N949FR
2006 Airbus A319-112 standard FAA →
registration
- 2006
service difficulty reports
46 reports
- 30 Jan 2020
Line, cracked
HYD GREEN RSVR LOW LEVEL. R&R #1 ENGINE HYDRAULIC LINE PER AMM 20-33-11-911-001A, IPC 29-11-06 FIGURE 02E ITEM 220. OPS AND LEAK CHECK OK ON ALL SYSTEMS, NO…
- 23 Oct 2019
Fitting, cracked
DISCREPANCY: REFERENCE PEMCO N/R: 2650N340 RH FR16 UPPER DOUBLE JOGGLE AREA FWD LOWER HOLE (C) SHOWS CRACK INDICATION IN THE MIDDLE LAYER AT 9 OCLOCK POS.…
- 23 Oct 2019
Fitting, worn
DISCREPANCY: REFERENCE PEMCO N/R: 2650N344 RH MLG DOOR AFT KEEL BEAM HINGE FITTING FWD LUG WORN TOTAL CYCLES 122,213 CORRECTIVE ACTION: REPAIRED R/H MLG DOOR…
- 23 Oct 2019
Fitting, cracked
DISCREPANCY: REFERENCE PEMCO N/R: 2650N341 RH FR16 UPPER DOUBLE JOGGLE AREA AFT LOWER HOLE (BL SHOWS CRACK INDICATION IN THE INBD LAYER AT 9 OCLOCK POS.…
- 23 Oct 2019
Hinge Fitting, worn
DISCREPANCY: REFERENCE PEMCO N/R: 2650N343 LH MLG DOOR AFT KEEL BEAM HINGE FITTING FWD LUG WORN CORRECTIVE ACTION: REPAIRED L/H MLG DOOR AFT KEEL BEAM, HINGE…
- 22 Oct 2019
Structure, cracked
DISCREPANCY: REFERENCE PEMCO N/R# 2650N260 L/H EMERG EXIT DOOR, FWD, INNER SEGMENT (SEGMENT #1 FWD) HAS CRACK INDICATIONS. CORRECTIVE ACTION: FAVRICATED &…
- 22 Oct 2019
Structure, cracked
DISCREPANCY: REFERENCE PEMCO N/R# 2650N261 R/H EMERG EXIT DOOR, FWD, INNER SEGMENT (SEGMENT #1 FWD) HAS CRACK INDICATIONS. CORRECTIVE ACTION: FAVRICATED &…
- 16 Aug 2018
Unknown, odor
NOTICED A FOUL ODOR COMING FROM AFT GALLEY AND LAST ROWS.THE ODOR WENT AWAY AND CAME BACK. PERFORMED TROUBLESHOOTING IAW TSM 05-50-00-810-831-A. RAN PACKS NR…
- 28 Jul 2018
Door, misaligned
MOVED LANDING GEAR LEVER TO UP POSITION AFTER TAKEOFF. GEAR DID NOT RETRACT. LANDING GEAR NOT UPLOCKED FAULT. PERFORMED QRH PROCEDURE. FAULT CLEARED. BOTH…
- 3 Dec 2017
Floorbeam, corroded
CABIN FLOOR BEAM Y+254 HAS CORROSION AT FR20. REMOVED AND REPLACED FLOOR BEAM Y+254 FR12 TO FR23 P/N D5311281820401 IAW SRM 51-42-11, 51-72-11-911-001 AND…
- 3 Dec 2017
Floorbeam, corroded
CABIN FLOORBEAM Y+1292 HAS CORROSION AT FR16-20. FLOORBEAM REMOVED AT FR16-20 FOUND TO BE OUT OF LIMITS IAW SRM 53-11-14-283-004 AND LOCATE AND DRILL IT IAW…
- 3 Dec 2017
Floorbeam, corroded
CABIN FLOORBEAM Y-1292 HAS CORROSION AT FR 20. REMOVED AND REPLACED FLOORBEAM Y-1292 AT FR 20 IAW SRM 51-42-11, 51-72-11-911-001 AND 53-11-14-283-004.
- 2 Dec 2017
Floorbeam, corroded
FLOORBEAM +512 CORRODED AT FR66-67. REMOVED AND REPLACED FLOORBEAM +512 LT SIDE IAW SRM 51-44-11, 51-72-11-911-001 AND 53-00-14-283-002.
- 2 Dec 2017
Door Sill, corroded
DISCREPANCY: L2 DOOR SILL CORRODED AT FR66. CORRECTIVE ACTION: REFERENCE PEMCO NR 177N259. REMOVED AND REPLACED L2 DOOR SILL IAW A319 SRM 51-72-11, 51-42-11…
- 2 Dec 2017
Door Sill, corroded
DISCREPANCY: R2 DOOR SILL CORRODED AT FR68. CORRECTIVE ACTION: REFERENCE PEMCO NR 1777N258. REMOVED AND REPLACED R2 DOOR SILL IAW A319 SRM 51-72-11, 53-41-14,…
- 1 Dec 2017
Threshold, corroded
FORWARD CARGO BAY DOOR CUT OUT LOWER SILL UPPER SIDE HAS CORROSION AROUND FASTENERS AND FASTENER HOLES, SEVERAL AREAS. REMOVED AND INSTALLED A NEW WEB IAW SRM…
- 22 May 2017
Battery, discharged
EPSU BATTERY 12WL RIGHT FAULT. FAILS TEST. REMOVED AND REPLACED BATTERY ASSEMBLY 12WL RIGHT. REFERENCE AMM 33-51-38-000-002A AND AMM 22-51-38-400-002A. EPSU…
- 22 May 2017
Power Supply, inoperative
DURING EMERGENCY LIGHT TEST L1 EPSU INOPERATIVE. REMOVED AND REPLACED EPSU 10WL FWD. OPERATIONAL CHECK OK. REFERENCE AMM 33-51-38 PAGE BLOCK 401.
- 27 Apr 2016
Fitting, out of adjust
DEFECT 1047578, DURING CRUISE THE R2 DOOR PRESS LIGHT WARNING INDICATION CAME ON & SLIDE INDICATION WENT OUT ON ECAM DOOR PAGE. ADJUSTED THE R2 DOOR GIRT BAR…
- 18 Apr 2016
Door Sill, corroded
DURING C6 C CHECK NON ROUTINE INSPECTION NOTED THE R2 DOOR SILL HAS AREAS OF CORROSION BETWEEN FRAME 67 & 68. REPAIRED R2 DOOR SILL PLATE BETWEEN FRAME 67 &…
- 17 Apr 2016
Shear Plate, cracked
DURING C6 C CHECK NON ROUTINE INSPECTION NOTED LT LATERAL SHEAR PLATE, BETWEEN FRAME 69 & 70 CRACKED. R & R NEW SHEAR PLATE & SHEAR PLATE SUPPORT ON LT SIDE…
- 17 Apr 2016
Floorbeam, corroded
DURING C6 C CHECK NON ROUTINE INSPECTION NOTED CORROSION ON FLOORBEAM Y512 ON FRAME 66 ON HARD POINT. R & R FLOORBEAM Y512 ON FRAME 66 IAW SRM AT FRAME 64 &…
- 16 Apr 2016
Shear Plate, corroded
DURING C6 C CHECK NON ROUTINE INSPECTION NOTED RT LATERAL SHEAR PLATE BETWEEN FRAME 69 & 70 CORRODED. R & R RT LATERAL SHEAR PLATE IAW SRM 51-42-11.
- 15 Apr 2016
Floorbeam, corroded
DURING C6 C CHECK NON ROUTINE INSPECTION NOTED AREAS OF CORROSION FOUND ON Y1292, BETWEEN FRAME 66 & 68. R & R NEW Y1292 IAW SRM 52-42-11.
- 14 Apr 2016
Floorbeam, corroded
DURING C6 C CHECK NON ROUTINE INSPECTION, NOTED CORROSION AT FLOORBEAM Y765M, AT FRAME 66 & 68. R & R FLOORBEAM BETWEEN FRAME 66 & 77 IAW SRM 51-42-11.
- 10 Apr 2016
Floorbeam, corroded
DURING C6 CHECK NON ROUTINE NR 779N175 INSPECTION NOTED SEVERAL AREAS OF CORROSION FOUND ON Y765 FLOORBEAM, BETWEEN FRAME 66 & 68. R & R FLOORBEAM IAW SRM…
- 8 Feb 2014
Light, inoperative
SEAT 4C EMERGENCY PATH LIGHT INOPERATIVE. R & R SEAT 4C EMERGENCY PATH LIGHT IAW AMM 33-51-19 PB401, OPERATIONS CHECKED GOOD.
- 17 Sep 2012
Light, burned out
C-CHECK: R2 DOOR "SLIDE ARMED" LIGHT DOES NOT ILLUMINATED DURING TEST. REMOVED SLIDE ARMED INDICATOR LIGHT ASSY IAW AMM 52-76-000-002-A. INSTALLED SERVICEABLE…
- 17 Sep 2012
Sill, corroded
C-CHECK: R2 DOOR SILL BEAM CORRODED AROUND FASTENER HOLE AT FRAME 66. REPAIRED DOOR SILL BEAM WITH CUTOUT, FILLER AND SPLICE IAW SRM 53-41-14 PB201, PARA 5.A,…
- 17 Sep 2012
Lamp, burned out
C-CHECK: MAIN CABIN LT SEATS, ROW 13 HAS BURNED OUT LAMP FOR EMERGENCY EXIT LIGHT. R & R LAMP IAW AMM 33-51-19-420-052D. OPS CHECKED GOOD LAW AMM 33-51-00-71…
- 10 Sep 2012
Shear Plate, corroded
C-CHECK; FRAME 69 RT SIDE SHEAR PLATE CORROSION. R & R SHEAR PLATE IAW EO A0-53EO-31434.
- 10 Sep 2012
Shear Plate, corroded
C-CHECK: FRAME 69 LT SIDE SHEAR PLATE CORROSION. R & R SHEAR PLATE EO A0-53EO-31434.
- 10 Sep 2012
Frame, corroded
C-CHECK: FRAME 68-1292, RM 51-42-11, PARA 5 AND SRN 53-00-14 PB 101B.
- 10 Sep 2012
Floorbeam, corroded
C-CHECK: FLOORBEAM CORRODED IN TWO AREAS. R & R FLOORBEAM IAW SRM 51-42-11, PARA 5 AND SRM 53-00-14, PB 101 B.
- 10 Sep 2012
Sill, corroded
C-CHECK: LT SIDE DOOR SILL BEAM CORROSION AROUND FASTENER HOLE. REPAIRED IAW REF SRM 53-41-14 PB 201, NOTE 1.
- 10 Sep 2012
Floorbeam, corroded
C-CHECK: BS 1292 FLOORBEAM CORROSION. R & R FLOORBEAM IAW SRM 51-42-11 PAR 5 AND SRM 53-00-14, PB 101, B. (2), FIGURE 102.
- 13 May 2011
Floorboard, damaged
C-CHECK: COCKPIT FLOORBOARD, 211GF SURFACE IS DAMAGED. FOUND DAMAGE TO FLOORBOARD, 211GF BEYOND REPAIRABLE LIMITS. REPLACED FLOORBOARD IAW SRM 53-12-00 IAW…
- 11 Apr 2011
Floorbeam, corroded
C-CHECK: NON ROUTINE NR 30063; FLOORBEAM ON FRAMES 66- 68 HAS CORROSION AT FASTENER HOLES, BLENDED CORROSION, MEASURED OUT OF LIMITS. ORIGINAL THICKNESS…
- 11 Apr 2011
Floorbeam, corroded
C-CHECK: NON ROUTINE 30064; FLOORBEAM ON FRAMES 66-68 HAS CORROSION AT FASTENER HOLES, BLENDED CORROSION, MEASURED OUT OF LIMITS. ORIGINAL THICKNESS .100",…
- 11 Apr 2011
Spar, dented
C-CHECK: NON ROUTINE NR30121; RT WING L/E STA 7792/RIB 14 IS DENTED WITH INTERNAL DAMAGE AT CLOSEOUT WEB. REPAIRED RIGHT WING L/E DAMANGE STATION 7792/RIB 14…
- 14 Jun 2010
Oil System, leaking
REF LOG PAGE 522934. ITEM 1. FOUL ODOR EMITS FROM PACKS WITH BOTH APU AND ENGINE BLEEDS. FOUND APU OIL LEAKING INTO BLEED AIR. APU RENDERED INOPERATIVE. APU…
- 21 Dec 2009
Control Panel, deactivated
REFERENCE LOG PAGE 489469. DURING FLIGHT THE CREW NOTED THE AFT F/A PANEL HAD NO POWER AND COULD NOT MANUALLY TURN ON EMERGENCY LIGHTING FROM AFT PANEL. MX…
- 4 Aug 2009
Grommet, unsecure
DURING C2 C-CHECK, INSP NOTED THE GUSTLOCK ON THE R1 DOOR DOES NOT ENGAGE WITH THE DOOR IN THE FULL OPEN POSITION. MX FOUND THE NYLON GROMMET ON GUSTLOCK…
- 25 Feb 2008
Epsu, inoperative
DURING C1 C CHECK, INSPECTION REPORTED THE OPERATIONAL TEST OF THE EMERGENCY LIGHTS FAILED WITH A FAULT MESSAGE OF "EPSU (13WL) AFT L/DEU B." MAINTENANCE…
- 23 Feb 2008
Floor Panel, damaged
DURING C1 C CHECK, INSPECTION REPORTED AFT CARGO PIT FLOOR PANEL 151ZG WAS DAMAGED BEYOND REPAIRABLE LIMITS. MAINTENANCE REMOVED AND REPLACED THE FLOOR PANEL…
- 23 Feb 2008
Floor Panel, damaged
DURING C1 C CHECK, INSPECTION REPORTED AFT CARGO PIT FLOOR PANEL 151VG WAS DAMAGED BEYOND REPARABLE LIMITS. MAINTENANCE REMOVED THE FLOOR PANEL IN ACCORDANCE…