N934L
1983 Douglas DC-9-41 special flight permit FAA →
earlier registrations
1 past record
- 1983
service difficulty reports
8 reports
- 14 Jun 1998
Bulbs, failed
STL - DURING OVERNIGHT MAINTENANCE CHECK, FOUND OVERHEAD EMERGENCY LIGHTS INOPERABLE ON RT SIDE OF CABIN AT ROWS 24, 21, 12, AND 7. REPLACED BULBS AT ROWS 24,…
- 7 May 1997
Oil System, overserviced
STL - FLT 132 - DURING APPROACH WITH APU RUNNING, BOTH PACKS EMITTED SMOKE AND OILY ODOR. APU, MFG PN 5910050527, MANUFACTURED BY DOUGLAS AIRCRAFT CO.,…
- 20 Mar 1997
Warning Light, malfunctioned
STL - FLT 515 - DURING FLIGHT, LEFT HAND GEAR UNSAFE LIGHT REMAINED ON WITH GEAR LEVER UP. LIGHT REMAINED ON UNTIL GEAR DOWN AND GOT THREE GREEN INDICATORS.…
- 4 Mar 1997
Battery Pack, discharged
STL - DURING CRUISE, EMERGENCY EGRESS LIGHTS ILLUMINATED AT ROWS 1 THROUGH 7. REMOVED AND REPLACED BATTERY PACK, MFG P/N 5822-2. OPERATIONAL CHECK NORMAL. (M)
- 24 Feb 1997
Engine, oil loss
TLH - FLT 507 - DURING CLIMB NR 1 ENGINE, S/N 1601, WAS SHUT DOWN DUE TO OIL QUANTITY LOSS. CHANGED ENGINE. (M)
- 28 Oct 1996
Light, inoperative
STL - EMERGENCY ESCAPE PAHT LIGHTING ILLUMINATED DURING FLIGHT. CLEANED MOISTURE FROM LIGHT TRACK, OPERATIONAL CHECK NORMAL. (M)
- 23 May 1996
Duct, ruptured
BDL - DURING CLIMB SHUT DOWN NR 1 ENGINE, S/N 1607, DUE TO FIRE WARNING ON BOTH LOOPS. DISCHARGED FIRE EXTINGUISHER BOTTLE. FOUND ANTI-ICE HEAT DUCT, MFG P/N…
- 1 Apr 1996
Power Supply, inoperative
DURING CRUISE THE EMERGENCY EGRESS LIGHTS ILLUMINATED. REMOVED AND REPLACED THE POWER SUPPLY, MFG P/N 5822-2. OPERATIONAL CHECK NORMAL.