210 reports
- 10 Jul 2007
Longeron, dented
FUSELAGE DENTED. REPAIR FUSELAGE SKIN AND LONGERON PER SRM 53-02.
- 29 Mar 2007
Skin, dented
FUSELAGE SKIN DENTED. REMOVED DAMAGED AREA. INSTALLED SKIN FILLER INTERNAL FINGER DOUBLERS INTERNAL REPAIR DOUBLERS AND INTERNAL REPAIR STRAPS PER SRM 53-04.
- 29 Mar 2007
Skin, dented
FUSELAGE DENTED. REMOVED DAMAGED AREA. INSTALLED SKIN FILLER INTERNAL REPAIR DOUBLERS REPAIR STRAPS AND FINGER DOUBLERS PER SRM 53-04.
- 29 Mar 2007
Seat Track, corroded
CABIN SEAT TRACK CORRODED. REMOVED DAMAGED SECTION OF TRACK. INSTALLED REPAIR TRACK AND SPLICE PER SRM 53-05.
- 29 Mar 2007
Doubler, chafed
LEFT WING OUTBOARD FLAP CENTER VANE IS CHAFED ON EXISTING REPAIR DOUBLER. REPLACED DOUBLER PER SRM 51-70-2.
- 29 Mar 2007
Doubler, gouged
RIGHTHAND OUTBOARD FLAP VANE LEADING EDGE IS GOUGED AT PREVIOUS REPAIR. REPLACED EXISTING REPAIR DOUBLER PER SRM 51-70-2.
- 29 Mar 2007
Vane, gouged
RIGHTHAND OUTBOARD FLAP OUTBOARD VANE IS GOUGED. INSTALLED REPAIR DOUBLER PER SRM 51-70-2.
- 29 Mar 2007
Vane, gouged
LEFTHAND OUTBOARD FLAP OUTBOARD VANE IS GOUGED. INSTALLED REPAIR DOUBLER PER SRM 51-70-2.
- 28 Mar 2007
Intercostal, cracked
AFT ACCESSORY INTERCOSTAL CRACKED. REPLACED INTERCOSTAL PER SRM 51-10-4 AND 51-30-2.
- 28 Mar 2007
Floor Panel, corroded
CABIN FLOOR PANEL CORRODED. REPLACED PANEL PER SRM 51-10-3 AND DAC DWG 9932816.
- 28 Mar 2007
Floor Panel, corroded
CABIN FLOOR PANEL CORRODED. REPLACED PANEL PER SRM 53-05 AND DAC DWG S4932106.
- 28 Mar 2007
Floor Panel, punctured
CABIN FLOOR PANEL PUNCTURED. REPLACED PANEL PER SRM 53-05 AND DAC DWG S4932106.
- 28 Mar 2007
Floor Panel, punctured
CABIN FLOOR PANEL PUNCTURED. REPLACED PANEL PER SRM 53-05 AND DAC DWG S4932106.
- 28 Mar 2007
Floor Panel, cracked
CABIN FLOOR PANEL WEB IS CRACKED. REMOVED DAMAGED SECTION. INSTALLED REPAIR FILLER AND DOUBLER PER SRM 51-70.
- 28 Mar 2007
Floor Panel, cracked
CABIN FLOOR WEB IS CRACKED. REMOVED DAMAGED SECTION. INSTALLED REPAIR FILLER AND DOUBLER PER SRM 51-70-4.
- 28 Mar 2007
Floor Panel, punctured
CABIN FLOOR PANEL PUNCTURED. REPLACED PANEL PER SRM 53-05 AND DAC DWG S4932106.
- 28 Mar 2007
Floor Panel, punctured
CABIN FLOOR PANEL PUNCTURED. REMOVED DAMAGED SECTION. APPLIED FILLER PLIES.
- 13 Mar 2007
Slide, malfunctioned
AFT ACCY COMPARTMENT EMERGENCY ESCAPE SLIDE FAILED TO DEPLOY DURING DEPLOYMENT TEST. INDICATION WAS THAT THE TAIL CONE STRAP (LANYARD) DETACHED FROM THE SLIDE…
- 15 Jan 2006
Longeron, corroded
C-CHECK, LONGERON CORRODED. REPLACED DAMAGED SECTION WITH SPLICES. (K)
- 15 Jan 2006
Floor Panel, punctured
C-CHECK, CABIN FLOOR PANEL PUNCTURED. REPLACED FLOOR PANEL. (K)
- 15 Jan 2006
Floor Panel, gouged
C-CHECK, CABIN FLOOR PANEL GOUGED. REPLACED FLOOR PANEL. (K)
- 15 Jan 2006
Floor Panel, delaminated
C-CHECK, CABIN FLOOR PANEL DELAMINATED. REPLACED FLOOR PANEL. (K)
- 15 Jan 2006
Floor Panel, delaminated
C-CHECK, CABIN FLOOR PANEL DELAMINATED AT FASTENER LOCATIONS. REPLACED FLOOR PANEL. (K)
- 15 Jan 2006
Floor Panel, delaminated
C-CHECK, CABIN FLOOR PANEL DELAMINATED. REMOVED DAMAGED AREA. APPLIED GLASS CLOTH REPAIR. (K)
- 15 Jan 2006
Floor Panel, delaminated
C-CHECK, CABIN FLOOR PANEL DELAMINATED. REMOVED DAMAGED AREA. APPLIED GLASS CLOTH REPAIR. (K)
- 15 Jan 2006
Floor Panel, delaminated
C-CHECK, CABIN FLOOR PANEL DELAMINATED. REMOVED DAMAGE AREA. APPLIED GLASS CLOTH REPAIR. (K)
- 15 Jan 2006
Floor Panel, delaminated
C-CHECK, CABIN FLOOR PANEL DELAMINATED. REMOVED DAMAGED AREA. APPLIED GLASS CLOTH REPAIR. (K)
- 15 Jan 2006
Floor Panel, delaminated
C-CHECK, CABIN FLOOR PANEL DELAMINATED. REMOVED DAMAGED AREA. APPLIED GLASS CLOTH REPAIR. (K)
- 15 Jan 2006
Floor Panel, delaminated
C-CHECK, CABIN FLOOR PANEL DELAMINATED. REMOVED DAMAGED AREA. APPLIED GLASS CLOTH REPAIR. (K)
- 15 Jan 2006
Floor Panel, delaminated
C-CHECK, CABIN FLOOR PANEL DELAMINATED. REMOVED DAMAGED AREA. APPLIED GLASS CLOTH REPAIR. (K)
- 15 Jan 2006
Floor Panel, delaminated
C-CHECK, CABIN FLOOR PANEL DELAMINATED. REMOVED DAMAGED AREA. APPLIED GLASS CLOTH REPAIR. (K)
- 15 Jan 2006
Floor Panel, delaminated
C-CHECK, CABIN FLOOR PANEL DELAMINATED. REMOVED DAMAGED AREA. APPLIED GLASS CLOTH REPAIR. (K)
- 15 Jan 2006
Cusp Web, corroded
C-CHECK, CABIN FLOOR CUSP WEB CORRODED. REMOVED DAMAGED SECTION. INSTALLED REPAIR DOUBLER AND FILLER. (K)
- 15 Jan 2006
Skin, dented
C-CHECK, FUSELAGE DENTED. REMOVED DAMAGED SECTION. INSTALLED INTERNAL DOUBLERS, FINGER DOUBLERS, AND INTERNAL STRAP. (K)
- 15 Jan 2006
Skin, dented
C-CHECK, FUSELAGE DENTED. REMOVED DAMAGED SECTION. INSTALLED INTERNAL DOUBLERS AND INTERNAL STRAPS. (K)
- 15 Jan 2006
Skin, gouged
C-CHECK, LT WING OB FLAP IB VANE IS GOUGED OF LEADING EDGE. REMOVED DAMAGED SECTION. INSTALLED REPAIR DOUBLER AND FILLER. (K)
- 15 Jan 2006
Skin, debonded
C-CHECK, LT WING OB FLAP CENTER PREVIOUS SKIN REPAIR IS DEBONDED. REMOVED DAMAGED SECTION. INSTALLED REPAIR DOUBLER AND FILLER. (K)
- 15 Jan 2006
Skin, nicked
C-CHECK, RT WING OB FORE FLAP CENTER DENTED ON LE PREVIOUS REPAIR. REMOVED DAMAGED SECTION. INSTALLED REPAIR DOUBLER AND FILLER. (K)
- 15 Jan 2006
Skin, dented
C-CHECK, FUSELAGE SKIN DENTED. COLD-WORKED AREA BACK TO ORIGINAL CONTOUR AND INSTALLED REPAIR DOUBLER. (K)
- 15 Jan 2006
Torque Tube, corroded
C-CHECK, RUDDER TAB TORQUE TUBE LOWER SPLINES CORRODED. REPLACED RUDDER TAB TORQUE TUBE SHAFT ASSEMBLY. (K)
- 15 Jan 2006
Crank Assy, corroded
C-CHECK, RUDDER TAB TORQUE TUBE CONTROL CRANK SPLINES CORRODED. REPLACED TORQUE TUB CONTROL CRANK ASSY. (K)
- 15 Jan 2006
Spline, corroded
C-CHECK, RUDDER TAB TORQUE TUBE SPLINE CORRODED. REPLACED RUDDER TAB TORQUE TUBE. (K)
- 15 Jan 2006
Spring, corroded
C-CHECK, RUDDER LOAD FEEL AND TRIM SPRING ASSEMBLY CORRODED. REPLACED RUDDER LOAD FEEL AND TRIM SPRING ASSEMBLY. (K)
- 15 Jan 2005
Longeron, corroded
C-CHECK, LONGERON CORRODED. REPLACED LONGERON. (K)
- 30 Oct 2004
Wire Harness, misrouted
SEA BTB NON-ROUTINE LINE CHECK-SPARKS AND SMOKE NOTED COMING FROM OVERHEAD GRILL BETWEEN L1 DOOR AND FORWARD GALLEY. INSP REVEALED THAT A WIRE BUNDLE WAS…
- 30 Oct 2004
Skin, dented
C-CHECK- RT IB FLAP LOWER SURFACE IS DENTED 11.5 INCHES FROM T/E AND 19.25 INCHES FROM IB FAIRING SEAL. REMOVED DAMAGED SECTION. INSTALLED REPAIR DOUBLER IAW…
- 30 Oct 2004
Skin, dented
C-CHECK- RT IB FLAP LOWER SURFACE IS DENTED 24 INCHES FROM THE T/E AND 17.5 INCHES FROM IB FAIRING SEAL. REMOVED DAMAGED SECTION. INSTALLED REPAIR DOUBLER IAW…
- 30 Oct 2004
Skin, delaminated
C-CHECK- RT IB FLAP VANE HAS DELAMINATION ON LOWER SURFACE. REMOVED DAMAGED SECTION, AND INSTALLED REPAIR FILLER AND DOUBLER IAW SRM.
- 30 Oct 2004
Skin, chafed
C-CHECK- LT WING L/E SURFACE HAS 7 CHAFED AREAS 5 INCHES FROM L/E AND I/B OF NR 5 L/E SLAT TRACK. REMOVED DAMAGED AREAS, THEN HFEC TREATED, PRIMED AND…
- 30 Oct 2004
Diverter, cracked
C-CHECK- RT ACM(AIR CYCLE MOTOR) DIVERTER IS CHAFED AND CRACKED. REMOVED DAMAGE, WELDED IN FILLER REPAIR IAW EA.
- 30 Oct 2004
Retainer, cracked
C-CHECK-HEAT EXCHANGER RAM AIR (Y) DUCT HAS BROKEN RETAINER ON LT SIDE. REMOVED DAMAGE, WELDED IN REPAIR TAB IAW EA.
- 30 Oct 2004
Floor Panel, delaminated
C-CHECK-MAIN CABIN FLOOR PANEL IS DELAMINATED AT CORNER. REPLACED FLOOR PANEL IAW SRM.(K)
- 30 Oct 2004
Frame, chafed
C-CHECK - AFT ACCESSORY COMPARTMENT FRAME CHAFED AT LONGERON 20R. REMOVED DAMAGED SECTION AND INSTALLED REPAIR ANGLE IAW SRM.(K)
- 28 Oct 2004
Battery Pack, discharged
OKC C-CHECK, OVERWING EMERGENCY EVACUATION LIGHTS INOPERATIVE. REPLACED ASSOCIATED POWER SUPPLY (BATTERY PACK). LIGHTS THEN OPERATED PROPERLY.(K)
- 1 Aug 2004
Handle, malfunctioned
LAS - POST FLIGHT INSPECTION, FOUND AFT SERVICE L2 DOOR COULD NOT BE OPENED FROM INSIDE. REPLACED DOOR HANDLE AND RETAINING PIN, BOLT P/N 2705574. DOOR THEN…
- 13 May 2004
Linkage, out of adjust
ANC - DURING PREFLIGHT CHECK, FOUND LEFT CAPTAINS SLIDING CLEARVIEW WINDOW WOULD NOT OPEN. ADJUSTED SLIDING MECHANISM IN TRACK. WINDOW THEN OPERATED PROPERLY.…
- 7 May 2004
Linkage, disconnected
ANC - DURING PREFLIGHT CHECK, FOUND LEFT CAPTAINS SLIDING CLEARVIEW WINDOW WOULD NOT OPEN. RECONNECTED LINKAGE. WINDOW THEN OPERATED PROPERLY. (M)
- 4 Nov 2003
Rod, out of position
LAX PREFLIGHT CHECK, LEFT CAPTAINS SLIDING CLEARVIEW WINDOW WOULD NOT OPEN. REPOSITIONED ACTUATING ROD GUIDE PIN. WINDOW THEN OPERATED PROPERLY. (M)
- 15 Oct 2003
Vane, punctured
OKC DURING 15K CHECK, FOUND RIGHT WING INBOARD FLAP VANE, FOREFLAP, IS PUNCTURED. INSTALLED DOUBLER PER SRM 51-70-2 AND EA 5750-01876. (M)
- 15 Oct 2003
Skin, corroded
OKC - DURING 15K CHECK, FOUND FUSELAGE SKIN CORRODED AT STATION 769 TO 788 UNDER FAIRING RUB STRIP AND AROUND FASTENER HOLES. INSTALLED DOUBLER, FILLERS,…
- 15 Oct 2003
Floorboard, cracked
OKC - DURING 15K CHECK, FOUND PASSENGER CABIN FLOORBOARD CRACKED AT FS 889-927. REPLACED FLOORBOARD PER SRM 53-05. (M)
- 15 Oct 2003
Frame, cracked
OKC - DURING 15K CHECK, FRAME IS CRACKED IN AFT CARGO BAY AT FS 1231. REPLACED DAMAGED SECTION AND SPLICED IN NEW SECTION PER SRM 53-05. (M)
- 15 Oct 2003
Skin, dented
OKC - DURING 15K CHECK, FUSELAGE SKIN DENTED AT FS 327-350. INSTALLED CLASS 1 REPAIR PER SRM 53-04. (M)
- 11 Oct 2003
Floorboard, debonded
FOUND DURING 15K CHECK, CABIN FLOORBOARD HAS LARGE SOFT, DEBONDED, AREA FROM FS 1117 TO 1174. REPLACED FLOORBOARD PER SRM 53-05. (M)
- 11 Oct 2003
Floorboard, corroded
FOUND DURING 15K CHECK, CABIN FLOORBOARD HAS SEVERAL CORRODED INSERTS AND LARGE TORN AREA FROM FS 1155 TO 1250. REPLACED FLOORBOARD PER SRM 53-05. (M)
- 11 Oct 2003
Skin, cracked
FOUND DURING 15K CHECK, LT ENGINE UPPER COWL IS CRACKED. REPAIRED PER EA 7110-01208 AND SRM 54-06. (M)
- 11 Oct 2003
Skin, corroded
FOUND DURING 15K CEHCK, FUSELAGE SKIN CORRODED AT FS 769-788, BETWEEN LONGERON 30 AND 29R UNDER FAIRING RUB STRIP AND AROUND FASTENER HOLES. REPAIRED PER EA…
- 11 Oct 2003
Beam, corroded
FOUND DURING 15K CHECK, AFT CARGO BAY DOOR BEAM IS CORRODED IN SEVERAL PLACES. REPLACED DOOR BEAM PER SRM 51-30-5. (M)
- 11 Oct 2003
Floorboard, gouged
DURING 15K C-CHECK, FOUND CABIN FLOOR PANEL HAS SEVERAL GOUGES BETWEEN FS 1117 AND 1174. REPLACED DAMAGED FLOOR PANEL PER SRM 53-05. (M)
- 7 Oct 2003
Structure, cracked
FOUND SUB FLOORING IS CRACK AT FS 200. REPLACED DAMAGED SUB-FLOORING SECTION PER SRM 51-70-4. (M)
- 7 Oct 2003
Floorboard, torn
FOUND FLOORBOARD FIBERGLASS CLOTH TORN FROM UPPER SURFACE AT FS 1079-1117. REPLACED FLOORBOARD PER SRM 53-03. (M)
- 7 Oct 2003
Floorboard, corroded
FOUND DURING 15K CHECK, FLIGHT DECK FLOORBOARD DELAMINATED AND CORRODED AT FS 125-160. REPLACED FLOORBOARD PER SRM 53-05. (M)
- 7 Oct 2003
Floor Support, corroded
FOUND DURING 15K CHECK, FLOOR SUPPORT CORRODED AT FS 1098-1193. REPLACED FLOOR TRACK PER SRM 51-30-1, 51-10-2, 51-10-4, AND 51-10-3. (M)
- 7 Oct 2003
Floor Panel, cracked
FOUND DURING 15K CHECK, FLOOR PANEL HAS MULTIPLE CRACKS AND PUNCTURES ON BOTTOM SURFACE AT FS 796-826. REPLACED FLOOR PANEL PER SRM 53-05. (M)
- 7 Oct 2003
Floor Panel, debonded
FOUND DURING 15K CHECK, FLOOR PANEL DISBONDED AT EDGE AT FS 769-826. REPLACED FLOOR PANEL PER SRM 53-05. (M)
- 7 Oct 2003
Seat Track, corroded
OKC - FOUND 15K CHECK, CABIN SEAT TRACK IS CORRODED AT FS 1098-1217. REPLACED SEAT TRACK PER SRM 53-05. (M)
- 7 Oct 2003
Floorboard, corroded
FOUND DURING 15K CHECK, CABIN FLOORBOARD HAS CORRODED AND SOME MISSING INSERTS AT FS 160-200. REPLACED FLOORBOARD PER SRM 53-05. (M0
- 7 Oct 2003
Floorboard, corroded
FOUND DURING 15K CHECK, FLOORBOARD HAS CORRODED AND SOME MISSING INSERTS AT FS 160-200. REPLACED FLOORBOARD PER SRM 53-05. (M)
- 7 Oct 2003
Floorboard, corroded
FOUND DURING 15K CHECK, FLIGHT DECK HAS CORRODED FLOORBOARD INSERTS AT FS 150-160. REPLACED FLOORBOARD PER SRM 53-05. (M)
- 7 Oct 2003
Floorboard, debonded
FOUND DURING 15K CHECK, CABIN FLOOR PANEL IS DISBONDING AROUND INSERTS AT FS 190-256. REPLACED FLOORBOARD [ER SRM 53-05. (M)
- 7 Oct 2003
Floorboard, corroded
FOUND DURING 15K CHECK, CABIN FLOOR PANEL IS CORRODED AROUND INSERTS AT FS 160-190. REPLACED FLOORBOARD PER SRM 53-05. (M)
- 7 Oct 2003
Floorboard, corroded
FOUND DURING 15K CHECK, CABIN FLOORBOARD JUST INSIDE L1 ENTRY IS CORRODED AROUND INSERTS AT FS 148-196. REPLACED FLOORBOARD PER SRM 53-05. (M)
- 7 Oct 2003
Floorboard, damaged
FOUND DURING 15K CHECK, CABIN FLOORBOARD HAS SEVERAL WATER DAMAGED INSERTS AT FS 218-256. REPLACED FLOORBOARD IAW SRM 53-05. (M)
- 7 Oct 2003
Floorboard, delaminated
FOUND DURING 15K CHECK, CABIN FLOOR PANEL IS DELAMINATED IN TWO PLACES BETWEEN FS 465-541. REPLACED FLOORBOARD IAW SRM 53-05. (M)
- 7 Oct 2003
Floorboard, debonded
DURING 15K CHECK FOUND CABIN FLOOR PANEL IS DISBODED AT CORNER AND CREASED THROUGH MIDDLE AT FS 465-522. REPLACED FLOORBOARD PER SRM 53-05. (M)
- 7 Oct 2003
Floorboard, delaminated
OKC - FOUND DURING 15K CHECK, CABIN FLOOR PANEL IS DELAMINATED AT TWO LOCATIONS BETWEEN FS 541 AND 617. REPLACED FLOORBOARD PER SRM 53-05. (M)
- 7 Oct 2003
Floorboard, corroded
FOUND DURING 15K CHECK, CABIN FLOORBOARD IS CORRODED BETWEEN FS 598-636. REPLACED FLOORBOARD PER SRM 53-24-0. (M)
- 7 Oct 2003
Floorboard, damaged
FOUND DURING 15K CHECK, CABIN FLOOR EDGES HAVE BEEN WATER DAMAGED BETWEEN FS 1003 AND 1074. REPLACED FLOORBOARD PER SRM 53-24-0. (M)
- 7 Oct 2003
Floorboard, broken
FOUND DURING 15K CHECK, CABIN FLOOR INSERTS ARE DAMGED, SOME BROKEN AND SOME PULLED, BETWEEN FS 1117 AND 1174. REPLACED FLOORBOARD PER SRM 53-05. (M)
- 23 Sep 2003
Seat Track, corroded
OKC - DURING 15K CHECK, FOUND SEAT TRACK IS CORRODED FROM FS 1098 TO 1193. REPLACED TRACK IAW SRM 51-30-1, 10-2, 10-4, AND 10-3. (M)
- 9 Mar 2003
Light, malfunctioned
OAK - DURING LINE CHECK, FOUND PORTABLE EMERGENCY LIGHT AT FORWARD ENTRY DOOR WOULD NOT EXTINGUISH WITH SWITCH OFF. REPLACED LIGHT ASSEMBLY. LIGHT THEN…
- 30 Jan 2003
Light, malfunctioned
PDX - DURING LINE CHECK, FOUND PORTABLE EMERGENCY LIGHT AT FORWARD ENTRY DOOR ILLUMINATED WITH SWITCH TURNED OFF. REPLACED LIGHT ASSEMBLY, INCLUDING BATTERY…
- 20 Dec 2002
Lanyard, disconnected
SJC - DURING PREFLIGHT CHECK, R-1 DOOR EMERGENCY SLIDE LANYARD WAS FOUND TO BE DETACHED. REATTACHED LANYARD. (M)
- 23 Oct 2002
Harness, failed
DURING C CHECK, FORWARD SERVICE DOOR EMERGENCY SLIDE HARNESS FAILED SYSTEM CHECK. REPLACED EMERGENCY SLIDE. SYSTEM CHECKED, OK.
- 19 Oct 2002
Wire, disconnected
DURING LINE CHECK, FOUND EMERGENCY TRACK LIGHT INOPERATIVE AT ROW 21. REPLACED CONNECTOR WIRE. LIGHTS THEN OPERATED PROPERLY. (M)
- 17 Oct 2002
Door Frame, corroded
OAK - FOUND C-CHECK, AFT CARGO BAY DOOR JAMB BEAM IS CORRODED IN SEVERAL PLACES. REMOVED CORRODED AREA, ADDED FILLER, AND INSTALLED DOUBLER PER EA 5310-02122.…
- 21 Sep 2002
Mechanism, out of adjust
SEA - FOUND L1 DOOR DIFFICULT TO OPEN. ADJUSTED DOOR MECHANISM. DOOR THEN OPENED NORMALLY. (M)
- 26 Aug 2002
Module, disconnected
PDX - DURING PREFLIGHT CHECK, FOUND EMERGENCY TRACK LIGHTS WERE FOUND TO BE INOPERATIVE AT ROW 7. RECONNECTED DISCONNECTED LIGHT MODULE. LIGHTS THEN OPERATED…
- 25 Aug 2002
Light, inoperative
PDX - DURING LINE CHECK, FOUND PORTABLE EMERGENCY LIGHT ON AND WILL NOT TURN OFF. REPLACED PORTABLE LIGHT ASSEMBLY. LIGHT THEN OPERATED NORMALLY. (M)
- 22 Aug 2002
Module, inoperative
SEA - DURING LINE CHECK, NUMEROUS EMERGENCY TRACK LIGHTS WERE FOUND TO BE INOPERATIVE IN FORWARD CABIN. REPLACED INOPERATIVE MODULES. LIGHTS THEN OPERATED…
- 21 Aug 2002
Module, inoperative
SEA - DURING PREFLIGHT CHECK, FOUND EMERGENCY TRACK LIGHTING INOPERATIVE IN 1ST CLASS CABIN. REPLACED A LIGHT MODULE. LIGHTS THEN OPERATED PROPERLY. (M)
- 18 Aug 2002
Light, inoperative
LAX - DURING PREFLIGHT CHECK, FOUND EMERGENCY TRACK LIGHTS INOPERATIVE IN VARIOUS LOCATIONS THROUGH OUT CABIN. RECONNECTED/REPAIRED LIGHTS. LIGHT THEN…
- 27 Jul 2002
Plug, out of position
PDX - DURING LINE MAINTENANCE CHECK, EMERGENCY TRACK LIGHTING WAS INOPERATIVE ROWS 6-9. REINSTALLED PLUG IN TRACK LIGHTING MODULE. LIGHTS THEN OPERATED…
- 23 Jul 2002
Wire, disconnected
PDX - DURING LINE CHECK, EMERGENCY TRACK LIGHTING WAS INOPERATIVE FROM ROW 6 TO 9. RECONNECTED WIRING TO LIGHT MODULE CONNECTOR. LIGHTS THEN OPERATED…
- 15 Jul 2002
Lanyard, disconnected
PHX - DURING PRE-FLIGHT CHECK, THE AFT SERVICE DOOR EMERGENCY SLIDE LANYARD WAS FOUND TO BE DETACHED. REATTACHED LANYARD. (M)
- 29 May 2002
Light, inoperative
LAX - DURING LINE CHECK, FOUND PORTABLE EMERGENCY LIGHT TO BE INOPERATIVE. REPLACED PORTABLE LIGHT. OP TESTED OK. (M)
- 7 Mar 2002
Pin, missing
PDX - DURING PREFLIGHT CHECK, THE CAPTAINS SLIDING CLEARVIEW WINDOW COULD NOT BE OPENED. REINSTALLED PIN IN WINDOW HINGE LINKAGE. WINDOW THEN OPERATED…
- 4 Mar 2002
Battery, discharged
OAK - DURING LINE CHECK, FOUND PORTABLE EMERGENCY LIGHT TO BE INOPERATIVE. REPLACED PORTABLE LIGHT. OP TESTED OK. (M)
- 23 Feb 2002
Lanyard, disconnected
SEA - FORWARD GALLEY DOOR LANYARD BETWEEN GIRT BAR AND SLIDE COVER BECAME DISCONNECTED. REATTACHED LANYARD. (M)
- 23 Sep 2001
Lanyard, detached
SEA - DURING PRE-FLIGHT CHECK, R-1 DOOR EMERGENCY SLIDE GIRT BAR TO LATCH LANYARD WAS FOUND DETACHED. REATTACHED LANYARD. (M)
- 23 Sep 2001
Module, inoperative
LAX - DURING PREFLIGHT CHECK, DETERMINED EMERGENCY TRACK LIGHTING TO BE INOPERATIVE AT ROW 30. REPLACED LIGHT MODULE SOCKET AND RELAMPED. LIGHTS THEN OPERATED…
- 21 Aug 2001
Module, disconnected
ANC - DURING PREFLIGHT CHECK, EMERGENCY FLOOR TRACK LIGHTING WAS INOPERATIVE IN 1ST CLASS CABIN. RECONNECTED LOOSE LIGHT MODULES. LIGHT THEN OPERATED…
- 12 Aug 2001
Coalescer Bag, dirty
ZIH - DURING CLIMB AT 10K FEET ALTITUDE, BURNING RUBBER/ELECTRICAL FIRE SMELL WAS DETECTED IN VICINITY OF ROW 15. REMOVED OVERHEAD PANELS AT ROWS 13-17 AND…
- 17 Jun 2001
Lanyard, disconnected
SEA - DURING PREFLIGHT CHECK, R1 DOOR EMERGENCY SLIDE LANYARD WAS FOUND TO BE DETACHED FROM DOOR. REATTACHED LANYARD BETWEEN GIRT BAR AND DOOR SLIDE COVER. (M)
- 11 Jun 2001
Door, out of rig
JUN - AFTER TAXI UP TO GATE, L1 DOOR FORWARD LEFT CREW/PAX DOOR WAS FOUND TO BE DIFFICULT TO OPEN. RIGGED L1 DOOR. THE DOOR THEN OPERATED PROPERLY. (M)
- 7 Jun 2001
Light, inoperative
OAK - DURING C-CHECK, THE LEFT FORWARD ENTRY PORTABLE EMERGENCY EXIT LIGHT WAS FOUND TO BE INOPERATIVE. REPLACED THE PORTABLE EMERGENCY LIGHT ASSEMBLY WITH A…
- 5 Jun 2001
Slide, failed
OAK - DURING C-CHECK, AFT REAR DOOR EMERGENCY SLIDE HARNESS FAILED SYSTEM CHECK. REPLACED EMERGENCY SLIDE PER T/C 24653002. SYSTEM CHECKED OK. (M)
- 5 Jun 2001
Skin, damaged
SEA - DURING LINE CHECK, FOUND RIGHT LOWER WING DAMAGE AT XRS 509.5 FROM FRONT TO REAR REAR. INITIATED PERIODIC INSPECTION PER EA 5720-01193, WITH FINAL…
- 16 May 2001
Light, inoperative
ANC - DURING LINE CHECK, FOUND SOME EMERGENCY FLOOR TRACK LIGHTS INOPERATIVE THROUGHOUT CABIN. RESEATED TRACK LIGHTING MODULES. LIGHTS THEN OPERATED PROPERLY.…
- 15 May 2001
Light, inoperative
PDX - DURING SERVICE CHECK, FOUND SEVERAL EMERGENCY FLOOR TRACK LIGHTS INOPERATIVE IN 1ST CLASS CABIN ON RIGHT SIDE. RESEATED TRACK LIGHTING MODULES. LIGHTS…
- 7 May 2001
Light, inoperative
PDX - DURING LINE CHECK, FOUND EMERGENCY FLOOR TRACK LIGHTING INOPERATIVE AT ROWS 6, 7 AND 8. REPLACED TRACK LIGHTING BASE AND COVER IAW EA 3350-01014. LIGHTS…
- 21 Apr 2001
Light, inoperative
SEA - DURING LINE CHECK, FOUND EMERGENCY FLOOR TRACK LIGHTING INOPERATIVE AT ROW 6-7. REPLACED LAMP MODULE. LIGHTS THEN OPERATED PROPERLY. (M)
- 13 Mar 2001
Light, inoperative
SEA - DURING SERVICE CHECK, FORWARD CABIN PORTABLE EMERGENCY LIGHT WAS DETERMINED TO BE INOPERATIVE. REPLACED LIGHT ASSEMBLY. LIGHT THEN OPERATED PROPERLY. (M)
- 10 Mar 2001
Lanyard, disconnected
SEA - DURING PRE-FLIGHT CHECK, R-1 DOOR EMERGENCY SLIDE LANYARD WAS FOUND TO BE PULLED OUT OF PLACE. REINSTALLED LANYARD PROPERLY. (M)
- 11 Feb 2001
Lanyard, disconnected
ANC - DURING PREFLIGHT CHECK, L2 DOOR EMERGENCY SLIDE LANYARD WAS FOUND TO BE DETACHED. REATTACHED LANYARD BETWEEN GIRT BAR AND SLIDE COVER. (M)
- 11 May 2000
Wire, disconnected
SEA - PRIOR TO DEPARTURE, THE EMERGENCY EXIT FLOOR TRACK LIGHTS AT ROWS 6 AND 7 WERE FOUND INOPERATIVE. RECONNECTED LOOSE WIRING AND LIGHTS OPERATED NORMALLY.…
- 6 Mar 2000
Battery Pack, will not test
PHX - DURING 30K CHECK, THE OVERWING EMERGENCY EXIT LIGHTS FAILED THE LUMINOSITY CHECK. REPLACED THE BATTERY PACK AND THE LIGHTS OPERATED NORMALLY. (X)
- 6 Mar 2000
Skin, corroded
PHX - DURING 30K CHECK, THE FUSELAGE AT FS 826 WAS FOUND CORRODED ON THE UNDERWING BELLY SKIN, OUTER SURFACE. REMOVED CORROSION AND REPAIRED PER EA 5310-01803…
- 6 Mar 2000
Frame, misrepaired
PHX - DURING 30K CHECK, WHILE ACCOMPLISHING FRAME REPAIR OF A DENT AT FS 731, LONGERON 24L PER PRELIMINARY EA 1590-EG-0005, ADDITIONAL DAMAGE IN THE FORM OF…
- 6 Mar 2000
Skin, chafed
PHX - DURING 30K CHECK, THE CENTER CARGO DOOR WAS FOUND CHAFED ON THE DOOR INNER PAN AT BOTH HINGE ARM CUTOUT LOCATIONS. REPAIRED PER EA 5230-01105 AND EA…
- 6 Mar 2000
Pan, gouged
PHX - DURING 30K CHECK, THE CENTER CARGO DOOR WAS FOUND GOUGED ON THE INNER PAN OF THE DOOR ON THE AFT SIDE. REPAIRED PER EA 5230-01109 AND EA 10-5230-0316. (M)
- 6 Mar 2000
Spar Cap, damaged
PHX - DURING 30K CHECK, FOUND AN ELONGATED LEADING EDGE CAP ATTACH FASTENER HOLE IN THE LEFT HORIZONTAL STABILIZER FORWARD LOWER SPAR CAP FLANGE AT STATION…
- 29 Feb 2000
Floorbeam, corroded
PHX - DURING 30K CHECK, THE RIGHT CABIN FLOOR CUSP BEAM WAS FOUND CORRODED BETWEEN FS 484 AND 503. REPAIRED PER SRM 53-10-3. (M)
- 29 Feb 2000
Longeron, corroded
PHX - DURING 30K CHECK, THE AFT CARGO COMPARTMENT FS 1231, BEAM LONGERON 29R, WAS FOUND CORRODED AT THE RADIUS OF THE LOWER HORIZONTAL LEG. REPAIRED PER SRM…
- 27 Feb 2000
Slide, failed
PHX - DURING 30K CHECK, THE TAILCONE EXIT EMERGENCY EVACUATION SLIDE FAILED THE EMERGENCY LIGHT AMP TEST. REPLACED THE TAILCONE EXIT EMERGENCY EVACUATION…
- 20 Feb 2000
Shear Tie, corroded
PHX - DURING SCHEDULED 30K CHECK, THE AFT CARGO COMPARTMENT STATION 1287 BETWEEN LONGERON 29L TO 30L SHEAR TIE WAS FOUND TO BE CORRODED. REPAIRED PER SRM. (M)
- 18 Feb 2000
Floor Support, corroded
PHX - DURING 30K CHECK, THE MAIN CABIN FLOOR SUPPORT AT FS 180, RBL 25 WAS FOUND CORRODED. REPAIRED PER SRM 53-14-1, FIG 11. (M)
- 18 Feb 2000
Web, corroded
PHX - DURING 30K CHECK, THE SUB FLOOR WEB AT FS 148-156, RBL 53 WAS FOUND CORRODED. REPAIRED PER SRM 53-01. (M)
- 18 Feb 2000
Fitting, corroded
PHX - DURING 30K CHECK, THE MAIN CABIN FLOOR SUPPORT MOUNT FITTING AT FS 160, RBL 10 WAS FOUND CORRODED. REPAIRED PER SRM 51-30. (M)
- 18 Feb 2000
Floor Support, corroded
PHX - DURING 30K CHECK, THE MAIN CABIN FLOOR SUPPORT AT LBL 6, FS 160-200 WAS FOUND CORRODED. REPAIRED PER SRM 51-30. (M)
- 18 Feb 2000
Floor Support, corroded
PHX - DURING 30K CHECK, THE FLOOR SUPPORT AT FS 160-200, RBL 6 WAS FOUND CORRODED. REPAIRED PER SRM 53-14-1. (M)
- 18 Feb 2000
Floor Support, corroded
PHX - DURING 30K CHECK, THE MAIN CABIN FLOOR SUPPORT AT L1 DOOR, FS 160-200, LBL 45 WAS FOUND CORRODED. REPAIRED PER SRM 51-30. (M)
- 18 Feb 2000
Floor Support, corroded
PHX - DURING 30K CHECK, THE MAIN CABIN FLOOR SUPPORT AT L1 DOOR, FS 160-200, LBL 50 WAS FOUND CORRODED. REPAIRED PER SRM 51-30. (M)
- 18 Feb 2000
Floor Support, corroded
PHX - DURING 30K CHECK, THE MAIN CABIN FLOOR SUPPORT AT FS 160-200, RBL 50 WAS FOUND CORRODED. REPAIRED PER SRM 51-30-2. (M)
- 18 Feb 2000
Web, corroded
PHX - DURING 30 K CHECK, THE MAIN CABIN FLOOR WEB AT FS 160-200, RBL 56 T0 LBL 56 WAS FOUND CORRODED. REPAIRED PER SRM 51-30. (M)
- 18 Feb 2000
Floor Support, corroded
PHX - DURING 30K CHECK, THE MAIN CABIN FLOOR SUPPORT AT FS 200, BL 0 WAS FOUND CORRODED. REPAIRED PER SRM 53-14-1, FIG 11. (M)
- 18 Feb 2000
Floor Support, corroded
PHX - DURING 30K CHECK, THE MAIN CABIN FLOOR SUPPORT AT FS 200, RBL 9 TO 43 WAS FOUND CORRODED. REPAIRED PER SRM 51-30. (M)
- 18 Feb 2000
Floor Support, corroded
PHX - DURING 30K CHECK, THE MAIN CABIN FLOOR SUPPORT AT FS 200, LBL 13 WAS FOUND CORRODED. REPAIRED PER SRM 51-30. (M)
- 18 Feb 2000
Floor Support, corroded
PHX - DURING 30K CHECK, THE MAIN CABIN FLOOR SUPPORT AT FS 200, RBL 45-55 WAS FOUND CORRODED. REPAIRED PER SRM 51-30. (M)
- 18 Feb 2000
Floor Support, corroded
PHX - DURING 30K CHECK, THE MAIN CABIN FLOOR SUPPORT AT FS 200, LBL 56 WAS FOUND CORRODED. REPAIRED PER SRM 51-30. (M)
- 18 Feb 2000
Channel, corroded
PHX - DURING 30K CHECK, THE MAIN CABIN FLOOR U-CHANNEL FOR THE GALLEY ATTACH FITTING WAS FOUND CORRODED AT FS 200-218, RBL 55. REPAIRED PER SRM 51-30. (M)
- 18 Feb 2000
Floor Support, corroded
PHX - DURING 30K CHECK, THE MAIN CABIN FLOORBOARD SUPPORT AT STATION 200, RBL 58 WAS FOUND CORRODED. REPAIRED PER SRM 51-30. (M)
- 18 Feb 2000
Web, corroded
PHX - DURING 30K CHECK, THE MAIN CABIN CUSP BEAM WEB AT FS 446 AND 465, RBL 56 WAS FOUND CORRODED. REPAIRED PER SRM 53-01, FIG 4. (M)
- 18 Feb 2000
Beam, corroded
PHX - DURING 30K CHECK, THE MAIN CABIN CUSP BEAM WEB AT FS 448, RBL 56 WAS FOUND CORRODED. REPAIRED PER SRM 53-01. (M)
- 18 Feb 2000
Floorbeam, corroded
PHX - DURING 30K CHECK, THE MAIN CABIN FLOOR CUSP BEAM WEB BETWEEN STATION 503 AND 579, RBL 56 WAS FOUND CORRODED. REPAIRED PER SRM 51-30-2. (M)
- 18 Feb 2000
Floorbeam, corroded
PHX - DURING 30K CHECK, THE MAIN CABIN FLOOR CUSP BEAM WEB BETWEEN STATION 588 AND 617, RBL 56 WAS FOUND CORRODED. REPAIRED PER SRM 53-01, FIG 4. (M)
- 18 Feb 2000
Floorbeam, corroded
PHX - DURING 30K CHECK, THE MAIN CABIN CUSP BEAM WEB AT STATION 636 TO 655, LBL 56 WAS FOUND CORRODED. REPAIRED PER SRM 53-01 FIG 4. (M)
- 18 Feb 2000
Floorbeam, corroded
PHX - DURING 30K CHECK, THE MAIN CABIN CUSP BEAM WEB AT FS 674 TO 693, LBL 56 WAS FOUND CORRODED. REPAIRED PER SRM 53-01 FIG 4. (M)
- 18 Feb 2000
Floorbeam, corroded
PHX - DURING 30K CHECK, THE MAIN CABIN FLOOR CUSP BEAM WEB AT FS 1041, RBL 56 WAS FOUND CORRODED. REMOVED CORROSION AND REPAIRED PER SRM 53-01, FIG 4. (M)
- 18 Feb 2000
Floor Support, corroded
PHX - DURING 30K CHECK, THE AFT CARGO COMPARTMENT FLOORBOARD SUPPORT AT FS 1155, LONGERON 28L TO 29R WAS FOUND CORRODED. REMOVED CORROSION AND REPAIRED PER…
- 18 Feb 2000
Floorbeam, corroded
PHX - DURNG 30K CHECK, THE LEFT MAIN CABIN FLOOR CUSP BEAM WEB AT FS 1174 TO 1193, LBL 56 WAS FOUND CORRODED. REMOVED CORROSION AND REPAIRED PER SRM 53-01,…
- 18 Feb 2000
Floorbeam, corroded
PHX - DURING 30K CHECK, THE LEFT MAIN CABIN FLOOR CUSP BEAM WEB AT FS 1231 TO 1250, LBL 56 WAS FOUND CORRODED. REMOVED CORROSION AND REPAIRED PER SRM 53-14-3,…
- 18 Feb 2000
Web, corroded
PHX - DURING 30K CHECK, THE WEB IN THE AFT CARGO COMPARTMENT WAS FOUND CORRODED ON THE UPPER FLANGE AT FS 1307 AND 1320 BETWEEN LONGERON 27L AND 28L. REMOVED…
- 18 Feb 2000
Web, corroded
PHX - DURING 30K CHECK, THE WEB IN THE AFT CARGO COMPARTMENT WAS FOUND CORRODED ON THE UPPER FLANGE AROUND NUTPLATE HOLES AT FS 1307 AND 1320 BETWEEN LONGERON…
- 18 Feb 2000
Web, corroded
PHX - DURING 30K CHECK, THE CUSP MEMBRANE AT FS 1142, LBL 58 ON THE TOP SURFACE WAS FOUND CORRODED. REMOVED CORROSION AND REPAIRED PER SRM 53-01. (M)
- 18 Feb 2000
Seat Track, corroded
PHX - DURING 30K CHECK, THE RIGHT MAIN CABIN SEAT TRACK AT FS 400 TO 474, RBL 22 WAS FOUND CORRODED. REMOVED CORROSION AND REPAIRED PER SRM 53-05, FIG 4B. (M)
- 15 Feb 2000
Slide, will not test
PHX - DURING 30K CHECK, THE L2 DOOR EMERGENCY EVACUATION SLIDE FAILED THE EMERGENCY LIGHT AMP TEST. REPLACED THE L2 DOOR EMERGENCY EVACUATION SLIDE ASSEMBLY.…
- 22 Dec 1999
Light, inoperative
LAX - DURING MAINTENANCE CHECK, THE FORWARD PORTABLE EMERGENCY LIGHT WAS FOUND INOPERATIVE. REPLACED THE LIGHT ASSEMBLY AND OPERATED NORMALLY. (M)
- 13 Nov 1999
Connector, disconnected
SEA DURING MAINTENANCE CHECK, THE EMERGENCY EXIT FLOOR TRACK LIGHTS AT ROWS 13 THROUGH 16 WERE FOUND INOPERATIVE. RECONNECTED CONNECTOR TO LIGHT ASSEMBLY IN…
- 13 Jun 1999
Connector, loose
PHX - PRIOR TO DEPARTURE OF FLT 721 - CREW REPORTED THE EMERGENCY FLOOR TRACK RED LIGHTS IN THE FORWARD CABIN WERE INOPERATIVE. SECURED LOOSE CONNECTOR IN…
- 4 Jun 1999
Batteries, discharged
SEA - DURING MAINTENANCE CHECK, THE OVERHEAD EMERGENCY LIGHTS BETWEEN THE AFT LAVATORIES WERE FOUND INOPERATIVE. REPLACED THE BATTERIES IN THE POWER SUPPLY…
- 18 Apr 1999
Window, out of adjust
SEA - AFTER ARRIVAL OF FLIGHT 472, CREW REPORTED THE FLIGHT COMPARTMENT RIGHT SLIDING WINDOW WOULD NOT OPEN. ADJUSTED UPPER LOCK BAR LINKAGE AND OPERATED…
- 26 Feb 1999
Hinge Pin, loose
PDX - AFTER ARRIVAL OF FLT 317, CREW REPORTED THE FLIGHT COMPARTMENT LEFT SLIDING WINDOW OPERATING MECHANISM DETACHED. FOUND WINDOW LOWER AFT HINGE PIN…
- 10 Feb 1999
Power Supply, defective
SEA - DURING MAINTENANCE CHECK, THE EXTERIOR OVERWING EMERGENCY LIGHTS WOULD NOT EXTINGUISH. REPLACED THE POWER SUPPLY AND OPERATED NORMALLY. (M)
- 19 Jan 1999
Power Supply, inoperative
PDX - DURING MAINTENANCE CHECK, THE EXTERIOR OVERWING EMERGENCY LIGHTS WERE FOUND INOPERATIVE. REPLACED THE POWER SUPPLY AND OPERATED NORMALLY. (M)
- 4 Jan 1999
Window, out of adjust
SEA - PRIOR TO DEPARTURE OF FLIGHT 231, CREW REPORTED THE FLIGHT COMPARTMENT LEFT SLIDING WINDOW WOULD NOT OPEN. ADJUSTED WINDOW MECHANISM AND OPERATED…
- 12 Dec 1998
Wire, disconnected
SEA - PRIOR TO DEPARTURE OF FLIGHT 366, CREW REPORTED THE EMERGENCY FLOOR TRACK LIGHTS FROM ROW 8 FORWARD WERE INOPERATIVE. RECONNECTED WIRING IN FLOOR TRACK…
- 29 Nov 1998
Window, out of adjust
SEA - PRIOR TO DEPARTURE OF FLIGHT 451, CREW REPORTED THE FLIGHT COMPARTMENT LEFT SLIDING WINDOW WOULD NOT OPEN. ADJUSTED WINDOW UPPER GUIDE MECHANISM AND…
- 3 Oct 1998
Lock Mech, binding
FAI - AFTER ARRIVAL OF FLIGHT 97, CREW REPORTED THE FLIGHT COMPARTMENT RIGHT SLIDING WINDOW WOULD NOT OPEN. LUBRICATED WINDOW UPPER LOCK MECHANISM AND…
- 3 Oct 1998
Lock, binding
FAI - PRIOR TO DEPARTURE OF FLIGHT 80, CREW REPORTED THE FLIGHT COMPARTMENT RIGHT SLIDING WINDOW WOULD NOT OPEN. FREED WINDOW UPPER LOCK MECHANISM AND…
- 16 Sep 1998
Slide, malfunctioned
OAK - DURING C-CHECK, THE L2 DOOR EMERGENCY EVACUATION SLIDE FAILED THE EMERGENCY LIGHT AMP TEST. REPLACED THE L2 DOOR EMERGENCY EVACUATION SLIDE ASSEMBLY. (M)
- 20 Aug 1998
Batteries, discharged
SEA - DURING MAINTENANCE CHECK, THE OVERHEAD EMERGENCY LIGHTS IN THE FORWARD ENTRY WERE FOUND INOPERATIVE. REPLACED THE BATTERIES IN THE POWER SUPPLY AND…
- 4 Jun 1998
Light, inoperative
SEA - DURING MAINTENANCE CHECK, THE RED EMERGENCY FLOOR TRACK LIGHT AT THE AFT GALLEY WAS FOUND INOPERATIVE. REPLACED LAMP MODULE AT AFT GALLEY AND OPERATED…
- 4 Jun 1998
Light, inoperative
SEA - DURING MAINTENANCE CHECK, THE OVERHEAD EMERGENCY LIGHTS IN THE CATWALK AREA WERE FOUND DIM. REPLACED SECOND FROM FORWARD LIGHT ASSEMBLY AND OPERATED…
- 17 May 1998
Bearing, worn
SEA - ARRIVAL OF FLT 88, CREW REPORTED THE L2 DOOR WOULD NOT FULLY OPEN. REPLACED THE UPPER HINGE TORQUE TUBE BEARING AND OPERATED NORMALLY. (M)
- 26 Mar 1998
Wire, defective
ONT - PRIOR TO DEPARTURE OF FLT 531, CREW REPORTED THE EMERGENCY FLOOR TRACK LIGHTS IN THE FORWARD CABIN WERE INOPERATIVE. REPAIRED WIRE IN FLOOR TRACK AND…
- 15 Feb 1998
Hold Open Hook, bent
ONT - FLT 595 - PRIOR TO DEPARTURE, CREW REPORTED THE L1 DOOR WOULD NOT CLOSE. REPLACED THE DOOR HOLD OPEN HOOK AND OPERATED NORMALLY. AIRCRAFT TT: 21,095…
- 5 Feb 1998
Light, defective
PDX - DURING MAINTENANCE CHECK, THE FORWARD PORTABLE EMERGENCY LIGHT WAS FOUND DIM. REPLACED THE LIGHT ASSEMBLY AND OPERATED NORMALLY. (M)
- 7 Nov 1997
Handle Pin, broken
SEA - AFTER ARRIVAL OF FLT 513, CREW REPORTED THE L2 DOOR HANDLE WOULD NOT CLOSE PROPERLY. REPLACED THE L2 DOOR HANDLE RETAINING PIN AND OPERATED NORMALLY. (M)
- 21 Oct 1997
Retaining Pin, broken
SEA - AFTER ARRIVAL OF FLT 191, CREW REPORTED THE L2 DOOR HANDLE WAS NOT POSITIONED CORRECTLY. REPLACED THE L2 DOOR HANDLE RETAINING PIN AND OPERATED…
- 17 Sep 1997
Inflation Bottle, high pressure
PDX - DURING MAINTENANCE CHECK, THE L1 DOOR EMERGENCY EVACUATION SLIDE INFLATION BOTTLE PRESSURE WAS FOUND HIGH. REPLACED THE L1 DOOR EMERGENCY EVACUATION…
- 26 Jul 1997
Wire, broken
SEA - DURING MAINTENANCE CHECK, THE EMERGENCY FLOOR TRACK LIGHTS FROM ROWS 6 TO 9 WERE FOUND INOPERATIVE. REPAIRED BROKEN WIRE IN TRACK AND OPERATED NORMALLY.…
- 15 May 1997
Light, defective
SEA - DURING MAINTENANCE CHECK, THE FORWARD PORTABLE EMERGENCY LIGHT WAS FOUND INOPERATIVE. REPLACED THE LIGHT ASSEMBLY AND OPERATED NORMALLY. (M)
- 15 May 1997
Wire, disconnected
SEA - DURING MAINTENANCE CHECK, THE EMERGENCY FLOOR TRACK LIGHTS FROM ROWS 6 TO 8 WERE FOUND INOPERATIVE. RECONNECTED WIRING IN TRACK ASSEMBLY AND OPERATED…
- 1 May 1997
Slide, failed test
OAK - DURING C-CHECK, THE L2 DOR EMERGENCY EVACUATION SLIDE EMERGENCY LIGHTS FAILED TEST. REPLACED THE L2 DOOR EMERGENCY EVACUATION SLIDE. (M)
- 1 May 1997
Slide, failed test
OAK - DURING C-CHECK, THE TAILCONE EMERGENCY EVACUATION SLIDE EMERGENCY LIGHTS FAILED TEST. REPLACED THE TAILCONE EMERGENCY EVACUATION SLIDE. (M)
- 10 Mar 1997
Light, defective
PDX - DURING MAINTENANCE CHECK, THE FORWARD PORTABLE EMERGENCY LIGHT WAS FOUND INOPERATIVE. REPLACED THE LIGHT ASSEMBLY AND OPERATED NORMALLY. (M)
- 21 Feb 1997
Wire, broken
SEA - DURING MAINTENANCE CHECK, THE EMERGENCY FLOOR TRACK LIGHTS FROM ROWS 6 TO 9 WERE FOUND INOPERATIVE. REPAIRED WIRING AT ROW 6 AND OPERATED NORMALLY. (M)
- 28 Sep 1996
Wire, disconnected
SEA - DURING MAINTENANCE CHECK, THE EMERGENCY FLOOR TRACK LIGHTS FROM ROWS 14 TO 16 WERE FOUND INOPERATIVE. RECONNECTED WIRE AT ROW 17 AND OPERATED NORMALLY.…
- 6 Sep 1996
Light, defective
SFO - DURING MAINTENANCE CHECK, THE FORWARD PORTABLE EMERGENCY LIGHT WAS FOUND INOPERATIVE. REPLACED THE LIGHT ASSEMBLY AND OPERATED NORMALLY. (M)
- 21 Aug 1996
Wire, disconnected
ANC - DURING MAINTENANCE CHECK, THE EMERGENCY FLOOR TRACK LIGHTS AT ROW 6 WERE FOUND INOPERATIVE. FOUND WIRING DISCONNECTED, RECONNECTED WIRING AND OPERATED…
- 7 Aug 1996
Wire, disconnected
SEA - PRIOR TO DEPARTURE OF FLT 203 - CREW REPORTED, THE EMERGENCY FLOOR TRACK LIGHTS IN THE FORWARD CABIN WERE INOPERATIVE. RECONNECTED WIRING AT ROW 3 AND…
- 17 Jul 1996
Track, defective
PDX - FLT 56 - EMERGENCY EXIT FLOOR TRACK LIGHTING INOPERATIVE ROWS S30 AND 32/33. RELAMPED AND INSTALLED NEW SECTION OF TRACK; LIGHTS OPERATED NORMALLY.…
- 17 Jul 1996
Lamp, defective
PDX - FLT 56 - EMERGENCY EXIT FLOOR TRACK LIGHTING INOPERATIVE ROWS S30 AND 32/33. RELAMPED AND INSTALLED NEW SECTION OF TRACK; LIGHTS OPERATED NORMALLY.…
- 6 Jul 1996
Wire, broken
LAX - DURING MAINTENANCE CHECK, THE EMERGENCY FLOOR TRACK LIGHTSFROM ROW 30 AFT WERE FOUND INOPERATIVE. REPAIRED BROKEN WIRE AT ROW 31 ANDOPERATED NORMALLY. (M)
- 1 Jun 1996
Wire, disconnected
SEA - DURING MAINTENANCE CHECK, THE EMERGENCY FLOOR TRACK LIGHTS IN THE FORWARD CABIN WERE FOUND INOPERATIVE. RECONNECTED WIRING AT ROW 2 AND OPERATED…
- 10 Mar 1996
Track Light, defective
SEA - DURING MAINTENANCE CHECK, THE FORWARD SECTION OF EMERGENCY FLOOR TRACK LIGHTS WERE FOUND INOPERATIVE. REPLACED LIGHT ASSEMBLY AT ROW 2 AND OPERATED…
- 26 Feb 1996
Wire, disconnected
SEA - DURING MAINTENANCE CHECK, THE EMERGENCY FLOOR TRACK LIGHTS FROM ROWS 25 TO 28 WERE FOUND INOPERATIVE. RECONNECTED WIRING AND OPERATED NORMALLY. (M)
- 25 Nov 1995
Light, defective
SEA - DURING MAINTENANCE CHECK, THE FORWARD PORTABLE EMERGENCY LIGHT WAS FOUND INOPERATIVE. REPLACED THE LIGHT ASSEMBLY AND OPERATED NORMALLY. (M)
- 13 Jan 1995
Eel Wiring, disconnected
LAX - FLT 255 - PRIOR TO DEPARTURE, CREW REPORTED THE EMERGENCY EXIT FLOOR TRACK LIGHTS AT THE OVERWING EXIT AREA WERE INOPERATIVE. REPAIRED BROKEN WIRING IN…