N950AR
McDonnell Douglas MD-11F FAA →
earlier registrations
1 past record
service difficulty reports
18 reports
- 8 Jan 2016
Skin, delaminated
HIGH VIBRATION ON CLIMB CONTINUED FOR REMAINDER OF FLIGHT. FOUND RT WING NR 2 SPOILER DELAMINATED.
- 8 Jan 2016
Spoiler, delaminated
RETURNED TO DEPARTURE DUE TO HIGH STRUCTURE VIBRATION ON CLIMB PHASE PASSING 16,000 AND REMAINED FOR REST OF FLIGHT.
- 8 Dec 2014
Skin, dented
DURING POSTFLIGHT WALKAROUND, FOUND A DENT ON FUSELAGE FWD OF THE FWD CARGO DOOR. REPAIRED IAW STS EO 100-2014-114. ALL WORK DOCUMENTED ON NR 26850, 002651,…
- 2 Sep 2014
Pitot Line, contaminated
THE CREW REPORTED THAT DURING TAKEOFF, THERE WAS AN AIRSPEED DIFFERENCE AFTER 80KTS. THE F/O AIRSPEED INDICATOR DROPPED TO 55 KTS WHILE THE CAPTAIN’S AIRSPEED…
- 21 Jul 2014
Engine, making metal
ON REACHING TOP OF CLIMB, A LEVEL 2 OIL PRESSURE LOW DISPLAYED. CREW FOLLOWED THE QRH PROCEDURES SIMULTANEOUSLY FOLLOWING THE QRH PROCEDURES "ENGINE SHUTDOWN…
- 26 Jun 2014
Plate, corroded
DURING HEAVY CHECK, LT WING UPPER PLATE AT LWS 160 AND S15L WAS FOUND TO BE CORRODED. DAMAGE REPAIRED IAW EO SLC-140317.
- 26 Jun 2014
Plate, corroded
DURING HEAVY MAINTENANCE, MAINTENANCE FOUND UPPER PLATING AROUND BS 1229 BETWEEN RBL 57 TO 78 CORRODED. REPAIRED IAW EO SLC-140609.
- 26 Jun 2014
Plate, corroded
DURING HEAVY CHECK, UPPER PLATING AROUND BS 1229 AROUND RBL 8 FOUND CORRODED. REPAIRED IAW EO SLC-140611.
- 26 Jun 2014
Floor Panel, damaged
DURING HEAVY CHECK, FLIGHT COMPARTMENT, MAIN DECK, AND LOWER CARGO COMPARTMENT FLOOR PANELS WERE FOUND DAMAGED. REPAIRED FLOOR PANELS IAW EO SLC-140313.
- 26 Jun 2014
Fitting, cracked
DURING HEAVY CHECK, MAIN DECK CARGO HANDLING SYSTEM, CENTERLINE RESTRAINT ASSY SIDE FITTINGS WERE FOUND CRACKED. R & R 38 EACH CENTERLINE RESTRAINTS SIDE…
- 22 Sep 2012
Hydraulic Line, broken
HYD NR 3 FAIL DURING CRUISE, FL380 20 MIN FROM SVMI. AIRCRAFT RETURNED TO AIRFIELD, LANDING NORMAL. MX FOUND PIPE ASSY BROKEN, TO HORIZONTAL STAB TRIM MOTOR…
- 14 Jul 2012
Pump, malfunctioned
NR 1 SYSTEM HYD FLUID LOSS. RETURNED TO AIRFIELD. LANDING NORMAL. REPLACED NR 1 ENGINE LEFT AND RIGHT EDHP'S IAW 29-11-20, HYD MANIFOLD IAW 29-12-30. RUN UP…
- 10 Jul 2012
Hydraulic System, low
DURING CRUISE, LEVEL 2 ALERT 'HYD SYSTEM NR 1 LOW" ILLUMINATED. A/C RETURNED TO DEPARTURE SITE, WITH NORMAL LANDING. MX SERVICED HYD SYSTEM NR 1 IAW 12-13-00,…
- 5 May 2012
Oil Filter, dirty
DURING CLIMB CREW CALLED AND REPORTED NR 3 ENG HAD HIGH OIL TEMP. AIRCRAFT RETURNED TO AIRFIELD, LANDING NORMAL. MX T/S OIL TEMP WRITE UP IAW MD11 FIM…
- 15 Apr 2012
O-Ring, cut
DURING CRUISE HYD 3 ELEV "OFF" LIGHT ON. HYD QTY CHECKED 4.2 GAL AND KEPT ON DROPPING TO BELOW 2.5 GALS. HYD 3 FAIL. DIVERTED TO VCP, LANDING NORMAL. MX FOUND…
- 27 Oct 2011
Transmitter, failed
AFTER TAKEOFF, DEFLECTED AILERON DISAGREE LIGHT CAME ON. FUEL DUMPED TO REACH APPROVED LANDING WT. AIRCRAFT RETURNED TO AIRFILED. LANDING NORMAL. MX FOUND…
- 30 Aug 2011
Cadc, unserviceable
AFTER TAKEOFF CAPT'S PRIMARY FLT DISPLAY LOST ALL AIRSPEED AND ALTITUDE INDICATIONS. ELEVATOR LOAD FEEL AND FLAP LIMIT OVERRIDE ILLUMINATED, CAUSED BY THE…
- 2 Nov 2010
Actuator, failed
DURING CLIMB/CRUISE LEVEL 2 ALERT "AIL DEFLECTOR DISAGREE" ILLUMINATED. QRH (QUICK REF HANDBOOK) PROCEDURES FOLLOWED, LIGHT REMAINED ON. AIRCRAFT DUMPED…