N919AX
Nihon YS-11A-500 FAA →
earlier registrations
1 past record
service difficulty reports
48 reports
- 5 Mar 1996
Engine, failed
NR 2 ENGINE FAILED IN-FLIGHT. REPLACED NR 2 ENGINE. NOTE: NO TEAR-DOWN FINDINGS AVAILABLE AT THIS TIME ON FAILED ENGINE.
- 4 Jan 1996
Latch Mech, iced up
DURING DESCENT CHECKLIST WITH LANDING GEAR HANDLE PLACED TO NEUTRAL, HYDRAULIC LEVER DEPRESSED AND NOSE LANDING GEAR EXTENDED. TRIED SEVERAL TIMES AND NOSE…
- 11 Nov 1995
Support, damaged
DURING C-CHECK, THE LONGITUDINAL FLOOR SUPPORT BETWEEN STA 5640 AND 6120 RBL 300 WAS FOUND DAMAGED. REPAIRED IAW REA Y153-13320-MR.
- 10 Nov 1995
Floorbeam, corroded
DURING C-CHECK, CORROSION WAS FOUND ON A FLOORBEAM AT STA 8080. REPAIRED IAW REA Y153-13321-MR.
- 10 Nov 1995
Floorbeam, corroded
DURING C-CHECK, CORROSION WAS FOUND ON A FLOORBEAM AT STA 8080. REPAIRED IAW REA Y153-13322-MR.
- 10 Nov 1995
Support, corroded
DURING C-CHECK, THE LONGITUDINAL FLOOR SUPPORT BETWEEN STA 840 AND 8080 RBL 300 WAS FOUND CORRODED. REPAIRED IAW REA Y153-13320-MR.
- 10 Nov 1995
Support, corroded
DURING C-CHECK, THE LONGITUDINAL FLOOR SUPPORT BETWEEN STA 1320 AND 5160 RBL 1180 WAS FOUND CORRODED. REPAIRED IAW REA Y153-13320-MR.
- 9 Nov 1995
Floorbeam, corroded
DURING C-CHECK, THE FLOORBEAM AT STA 7080 WAS FOUND CORRODED. REPAIRED IAW REA Y153-13320-MR.
- 8 Nov 1995
Floorbeam, corroded
DURING C-CHECK, CORROSION WAS FOUND ON A FLOORBEAM AT STA 3240. REPAIRED IAW REA Y153-13321-MR.
- 8 Nov 1995
Floorbeam, corroded
DURING C-CHECK, CORROSION WAS FOUND ON A FLOORBEAM AT STA 7580. REPAIRED IAW REA Y153-13322-MR.
- 8 Nov 1995
Floorbeam, corroded
DURING C-CHECK, CORROSION WAS FOUND ON A FLOORBEAM AT STA 7580. REPAIRED IAW REA Y153-13322-MR.
- 7 Nov 1995
Floorbeam, corroded
DURING C-CHECK, CORROSION WAS FOUND ON A FLOORBEAM AT STA 9180. REPAIRED IAW REA Y153-13321-MR.
- 7 Nov 1995
Floorbeam, corroded
DURING C-CHECK, CORROSION WAS FOUND ON A FLOORBEAM AT STA 840. REPAIRED IAW REA Y153-13321-MR.
- 7 Nov 1995
Floorbeam, corroded
DURING C-CHECK, CORROSION WAS FOUND ON A FLOORBEAM AT STA 1080. REPAIRED IAW REA Y153-13321-MR.
- 7 Nov 1995
Floorbeam, corroded
DURING C-CHECK, CORROSION WAS FOUND ON A FLOORBEAM AT STA 1800. REPAIRED IAW REA Y153-13321-MR.
- 6 Nov 1995
Floorbeam, corroded
DURING C-CHECK, CORROSION WAS FOUND ON A FLOORBEAM AT STA 2280. REPAIRED IAW REA Y153-13321-MR.
- 6 Nov 1995
Floorbeam, corroded
DURING C-CHECK, CORROSION WAS FOUND ON A FLOORBEAM AT STA 5430. REPAIRED IAW REA Y153-13321-MR.
- 6 Nov 1995
Floorbeam, corroded
DURING C-CHECK, CORROSION WAS FOUND ON A FLOORBEAM AT STA 3030. REPAIRED IAW REA Y153-13321-MR.
- 6 Nov 1995
Floorbeam, corroded
DURING C-CHECK, CORROSION WAS FOUND ON A FLOORBEAM AT STA 5430. REPAIRED IAW REA Y153-13321-MR.
- 6 Nov 1995
Floorbeam, corroded
DURING C-CHECK, CORROSION WAS FOUND ON A FLOORBEAM AT STA 2550. REPAIRED IAW REA Y153-13321-MR.
- 6 Nov 1995
Floorbeam, corroded
DURING C-CHECK, CORROSION WAS FOUND ON A FLOORBEAM AT STA 6120. REPAIRED IAW REA Y153-13321-MR.
- 6 Nov 1995
Support, corroded
DURING C-CHECK, THE LONGITUDINAL FLOOR SUPPORT BETWEEN STA 840 AND 8080 LBL 300 WAS FOUND CORRODED. REPAIRED IAW REA Y153-13320-MR.
- 6 Nov 1995
Floorbeam, corroded
DURING C-CHECK, THE FLOORBEAM AT STA 6600 WAS FOUND CORRODED. REPAIRED IAW REA Y153-13320-MR.
- 5 Nov 1995
Floorbeam, corroded
DURING C-CHECK, CORROSION WAS FOUND ON A FLOORBEAM AT STA 4470. REPAIRED IAW REA Y153-13321-MR.
- 5 Nov 1995
Floorbeam, corroded
DURING C-CHECK, CORROSION WAS FOUND ON A FLOORBEAM AT STA 1535. REPAIRED IAW REA Y153-13321-MR.
- 5 Nov 1995
Floorbeam, corroded
DURING C-CHECK, CORROSION WAS FOUND ON A FLOORBEAM AT STA 5160. REPAIRED IAW REA Y153-13321-MR.
- 5 Nov 1995
Floorbeam, corroded
DURING C-CHECK, CORROSION WAS FOUND ON A FLOORBEAM AT STA 2095. REPAIRED IAW REA Y153-13321-MR.
- 3 Nov 1995
Floorbeam, corroded
DURING C-CHECK, CORROSION WAS FOUND ON A FLOORBEAM AT STA 3720. REPAIRED IAW REA Y153-13321-MR.
- 3 Nov 1995
Floorbeam, corroded
DURING C-CHECK, CORROSION WAS FOUND ON A FLOORBEAM AT STA 6390. REPAIRED IAW REA Y153-13321-MR.
- 3 Nov 1995
Support, damaged
DURING C-CHECK, THE LONGITUDINAL FLOOR SUPPORT BETWEEN STA 2280 AND 2760 RBL 300 WAS FOUND DAMAGED. REPAIRED IAW REA Y153-13320-MR.
- 3 Nov 1995
Support, damaged
DURING C-CHECK, THE LONGITUDINAL FLOOR SUPPORT BETWEEN STA 7580 AND 8080 RBL 300 WAS FOUND DAMAGED. REPAIRED IAW REA Y153-13320-MR.
- 3 Nov 1995
Support, damaged
DURING C-CHECK THE LONGITUDINAL FLOOR SUPPORT BETWEEN STA 3720 AND 4200 RBL 300 WAS FOUND DAMAGED. REPAIRED IAW REA Y153-13320-MR.
- 3 Nov 1995
Support, damaged
DURING C-CHECK, THE LONGITUDINAL FLOOR SUPPORT BETWEEN STA 2760 AND 3240 RBL 300 WAS FOUND DAMAGED. REPAIRED IAW REA Y153-13320-MR.
- 3 Nov 1995
Support, damaged
DURING C-CHECK, THE LONGITUDINAL FLOOR SUPPORT BETWEEN STA 5160 AND 5640 RBL 300 WAS FOUND DAMAGED. REPAIRED IAW REA Y153-13320-MR.
- 3 Nov 1995
Support, damaged
DURING C-CHECK, THE LONGITUDINAL FLOOR SUPPORT BETWEEN STA 4680 AND 4200 RBL 300 WAS FOUND DAMAGED. REPAIRED IAW REA Y153-13320-MR.
- 3 Nov 1995
Support, damaged
DURING C-CHECK, THE LONGITUDINAL FLOOR SUPPORT BETWEEN STA 6600 AND 7080 RBL 300 WAS FOUND DAMAGED. REPAIRED IAW REA Y153-13320-MR.
- 3 Nov 1995
Support, damaged
DURING C-CHECK, THE LONGITUDINAL FLOOR SUPPORT BETWEEN STA 5160 AND 5640 LBL 300 WAS FOUND DAMAGED. REPAIRED IAW REA Y153-13320-MR.
- 3 Nov 1995
Support, damaged
DURING C-CHECK, THE LONGITUDINAL FLOOR SUPPORT BETWEEN STA 4680 AND 5160 RBL 300 WAS FOUND DAMAGED. REPAIRED IAW REA Y153-13320-MR.
- 3 Nov 1995
Support, damaged
DURING C-CHECK, THE LONGITUDINAL FLOOR SUPPORT BETWEEN STA 7080 AND 7580 RBL 300 WAS FOUND DAMAGED. REPAIRED IAW REA Y153-13320-MR.
- 3 Nov 1995
Support, damaged
DURING C-CHECK, THE LONGITUDINAL FLOOR SUPPORT BETWEEN STA 7580 AND 8080 LBL 300 WAS FOUND DAMAGED. REPAIRED IAW REA Y153-13320-MR.
- 3 Nov 1995
Support, damaged
DURING C-CHECK, THE LONGITUDINAL FLOOR SUPPORT BETWEEN STA 7580 AND 8080 RBL 300 WAS FOUND DAMAGED. REPAIRED IAW REA Y153-13320-MR.
- 3 Nov 1995
Support, damaged
DURING C-CHECK, THE LONGITUDINAL FLOOR SUPPORT BETWEEN STA 3720 AND 4200 LBL 300 WAS FOUND DAMAGED. REPAIRED IAW REA Y153-13320-MR.
- 3 Nov 1995
Support, damaged
DURING C-CHECK, THE LONGITUDINAL FLOOR SUPPORT BETWEEN STA 7080 AND 7580 LBL 300 WAS FOUND DAMAGED. REPAIRED IAW REA Y153-13320-MR.
- 3 Nov 1995
Support, damaged
DURING C-CHECK, THE LONGITUDINAL FLOOR SUPPORT BETWEEN STA 6120 AND 6600 RBL 300 WAS FOUND DAMAGED. REPAIRED IAW REA Y153-13320-MR.
- 3 Nov 1995
Support, damaged
DURING C-CHECK, THE LONGITUDINAL FLOOR SUPPORT BETWEEN STA 4680 AND 5160 LBL 300 WAS FOUND DAMAGED. REPAIRED IAW REA Y153-13320-MR.
- 2 Nov 1995
Floorbeam, corroded
DURING C-CHECK, CORROSION WAS FOUND ON A FLOORBEAM AT STA 4200. REPAIRED IAW REA Y153-13321-MR.
- 2 Nov 1995
Floorbeam, corroded
DURING C-CHECK, CORROSION WAS FOUND ON A FLOORBEAM AT STA 2760. REPAIRED IAW REA Y153-13321-MR.
- 21 Feb 1995
Spring, defective
FLAP ASYMMETRY LIGHT ILLUMINATED DURING RETRACTION AFTER TAKEOFF. FLAP MOVEMENT STOPPED AT EIGHT DEGREES. ACCOMPLISHED ABNORMAL CHECKLIST AND RETURNED TO…