Light, disconnected
DEN- EMERGENCY TRACK LIGHTING AT ROWS 16 TO 19 IS INOP. REINSTALLED TRACK LIGHTING, OPS CHECK NORMAL.
- 20 Jan 1998
Wire, disconnected
DEN - TWO EMERGENCY TRACK LIGHTS ARE INOP AT ROW 18. RECONNNECTED WIRES, AT ROW 18. OPS CHECK GOOD.
- 16 Jan 1998
Wire, disconnected
EMERGENCY TRACK LIGHTING IS INOP AT ROWS 20 THROUGH 23. FOUND WIRE DISCONNECTED AT ROW 20. RECONNECTED WIRE, OPS CHECK NORMAL.
- 5 Jan 1998
Lamp, failed
DEN- EMERGENCY FLOOR TRACK LIGHTING AT ROW 18 IS INOP. RELAMPED, OPS CHECK GOOD.
- 25 Dec 1997
Pin, failed
EMERGENCY FLOOR TRACK LIGHTING AT ROW 21 IS INOP. REPLACED SOCKET PIN IN THE LIGHT AT ROW 21, OPS CHECK GOOD.
- 22 Dec 1997
Connector, disconnected
DEN - TRACK LIGHT AT ROW 18 IS INOP. REATTACHED LIGHT, OPS CHECK GOOD.
- 16 Dec 1997
Light, loose
DEN- AFT CABIN EMERGENCY FLOOR TRACK LIGHTING IS INOP. RESECURED LIGHT WIRES, OPS CHECK GOOD.
- 10 Dec 1997
Lamp, failed
DEN - EMERGENCY LIGHTS ARE INOP BETWEEN ROWS 18 AND 16. RELAMPED EMERGENCY LIGHTS BETWEEN ROW 16 AND 18. OPS CHECK GOOD.
- 1 Dec 1997
Wire, disconnected
DEN- EMERGENCY FLOOR TRACK LIGHTING INOP NEAR OVERWING EXIT. RECONNECTED WIRE AT LIGHT FITTING, OPS CHECK GOOD.
- 25 Sep 1997
Engine, failed
FLT 321 - DEN - ON CLIMB-OUT AT 15000 FT, THE NR 2 ENGINE FAILED WITH A LOUD BANG. N1 AND N2 DECREASED RAPIDLY WITH THE EGT CLIMBING THROUGH 946 C. THE ENGINE…
- 24 Jul 1997
Connectors, loose
ROW 17 EMERGENCY TRACK LIGHTING IS INOPERABLE. CONNECTED WIRING CONNECTS AT ROW 17. OPS CHECK GOOD. (X)
- 22 Jul 1997
Wire, loose
EMERGENCY FLOOR TRACK LIGHTING INOPERABLE AT ROW 18. WIRES PULLED FROM LAMP. RECONNECTED WIRES, OPS CHECK GOOD. (X)
- 7 Jul 1997
Lamp, failed
ROW 12 FLOOR EMERGENCY LIGHT INOPERATIVE. RELAMPED. (X)
- 8 Jun 1997
Skin, damage
LEFT AILERON UPPER SURFACE HAS PAINT DAMAGE. REMOVED LEFT AILERON AND LEFT AILERON TRIM TAB, PERFORMED BALANCE CHECK OF LEFT AILERON IAW SRM 51-60-01. (M)
- 5 Jun 1997
Skin, cracked
FOUND AFT ENTRY DOOR, 2 INCHES BELOW LOWER HINGE CUTOUT, SKIN CRACKED BS 956.5, STRINGER 15L (AFT ENTRY DOORWAY). REMOVED DAMAGED AREA, FABRICATED AND…
- 2 Jun 1997
Stringer, damaged
COMPLY WITH BSB 737-53-1170, STRINGER 18A WEB AT BS 727, INSPECT, REPAIR AND PREVENTIVE CHANGE. COMPLIED WITH BSB 737-53-1170. (M)
- 2 Jun 1997
Skin, cracked
NR 6 SLAT, LOWER SURFACE SKIN (JUST BELOW INBOARD AUX TRACT) 3 FASTENERS EXHIBIT EVIDENCE OF CRACKS EMERGING FROM FASTENER HOLES. REMOVED DAMAGED AREA FROM NR…
- 2 Jun 1997
Hinge, worn
NR 1, NR 3 AILERON TAB WING IS WORN. REMOVED AND REPLACED AILERON TAB HINGE PER OHM 57-50-25. (M)
- 1 Jun 1997
Skin, damaged
FUSELAGE SKIN HAS OIL CAN AT BS 1081, RBL 1, WL 207. REMOVED DAMAGED SIN FABRICATED INSTALLED REPAIR DOUBLER PER SRM 52-00-01. (M)
- 31 May 1997
Skin, dented
FOUND SKIN DENTED BS 1088, WI 208.1, LEFT SIDE (DENT NR 034) A=1, Y=.085, A/Y=11.78, DENT FOUND TO BE OUT OF LIMITS PER 737 SRM 53-00-01. DENT OUT OF LIMITS…
- 31 May 1997
Skin, dented
SKIN IS DENTED STATION 1134, WL 208.1 LEFT SIDE (DENT NR 033) A=1.250, Y=0.065, Y=19.23. DENT FOUND TO BE OUT OF LIMITS PER SRM 53-00-01. REMOVED DAMAGED…
- 30 May 1997
Intercostal, bent
INTERCOSTAL BENT AND ATTACH CLIP CRACKED AT STATION 320, WL 157, RBL 6. FABRICATED AND INSTALLED CLIP ON INTERCOSTAL AT STATION 320, WL 157, RBL 6 PER SRM…
- 30 May 1997
Rib, worn
LEFT HORIZONTAL STABILIZER TRAILING EDGE SUPPORT RIB AT ELEVATOR STATION 66.54 HAS SURFACE ABRASION ON OUTBOARD SURFACE. REPAIRED SUPPORT RIB PER SRM…
- 30 May 1997
Rib, worn
LEFT HORIZONTAL STABILIZER TRAILING EDGE SUPPORT RIB AT ELEVATOR STATION 94.07 HAS SURFACE ABRASION ON OUTBOARD AND INBOARD SURFACES. REPAIRED LT HORIZ STAB…
- 30 May 1997
Rib, worn
LEFT HORIZONTAL STABILIZER TRAILING EDGE SUPPORT RIB AT ELEVATOR STATION 149.12 HAS SURFACE ABRASION ON INBOARD SURFACE. REPAIRED SUPPORT RIB PER SRM…
- 30 May 1997
Rib, worn
LEFT HORIZONTAL STABILIZER TRAILING EDGE SUPPORT RIB AT ELEVATOR STATION 121.59 HAS SURFACE ABRASION ON OUTBOARD AND INBOARD SURFACES. RAPAIRED SUPPORT RIB…
- 30 May 1997
Tip, eroded
CF811, LEFT STAB TIP HAS EROSION DAMAGE. REPAIRED PER SRM 55-10-30 AND 51-70-14. (M)
- 30 May 1997
Panel, worn
RIGHT HORIZONTAL STAB MIDDLE BALANCE BAY PANEL IS CHAFING AND GOUGING WEBS ON INBOARD AND OUTBOARD SIDES. REPAIRED RIGHT STAB MIDDLE BALANCE BAY PANEL PER SRM…
- 29 May 1997
Skin, buckled
FUSELAGE SKIN IS BUCKLED AT BS 947.5 AT SKIN LAP JUST FORWARD OF WATER SERVICE PANEL. FABRICATED REPAIR DOUBLER AND FILLER AND INSTALLED PER SRM 53-00-01. (M)
- 29 May 1997
Door, corroded
CORROSION INSIDE OF POTABLE WATER SERVICE DOOR NR 1501 PANEL BS 967. (M)
- 28 May 1997
Lines, kinked
WHILE WORKING FUSELAGE 47 FOUND TWO KINKED LINE ON AFT FIRE BOTTLE. REMOVED DAMAGED LINES. REINSTALLED NEW LINES PER SRM 51-10-02 AND MM 26-21-11. (M)
- 28 May 1997
Bolts, corroded
WHILE WORKING FUSELAGE CARD 47 FOUND CORROSION AROUND FIRE BOTTLE MOUNT BOLTS. (M)
- 28 May 1997
Support, corroded
FLOOR TO SIDE WALL SUPPORT HAS CORROSION AROUND NUTPLATE HOLES FROM STATION 460 TO STATION 500 LEFT. (M)
- 28 May 1997
Intercostal, cracked
AFT CARGO DOOR UPLOCK INTERCOSTAL IS CRACKED (ACCESS REQUIRED) AFT CARGO BAY. INSTALLED AFT CARGO DOOR UPLOCK INTERCOSTAL AS PER SRM 51-10-02, AND SRM…
- 28 May 1997
Service Panel, corroded
AFT LAVATORY SERVICE PANEL HAS CORROSION AROUND GROUND STUD. REMOVED AND REPLACED DOOR PER SRM 51-40-02. (M)
- 28 May 1997
Support, corroded
FLOOR TO SIDE WALL SUPPORT HAS CORROSION AROUND NUTPLATE HOLES AT STATION 400 TO STATION 420 RIGHT. (M)
- 28 May 1997
Support, corroded
FLOOR TO SIDE WALL SUPPORT CORRODED AROUND FASTENER HOLE AT STATION 500 PLUS 12 AND 500B PLUS 15 RIGHT. (M)
- 28 May 1997
Service Panel, corroded
CORROSION ON AFT LAVATORY SERVICE PANEL HINGE (AFT HINGE). REMOVED AND REPLACED HINGE PER SRM 51-40-02. (M)
- 28 May 1997
Support, corroded
FOUND CORROSION ON FLOOR TO SIDE WALL SUPPORT AROUND FASTENER HOLES FROM STATION 380 PLUS 10 TO STATION 440 LEFT (CORROSION EXTENDS UNDER FLOOR PANEL AT STA…
- 13 May 1997
Lens, broken
LENS FOR EMERGENCY TRACK LIGHTING AT ROW 14 NEEDS REPAIR. INSTALLED NEW LENS AT ROW 14. OPS CHECK GOOD. (X)
- 18 Apr 1997
Connector, loose
AFT CABIN EMERGENCY FLOOR TRACK LIGHTING IS INOP. RESECURED CONNECTIONS. (M)
- 8 Apr 1997
Lamp, failed
EMERGENCY FLOOR TRACK LIGHT AT ROWS 14-18 IS INOP. REPLACED LAMPS. (M)
- 30 Mar 1997
Lamp, failed
EMERGENCY EXIT LIGHT AT THE RIGHT AFT DOOR IS INOP. REPLACED LAMPS. (M)
- 20 Mar 1997
Lamp, failed
EMERGENCY FLOOR TRACK LIGHT INOP AT ROW 18. REPLACED LAMP. (M)
- 28 Feb 1997
Lamp, failed
LEFT LOWER EMERGENCY LIGHT INOP. REPLACED LAMP. (M)
- 18 Feb 1997
Light Cover, missing
FOUND EMERGENCY TRACK LIGHT COVER MISSING AT ROW 18. INSTALLED LIGHT COVER. (M)
- 16 Feb 1997
Light, inoperative
FOUND EMERGENCY TRACK LIGHT INOP AT ROWS 19-21. RECONNECTED LIGHT SOCKET AT ROW 21. (M)
- 6 Feb 1997
Light, inoperative
FOUND EMERGENCY TRACK LIGHT INOP AT ROWS 19-21. RECONNECTED LIGHT SOCKET AT ROW 21. (M)
- 8 Dec 1996
Wire, loose
FOUND EMERGENCY FLOOR TRACK LIGHTING INOP AT ROWS 1 AND 2, FIRST THREE LIGHTS. RECONNECTED PINS TO LIGHT SOCKETS. REPLACED BROKEN WIRE. (M)
- 30 Nov 1996
Wire, loose
FOUND EMERGENCY FLOOR TRACK LIGHTING INOP AT ROWS 4, 5, AND 6. RECONNECTED LOOSE WIRE TO LIGHT SOCKETS. (M)
- 26 Nov 1996
Wire, loose
FOUND EMERGENCY TRACK LIGH TINOP AT ROW 19. RESECURED LOOSE WIRE CONNECTION. (M)
- 22 Nov 1996
Wiring, loose
FOUND EMERGENCY FLOOR TRACK LIGHTING INOP AT ROW 22. RESECURED LOOSE WIRE CONNECTION. (M)
- 22 Nov 1996
Lamp, failed
FOUND EXTERIOR EMERGENCY LIGHT INOP ADJACENT TO FORWARD CARGO DOOR. REPLACED LAMP. (M)
- 25 Oct 1996
Light, loose
EMERGENCY EXIT LIGHTING INOP BETWEEN ROWS 16-20. RESEATED LIGHT SOCKET. (M)
- 21 Oct 1996
Bulbs, failed
EMERGENCY EXIT LIGHTING ROWS 18-21 INOP. SECURED SEVERAL LOOSE CONNECTORS AND REPLACED BAD BULBS. (M)
- 7 Oct 1996
Light, loose
EMERGENCY TRACK LIGHTING COMING LOOSE AT ROW 1. SECURED TRACK LIGHTING. (M)
- 30 Sep 1996
Lens, missing
EMERGENCY FLOOR TRACK LIGHTING MISSING LIGHT LENS AT SEAT ROW 18. INSTALLED NEW LIGHT LENS. (M)
- 30 Sep 1996
Light, loose
EMERGENCY FLOOR LIGHTING INOP ROW 1, ROW 14 AND ROWS 19-21. FOUND LOOSE CONNECTION AT ROW 1, 14, AND 19-21. RECONNECTED. (M)
- 31 Aug 1996
Connectors, loose
EMERGENCY EXIT FLOOR LIGHTING INOP BETWEEN ROWS 15 AND 18. RESEATED WIRE CONNECTIONS. (M)
- 21 Jul 1996
Connector, damaged
DURING A-1 CHECK, FOUND FLOOR TRACK EMERGENCY EXIT LIGHTING INOPERATIVE. REPLACED WIRE CONNECTOR. (X)
- 17 Jul 1996
Bulb, failed
DURING SERVICE CHECK FOUND FLOOR TRACK EMERGENCY EXIT LIGHTING INOPERATIVE AT ROW 14. RELAMPED LIGHT ASSEMBLY AT ROW 14. (X)
- 17 Jul 1996
Connector, disconnected
DURING SERVICE CHECK FOUND FLOOR TRACK EMERGENCY EXIT LIGHTING INOPERATIVE BETWEEN ROWS 19 AND 20. RECONNECTED LIGHT PLUG BETWEEN ROWS 19 AND 20. (X)
- 1 Jul 1996
Light Bulb, failed
FOUND EXTERNAL EMERGENCY EXIT LIGHT INOPERATIVE FOR R-2 DOOR. RELAMPED LIGHT ASSEMBLY. (X)