N957R
2005 Robinson Helicopter Company R44 II multiple FAA →
earlier registrations
2 past records
- 2005
- 1972
NTSB
- 18 Sep 2012
accident, Slaton TX
- 13 Dec 1992
accident, Mexico City MX
service difficulty reports
122 reports
- 30 Oct 2000
Panel, delaminated
DURING A MAINTENANCE VISIT FOUND THE COCKPIT FLOOR SEPARATED AT STA -12 TO -32, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.
- 30 Oct 2000
Finger Doubler, corroded
DURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE AND POPPED RIVET HEADS TO THE UPPER SURFACE W/W FINGER DOUBLER BETWEEN STA 902 - 920 AND LBL 4 LBL -4 Z AXIS…
- 30 Oct 2000
Fitting, corroded
DURING A MAINTENANCE VISIT FOUND CORROSION DAMGE TO THE FRAME TO CUSP FITTING AT STA 1460 AND L21R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.
- 30 Oct 2000
Fitting, corroded
DURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE CIRCUMFERENTIAL FRAME FITTING AT STA 1480 AND L21R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.
- 30 Oct 2000
Floor Panel, corroded
DURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE COCKPIT FLOOR PANEL UNDER FE''S CONSOLE, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.
- 30 Oct 2000
Floor Panel, corroded
DURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO BOTH SIDES OF THE COCKPIT FLOOR PANEL UNDER F/E''S DESK, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.
- 30 Oct 2000
Floor Panel, cracked
DURING A MAINTENANCE VISIT FOUND CORROSION AND A CRACK TO THE TOP AND BOTTOM OF THE COCKPIT FLOOR PANEL 679, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.
- 30 Oct 2000
Floor Panel, cracked
DURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE AND A CRACK TO THE COCKPIT FLOOR PANEL NR 677, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.
- 30 Oct 2000
Channel, cracked
DURING A MAINTENANCE VISIT FOUND A CRACK TO THE LEFT I/B FLAP I/B TRAILING EDGE WEDGE CHANNEL, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.
- 30 Oct 2000
Skin, cracked
DURING A MAINTENANCE VISIT FOUND A CRACK TO THE SKIN AT THE LEFT I/B FLAP BOTTOM, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.
- 30 Oct 2000
Angle, cracked
DURING A MAINTENANCE VISIT FOUND A CRACK TO THE TOP RIB ANGLE AT THE LEFT O/B FLAP I/B SCISSOR LINK, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.
- 30 Oct 2000
Skin, cracked
DURING A MAINTENANCE VISIT FOUND A CRACK TO THE O/B FLAP O/B EXHAUST GATE FLANGE, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.
- 30 Oct 2000
Skin, delaminated
DURING A MAINTENANCE VISIT FOUND DELAMINATION TO THE LEFT WING LWR SURFACE T/E PANEL NR 577B, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.
- 30 Oct 2000
Panel, delaminated
DURING A MAINTENANCE VISIT FOUND DELAMINATION TO THE LT WING LWR SURFACE T/E PANEL AT STA 138 TO 214, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.
- 30 Oct 2000
Panel, delaminated
DURING A MAINTENANCE VISIT FOUND DELAMINATION TO THE LT WING LWR SURFACE T/E PANEL AT STA XW 98 TO XW 138, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.
- 30 Oct 2000
Panel, delaminated
DURING A MAINTENANCE VISIT FOUND DELAMINATION TO THE LT WING LWR SURFACE T/E PANEL AT STA 98, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.
- 30 Oct 2000
Panel, delaminated
DURING A MAINTENANCE VISIT FOUND DELAMINATION AND A DENTED HOLE TO THE LT WING LWR SURFACE T/E PANEL UNDER HYD TANK, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.
- 30 Oct 2000
Panel, delaminated
DURING A MAINTENANCE VISIT FOUND A DELAMINATED PANEL ON THE LT WING LWR T/E AT STA XW 5.00 TO XW 98, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.
- 25 Oct 2000
Skin, corroded
DURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE ALONG THE MOUNTING SURFACE OF THE NR 2 ADF AT STA 145 - 170 AND L36 TO L35L, DAMAGE EXCEEDED LIMITATIONS IAW…
- 20 Oct 2000
Angle, cracked
DURING A MAINTENANCE VISIT FOUND A CRACK TO THE ATTACH ANGLE AT THE RIGHT W/W AT STA XWO ABOVE L24R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.
- 20 Oct 2000
Rib, cracked
DURING A MAINTENANCE VISIT FOUND CORROSION AT RIGHT I/B FLAP-RIB-LOC AT STA XW 64 18 - 20 INCHES AFT OF FLAP FRONT SPAR, DAMAGE EXCEEDED LIMITATIONS IAW DC-8…
- 18 Oct 2000
Fitting, misdrilled
DURING A MAINTENANCE VISIT FOUND A DRILLED AREA TO THE CIRCUMFERENTIAL FRAME FITTING AT STA 640 AND L21R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.
- 16 Oct 2000
Fitting, cracked
DURING A MAINTENANCE VISIT FOUND A CRACK TO THE INTERCOSTAL ATTACH FITTING BETWEEN MLG DOORS AT STA 930, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.
- 13 Oct 2000
Fitting, cracked
DURING A MAINTENANCE VISIT FOUND A CRACK TO THE INTERCOSTAL ATTACH FITTINGS BETWEEN MLG DOORS AT STA 890, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.
- 13 Oct 2000
Fitting, cracked
DURING A MAINTENANCE VISIT FOUND A CRACK TO THE INTERCOSTAL ATTACH FITTING BETWEEN MLG DOORS AT STA 950, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.
- 13 Oct 2000
Fitting, cracked
DURING A MAINTENANCE VISIT FOUND A CRACK TO THE INTERCOSTAL ATTACH FITTINGS BETWEEN MLG DOORS AT STA 960, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.
- 13 Oct 2000
Intercostal, cracked
DURING A MAINTENANCE VISIT FOUND A CRACK TO THE INTERCOSTAL BETWEEN MLG DOORS AT STA 940, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.
- 13 Oct 2000
Intercostal, cracked
DURING A MAINTENANCE VISIT FOUND A CRACKED INTERCOSTAL BETWEEN MLG DOORS AND LT AND RT ATTACH FITTINGS AT STA 902, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.
- 13 Oct 2000
Bulkhead, cracked
DURING A MAINTENANCE VISIT FOUND A CRACK AND MISSING FASTENERS TO THE A & B PIT CENTER DIVIDER WALL, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.
- 13 Oct 2000
Stringer, chafed
DURING A MAINTENANCE VISIT FOUND A CHAFED STRINGER SIDEWALL AND HOLES ELONGATED ON THE NR 4 THRUST REVERSER, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.
- 12 Oct 2000
Web, misdrilled
DURING A MAINTENANCE VISIT FOUND HOLES IN WEB BETWEEN STA 260 - 280 LT, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.
- 12 Oct 2000
Longeron, misdrilled
DURING A MAINTENANCE VISIT FOUND DRILL STARTS AND HOLES IN STRINGER AT STA 440 RT, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.
- 12 Oct 2000
Frame, misdrilled
DURING A MAINTENANCE VISIT FOUND A DRILL START AT FLOOR LEVEL AT STA 1280 RT, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.
- 12 Oct 2000
Web, tool damage
DURING A MAINTENANCE VISIT FOUND DRILL HOLES AND DRILL STARTS IN WEB AT STA 1340 RT, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.
- 10 Oct 2000
Longeron, corroded
DURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE BETWEEN STA 1080 - 1100 AND L36, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.
- 10 Oct 2000
Panel, delaminated
DURING A MAINTENANCE VISIT FOUND A DELAMINATED AND DETERIORATED PANEL 632 TOP AND O/B SIDE, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.
- 10 Oct 2000
Structure, cracked
DURING A MAINTENANCE VISIT FOUND A CRACKED CORNER AT RIVET HOLE TO THE RT MAIN GEAR DOOR FWD LWR END, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.
- 10 Oct 2000
Link, worn
DURING A MAINTENANCE VISIT FOUND EXCESSIVE PLAY TO THE LEFT O/B FLAP LWR SCISSOR LINK BOLT, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.
- 10 Oct 2000
Link, worn
DURING A MAINTENANCE VISIT FOUND EXCESSIVE PLAY IN THE LEFT O/B FLAP MID SCISSOR LINK BOLT, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.
- 6 Oct 2000
Structure, worn
DURING A MAINTENANCE VISIT FOUND A WORN EDGE ON THE AFT NR 2 ENGINE LT PYLON SKIRT, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.
- 6 Oct 2000
Skin, dented
DURING A MAINTENANCE VISIT FOUND SEVERAL DING AREAS ON THE LEFT I/B FLAP BOTTOM, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.
- 5 Oct 2000
Floorbeam, corroded
DURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE AND POPPED RIVETS AT BEAM LOWER CHORD/WEB AT STA 702 LBL 45 TO 52.5 & LBL 55.5 TO 61 Z AXIS -7 FWD AND AFT…
- 5 Oct 2000
Frame, corroded
DURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE FRAME IN -A- PIT AT STA 180 AND L36L TO L35L, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.
- 5 Oct 2000
Frame, corroded
DURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE FRAME LOWER CHORD IN -A- PIT AT STA 160 AND L36, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.
- 4 Oct 2000
Mount, gouged
DURING A MAINTENANCE VISIT FOUND A GOUGED FWD MOUNT ON THE NR 3 ENGINE, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.
- 3 Oct 2000
Floorbeam, cracked
DURING A MAINTENANCE VISIT FOUND CORROSION EXFOLIATION TO THE FLOORBEAM AT STA 702 AND X+50, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.
- 3 Oct 2000
Web, cracked
DURING A MAINTENANCE VISIT FOUND A CRACK IN WEB WHERE WEDGE ATTACH POINT IS ON THE RIGHT I/B FLAP AT STA XW 75, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.
- 3 Oct 2000
Bracket, cracked
DURING A MAINTENANCE VISIT FOUND A CRACK TO THE RIGHT I/B LWR SCISSOR PANEL SUPPORT BRACKET, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.
- 22 Sep 2000
Skin, cracked
DURING A MAINTENANCE VISIT FOUND A CRACK TO THE TAIL SECTION THROUGH DOOR NR 62 LT TAIL CONE AT BRACE AND SKIN ATTACHMENT AT STA 1930, DAMAGE EXCEEDED…
- 22 Sep 2000
Seat Track, worn
DURING A MAINTENANCE VISIT FOUND A WORN FLOOR TRACK AT STA 1065 AND X=-45, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.
- 22 Sep 2000
Seat Track, worn
DURING A MAINTENANCE VISIT FOUND A WORN SEAT TRACK AT STA 1400 AND X+24, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.
- 22 Sep 2000
Threshold, gouged
DURING A MAINTENANCE VISIT FOUND GOUGED, CRACKED AND SEPARATING SKIN ON THE B-PIT THRESHOLD, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.
- 22 Sep 2000
Threshold, cracked
DURING A MAINTENANCE VISIT FOUND GOUGED, CRACKED AND DOUBLER LOOSE ON THE D-PIT THRESHOLD, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.
- 22 Sep 2000
Seat Track, damaged
DURING A MAINTENANCE VISIT FOUND ELONGATED AND GOUGED HOLES ON THE FE''S LT SEAT TRACK LOCK HOLES, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.
- 22 Sep 2000
Skin, dented
DURING A MAINTENANCE VISIT FOUND SEVERAL DENTS IN A LARGE AREA O/B OF I/B SLOT DOOR AT STA XFS 250, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.
- 22 Sep 2000
Skin, dented
DURING A MAINTENANCE VISIT FOUND A DENTED I/B FLAP FAIRING AFT END, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.
- 22 Sep 2000
Link, gouged
DURING A MAINTENANCE VISIT FOUND A GOUGE TO THE LEFT I/B FLAP SUPPORT AFT LINK AT STA 98 LT, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.
- 22 Sep 2000
Skin, punctured
DURING A MAINTENANCE VISIT FOUND A PUNCTURE TO THE LEFT WING CONTROL TAB ON I/B AILERON T/E, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.
- 22 Sep 2000
Frame, cracked
DURING A MAINTENANCE VISIT FOUND A CRACK TO THE LEFT O/B FLAP WELL I/B OF O/B ACTUATOR FRAME FOR SPOILER ATTACHMENT, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.
- 22 Sep 2000
Stiffener, gouged
DURING A MAINTENANCE VISIT FOUND A GOUGED LEFT DUMP CHUTE UPPER SURFACE I/B SKIN STIFFENER, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.
- 22 Sep 2000
Support Fitting, gouged
DURING A MAINTENANCE VISIT FOUND A GOUGED SUPPORT ON O/B AND I/B SIDES OF THE LEFT I/B FLAPS AT STA 98, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.
- 22 Sep 2000
Link, gouged
DURING A MAINTENANCE VISIT FOUND A GOUGE TO THE SUPPORT AFT LINK ON THE LEFT I/B FLAP SUPPORT AT STA 98 LT, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.
- 22 Sep 2000
Frame, cracked
DURING A MAINTENANCE VISIT FOUND A CRACK TO THE LEFT WING O/B FLAP I/B FRAME, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.
- 21 Sep 2000
Cargo Track, worn
DURING A MAINTENANCE VISIT FOUND A WORN CARGO TRACK AT STA 1392 LEFT X+24, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.
- 21 Sep 2000
Cargo Track, worn
DURING A MAINTENANCE VISIT FOUND A WORN CARGO TRACK AT STA 1390 LEFT AND X+45, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.
- 21 Sep 2000
Access Panel, cracked
DURING A MAINTENANCE VISIT FOUND A CRACK AND DEFORMED ON THE I/B AILERON BOTTOM SIDE ACCESS PANEL FOR CONTROL TAB/POWER PACK TIE-IN, DAMAGE EXCEEDED…
- 21 Sep 2000
Skin, gouged
DURING A MAINTENANCE VISIT FOUND A LARGE GOUGE TO THE SKIN ON THE I/B FLAP P/B AT STA 98, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.
- 21 Sep 2000
Skin, bulged
DURING A MAINTENANCE VISIT FOUND A LARGE BULGE TO THE I/B FLAP T/E AT STA 98, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.
- 21 Sep 2000
Panel, delaminated
DURING A MAINTENANCE VISIT FOUND A DELAMINATED PANEL BETWEEN MAIN GEAR DOORS, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.
- 21 Sep 2000
Frame, cracked
DURING A MAINTENANCE VISIT FOUND A CRACKED FRAME AT ''D'' PIT AT STA 1400 AND L29R TO L30R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.
- 21 Sep 2000
Skin, cracked
DURING A MAINTENANCE VISIT FOUND A CRACK NEXT TO THE FUSELAGE ON THE RIGHT I/B FLAP WEB I/B, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.
- 21 Sep 2000
Skin, cracked
DURING A MAINTENANCE VISIT FOUND A TORN, BENT AND CRACKED LOWER DOUBLER ON THE C-PIT DOOR DOUBLER AT STA 1160 - 1220 AND L31R, DAMAGE EXCEEDED LIMITATIONS IAW…
- 20 Sep 2000
Cargo Track, worn
DURING A MAINTENANCE VISIT FOUND A WORN CARGO TRACK AT STA 1220 LT AND X+24, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.
- 20 Sep 2000
Cargo Track, worn
DURING A MAINTENANCE VISIT FOUND A GOUGED AND WORN CARGO TRACK AT STA 1400 CENTER LINE AND X-0, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.
- 20 Sep 2000
Cargo Track, worn
DURING A MAINTENANCE VISIT FOUND A WORN CARGO TRACK AT STA 1700 AND X-0, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.
- 20 Sep 2000
Fitting, corroded
DURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE CIRCUMFERENTIAL FRAME AND FITTING AT STA 1440 AND L21R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.
- 20 Sep 2000
Cargo Track, worn
DURING A MAINTENANCE VISIT FOUND A WORN CARGO TRACK AT STA 1130 LEFT AND X+45, DAMAGE EXCEEDED LIMIITATIONS IAW DC-8 SRM.
- 20 Sep 2000
Cargo Track, worn
DURING A MAINTENANCE VISIT FOUND A WORN CARGO TRACK AT STA 1130 CENTER LINE AND X=0, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.
- 20 Sep 2000
Cargo Track, worn
DURING A MAINTENANCE VISIT FOUND A WORN CARGO TRACK AT STA 1208 CENTER LINE AT X=0, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.
- 20 Sep 2000
Skin, cracked
DURING A MAINTENANCE VISIT FOUND A CRACK ON THE CORNER OF THE I/B AILERON I/B TAB T/E, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.
- 20 Sep 2000
Skin, chafed
DURING A MAINTENANCE VISIT FOUND A GOUGE AROUND SCREW HOLE ON L/E BOTTOM SIDE AT STA XFS 472, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.
- 20 Sep 2000
Cargo Track, worn
DURING A MAINTENANCE VISIT FOUND A GOUGED AND WORN CARGO TRACK AT STA 1680 LT AND X+22, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.
- 20 Sep 2000
Cargo Track, worn
DURING A MAINTENANCE VISIT FOUND A GOUGED AND WORN CARGO TRACK AT STA 1600 AND X+44, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.
- 20 Sep 2000
Cargo Track, worn
DURING A MAINTENANCE VISIT FOUND A WORN CARGO TRACK AT STA 1580 CENTER LINE AND X-0, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.
- 18 Sep 2000
Fitting, corroded
DURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE DOUBLER ON THE CIRCUMFERENTIAL FRAME FITTING AT STA 1140 AND L21R, DAMAGE EXCEEDED LIMITATIONS IAW…
- 18 Sep 2000
Skin, corroded
DURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO THE FUSELAGE SKIN OF ''B'' PIT THRESHOLD, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.
- 18 Sep 2000
Skin, dented
DURING A MAINTENANCE VISIT FOUND A LARGE DENTED AREA 14 INCHES AFT OF L/E ON THE I/B FLAP DIRECTLY BEHIND NR 8 TIRE, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.
- 18 Sep 2000
Skin, dented
DURING A MAINTENANCE VISIT FOUND SEVERAL DENTS IN LEFT L/E AT STA XFS 560 TO XFS 710, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.
- 18 Sep 2000
Skin, chafed
DURING A MAINTENANCE VISIT FOUND CHAFE MARKS INSIDE LT AFT OF THRUST REVERSER, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.
- 18 Sep 2000
Frame, tool damage
DURING A MAINTENANCE VISIT FOUND A DRILL START TO THE FRAME I/B LET 4 INCHES ABOVE LEFT CUSP AT STA 300, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.
- 16 Sep 2000
Angle, cracked
DURING A MAINTENANCE VISIT FOUND A 1.5 INCH CRACK ON THE RT LWR TRAPAZOID LWR ANGLE AT STA XW 0 20.5 INCHES FROM LWR REAR SPAR, DAMAGE EXCEEDED LIMITATIONS…
- 6 Sep 2000
Panel, cracked
DURING A MAINTENANCE VISIT FOUND A CRACK IN TWO PLACES IN FWD RADIUS ON THE RT CTC DISCHARGE EXHAUST PANEL, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.
- 30 Aug 2000
Skin, dented
DURING A MAINTENANCE VISIT FOUND A LARGE DENTED AREA APPROX 2 FEET LONG ON THE LT I/B FLAP DIRECTLY BEHIND MLG, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.
- 30 Aug 2000
Skin, gouged
DURING A MAINTENANCE VISIT FOUND A GOUGE APPROX 1 INCH LONG ON THE LEFT I/B FLAP APPROX 18 INCHES AFT OF L/E, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.
- 30 Aug 2000
Skin, damaged
DURING A MAINTENANCE VISIT FOUND A LARGE HOLE IN SKIN APPROX 1 INCH IN DIAMETER ON THE LEFT I/B FLAP APPROX 12 INCHES AFT OF L/E, DAMAGE EXCEEDED LIMITATIONS…
- 30 Aug 2000
Skin, dented
DURING A MAINTENANCE VISIT FOUND A LARGE DENT FWD OF REPAIR DOUBLER ON THE LEFT I/B FLAP APPROX 14 INCHES AFT OF L/E, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.
- 28 Aug 2000
Rib, cracked
DURING A MAINTENANCE VISIT FOUND A CRACKED RIB EMANATING FROM CUTOUT INTERIOR ABOVE WEDGE ON THE RIGHT I/B FLAP, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.
- 28 Aug 2000
Fitting, gouged
DURING A MAINTENANCE VISIT FOUND A GOUGED RIGHT CANOE FITTING O/B AFT EDGE OF FITTING AT STA 98, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.
- 28 Aug 2000
Rib, cracked
DURING A MAINTENANCE VISIT FOUND A CRACK TO THE UPPER RIB ON THE RIGHT O/B LEADING EDGE AT STA XFS 841, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.
- 28 Aug 2000
Web, gouged
DURING A MAINTENANCE VISIT FOUND A GOUGED TO THE WEB IN 2 PLACES FWD AND AFT ON THE LEFT I/B FLAP I/B WEB AT STA 980, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.
- 5 Aug 2000
Skin, damaged
DURING A MAINTENANCE VISIT, FOUND A HOLE 1.5 INCH IN SIZE IN I/B LEFT FLAP BELOW FAIRING AT STA 98, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM.
- 20 Oct 1998
Fitting, loose
LOST HYDRAULIC FLUID UP TO EMERGENCY LEVEL DURING CLIMBOUT TO LEVEL 330. PERFORMED ABNORMAL HYDRAULIC CHECKLIST PER QRH. TIGHTENED B-NUT FITTING ON NR 2 ENG…
- 29 May 1998
Wire, broken
STRONG ELEC ODOR DEVELOPING IN COCKPIT. TURNED OFF MAX WHITE LIGHTS. ODOR DISSIPATED. DEFERRED PER MEL 33-1 CAT 'C' DUE 6-9-98 CONT NR 805491. PLACARD…
- 19 Mar 1998
Airspeed Ind, malfunctioned
CAPTAINS AIRSPEED IND WENT TO ZERO ON CLIMBOUT. AFTER BEING AIRBORNE FOR 15 MINUTES A/S INDICATOR CAME UP TO 300 KTS AND REMAINED THERE. DISCONNECTED ALL…
- 27 Mar 1997
Generator, failed
HAD ZNS ON NR 3 GENERATOR, RESET FIELD AS PER QRH. 5 MINUTES LATER GENERATOR TRIPPED AGAIN. RETURNED TO OAK AS PER OPS. RESET NR 3 BUS FAULT, RESET FAULT SW…
- 5 Feb 1997
Trim Cylinder, failed
AFTER TAKEOFF GDL, LOST HYDRAULIC FLUID, RETURNED TO GDL. *** CORRECTIVE ACTION *** REMOVED AND REPLACED LEFT MLG BOGIE TRIM CYLINDER HYDRAULIC HOSE. SERVICED…
- 20 Aug 1996
Frame, misdrilled
DURING C-CHECK, FOUND 2 HOLES DRILLED IN FRAME INBD FLANGE 3 AND 12 ABOVE FLOOR IN UPPER CARGO COMPARTMENT, Y=440, LT SIDE. FABRICATED REPAIR ANGLE IAW DER…
- 20 Aug 1996
Frame, misdrilled
DURING C-CHECK, FOUND HOLE DRILLED IN FRAME INBD FLANGE, LT SIDE OF UPPER CARGO COMPARTMENT, Y=320, 3 ABOVE FLOOR. REMOVED FASTENERS, FABRICATED REPAIR ANGLE…
- 20 Aug 1996
Frame, misdrilled
DURING C-CHECK, FOUND 6 HOLES DRILLED IN FRAME, LT SIDE OF UPPER CARGO COMPARTMENT ABOVE CUSP, 9 AFT OF CARGO DOOR, Y=280. FABRICATED AND DRILLED REPAIR…
- 20 Aug 1996
Frame, misdrilled
DURING C-CHECK, FOUND 4 HOLES DRILLED IN FRAME, LT SIDE AT AFT LOWER CORNER OF CARGO DOOR. REMOVED FASTENERS IN REPAIR AREA, FABRICATED AND INSTALLED REPAIR…
- 20 Aug 1996
Frame, misdrilled
DURING C-CHECK, FOUND HOLE DRILLED IN RADIUS OF FRAME AT CUSP FITTING, RH Y=240. FORMED REPAIR ANGLE FROM 7075-0 MATERIAL AND HEAT TREATED TO T-6 CONDITION…
- 20 Aug 1996
Frame, corrosion
DURING C-CHECK, FOUND CORROSION UNDER NUTPLATE ON FRAME AND FRAME SPLIT IN AFT LOWER COMPARTMENT, Y=1100 ABOVE LONGERON 34 RT. REMOVED CORROSION, CUT OUT…
- 20 Aug 1996
Skin, cracked
DURING C-CHECK, FOUND UPPER LEADING EDGE GOUGED AND CRACKED AT XRS 289. STOP DRILLED CRACK, FABRICATED DOUBLER FROM .063 7075T-6AL, IAW DER APPROVED…
- 20 Aug 1996
Frame, corroded
DURING C-CHECK, FOUND CORROSION ON FRAME Y=1060, AT LONGERON 36 UNDER NUTPLATE AND 35 LEFT, Y=1040 AT LONGERON 33 AND 34 RIGHT, UNDER NUTPLATES. REMOVED…
- 20 Aug 1996
Skin, corroded
DURING C-CHECK, FOUND RT WING LEADING EDGE UPPER ATTACHMENT DAMAGED AT FASTENERS APPROX XFS 20. REMOVED FASTENERS, REMOVED CORROSION, FABRICATED REPAIR…
- 20 Aug 1996
Skin, corroded
DURING C-CHECK, FOUND FUSELAGE SKIN BULGED AT Y=350, X=-19 AND Z=-59 FWD FUSELAGE. REMOVED FASTENERS ON A-PIT DOOR DOUBLER TO Y=330 AND TO LONGERON 28. CUT…
- 20 Aug 1996
Skin, corroded
DURING C-CHECK, FOUND INTERNAL DOUBLER CORRODED AT Y=220 TO 265 AND LONGERONS 35L TO 35R, ALSO INNER SKIN CORRODED AND BULGED AT Y=224 BETWEEN LONGERONS 33R…
- 20 Aug 1996
Structure, corroded
DURING C-CHECK, FOUND FLOOR TO FRAME FITTING AT Y=920 UPPER WEB, HAD CORROSION INSIDE RT WHEEL WELL. CUT UPPER WEB, REMOVED CORROSION IAW DC-8 SRM 51-1-8,…
- 20 Aug 1996
Longeron, corroded
DURING C-CHECK, FOUND CORROSION ON LONGERON 27R AT GROUND AIR CONDITION CONNECTOR PANEL DOME NUT AT Y=42. REMOVED DOME NUTS, REMOVED CORROSION AND FOUND…
- 20 Aug 1996
Skin, corroded
DURING C-CHECK, FOUND LT UPPER HORIZ STAB LEADING EDGE HAD CORROSION IN 2 PLACES AT ATTACHMENT SCREWS, APPROX. XF=143 AND XF=153. REMOVED OLD REPAIR DOUBLER,…
- 20 Aug 1996
Skin, damaged
DURING C-CHECK, FOUND TEMPORARY REPAIR ON LT HORIZ STAB LEADING EDGE, O/B SECTION. REMOVED TEMPORARY REPAIR, FABRICATED INTERNAL AND EXTERNAL DOUBLERS AND…
- 20 Aug 1996
Frame, corroded
DURING C-CHECK, FOUND CORROSION ON FRAME UNDER NUTPLATES, AT Y=1120 AND LONGERON 36. REMOVED NUTPLATES AND CORROSION, FABRICATED FILLER AND DOUBLERS IAW DER…