N960TW
1985 McDonnell Douglas DC-9-82(MD-82) standard FAA →
earlier registrations
2 past records
- 2020
- 1985
service difficulty reports
31 reports
- 1 Feb 2003
Wire Harness, disconnected
THE FIRST CLASS EGRESS LIGHTING WAS INOPERATIVE. RECONNECTED FEEDER CABLE.
- 1 Feb 2003
Connector, disconnected
THE EGRESS EMERGENCY EXIT LIGHT STRIP AT THE AFT GALLEY DOOR EXIT WAS INOPERATIVE. RECONNECTED CONNECTOR ON TERMINAL STRIP.
- 6 Jan 2003
Light, inoperative
AN EMERGENCY CEILING LIGHT AT ROW 11, ROW 27 TO AFT CABIN CEILING LIGHTS, AND BOTH AFT OVERWING EMERGENCY EXIT SIGNS WERE ALL INOPERATIVE. REPLACED THE LAMP…
- 6 Jan 2003
Battery Pack, discharged
AN EMERGENCY CEILING LIGHT AT ROW 11, ROW 27 TO AFT CABIN CEILING LIGHTS, AND BOTH AFT OVERWING EMERGENCY EXIT SIGNS WERE ALL INOPERATIVE. REPLACED THE LAMP…
- 11 Sep 2002
Battery, discharged
BOTH COCKPIT EMERGENCY LIGHTS AT TOP OF OVERHEAD PANEL WERE INOPERATIVE. REPLACED BATTERIES IN POWER SUPPLY B5-23.
- 18 Jul 2002
Power Supply, inoperative
THE EMERGENCY LIGHTS IN THE COCKPIT AND ENTRY DOOR OVERHEAD, AND THE EGRESS LIGHTS IN THE FIRST CLASS SECTION, WERE INOPERATIVE. REPLACED THE POWER SUPPLY FOR…
- 5 Jul 2002
Transmitter, false indication
DURING THE CLIMB STAGE OF FLIGHT, RH BRAKE PRESSURE GAUGE INDICATES 500 PSI WITH NO VISIBLE FLUID LOST. GAUGE STILL FAILS TO CORRECTLY REGISTER WITH PUMPS…
- 29 Oct 2001
Control Cable, broken
CREW REPORTED FLAP SPLIT INDICATION ACCOMPANIED WITH ROLL TENDENCY. FOUND T/E FLAP BUS CABLE BROKEN DUE TO CORROSION AND FATIGUE. CHANGED CABLE RUNS 33A AND…
- 22 May 2001
Skin, cracked
DURING CHECK-C MAINT FUSELAGE STA 1380, LONGERON 14L, HAD .25 INCH INCH CRACK AFT OF RIVET. REPAIRED PER SRM 53-04, FIG 18, AND 51-30-2.
- 19 Aug 2000
Battery Pack, discharged
THE COCKPIT AND FWD CABIN AISLE EMERGENCY LIGHTS CAME ON WITH POWER OFF, AND THE OVERWING EMERGENCY LIGHTS CAME ON AND WOULD NOT CYCLE OFF. CLEANED THE…
- 4 Aug 2000
Battery Pack, discharged
THE EGRESS LIGHTING AT SEAT 24C WAS FLASHING INTERMITTENTLY. REPLACED THE BATTERY PACK. CHECK-C 6-19-00 STL.
- 17 May 2000
Battery Pack, inoperative
THE FLOOR EGRESS LIGHTS AT ROWS 31 TO 33 WERE INOPERATIVE. REPLACED THE BATTERY PACK. CHECK-C 6-10-99 MCI.
- 25 May 1999
Frame, corroded
DURING CHECK-C MAINT, FOUND LOWER CHORD ATTACH BOLTS TO STRINGER 30 AND 29L WERE RUSTY AND CORRODED, STA 1060 FRAME. INSTALLED NEW FRAME AT STA 1060 PER SPM…
- 20 May 1999
Longeron, cracked
DURING CHECK-C MAINT, FOUND FUSELAGE LONGERON 20R CRACKED AT FASTENER, UPPER O/B CORNER OF THE WHEEL WELL AT STA 1003. STOP DRILLED CRACK PER SRM 51-00-03 AND…
- 15 May 1999
Support, corroded
DURING CHECK-C MAINT, FOUND MATERIAL REMOVED BEYOND LIMITS FOR CORROSION REMOVAL ON FLOOR SUPPORT, STA 188 TO 193, RBL 44. REPLACED FLOOR SUPPORT AT STA 160…
- 11 May 1999
Angle, cracked
DURING CHECK-C MAINT, FOUND CABIN FRONT SPAR UPPER CAP TIE ANGLE WAS CRACKED APPROX 6 INCHES LONG, STA 826, RBL 58 INCHES. REPLACED TIE ANGLE WITH NEW PART…
- 8 May 1999
Angle, cracked
DURING CHECK-C MAINT, FOUND LOWER RT VERTICAL STABILIZER MOUNT ANGLE CRACKED 2 PLACES AFT END BELOW RUDDER. ACCOMP NDT HFEC FOR CRACK CONTAINMENT AFTER…
- 24 Apr 1998
Support, cracked
MCI- DURING OP 15 MAINTENANCE CHECK, FOUND FORWARD INBOARD CORNER OF LT WHEEL WELL FAIRING SUPPORT STRUCTURE CRACKED, FWD AND AFT SIDES, LBL 6. INSTALLED…
- 24 Apr 1998
Frame, cracked
MCI - DURING OP 15 MAINTENANCE CHECK FOUND IN LT GEAR WHEEL WELL, FS 940 LBL 4, FRAME WEB CRACKED AND U-CHANNEL AFT SIDE OF WEB CRACKED IN 2 PLACES. INSTALLED…
- 24 Apr 1998
Floor, corroded
MCI - DURING OP 15 MAINTENANCE CHECK, FOUND LIGHT CORROSION AROUND SCREW HOLES IN FLOOR MEMBRANE AT FS 1250, LBL 47 TO LBL 53. REMOVED CORROSION PER SRM…
- 23 Apr 1998
Angle, cracked
MCI - DURING OP 15 MAINTENANCE CHECK, FOUND T-ANGLES FOR FILLET FAIRING ATTACH STRUCTURE CRACKED AT CENTERLINE, STA 864, 875, AND 886. THREE CRACKS. REPLACED…
- 22 Apr 1998
Floor, corroded
MCI - DURING OP 15 MAINTENANCE CHECK, FOUND HOLD CORRODED THROUGH CABIN FLOOR MEMBRANE AT STATION 172, RBL 52. REPAIRED PER SRM 53-01, FIG 4 AND TWA STD…
- 22 Apr 1998
Frame, cracked
MCI - DURING OP 15 MAINTENANCE CHECK, FOUND RT MLG WHEEL WELL FS 940, RBL 4, FRAME WEB CRACKED AND U-CHANNEL CRACKED AFT SIDE OF WEB. REPLACED U-CHANNEL AND…
- 22 Apr 1998
Angle, cracked
MCI - DURING OP 15 MAINTENANCE CHECK, FOUND ANGLE BRACE CRACKED AND DOUBLER BELOW ALSO CRACKED, JUST INBD OF NR 2 LE SLAT INBD TRACK. MANUFACTURED ANGLE BRACE…
- 22 Apr 1998
Stiffener, cracked
MCI - DURING OP 15 MAINTENANCE CHECK, FOUND VERTICAL STIFFENER BELOW FLOOR AT STA 927, LBL 44, CRACKED. REPAIRED PER SRM 51-01. INSTALLED NEW CASTING. (X)
- 17 Apr 1998
Floor Track, corroded
MCI - DURING OP 15 MAINTENANCE CHECK, FOUND CORROSION ON RT FLOOR TRACK FROM FS 1212 TO 1322. REMOVED AND REPLACED TRACK PER SRM 51-01, PAGE 2 ITEM C, AND TWA…
- 17 Apr 1998
Floorbeam, corroded
MCI - DURING OP 15 MAINTENANCE CHECK, FOUND CORROSION ON FLOORBEAM FS 200, RBL 58 IN. REMOVED FLOOR SUPPORT BEAM AND INSTALLED NEW BEAM PER SRM 51-01 AND TWA…
- 16 Apr 1998
Floorbeam, corroded
MCI - DURING OP15 MAINTENANCE CHECK, FOUND CORROSION ON FLOORBEAM AT FS 197, LBL 6 INCH. REPLACED BEAM PER SRM 51-01, AND STD PRACTICES. (M)
- 14 Apr 1998
Floorbeam, corroded
MCI - DURING OP15 MAINTENANCE CHECK, FOUND CORROSION ON FLOORBEAM AT FS 180, RBL 20 INCH TO 43 INCH. REMOVED AND INSTALLED NEW FLOORBEAM PER SRM 51-01. (M)
- 14 Apr 1998
Floorbeam, corroded
MCI - DURING OP 15 MAINTENANCE CHECK, FOUND CORROSION ON FLOORBEAM CAP, FS 200, LBL 12 IN. REPLACED CAP PER SRM 51-01. (X)
- 13 May 1997
Stator Support, cracked
IAD - FLT 341 - DURING CLIMB, A LOUD BANG WAS HEARD ACCOMPANIED BY A RISE IN EGT ON NR 2 ENGINE, SN 1227. ENGINE WAS SHUT DOWN IN-FLIGHT. ENGINE TOTAL TIME:…