperative

    Doug DC983

    SEA - DURING LINE CHECK, NUMEROUS EMERGENCY TRACK LIGHTS WERE FOUND TO BE INOPERATIVE IN FORWARD CABIN. REPLACED INOPERATIVE MODULES. LIGHTS THEN OPERATED…

  101. 21 Aug 2002

    Module, inoperative

    Doug DC983

    SEA - DURING PREFLIGHT CHECK, FOUND EMERGENCY TRACK LIGHTING INOPERATIVE IN 1ST CLASS CABIN. REPLACED A LIGHT MODULE. LIGHTS THEN OPERATED PROPERLY. (M)

  102. 18 Aug 2002

    Light, inoperative

    Doug DC983

    LAX - DURING PREFLIGHT CHECK, FOUND EMERGENCY TRACK LIGHTS INOPERATIVE IN VARIOUS LOCATIONS THROUGH OUT CABIN. RECONNECTED/REPAIRED LIGHTS. LIGHT THEN…

  103. 27 Jul 2002

    Plug, out of position

    Doug DC983

    PDX - DURING LINE MAINTENANCE CHECK, EMERGENCY TRACK LIGHTING WAS INOPERATIVE ROWS 6-9. REINSTALLED PLUG IN TRACK LIGHTING MODULE. LIGHTS THEN OPERATED…

  104. 23 Jul 2002

    Wire, disconnected

    Doug DC983

    PDX - DURING LINE CHECK, EMERGENCY TRACK LIGHTING WAS INOPERATIVE FROM ROW 6 TO 9. RECONNECTED WIRING TO LIGHT MODULE CONNECTOR. LIGHTS THEN OPERATED…

  105. 15 Jul 2002

    Lanyard, disconnected

    Doug DC983

    PHX - DURING PRE-FLIGHT CHECK, THE AFT SERVICE DOOR EMERGENCY SLIDE LANYARD WAS FOUND TO BE DETACHED. REATTACHED LANYARD. (M)

  106. 29 May 2002

    Light, inoperative

    Doug DC983

    LAX - DURING LINE CHECK, FOUND PORTABLE EMERGENCY LIGHT TO BE INOPERATIVE. REPLACED PORTABLE LIGHT. OP TESTED OK. (M)

  107. 7 Mar 2002

    Pin, missing

    Doug DC983

    PDX - DURING PREFLIGHT CHECK, THE CAPTAINS SLIDING CLEARVIEW WINDOW COULD NOT BE OPENED. REINSTALLED PIN IN WINDOW HINGE LINKAGE. WINDOW THEN OPERATED…

  108. 4 Mar 2002

    Battery, discharged

    Doug DC983

    OAK - DURING LINE CHECK, FOUND PORTABLE EMERGENCY LIGHT TO BE INOPERATIVE. REPLACED PORTABLE LIGHT. OP TESTED OK. (M)

  109. 23 Feb 2002

    Lanyard, disconnected

    Doug DC983

    SEA - FORWARD GALLEY DOOR LANYARD BETWEEN GIRT BAR AND SLIDE COVER BECAME DISCONNECTED. REATTACHED LANYARD. (M)

  110. 23 Sep 2001

    Lanyard, detached

    Doug DC983

    SEA - DURING PRE-FLIGHT CHECK, R-1 DOOR EMERGENCY SLIDE GIRT BAR TO LATCH LANYARD WAS FOUND DETACHED. REATTACHED LANYARD. (M)

  111. 23 Sep 2001

    Module, inoperative

    Doug DC983

    LAX - DURING PREFLIGHT CHECK, DETERMINED EMERGENCY TRACK LIGHTING TO BE INOPERATIVE AT ROW 30. REPLACED LIGHT MODULE SOCKET AND RELAMPED. LIGHTS THEN OPERATED…

  112. 21 Aug 2001

    Module, disconnected

    Doug DC983

    ANC - DURING PREFLIGHT CHECK, EMERGENCY FLOOR TRACK LIGHTING WAS INOPERATIVE IN 1ST CLASS CABIN. RECONNECTED LOOSE LIGHT MODULES. LIGHT THEN OPERATED…

  113. 12 Aug 2001

    Coalescer Bag, dirty

    Doug DC983

    ZIH - DURING CLIMB AT 10K FEET ALTITUDE, BURNING RUBBER/ELECTRICAL FIRE SMELL WAS DETECTED IN VICINITY OF ROW 15. REMOVED OVERHEAD PANELS AT ROWS 13-17 AND…

  114. 17 Jun 2001

    Lanyard, disconnected

    Doug DC983

    SEA - DURING PREFLIGHT CHECK, R1 DOOR EMERGENCY SLIDE LANYARD WAS FOUND TO BE DETACHED FROM DOOR. REATTACHED LANYARD BETWEEN GIRT BAR AND DOOR SLIDE COVER. (M)

  115. 11 Jun 2001

    Door, out of rig

    Doug DC983

    JUN - AFTER TAXI UP TO GATE, L1 DOOR FORWARD LEFT CREW/PAX DOOR WAS FOUND TO BE DIFFICULT TO OPEN. RIGGED L1 DOOR. THE DOOR THEN OPERATED PROPERLY. (M)

  116. 7 Jun 2001

    Light, inoperative

    Doug DC983

    OAK - DURING C-CHECK, THE LEFT FORWARD ENTRY PORTABLE EMERGENCY EXIT LIGHT WAS FOUND TO BE INOPERATIVE. REPLACED THE PORTABLE EMERGENCY LIGHT ASSEMBLY WITH A…

  117. 5 Jun 2001

    Slide, failed

    Doug DC983

    OAK - DURING C-CHECK, AFT REAR DOOR EMERGENCY SLIDE HARNESS FAILED SYSTEM CHECK. REPLACED EMERGENCY SLIDE PER T/C 24653002. SYSTEM CHECKED OK. (M)

  118. 5 Jun 2001

    Skin, damaged

    Doug DC983

    SEA - DURING LINE CHECK, FOUND RIGHT LOWER WING DAMAGE AT XRS 509.5 FROM FRONT TO REAR REAR. INITIATED PERIODIC INSPECTION PER EA 5720-01193, WITH FINAL…

  119. 16 May 2001

    Light, inoperative

    Doug DC983

    ANC - DURING LINE CHECK, FOUND SOME EMERGENCY FLOOR TRACK LIGHTS INOPERATIVE THROUGHOUT CABIN. RESEATED TRACK LIGHTING MODULES. LIGHTS THEN OPERATED PROPERLY.…

  120. 15 May 2001

    Light, inoperative

    Doug DC983

    PDX - DURING SERVICE CHECK, FOUND SEVERAL EMERGENCY FLOOR TRACK LIGHTS INOPERATIVE IN 1ST CLASS CABIN ON RIGHT SIDE. RESEATED TRACK LIGHTING MODULES. LIGHTS…

  121. 7 May 2001

    Light, inoperative

    Doug DC983

    PDX - DURING LINE CHECK, FOUND EMERGENCY FLOOR TRACK LIGHTING INOPERATIVE AT ROWS 6, 7 AND 8. REPLACED TRACK LIGHTING BASE AND COVER IAW EA 3350-01014. LIGHTS…

  122. 21 Apr 2001

    Light, inoperative

    Doug DC983

    SEA - DURING LINE CHECK, FOUND EMERGENCY FLOOR TRACK LIGHTING INOPERATIVE AT ROW 6-7. REPLACED LAMP MODULE. LIGHTS THEN OPERATED PROPERLY. (M)

  123. 13 Mar 2001

    Light, inoperative

    Doug DC983

    SEA - DURING SERVICE CHECK, FORWARD CABIN PORTABLE EMERGENCY LIGHT WAS DETERMINED TO BE INOPERATIVE. REPLACED LIGHT ASSEMBLY. LIGHT THEN OPERATED PROPERLY. (M)

  124. 10 Mar 2001

    Lanyard, disconnected

    Doug DC983

    SEA - DURING PRE-FLIGHT CHECK, R-1 DOOR EMERGENCY SLIDE LANYARD WAS FOUND TO BE PULLED OUT OF PLACE. REINSTALLED LANYARD PROPERLY. (M)

  125. 11 Feb 2001

    Lanyard, disconnected

    Doug DC983

    ANC - DURING PREFLIGHT CHECK, L2 DOOR EMERGENCY SLIDE LANYARD WAS FOUND TO BE DETACHED. REATTACHED LANYARD BETWEEN GIRT BAR AND SLIDE COVER. (M)

  126. 11 May 2000

    Wire, disconnected

    Doug DC983

    SEA - PRIOR TO DEPARTURE, THE EMERGENCY EXIT FLOOR TRACK LIGHTS AT ROWS 6 AND 7 WERE FOUND INOPERATIVE. RECONNECTED LOOSE WIRING AND LIGHTS OPERATED NORMALLY.…

  127. 6 Mar 2000

    Battery Pack, will not test

    Doug DC983

    PHX - DURING 30K CHECK, THE OVERWING EMERGENCY EXIT LIGHTS FAILED THE LUMINOSITY CHECK. REPLACED THE BATTERY PACK AND THE LIGHTS OPERATED NORMALLY. (X)

  128. 6 Mar 2000

    Skin, corroded

    Doug DC983

    PHX - DURING 30K CHECK, THE FUSELAGE AT FS 826 WAS FOUND CORRODED ON THE UNDERWING BELLY SKIN, OUTER SURFACE. REMOVED CORROSION AND REPAIRED PER EA 5310-01803…

  129. 6 Mar 2000

    Frame, misrepaired

    Doug DC983

    PHX - DURING 30K CHECK, WHILE ACCOMPLISHING FRAME REPAIR OF A DENT AT FS 731, LONGERON 24L PER PRELIMINARY EA 1590-EG-0005, ADDITIONAL DAMAGE IN THE FORM OF…

  130. 6 Mar 2000

    Skin, chafed

    Doug DC983

    PHX - DURING 30K CHECK, THE CENTER CARGO DOOR WAS FOUND CHAFED ON THE DOOR INNER PAN AT BOTH HINGE ARM CUTOUT LOCATIONS. REPAIRED PER EA 5230-01105 AND EA…

  131. 6 Mar 2000

    Pan, gouged

    Doug DC983

    PHX - DURING 30K CHECK, THE CENTER CARGO DOOR WAS FOUND GOUGED ON THE INNER PAN OF THE DOOR ON THE AFT SIDE. REPAIRED PER EA 5230-01109 AND EA 10-5230-0316. (M)

  132. 6 Mar 2000

    Spar Cap, damaged

    Doug DC983

    PHX - DURING 30K CHECK, FOUND AN ELONGATED LEADING EDGE CAP ATTACH FASTENER HOLE IN THE LEFT HORIZONTAL STABILIZER FORWARD LOWER SPAR CAP FLANGE AT STATION…

  133. 29 Feb 2000

    Floorbeam, corroded

    Doug DC983

    PHX - DURING 30K CHECK, THE RIGHT CABIN FLOOR CUSP BEAM WAS FOUND CORRODED BETWEEN FS 484 AND 503. REPAIRED PER SRM 53-10-3. (M)

  134. 29 Feb 2000

    Longeron, corroded

    Doug DC983

    PHX - DURING 30K CHECK, THE AFT CARGO COMPARTMENT FS 1231, BEAM LONGERON 29R, WAS FOUND CORRODED AT THE RADIUS OF THE LOWER HORIZONTAL LEG. REPAIRED PER SRM…

  135. 27 Feb 2000

    Slide, failed

    Doug DC983

    PHX - DURING 30K CHECK, THE TAILCONE EXIT EMERGENCY EVACUATION SLIDE FAILED THE EMERGENCY LIGHT AMP TEST. REPLACED THE TAILCONE EXIT EMERGENCY EVACUATION…

  136. 20 Feb 2000

    Shear Tie, corroded

    Doug DC983

    PHX - DURING SCHEDULED 30K CHECK, THE AFT CARGO COMPARTMENT STATION 1287 BETWEEN LONGERON 29L TO 30L SHEAR TIE WAS FOUND TO BE CORRODED. REPAIRED PER SRM. (M)

  137. 18 Feb 2000

    Floor Support, corroded

    Doug DC983

    PHX - DURING 30K CHECK, THE MAIN CABIN FLOOR SUPPORT AT FS 180, RBL 25 WAS FOUND CORRODED. REPAIRED PER SRM 53-14-1, FIG 11. (M)

  138. 18 Feb 2000

    Web, corroded

    Doug DC983

    PHX - DURING 30K CHECK, THE SUB FLOOR WEB AT FS 148-156, RBL 53 WAS FOUND CORRODED. REPAIRED PER SRM 53-01. (M)

  139. 18 Feb 2000

    Fitting, corroded

    Doug DC983

    PHX - DURING 30K CHECK, THE MAIN CABIN FLOOR SUPPORT MOUNT FITTING AT FS 160, RBL 10 WAS FOUND CORRODED. REPAIRED PER SRM 51-30. (M)

  140. 18 Feb 2000

    Floor Support, corroded

    Doug DC983

    PHX - DURING 30K CHECK, THE MAIN CABIN FLOOR SUPPORT AT LBL 6, FS 160-200 WAS FOUND CORRODED. REPAIRED PER SRM 51-30. (M)

  141. 18 Feb 2000

    Floor Support, corroded

    Doug DC983

    PHX - DURING 30K CHECK, THE FLOOR SUPPORT AT FS 160-200, RBL 6 WAS FOUND CORRODED. REPAIRED PER SRM 53-14-1. (M)

  142. 18 Feb 2000

    Floor Support, corroded

    Doug DC983

    PHX - DURING 30K CHECK, THE MAIN CABIN FLOOR SUPPORT AT L1 DOOR, FS 160-200, LBL 45 WAS FOUND CORRODED. REPAIRED PER SRM 51-30. (M)

  143. 18 Feb 2000

    Floor Support, corroded

    Doug DC983

    PHX - DURING 30K CHECK, THE MAIN CABIN FLOOR SUPPORT AT L1 DOOR, FS 160-200, LBL 50 WAS FOUND CORRODED. REPAIRED PER SRM 51-30. (M)

  144. 18 Feb 2000

    Floor Support, corroded

    Doug DC983

    PHX - DURING 30K CHECK, THE MAIN CABIN FLOOR SUPPORT AT FS 160-200, RBL 50 WAS FOUND CORRODED. REPAIRED PER SRM 51-30-2. (M)

  145. 18 Feb 2000

    Web, corroded

    Doug DC983

    PHX - DURING 30 K CHECK, THE MAIN CABIN FLOOR WEB AT FS 160-200, RBL 56 T0 LBL 56 WAS FOUND CORRODED. REPAIRED PER SRM 51-30. (M)

  146. 18 Feb 2000

    Floor Support, corroded

    Doug DC983

    PHX - DURING 30K CHECK, THE MAIN CABIN FLOOR SUPPORT AT FS 200, BL 0 WAS FOUND CORRODED. REPAIRED PER SRM 53-14-1, FIG 11. (M)

  147. 18 Feb 2000

    Floor Support, corroded

    Doug DC983

    PHX - DURING 30K CHECK, THE MAIN CABIN FLOOR SUPPORT AT FS 200, RBL 9 TO 43 WAS FOUND CORRODED. REPAIRED PER SRM 51-30. (M)

  148. 18 Feb 2000

    Floor Support, corroded

    Doug DC983

    PHX - DURING 30K CHECK, THE MAIN CABIN FLOOR SUPPORT AT FS 200, LBL 13 WAS FOUND CORRODED. REPAIRED PER SRM 51-30. (M)

  149. 18 Feb 2000

    Floor Support, corroded

    Doug DC983

    PHX - DURING 30K CHECK, THE MAIN CABIN FLOOR SUPPORT AT FS 200, RBL 45-55 WAS FOUND CORRODED. REPAIRED PER SRM 51-30. (M)

  150. 18 Feb 2000

    Floor Support, corroded

    Doug DC983

    PHX - DURING 30K CHECK, THE MAIN CABIN FLOOR SUPPORT AT FS 200, LBL 56 WAS FOUND CORRODED. REPAIRED PER SRM 51-30. (M)

  151. 18 Feb 2000

    Channel, corroded

    Doug DC983

    PHX - DURING 30K CHECK, THE MAIN CABIN FLOOR U-CHANNEL FOR THE GALLEY ATTACH FITTING WAS FOUND CORRODED AT FS 200-218, RBL 55. REPAIRED PER SRM 51-30. (M)

  152. 18 Feb 2000

    Floor Support, corroded

    Doug DC983

    PHX - DURING 30K CHECK, THE MAIN CABIN FLOORBOARD SUPPORT AT STATION 200, RBL 58 WAS FOUND CORRODED. REPAIRED PER SRM 51-30. (M)

  153. 18 Feb 2000

    Web, corroded

    Doug DC983

    PHX - DURING 30K CHECK, THE MAIN CABIN CUSP BEAM WEB AT FS 446 AND 465, RBL 56 WAS FOUND CORRODED. REPAIRED PER SRM 53-01, FIG 4. (M)

  154. 18 Feb 2000

    Beam, corroded

    Doug DC983

    PHX - DURING 30K CHECK, THE MAIN CABIN CUSP BEAM WEB AT FS 448, RBL 56 WAS FOUND CORRODED. REPAIRED PER SRM 53-01. (M)

  155. 18 Feb 2000

    Floorbeam, corroded

    Doug DC983

    PHX - DURING 30K CHECK, THE MAIN CABIN FLOOR CUSP BEAM WEB BETWEEN STATION 503 AND 579, RBL 56 WAS FOUND CORRODED. REPAIRED PER SRM 51-30-2. (M)

  156. 18 Feb 2000

    Floorbeam, corroded

    Doug DC983

    PHX - DURING 30K CHECK, THE MAIN CABIN FLOOR CUSP BEAM WEB BETWEEN STATION 588 AND 617, RBL 56 WAS FOUND CORRODED. REPAIRED PER SRM 53-01, FIG 4. (M)

  157. 18 Feb 2000

    Floorbeam, corroded

    Doug DC983

    PHX - DURING 30K CHECK, THE MAIN CABIN CUSP BEAM WEB AT STATION 636 TO 655, LBL 56 WAS FOUND CORRODED. REPAIRED PER SRM 53-01 FIG 4. (M)

  158. 18 Feb 2000

    Floorbeam, corroded

    Doug DC983

    PHX - DURING 30K CHECK, THE MAIN CABIN CUSP BEAM WEB AT FS 674 TO 693, LBL 56 WAS FOUND CORRODED. REPAIRED PER SRM 53-01 FIG 4. (M)

  159. 18 Feb 2000

    Floorbeam, corroded

    Doug DC983

    PHX - DURING 30K CHECK, THE MAIN CABIN FLOOR CUSP BEAM WEB AT FS 1041, RBL 56 WAS FOUND CORRODED. REMOVED CORROSION AND REPAIRED PER SRM 53-01, FIG 4. (M)

  160. 18 Feb 2000

    Floor Support, corroded

    Doug DC983

    PHX - DURING 30K CHECK, THE AFT CARGO COMPARTMENT FLOORBOARD SUPPORT AT FS 1155, LONGERON 28L TO 29R WAS FOUND CORRODED. REMOVED CORROSION AND REPAIRED PER…

  161. 18 Feb 2000

    Floorbeam, corroded

    Doug DC983

    PHX - DURNG 30K CHECK, THE LEFT MAIN CABIN FLOOR CUSP BEAM WEB AT FS 1174 TO 1193, LBL 56 WAS FOUND CORRODED. REMOVED CORROSION AND REPAIRED PER SRM 53-01,…

  162. 18 Feb 2000

    Floorbeam, corroded

    Doug DC983

    PHX - DURING 30K CHECK, THE LEFT MAIN CABIN FLOOR CUSP BEAM WEB AT FS 1231 TO 1250, LBL 56 WAS FOUND CORRODED. REMOVED CORROSION AND REPAIRED PER SRM 53-14-3,…

  163. 18 Feb 2000

    Web, corroded

    Doug DC983

    PHX - DURING 30K CHECK, THE WEB IN THE AFT CARGO COMPARTMENT WAS FOUND CORRODED ON THE UPPER FLANGE AT FS 1307 AND 1320 BETWEEN LONGERON 27L AND 28L. REMOVED…

  164. 18 Feb 2000

    Web, corroded

    Doug DC983

    PHX - DURING 30K CHECK, THE WEB IN THE AFT CARGO COMPARTMENT WAS FOUND CORRODED ON THE UPPER FLANGE AROUND NUTPLATE HOLES AT FS 1307 AND 1320 BETWEEN LONGERON…

  165. 18 Feb 2000

    Web, corroded

    Doug DC983

    PHX - DURING 30K CHECK, THE CUSP MEMBRANE AT FS 1142, LBL 58 ON THE TOP SURFACE WAS FOUND CORRODED. REMOVED CORROSION AND REPAIRED PER SRM 53-01. (M)

  166. 18 Feb 2000

    Seat Track, corroded

    Doug DC983

    PHX - DURING 30K CHECK, THE RIGHT MAIN CABIN SEAT TRACK AT FS 400 TO 474, RBL 22 WAS FOUND CORRODED. REMOVED CORROSION AND REPAIRED PER SRM 53-05, FIG 4B. (M)

  167. 15 Feb 2000

    Slide, will not test

    Doug DC983

    PHX - DURING 30K CHECK, THE L2 DOOR EMERGENCY EVACUATION SLIDE FAILED THE EMERGENCY LIGHT AMP TEST. REPLACED THE L2 DOOR EMERGENCY EVACUATION SLIDE ASSEMBLY.…

  168. 22 Dec 1999

    Light, inoperative

    Doug DC983

    LAX - DURING MAINTENANCE CHECK, THE FORWARD PORTABLE EMERGENCY LIGHT WAS FOUND INOPERATIVE. REPLACED THE LIGHT ASSEMBLY AND OPERATED NORMALLY. (M)

  169. 13 Nov 1999

    Connector, disconnected

    Doug DC983

    SEA DURING MAINTENANCE CHECK, THE EMERGENCY EXIT FLOOR TRACK LIGHTS AT ROWS 13 THROUGH 16 WERE FOUND INOPERATIVE. RECONNECTED CONNECTOR TO LIGHT ASSEMBLY IN…

  170. 13 Jun 1999

    Connector, loose

    Doug DC983

    PHX - PRIOR TO DEPARTURE OF FLT 721 - CREW REPORTED THE EMERGENCY FLOOR TRACK RED LIGHTS IN THE FORWARD CABIN WERE INOPERATIVE. SECURED LOOSE CONNECTOR IN…

  171. 4 Jun 1999

    Batteries, discharged

    Doug DC983

    SEA - DURING MAINTENANCE CHECK, THE OVERHEAD EMERGENCY LIGHTS BETWEEN THE AFT LAVATORIES WERE FOUND INOPERATIVE. REPLACED THE BATTERIES IN THE POWER SUPPLY…

  172. 18 Apr 1999

    Window, out of adjust

    Doug DC983

    SEA - AFTER ARRIVAL OF FLIGHT 472, CREW REPORTED THE FLIGHT COMPARTMENT RIGHT SLIDING WINDOW WOULD NOT OPEN. ADJUSTED UPPER LOCK BAR LINKAGE AND OPERATED…

  173. 26 Feb 1999

    Hinge Pin, loose

    Doug DC983

    PDX - AFTER ARRIVAL OF FLT 317, CREW REPORTED THE FLIGHT COMPARTMENT LEFT SLIDING WINDOW OPERATING MECHANISM DETACHED. FOUND WINDOW LOWER AFT HINGE PIN…

  174. 10 Feb 1999

    Power Supply, defective

    Doug DC983

    SEA - DURING MAINTENANCE CHECK, THE EXTERIOR OVERWING EMERGENCY LIGHTS WOULD NOT EXTINGUISH. REPLACED THE POWER SUPPLY AND OPERATED NORMALLY. (M)

  175. 19 Jan 1999

    Power Supply, inoperative

    Doug DC983

    PDX - DURING MAINTENANCE CHECK, THE EXTERIOR OVERWING EMERGENCY LIGHTS WERE FOUND INOPERATIVE. REPLACED THE POWER SUPPLY AND OPERATED NORMALLY. (M)

  176. 4 Jan 1999

    Window, out of adjust

    Doug DC983

    SEA - PRIOR TO DEPARTURE OF FLIGHT 231, CREW REPORTED THE FLIGHT COMPARTMENT LEFT SLIDING WINDOW WOULD NOT OPEN. ADJUSTED WINDOW MECHANISM AND OPERATED…

  177. 12 Dec 1998

    Wire, disconnected

    Doug DC983

    SEA - PRIOR TO DEPARTURE OF FLIGHT 366, CREW REPORTED THE EMERGENCY FLOOR TRACK LIGHTS FROM ROW 8 FORWARD WERE INOPERATIVE. RECONNECTED WIRING IN FLOOR TRACK…

  178. 29 Nov 1998

    Window, out of adjust

    Doug DC983

    SEA - PRIOR TO DEPARTURE OF FLIGHT 451, CREW REPORTED THE FLIGHT COMPARTMENT LEFT SLIDING WINDOW WOULD NOT OPEN. ADJUSTED WINDOW UPPER GUIDE MECHANISM AND…

  179. 3 Oct 1998

    Lock Mech, binding

    Doug DC983

    FAI - AFTER ARRIVAL OF FLIGHT 97, CREW REPORTED THE FLIGHT COMPARTMENT RIGHT SLIDING WINDOW WOULD NOT OPEN. LUBRICATED WINDOW UPPER LOCK MECHANISM AND…

  180. 3 Oct 1998

    Lock, binding

    Doug DC983

    FAI - PRIOR TO DEPARTURE OF FLIGHT 80, CREW REPORTED THE FLIGHT COMPARTMENT RIGHT SLIDING WINDOW WOULD NOT OPEN. FREED WINDOW UPPER LOCK MECHANISM AND…

  181. 16 Sep 1998

    Slide, malfunctioned

    Doug DC983

    OAK - DURING C-CHECK, THE L2 DOOR EMERGENCY EVACUATION SLIDE FAILED THE EMERGENCY LIGHT AMP TEST. REPLACED THE L2 DOOR EMERGENCY EVACUATION SLIDE ASSEMBLY. (M)

  182. 20 Aug 1998

    Batteries, discharged

    Doug DC983

    SEA - DURING MAINTENANCE CHECK, THE OVERHEAD EMERGENCY LIGHTS IN THE FORWARD ENTRY WERE FOUND INOPERATIVE. REPLACED THE BATTERIES IN THE POWER SUPPLY AND…

  183. 4 Jun 1998

    Light, inoperative

    Doug DC983

    SEA - DURING MAINTENANCE CHECK, THE RED EMERGENCY FLOOR TRACK LIGHT AT THE AFT GALLEY WAS FOUND INOPERATIVE. REPLACED LAMP MODULE AT AFT GALLEY AND OPERATED…

  184. 4 Jun 1998

    Light, inoperative

    Doug DC983

    SEA - DURING MAINTENANCE CHECK, THE OVERHEAD EMERGENCY LIGHTS IN THE CATWALK AREA WERE FOUND DIM. REPLACED SECOND FROM FORWARD LIGHT ASSEMBLY AND OPERATED…

  185. 17 May 1998

    Bearing, worn

    Doug DC983

    SEA - ARRIVAL OF FLT 88, CREW REPORTED THE L2 DOOR WOULD NOT FULLY OPEN. REPLACED THE UPPER HINGE TORQUE TUBE BEARING AND OPERATED NORMALLY. (M)

  186. 26 Mar 1998

    Wire, defective

    Doug DC983

    ONT - PRIOR TO DEPARTURE OF FLT 531, CREW REPORTED THE EMERGENCY FLOOR TRACK LIGHTS IN THE FORWARD CABIN WERE INOPERATIVE. REPAIRED WIRE IN FLOOR TRACK AND…

  187. 15 Feb 1998

    Hold Open Hook, bent

    Doug DC983

    ONT - FLT 595 - PRIOR TO DEPARTURE, CREW REPORTED THE L1 DOOR WOULD NOT CLOSE. REPLACED THE DOOR HOLD OPEN HOOK AND OPERATED NORMALLY. AIRCRAFT TT: 21,095…

  188. 5 Feb 1998

    Light, defective

    Doug DC983

    PDX - DURING MAINTENANCE CHECK, THE FORWARD PORTABLE EMERGENCY LIGHT WAS FOUND DIM. REPLACED THE LIGHT ASSEMBLY AND OPERATED NORMALLY. (M)

  189. 7 Nov 1997

    Handle Pin, broken

    Doug DC983

    SEA - AFTER ARRIVAL OF FLT 513, CREW REPORTED THE L2 DOOR HANDLE WOULD NOT CLOSE PROPERLY. REPLACED THE L2 DOOR HANDLE RETAINING PIN AND OPERATED NORMALLY. (M)

  190. 21 Oct 1997

    Retaining Pin, broken

    Doug DC983

    SEA - AFTER ARRIVAL OF FLT 191, CREW REPORTED THE L2 DOOR HANDLE WAS NOT POSITIONED CORRECTLY. REPLACED THE L2 DOOR HANDLE RETAINING PIN AND OPERATED…

  191. 17 Sep 1997

    Inflation Bottle, high pressure

    Doug DC983

    PDX - DURING MAINTENANCE CHECK, THE L1 DOOR EMERGENCY EVACUATION SLIDE INFLATION BOTTLE PRESSURE WAS FOUND HIGH. REPLACED THE L1 DOOR EMERGENCY EVACUATION…

  192. 26 Jul 1997

    Wire, broken

    Doug DC983

    SEA - DURING MAINTENANCE CHECK, THE EMERGENCY FLOOR TRACK LIGHTS FROM ROWS 6 TO 9 WERE FOUND INOPERATIVE. REPAIRED BROKEN WIRE IN TRACK AND OPERATED NORMALLY.…

  193. 15 May 1997

    Light, defective

    Doug DC983

    SEA - DURING MAINTENANCE CHECK, THE FORWARD PORTABLE EMERGENCY LIGHT WAS FOUND INOPERATIVE. REPLACED THE LIGHT ASSEMBLY AND OPERATED NORMALLY. (M)

  194. 15 May 1997

    Wire, disconnected

    Doug DC983

    SEA - DURING MAINTENANCE CHECK, THE EMERGENCY FLOOR TRACK LIGHTS FROM ROWS 6 TO 8 WERE FOUND INOPERATIVE. RECONNECTED WIRING IN TRACK ASSEMBLY AND OPERATED…

  195. 1 May 1997

    Slide, failed test

    Doug DC983

    OAK - DURING C-CHECK, THE L2 DOR EMERGENCY EVACUATION SLIDE EMERGENCY LIGHTS FAILED TEST. REPLACED THE L2 DOOR EMERGENCY EVACUATION SLIDE. (M)

  196. 1 May 1997

    Slide, failed test

    Doug DC983

    OAK - DURING C-CHECK, THE TAILCONE EMERGENCY EVACUATION SLIDE EMERGENCY LIGHTS FAILED TEST. REPLACED THE TAILCONE EMERGENCY EVACUATION SLIDE. (M)

  197. 10 Mar 1997

    Light, defective

    Doug DC983

    PDX - DURING MAINTENANCE CHECK, THE FORWARD PORTABLE EMERGENCY LIGHT WAS FOUND INOPERATIVE. REPLACED THE LIGHT ASSEMBLY AND OPERATED NORMALLY. (M)

  198. 21 Feb 1997

    Wire, broken

    Doug DC983

    SEA - DURING MAINTENANCE CHECK, THE EMERGENCY FLOOR TRACK LIGHTS FROM ROWS 6 TO 9 WERE FOUND INOPERATIVE. REPAIRED WIRING AT ROW 6 AND OPERATED NORMALLY. (M)

  199. 28 Sep 1996

    Wire, disconnected

    Doug DC983

    SEA - DURING MAINTENANCE CHECK, THE EMERGENCY FLOOR TRACK LIGHTS FROM ROWS 14 TO 16 WERE FOUND INOPERATIVE. RECONNECTED WIRE AT ROW 17 AND OPERATED NORMALLY.…

  200. 6 Sep 1996

    Light, defective

    Doug DC983

    SFO - DURING MAINTENANCE CHECK, THE FORWARD PORTABLE EMERGENCY LIGHT WAS FOUND INOPERATIVE. REPLACED THE LIGHT ASSEMBLY AND OPERATED NORMALLY. (M)

  201. 21 Aug 1996

    Wire, disconnected

    Doug DC983

    ANC - DURING MAINTENANCE CHECK, THE EMERGENCY FLOOR TRACK LIGHTS AT ROW 6 WERE FOUND INOPERATIVE. FOUND WIRING DISCONNECTED, RECONNECTED WIRING AND OPERATED…

  202. 7 Aug 1996

    Wire, disconnected

    Doug DC983

    SEA - PRIOR TO DEPARTURE OF FLT 203 - CREW REPORTED, THE EMERGENCY FLOOR TRACK LIGHTS IN THE FORWARD CABIN WERE INOPERATIVE. RECONNECTED WIRING AT ROW 3 AND…

  203. 17 Jul 1996

    Track, defective

    Doug DC983

    PDX - FLT 56 - EMERGENCY EXIT FLOOR TRACK LIGHTING INOPERATIVE ROWS S30 AND 32/33. RELAMPED AND INSTALLED NEW SECTION OF TRACK; LIGHTS OPERATED NORMALLY.…

  204. 17 Jul 1996

    Lamp, defective

    Doug DC983

    PDX - FLT 56 - EMERGENCY EXIT FLOOR TRACK LIGHTING INOPERATIVE ROWS S30 AND 32/33. RELAMPED AND INSTALLED NEW SECTION OF TRACK; LIGHTS OPERATED NORMALLY.…

  205. 6 Jul 1996

    Wire, broken

    Doug DC983

    LAX - DURING MAINTENANCE CHECK, THE EMERGENCY FLOOR TRACK LIGHTSFROM ROW 30 AFT WERE FOUND INOPERATIVE. REPAIRED BROKEN WIRE AT ROW 31 ANDOPERATED NORMALLY. (M)

  206. 1 Jun 1996

    Wire, disconnected

    Doug DC983

    SEA - DURING MAINTENANCE CHECK, THE EMERGENCY FLOOR TRACK LIGHTS IN THE FORWARD CABIN WERE FOUND INOPERATIVE. RECONNECTED WIRING AT ROW 2 AND OPERATED…

  207. 10 Mar 1996

    Track Light, defective

    Doug DC983

    SEA - DURING MAINTENANCE CHECK, THE FORWARD SECTION OF EMERGENCY FLOOR TRACK LIGHTS WERE FOUND INOPERATIVE. REPLACED LIGHT ASSEMBLY AT ROW 2 AND OPERATED…

  208. 26 Feb 1996

    Wire, disconnected

    Doug DC983

    SEA - DURING MAINTENANCE CHECK, THE EMERGENCY FLOOR TRACK LIGHTS FROM ROWS 25 TO 28 WERE FOUND INOPERATIVE. RECONNECTED WIRING AND OPERATED NORMALLY. (M)

  209. 25 Nov 1995

    Light, defective

    Doug DC983

    SEA - DURING MAINTENANCE CHECK, THE FORWARD PORTABLE EMERGENCY LIGHT WAS FOUND INOPERATIVE. REPLACED THE LIGHT ASSEMBLY AND OPERATED NORMALLY. (M)

  210. 13 Jan 1995

    Eel Wiring, disconnected

    Doug DC983

    LAX - FLT 255 - PRIOR TO DEPARTURE, CREW REPORTED THE EMERGENCY EXIT FLOOR TRACK LIGHTS AT THE OVERWING EXIT AREA WERE INOPERATIVE. REPAIRED BROKEN WIRING IN…

Copied daily from public FCC, FAA and NTSB downloads. Not affiliated with any of them.

sources and dates
sourcerecordsas of
FCC amateur1,702,05223 Nov 2026
FCC GMRS633,26623 Nov 2026
FCC ship radio403,52022 Nov 2026
FCC antenna structures198,13522 Nov 2026
FCC aircraft radio153,38322 Nov 2026
FAA airmen910,1651 Nov 2026
FAA deregistered aircraft383,80320 Nov 2026
FAA registered aircraft319,53720 Nov 2026
FAA N-number reservations125,98920 Nov 2026
FAA dealers12,50720 Nov 2026
FAA airports19,43329 Oct 2026
FAA service difficulty reports1,699,08023 Nov 2026
NTSB accidents, 1982 on88,0301 Nov 2026

History is kept: records the agencies stop publishing stay here, marked with the date they left.

Airmen who keep their address private aren't in the FAA's download, so they aren't here.

Not a consumer report: don't use it to screen anyone for a job, a lease, credit or insurance.

To hide your address here, email george.main@gemiv.net.