N949MA
2002 Raytheon Aircraft Company B200 standard FAA →
registration
- 2002
earlier registrations
2 past records
- 1989
service difficulty reports
10 reports
- 30 Jan 2010
Battery, discharged
DURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT…
- 15 Dec 2009
Battery Pack, activated
DURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT…
- 19 Nov 2009
Light, inoperative
DURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT…
- 22 Sep 2009
Battery Pack, inoperative
DURING A ROUTINE OVERNIGHT SERVICE CHECK, INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT…
- 1 Sep 2009
Battery Pack, inoperative
DURING A ROUTINE OVERNIGHT SERVICE CHECK, INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT…
- 20 Aug 2009
Battery, discharged
IT HAS BEEN REPORTED BY THE FLIGHT CREW THE EMERGENCY EVACUATION LIGHTING SYSTEM HAS BEEN FOUND TO BE DEFECTIVE. MAINTENANCE PERSONNEL REMOVED AND REPLACED…
- 25 May 2008
Battery Pack, failed
DURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT…
- 25 May 2008
Battery Pack, failed
DURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT…
- 25 May 2008
Battery, failed
DURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT…
- 9 Jul 2007
Line, leaking
APPROXIMATELY ONE HOUR INTO CRUISE FLIGHT COCKPIT OXYGEN BOTTLE STARTED LEAKING. DESCENDED TO FLIGHT LEVEL 250 AND SHUT OXYGEN VALVE PER MAINTENANCE CONTROL.…