N951U
1984 McDonnell Douglas DC-9-82(MD-82) standard FAA →
earlier registrations
1 past record
- 1984
NTSB
- 11 Apr 1998
incident, Washington DC
service difficulty reports
57 reports
- 20 May 2009
Seat Track, corroded
CORROSION BEYOND LIMITS ON SEAT TRACK NR 5. INSTALLED PLUG PER AARD 53-20-00-10.
- 15 May 2009
Longeron, cracked
LONGERON 20L CRACKED AT STATION 1003. STOP DRILLED CRACK AND INSTALLED DOUBLER PER AARD 53-10-00-18.
- 15 May 2009
Support Angle, cracked
NR 2 SEAT TRACK SUPPORT ANGLE CRACKED AT STATION 927 BELOW FLOORBEAM. REMOVED CRACKED ANGLE, INSTALLED NEW ANGLE PER SRM 51-01.
- 14 May 2009
Pressure Panel, cracked
CRACK IN RIGHT WHEEL WELL PRESSURE DECK AT STATION 990 IN AREA OF FUEL LINE SHROUD. STOP DRILLED CRACK, INSTALLED TITANIUM DOUBLER PER AARD 53-30-00-13.
- 29 Apr 2009
Battery Pack, discharged
CEILING EMERGENCY LIGHTS ARE INOP FROM SEAT 7 TO 16. REMOVED AND REPLACED BATTERY PACKS IN RT BIN PER MM 33-60-98-4.
- 24 Apr 2009
Skin, damaged
LT ALT STATIC PORT, 7 INCH WAVINESS CHECK IS OUT OF LIMITS. INSTALLED DOUBLER PER SRM 51-30-2.
- 23 Apr 2009
Channel, cracked
NOSE LANDING GEAR WHEEL WELL C-CHANNEL IS CRACKED AT SPRAY DEFLECTOR GUIDE LT SIDE. REPAIRED PER AARD 53-10-00-4 REPAIR NR 4.
- 23 Apr 2009
Skin, dented
DENT IN FUSELAGE BETWEEN LONG 17L-18L. REPAIRED PER SRM 53-04 FIG 38 SHEET 30 VIEW P.
- 23 Apr 2009
Skin, dented
DENT IN FUSELAGE STA 333 ABOVE LONG 23L. INSTALLED DOUBLER PER SRM 53-04 FIG 38.
- 22 Apr 2009
Skin, dented
DENT IN FUSELAGE AT STA 254 AND LONG 18L-19L. INSTALLED DOUBLER PER SRM 53-04 FIG 12B.
- 21 Apr 2009
Skin, corroded
LT ALTERNATE STATIC PORT HAS CORROSION. INSTALLED NEW DOUBLER PER SRM 51-30-2.
- 21 Apr 2009
Cusp Web, cracked
RT CUSP CRACKED UNDER NUMBER 5 SEAT TRACK. CUT OUT CRACKED AREA AND INSTALLED DOUBLER PER 53-20-00-16.
- 16 Apr 2009
Skin, dented
DENT IN FUSELAGE AT RT STA 355 ABOVE LONG 21R. COLD WORK DENT AND INSTALLED DOUBLER PER SRM 53-04 FIG 38.
- 8 Dec 2005
Oil System, leaking
ORD - COMING IN FOR LANDING AT ABOUT 2000 FEET SMELLED AN UNIDENTIFIED ODOR. AFTER LANDING FLIGHT ATTENDANTS INFORMED CREW OF A LITE HAZY SMOKE IN THE CABIN.…
- 10 Oct 2004
Battery Pack, inoperative
DFW - AFT ENTRY OVERHEAD EMERGENCY LIGHTS INOPERATIVE. REPLACED BATTERY PACK B527 FOR AFT ENTRY OVERHEAD EMERGENCY LIGHTS. SYSTEM GROUND CHECKED NORMAL…
- 10 Oct 2004
Battery Pack, inoperative
DFW - TAIL CONE EMERGENCY LIGHT INOPERATIVE. REPLACED BATTERY PACK B527 FOR TAIL CONE EMERGENCY LIGHT. SYSTEM GROUND CHECKED NORMAL OPERATION.
- 27 Jan 2003
Frame, corroded
DURING CHECK-C, IN THE AFT CARGO COMPT FOUND BULKHEAD FRAME CORRODED AT STRINGER 1320, RBL 6, LBL 40. REMOVED OLD FRAME AND REPLACED PER SPM 6-70-01.
- 17 Jan 2003
Bracket, cracked
DURING CHECK-C CRACKED BRACKET FOR LOWER AFT DOOR STOP FORWARD CARGO DOOR. REPLACED BRACKET PER SRM 52-03.
- 16 Jan 2003
Door Frame, cracked
DURING CHECK-C MAINT FORWARD CARGO DOOR FORWARD SIDE AT SECOND DOOR STOP FROM BOTTOM PIN AREA CRACKED. INSTALLED DOUBLER REPAIR PER SRM 52-05 PAGE 291.
- 13 Jan 2003
Fitting, corroded
DURING CHECK-C MAINT IN THE FWD CABIN AT THE FWD SERVICE DOOR WAY, FOUND SILL BRACKET (GIRT BAR FITTING) CORRODED AT STA 172, RBL 53. REMOVED AND REPLACED…
- 13 Jan 2003
Web, corroded
DURING CHECK-C MAINT IN THE FWD ENTRY FOUND CORROSION ON WEB, BELOW FLOOR AT STA 168 TO 200, LBL 54. CLEANED AREA OF CORROSION. CUT OUT AREA BEYOND LIMITS AND…
- 13 Jan 2003
Bracket, corroded
DURING CHECK-C MAINT FOUND FWD SERVICE DOOR AFT SILL BRACKET CORRODED, STA 197 AND RBL 53. REPLACED BRACKET PER DOUGLAS DRAWING 9911516 AND SPM 6-70-01…
- 10 Jan 2003
Floor Support, corroded
DURING CHECK-C MAINT FOUND CORROSION ALONG FLOOR SUPPORT AT STA 148 TO 200, 8 INCHES RBL, UNDER NUMBER 4 FLOOR PANEL. INSTALLED NEW FLOOR SUPPORT, FABRICATED…
- 10 Jan 2003
Door Frame, cracked
DURING CHECK-C MAINT FOUND CRACK IN LOWER DOOR BEAM AT LOWER HINGE CUTOUT. FWD SERVICE DOOR. REPLACED FRAME PER SRM SPM 6-70-01.
- 10 Jan 2003
Floor Support, corroded
DURING CHECK-C MAINT IN THE FWD CABIN, FOUND CORROSION ALONG THE FLOOR SUPPORT AT STA 148 TO 200, 8 INCHES LBL, UNDER NUMBER 5 FLOOR PANEL. INSTALLED NEW…
- 8 Jan 2003
Floor Support, damaged
DURING CHECK-C MAINT FOUND CABIN FLOOR SUPPORT DAMAGED AT STA 905, LBL 12. REMOVED AND REPLACED FLOOR SUPPORT PER SPM 6-70-01.
- 7 Jan 2003
Floor Support, corroded
DURING CHECK-C IN THE CABIN A CORRODED FLOOR SUPPORT CAP WAS FOUND AT STA 1155, LBL 22 TO 44. REMOVED CORRODED CAP. CLEANED AREA AND INSTALLED NEW FABRICATED…
- 7 Jan 2003
Floor Support, corroded
DURING CHECK-C MAINT FOUND A CORRODED CABIN FLOOR SUPPORT CAP AT STA 1250, LBL 22 TO 44. REMOVED CORRODED CAP. CLEANED AREA AND FABRICATED AND INSTALLED NEW…
- 6 Jan 2003
Angle, cracked
DURING CHECK-C IN THE NLG WHEEL WHEEL A CRACK WAS FOUND ON RT SIDE OF NOSE GEAR WHEEL WELL JUST ABOVE THE RT FWD NOSE GEAR DOOR FWD HINGE, 8 INCHES AFT OF STA…
- 29 Sep 2002
Control Cable, out of rig
WHEN FLAPS EXTENDED TO 15 DEGREES THE SLAT DISAGREE LIGHT ILLUMINATED. DURING APPROACH SLAT DISAGREE LIGHT CONTINUED TO INTERMITTENTLY CHANGE BETWEEN OFF AND…
- 22 Jan 2002
Cable
FOUND FLAP BUS TRAVEL CABLE BROKEN. REPLACED THE CABLE. CHECK-C 8-25-01 STL. ---CLOSED---
- 22 Jan 2002
Cable
FOUND FLAP BUS TRAVEL CABLE BROKEN. REPLACED THE CABLE. CHECK-C 8-25-01 STL. --CLOSED--
- 28 Mar 2001
Light, inoperative
THE AFT ACCESSORY COMPT EMERGENCY LIGHTS WERE INOPERATIVE. REPLACED THE LAMPS. CHECK-C 9-8-00 STL.
- 28 Mar 2001
Battery, discharged
THE COCKPIT EMERGENCY FLOOD LIGHTS WERE INOPERATIVE. REPLACED THE BATTERIES. CHECK-C 9-8-00 STL.
- 8 Nov 2000
Wire, worn
THE FIRST CLASS FLOOR EGRESS LIGHTS WERE INOPERATIVE. REPAIRED WIRING, WORN DUE TO WEAR AND TEAR. CHECK-C 9-8-00 STL.
- 31 May 2000
Gyro, failed
DURING CRUISE, F/O''S RMI AND CAPT''S HSI BECAME ERRATIC THEREAFTER VG NUMBER 1 FAILED AND WOULD NOT RESET. REPLACED VG (PN 19911-C1) (S/N 45145) AND DG (P/N…
- 13 Aug 1999
Intercostal, cracked
DURING OP 16 MAINT CHECK, FOUND AFT CARGO COMPT TRACK SUPPORT INTERCOSTAL CRACKED AND CORRODED AT STA 1309, LONGERON 27R TO 28R. REMOVED INTERCOSTAL AND…
- 11 Aug 1999
Support, corroded
DURING OP 16 MAINT CHECK, THE CABIN O/B FLOOR SUPPORT RAIL WAS CORRODED AT STA 160 TO 198 AT FWD GALLEY DOOR. REMOVED THE CORROSION BY REPLACEMENT OF THE PART…
- 11 Aug 1999
Support, corroded
DURING OP 16 MAINT CHECK, FOUND CABIN FLOOR SUPPORT CORRODED AT STA 198, RBL 9 TO RBL44. FABRICATED ANGLE FROM 7075 T-6 PER SPM 6-70-01.
- 10 Aug 1999
Seat Track, corroded
DURING OP 16 MAINT CHECK, FOUND CORROSION ON CHAIR TRACK FLANGE AT STA 1212 TO 1250, LBL 44. REPLACED CHAIR TRACK PER SPM 6-70-01.
- 10 Aug 1999
Seat Track, corroded
DURING OP 16 MAINT CHECK, FOUND CORROSION ON CHAIR TRACK FLANGE, STA 1271 TO 1307, LBL 44. REPLACED CHAIR TRACK PER SPM 6-70-01.
- 10 Aug 1999
Intercostal, corroded
DURING OP 16 MAINT CHECK, FOUND IN AFT CARGO COMPT AT STA 1212 TO 1216, INTERCOSTAL BETWEEN LONGERONS 29R AND 30 WITH CORROSION ON FOOT. REMOVED AND RELACED…
- 10 Aug 1999
Support, corroded
DURING OP 16 MAINT CHECK, FOUND CORROSION ON CABIN FLOOR SUPPORT, STA 200, OTBD OF CHAIR TRACK AT RBL 44. REMOVED AND REPLACED SUPPORT MEMBER PER SPM 6-70-01,…
- 4 Aug 1999
Intercostal, corroded
DURING OP 16 MAINT CHECK, FOUND STA 1212 TO 1216 LONGERON 29R INTERCOSTAL CORRODED. REMOVED CORROSION BY REPLACEMENT OF PART PER SRM 51-10-3.
- 11 Oct 1998
Battery Pack, discharged
DURING MAINT CHECK, FOUND EMERGENCY CEILING LIGHT INOPERATIVE AT CABIN ROWS 9 AND 11. REPLACED BATTERY PACK. CHECK-C 7-28-98 MCI.
- 11 Oct 1998
Battery Pack, discharged
DURING MAINT CHECK, FOUND EMERGENCY CEILING LIGHT INOP AT AFT LAVS. REPLACED BATTERY PACK. CHECK-C 7-28-98 MCI.
- 22 Jul 1998
Connector, shorted
DURING CHECK-C MAINTENANCE, WHILE OPERATING THE AUX HYD PUMP THE ELECTRICAL CONNECTOR ON THE PUMP SHORTED, BURNING THE CONNECTOR CONTACTS AND CAUSING A SMALL…
- 7 Jun 1998
Hyd Fluid, lost
STL - FLT 203 - DURING TAKEOFF, LOST RT SYSTEM HYDRAULIC FLUID. REPLACED RT NOSE TIRE MFG PN 3910097-535 DUE TO TREAD CAP MISSING. CC-010 7-20-97 LAX. (X)
- 19 Mar 1998
Generator, worn
JFK - FLT 8703 - THE LEFT GEN FAILED, NO VOLTS OR FREQS. APU STARTED AND RAN NORMALLY FOR 30 MINUTES THEN APU GEN FAILED, NO VOLTS OR FREQS RETURNED TO JFK.…
- 27 Nov 1997
Blanket, out of position
PBI - FLT 229 - DURING CLIMB, TAIL COMPARTMENT HIGH LIGHT CAME ON. FOLLOWED HANDBOOK PROCEDURES AND LIGHT WENT OUT AFTER ENGINE POWER REDUCTION, BUT CAME ON…
- 27 Nov 1997
Duct, cracked
PBI - FLT 229 - DURING CLIMB, HAD A RECURRENCE OF TAIL COMPARTMENT HIGH LIGHT ILLUMINATION. LIGHT WENT OUT WITH POWER REDUCTION. REPAIRED RIGHT AND LEFT PACK…
- 22 Aug 1997
Detector, worn
LAX - FLT 40 - DURING CLIMB, THE NR 1 ENGINE, 'B' LOOP FIRE DETECTION LIGHT ILLUMINATED. REMOVED AND REPLACED THE DETECTOR LOOP MFG P/N 5938323-507,…
- 13 Aug 1997
Smoke Detector, failed
MCI - FLT 192 - DURING CLIMB, THE LEFT AFT LAV SMOKE DETECTOR ACTIVATED. REMOVED AND REPLACED SMOKE DETECTOR, MFG PN 72-130002-001, MANUFACTURED BY FENWAL…
- 29 Jul 1997
Clamp, loose
SFO - FLT 136 - DURING CLIMB, TAIL COMPARTMENT HIGH TEMPERATURE LIGHT ILLUMINATED. REPOSITIONED AND TIGHTENED CLAMPS ON AUGMENTATION VALVE. OPERATIONAL AND…
- 19 Feb 1997
Acm, failed
STL - DURING CLIMB, LEFT AIR CYCLE MACHINE (ACM) FAILED. REMOVED AND REPLACED LEFT ACM, MFG P/N 204950-5-4. FUNCTIONAL CHECK NORMAL. (M)
- 22 May 1996
Power Supply, inoperative
STL - DURING PREFLIGHT, EGRESS LIGHT IN FIRST CLASS DID NOT FUNCTION PROPERLY. FOUND POWER SUPPLY, MFG P/N 5822-2, MALFUNCTIONING. REPLACED POWER SUPPLY AND…
- 8 Mar 1996
Oil Line, ruptured
STL - FLT 712 - DURING CRUISE, SHUT DOWN NR 1 ENGINE, SN 3215, DUE TO OIL FILTER DIFFERENTIAL PRESSURE LIGHT ILLUMINATION. FOUND OIL LINE, MFG PN 7938314, TO…