N959JB
2015 Airbus A321-231 standard FAA →
registration
- 2015
aircraft radio
1 past record
earlier registrations
1 past record
- 1977
service difficulty reports
25 reports
- 18 Mar 2026
Actuator, failed
FLT #1058 AUA-JFK (EMERGENCY DECLARED)." F/CTRL SLATS FAULT.; PERFORMED T/S PER TSM 27-81-00-810-A FOUND SLAT ACTUATOR TORQUE LIMITER TRIPPED. R/R SLAT…
- 31 Aug 2024
Unknown, odor
FLT#1058, AUA-JFK. 'FUME EVENT DURING DESCENT; COMPLIED WITH INFORMATION NOTICE 2017-T015, SECTION A, ISOLATED FAULT TO TYPE 10, PER TSM 05-50-00-810-085-B /…
- 30 Sep 2023
Unknown, unknown
FLT#939, JFK-SJD. (AIRCRAFT PERFORMED AN AIR TURN ABCK TO JFK) 'AIR ENG 2 BLEED ABNORMAL PR; REF AML 3758745-1 (INSTALLED PRSOV VALVE ON ENG 2 IAW AMM…
- 14 Mar 2023
Unknown, unknown
FLT#937, JFK-STI. 'DIRTY SOCK FUNE SMELL DURING DESCENT OUT OF 10,000 FEET INTO STI, OBSERVED IN FLIGHT DECK ONLY; COMPLIED WITH INFO NOTICE 2017 -T015, SEC…
- 3 Mar 2023
None, none
FLT#698, MCO-LGA. (AIRCRAFT PERFORMED AN AIR TURN BACK TO MCO) ' AT FL180, ECAM FOR HYD G RSVR LO LVL ECAM AND QRH COMPLETED AND RETURNED TO MCO. HYD FLUID…
- 3 Dec 2022
Power Supply, no test
FLT#828, MCO-EWR. 'AFTER DOING R3 ESCAPE SLIDE TASK CARDS. EMERGENCY LIGHTING SYS TEST FALL ON CIDS; REMOVED AND REPLACED AFT EPSU 13WL IAW 33-51-38. OPS…
- 3 Dec 2022
Slide, no test
FLT#828, MCO-EWR. 'AFTER DOING R3 ESCAPE SLIDE TASK CARD. EMERGENCY LIGHTING SYSTEM TEST FAIL ON CIDS; OPERATIONAL TEST OF EMERGENCY LIGHTING SYSTEM FAULTS…
- 31 May 2022
Bleed Air Sys, odor
FLT#923, BOS-STI. 'LEVELING AT 6000' IN CLOUDS AN ODOR WAS SMELLED AND LASTED ABOUT 15 SECONDS. APU OFF, ENG BLEEDS ON; COMPLIED WITH INFO NOTICE 2017-T015,…
- 14 Mar 2022
None, none
FLT#165, BOS-RSW. ' FLIGHT ATENDANTS ADVISED OF DIRTY SOCK SMELL DSCENDING FROM APPROXIMATELY 8000 - 3000 SMELL DID DISSIPATE; C/W INFO NOTICE 2017-1015…
- 17 Jan 2022
A/C Pack, odor
FLT # 1869, JFK-PUJ. ODOR IN COCKPIT AND CABIN DESCENDING THRU 10K AT IDLE THRUST CONTINUED THRU ENGINE SHUTDOWN. SLIGHT SMELL DURING TAKEOFF BUT DISSIPATED…
- 3 Apr 2020
Battery, failed
FT # 1802, FLL-JFK. REF T/C A320-33-51-00 EPSU BATTERY 13WL AND 10WL FAILED BAT CAP TEST; R & R EPSU BATTERY 13WL AND 10WL BITE GOOD. NO FAULTS NOTED REF MM…
- 3 Apr 2020
Battery, failed
FT # 1802, FLL-JFK. REF T/C A320-33-51-00 EPSU BATTERY 13WL AND 10WL FAILED BAT CAP TEST; R & R EPSU BATTERY 13WL AND 10WL BITE GOOD. NO FAULTS NOTED REF MM…
- 3 Apr 2020
Battery, failed
FT # 1802, FLL-JFK. REF T/C A320-33-51-00-710-003 EPSU BATTERY 12WL AND 11WL FAIL BATTERY CAP TEST; R & R EPSU BATTERY 11WL AND 12WL BITE GOOD. NO FAULTS…
- 3 Apr 2020
Battery, failed
FT # 1802, FLL-JFK. REF T/C A320-33-51-00-710-003 EPSU BATTERY 12WL AND 11WL FAIL BATTERY CAP TEST; R & R EPSU BATTERY 11WL AND 12WL BITE GOOD. NO FAULTS…
- 3 Apr 2020
Battery, failed
FT # 1802, FLL-JFK. REF T/C A320-33-51-00-710-003 EPSU BATTERY 14WL AND 15WL FAIL BATTERY CAP TEST; R & R EPSU BATTERY 14WL AND 15WL BITE GOOD. NO FAULTS…
- 3 Apr 2020
Battery, failed
FT # 1802, FLL-JFK. REF T/C A320-33-51-00-710-003 EPSU BATTERY 14WL AND 15WL FAIL BATTERY CAP TEST; R & R EPSU BATTERY 14WL AND 15WL BITE GOOD. NO FAULTS…
- 25 Jan 2019
Door, corroded
DURING HEAVY MAINTENANCE, CORROSION WAS FOUND AROUND THE DRAIN MAST AREA AT THE RH APU ACCESS DOOR BTWN FR 80A-81A & STGR 20. CONTACTED MANUFACTURERFOR REPAIR…
- 30 Sep 2018
Slide, failed
FLT 1452, CUN-JFK. TC A320-25-62-47-400-001-A. ESCAPE SLIDE ENCLOSURE INSTALLATION FAILED ON TEST ITEM 5 OF THE TASK CARD. FOUND L1 DOOR SLIDE LIGHT FAULT PER…
- 17 Jul 2018
Battery, discharged
FT 1468, PUJ-JFK. EPSU BATTERY AT R2 DOOR INOP. FOUND DURING WEEKLY CHECK. R&R EPSU BATTERY ABOVE R2 DOOR PER AMM 33-51-38. OPS CHECK OK PER AMM 33-51-00.
- 27 Aug 2017
Battery Pack, failed
EMERGENCY LIGHTS INOPERATIVE WHEN POWER REMOVED FROM ACFT. R & R THE BATTERIES & THE POWER SUPPLY IAW AMM 33-51-38. OPS CHECKED GOOD. NO DEFECT NOTED. OK FOR…
- 27 Aug 2017
Battery Pack, failed
EMERGENCY LIGHTS INOPERATIVE WHEN POWER REMOVED. R & R THE BATTERIES OF THE EMERGENCY POWER SUPPLY UNIT IAW AMM 33-51-38. OPS CHECKED GOOD. NO DEFECT NOTED.…
- 27 Aug 2017
Battery Pack, failed
EMERGENCY LIGHTS INOPERATIVE WHEN POWER REMOVED. R & R THE BATTERIES IAW AMM 33-51-38. OPS CHECKED GOOD. NO DEFECT NOTED. OK FOR SERVICE.
- 27 Aug 2017
Battery Pack, failed
EMERGENCY LIGHTS INOPERATIVE WHEN POWER REMOVED. R & R THE BATTERIES IAW AMM 33-51-38. OPS CHECKED GOOD. NO DEFECT NOTED. OK FOR SERVICE.
- 27 Aug 2017
Battery Pack, failed
EMERGENCY LIGHTS INOPERATIVE WHEN POWER REMOVED. R & R THE BATTERIES IAW AMM 33-51-38. OPS CHECKED GOOD. NO DEFECT NOTED. OK FOR SERVICE.
- 27 Aug 2017
Power Supply, failed
EMERGENCY LIGHTS INOPERATIVE WHEN POWER REMOVED. R & R THE BATTERIES AND POWER SUPPLY 13WL IAW AMM 33-51-38. OPS CHECKED GOOD. NO DEFECT NOTED. OK FOR SERVICE.