N9305N
2011 Cessna 172S standard FAA →
registration
- 2011
aircraft radio
earlier registrations
2 past records
- 1986
owner withheld at the FAA
service difficulty reports
50 reports
- 14 Aug 2004
Connector, shorted
INFLIGHT T1261 DFW SAT/14 AT 26,000 FEET LEVEL GOT AN INDICATION OF AFT CARGO FIRE. FOLLOWED QRH AND BOTH BOTTLES FIRED. LANDED WITHOUT INCIDENT. REPLACED NR…
- 26 Dec 2002
Valve, defective
NOSE GEAR STRUT FLAT NOT ALLOWING GEAR TO RETRACT. REMOVED AND REPLACED SCHRADER VALVE AND RESERVICED STRUT.
- 23 Dec 2002
Seal, loose
BOTH HEAT EXCHANGERS LEAKING NOT ALLOWING AIRCRAFT TO PRESSURIZE. TIGHTENED SEALS ON BOTH HEAT EXCHANGERS.
- 8 Oct 2002
Power Supply, discharged
THE EGRESS LIGHTING BETWEEN ROWS 15 TO 21 WERE FLASHING ON AND OFF DURING FLIGHT. REPLACED THE POWER SUPPLY.
- 11 Jun 2002
Fitting, cracked
DURING CHECK-C MAINT THE FORMER FOOT WAS CRACKED AT STA 1361 BETWEEN LONGERON 23L AND 24L. FABRICATED AND INSTALLED NEW FORMER FOOT SECTION PER SPM 6-70-01,…
- 5 Jun 2002
Floorbeam, damaged
DURING CHECK-C MAINT THE FLOOR BEAM CAP WAS GROUND BEYOND LIMITS AT STA 1322, LBL 34. REPAIRED FLOOR BEAM CAP PER SRM 53-05, FIG 20A.
- 4 Jun 2002
Tie Clip, cracked
DURING CHECK-C CRACKED TIE CLIP AT STA 1437 VERT BULKHEAD TO LONG 3R. REPLACED TIE CLIP PER SPM 6-70-01.
- 22 May 2002
Floorbeam, corroded
DURING CHECK-C MAINT FOUND CORROSION IN LATERAL FLOOR BEAM AT STA 180, FROM RBL 8 TO RBL 43. FABRICATED AND INSTALLED FLOOR SUPPORT PER SRM 51-01, PAGE 1 ITEM…
- 17 May 2002
Door Frame, cracked
DURING CHECK-C MAINT THE RT FWD GALLEY SERVICE DOOR HAD A CRACKED DOUBLER LOWER HINGE ARM. REPLACED WITH NEW FRAME PART PER SPM 6-70-01.
- 17 May 2002
Stringer, cracked
DURING CHECK-C MAINT STRINGER 3 LT WAS CRACKED AT STA 160, ABOVE ELECT PANEL. REPAIRED LONGERON 3 PER SRM 53-02, FIG 18.
- 16 May 2002
Longeron, cracked
DURING CHECK-C MAINT THE NUMBER 4 LT LONGERON WAS CRACKED AT STA 160. REPLACED DAMAGED SECTION OF LONGERON PER SRM 53-02, FIG 18.
- 25 Nov 2001
Wire, broken
DURING PREFLIGHT INSPECTION IT WAS NOTED THE RH MID ZONE EGRESS LIGHTS WERE INOP. REPAIRED BROKEN WIRE AT ROW 16 RH SIDE.
- 25 Nov 2001
Wire, broken
DURING PREFLIGHT INSPECTION IT WAS NOTED THE RH MID ZONE EGRESS LIGHTS WERE INOP. REPAIRED BROKEN WIRE AT ROW 16 RT SIDE.
- 25 Aug 2001
Battery Pack
THE CABIN OVERHEAD EMERGENCY LIGHTS ILLUMINATED WHEN POWER WAS REMOVED FROM THE AIRCRAFT. REPLACED THE BATTERY PACK. CHECK-C 5-7-01 STL. --CLOSED--
- 17 Aug 2001
Lamp
DURING LANDING THE RIGHT MAIN LANDING GEAR LIGHT DID NOT ILLUMINATE, DUE TO BURNED OUT BULB. REPLACED LIGHT BULB P/N 387.LAST CHECK C 05/07/01 STL. --- CLOSED…
- 4 Aug 2001
Battery Pack, discharged
DURING MAINTENANCE THE AFT FLOOR EGRESS LIGHTS WERE INOP DUE TO WEAR. REPLACED BATTERY PACK P/N5822-2 AND FEEDER JUMPER CABLE PER MM 33-51-01.
- 8 Jun 2001
Battery Pack, discharged
IN FLIGHT THE EGRESS LIGHTS AT ROWS 15 TO 22 ILLUMINATED. REPLACED THE BATTER PACK. CHECK-C 5-7-01 STL.
- 2 Jun 2001
Power Supply, discharged
AN OVERWING EMERGENCY EXIT LIGHT REMAINED ON IN FLIGHT. REPLACED THE POWER SUPPLY. CHECK-C 5-7-01 STL.
- 24 May 2001
Battery, discharged
THE EGRESS LIGHTING IN THE FIRST CLASS CABIN WAS INOPERATIVE. REPLACED THE BATTERIES IN THE BATTERY PACK. CHECK-C 5-7-01 STL.
- 9 Apr 2001
Wire, broken
THE AFT CABIN EXIT IDENTIFIER FAILED TO ILLUMINATE. REPAIRED A BROKEN WIRE IN CEILING OF AFT LEFT LAVATORY. CHECK-C 2-5-01 JFK.
- 20 Jun 2000
Frame, cracked
DURING CHECK-C MAINT, THE FAIRING SUPPORT FRAME WAS CRACKED AT STA 946, RBL 7 AND LBL 7. REPAIRED BOTH PER SRM 53-05, FIG 81, PAGE 267.
- 16 Jun 2000
Floorbeam, corroded
DURING CHECK-C MAINT, THE FLOORBEAM WAS CORRODED AT STA 1323, LBL 22. REPAIRED FLOORBEAM PER SRM 53-05 PAGE 31 FIG 20A.
- 13 Jun 2000
Floorbeam, corroded
DURING CHECK-C MAINT, FOUND CORROSION ON FLOORBEAM AT STA 1309, LOCATED 6 INCHES LEFT OF CENTER LINE. REMOVED AND REPLACED FLOOR SUPPORT. USED TWA (P/N…
- 13 Jun 2000
Skin, corroded
DURING CHECK-C MAINT, THE SURFACE AT LE AT TELESCOPING ANTI-ICE DUCT, 0.045 IN MATERIAL WAS REMOVED FOR CORROSION REMOVAL. MATERIAL THICKNESS IS 0.250 IN PER…
- 12 Jun 2000
Web, corroded
DURING CHECK-C MAINT, THE MEMBRANE AT LONGERON 18L BETWEEN STATION 218 TO 237, O/B OF CHAIR TRACK, WAS CORRODED. FABRICATED NEW PART PER DRAWING 5930544 AND…
- 12 Jun 2000
Attach Angle, cracked
DURING CHECK-C MAINT, THE ATTACH ANGLE ON BOTTOM OF DORSAL FIN CRACKED THROUGH THE SCREW HOLE, LT SIDE APROX STA 1420. INSTALLED REPAIR ANGLE PER SRM 53-01…
- 12 Jun 2000
Frame, corroded
DURING CHECK-C MAINT, FOUND FORMER RING AT STA 1309 CORRODED BETWEEN LONGERONS 29L AND 29R. REMOVED CORROSION PER SPM 6-80-01. TRIMMED CORRODED AREA OVER…
- 11 Jun 2000
Attach Angle, cracked
DURING CHECK-C MAINT, THE RT DORSAL FIN ATTACH ANGLE ON FUSELAGE STA 1420 WAS CRACKED. INSTALLED NEW ANGLE PER DOUGLAS DRAWING 174968, PER SPM 6-70-01 WITH…
- 11 Jun 2000
Seat Track, corroded
DURING CHECK-C MAINT, FOUND INTERGRANULAR CORROSION ON NUMBER 4 CHAIR TRACK, RBL 22 INCHES, STA 1144. INSTALLED SPLICE REPAIR PER SRM 53-05, FIG 4F.
- 11 Jun 2000
Structure, damaged
DURING CHECK-C MAINT, FOUND CLASS 3 REPAIR AT STA 200 TO 225, LONGERON 4L TO 6L. REPAIRED PER SRM 53-04 FIG 12B, SHEETS 9 AND 10. MESSAGE SENT TO ENGINEERING…
- 8 Jun 2000
Seat Track, corroded
DURING CHECK-C MAINT, NUMBER 3 CHAIR TRACK FROM STA 1031 TO 1309 HAD CORROSION BEYOND LIMITS. REPLACED NUMBER 3 CHAIR TRACK PER IPC 53-40-00 FIG 19B AND SRM…
- 8 Jun 2000
Floorboard, corroded
DURING CHECK-C MAINT, FOUND CORROSION ON CABIN FLOOR PANEL SUPPORT AT STA 200, BL 0 TO RBL 50. REMOVED CORROSION PER SPM 6-80-1. REPLACED SUPPORT EXTRUSION…
- 8 Jun 2000
Seat Track, corroded
DURING CHECK-C MAINT, CABIN STA 1155 LRL 47 HAD CORROSION ON TRACK NUMBER 2. REPLACED TRACK SECTION PER SRM 53-05, FIG 4F.
- 7 Jun 2000
Floorbeam, corroded
DURING CHECK-C MAINT, FOUND CORROSION ON CABIN FLOORBEAM, LEFT AFT LAV STA 1338, 20 INCH LBL AND 30 IN LBL. CORROSION REMOVED PER SPM 6-80-01 PAGE 31 TO 42,…
- 7 Jun 2000
Spar, corroded
DURING CHECK-C MAINT ON THE RT WING, CORROSION WAS FOUND ON THE REAR SPAR BETWEEN CENTER AND O/B AILERON HINGE. FABRICATED ACCORDING TO SRM 59-09 FIG 5.…
- 6 Jun 2000
Bracket, cracked
DURING CHECK-C MAINT, A FUSELAGE ANGLE BRACKET WAS CRACKED AT STA 946, LBL 7 INSIDE KEEL BEAM LOWER FWD CORNER. FABRICATED PART FROM 7075-T6 PER SPM AND PRINT…
- 6 Jun 2000
Frame, corroded
DURING CHECK-C MAINT, THE AFT CARGO BIN HAD CORROSION ON FORMER RING AT STA 1271, LONGERON 30. AT STA 1271 ON FORMER RING AT LONGERON 30 REMOVED CORROSION PER…
- 6 Jun 2000
Seat Track, worn
DURING CHECK-C MAINT, THE FIRST OFFICER''S RT FWD CHAIR TRACK WAS WORN ON UPPER AND LOWER SURFACES. REPLACED FLOOR TRACK PER MM 53-40-01 PAGE 203.
- 5 Jun 2000
Floor Support, corroded
DURING CHECK-C MAINT AT CABIN STA 1155, LBL 33, FOUND CORROSION ON FLOOR SUPPORT BETWEEN NUMBER 2 AND 3 TRACKS. FABRICATED AND INSTALLED NEW SUPPORT PER SRM…
- 5 Jun 2000
Stiffener, cracked
DURING CHECK-C MAINT AT STA 996 BODY FAIRING STIFFENER BOTTOM CORD HAD A 6.5 INCH CRACK AND THE REPAIR ANGLE HAD 1.5 INCH CRACK. STOP DRILLED CRACKS PER SRM…
- 4 Jun 2000
Floorbeam, corroded
DURING CHECK-C MAINT, FOUND CABIN MEMBRANE CORRODED AT STA 503 TO 522, LONGERON 18L. REMOVED CORRODED AREA AND INSTALLED DOUBLER PER SRM 53-01, PAGE 9.
- 1 Jun 2000
Strap, corroded
DURING CHECK-C MAINT, THE RT WING UPPER O/B SPOILER, O/B END, TRAILING EDGE SUPPORT STRAP HAD CORROSION. REMOVED DAMAGED SUPPORT STRAP AND REPLACED WITH NEW…
- 28 Oct 1999
Battery, discharged
DURING PREFLIGHT, FOUND OVERHEAD EMERGENCY LIGHTS INOP AT ROWS 28L AND 28R THROUGH ROWS 26L AND R AND 5 EACH INOP IN THE TAIL SECTION. REPLACED BATTERY. AC01…
- 6 Sep 1998
Coalescer Bag, dirty
STRONG ODOR WITH SMOKY HAZE IN COCKPIT AND CABIN AFTER TAKEOFF. FLT RETURNED TO SFO. CHECKED ALL ACFT COMPARTMENTS, CHECKED APU CHECK VALVE, AND ACM OUTLETS…
- 27 Mar 1998
Coalescer, dirty
LGA - FLT 293 - AFTER TAKEOFF SMOKE FILLED CABIN AND COCKPIT WITH ODOR AND LIGHT HAZY SMOKE. FLIGHT RETURNED TO LGA. FOUND AIR COND PACK COALESCER BAGS…
- 13 Jun 1997
Skin, gouged
MCI - DURING C-CHECK MAINTENANCE FOUND A DEEP GOUGE ON LEFT SIDE OF FUSELAGE, LONGERON 18 TO 26, STATION 1211 TO 1338. REPLACED SKIN PANEL, LONGERON 18 TO 26,…
- 13 Jun 1997
Skin, gouged
MCI - DURING OP 16 MAINTENANCE CHECK, FOUND GOUGE IN SKIN PANEL AT LONGERON 22, STATION 1211 TO 1117. REPAIRED SKIN PANEL PER SRM 53-04, FIG 12B. (M)
- 8 Mar 1997
Skin, damaged
STL - DURING SPECIAL CHECK, FOUND DAMAGE ON LEFT AFT FUSELAGE, AFT OF FLAP. REPAIRED PER ARA 11135A AND SRM 53-04. (M)
- 2 Jun 1996
Schrader Vlv, failed
MSY - AFTER TAKEOFF WHEN LANDING GEAR WAS RETRACTED, NOSE LANDING GEAR DID NOT RETRACT. FOLOWED ORH PROCEDURES. FOUND NOSE LANDING GEAR STRUT DEFLATED AND A…
- 23 May 1996
Coalescer Bag, dirty
MCI - FLT 667 - DURING CLIMB WHEN ENGINE ANTI-ICE WAS TURNED ON, A BURNING ODOR WAS NOTICED IN THE CABIN. TURNED OFF ENGINE ANTI-ICE. FOUND DIRTY COALESCER,…