N913UA
Dji INSPIRE 2 FAA →
registration
earlier registrations
1 past record
- 1991
service difficulty reports
39 reports
- 3 Aug 2009
Structure, damaged
LEFT WING METAL PROTRUDING 1 INCH BY 6 INCHES AFT OF SLAT. REMOVAL OF NR 2 LEFT SLAT COMPLETED UP TO STEP 11-L. REMOVED NR 2 SLAT UP TO STEP (12) (P/N…
- 13 May 2008
Girt Bar, loose
DOOR 1L GIRT BAR LOOSE. *S/D* FOUND GIRT BAR LOOSE IN STOWED POS ON DOOR WHEN SLIDE UNARMED. ADJUSTED HOLDER FOR GIRT BAR ON DOOR. AC OK FOR SERVICE.
- 5 May 2008
Wedge, damaged
NR 3 SLAT T/E WEDGE ASSEMBLY HAS DAMAGE.
- 5 May 2008
Wedge, damaged
NR 3 SLAT T/E WEDGE ASSEMBLY HAS DAMAGE. *S/D* METAL OVERLAY PIECE IS LOCATED IN THE FLIGHT DECK. PERFORMED REPAIR OF SLAT 3 TRAILING EDGE WEDGE BOND…
- 4 May 2008
Oxygen Mask, faulty
FO O2 MASK HISSES, LEAKS WHEN DONNED. REPLACED FIRST OFFICERS O2 MASK PER MM 35-12-86. OP CHECKED GOOD. AC OK FOR SERVICE.
- 11 Dec 2007
Unknown, smoke
LIGHT SMOKE IN THE CABIN WITH PACKS ON.
- 11 Dec 2007
Inverter, inoperative
CABIN FLOOR MOUNTED EEL LIGHTS INOP FROM ROW 4 TO 9. REPLACED BATTERY PACK AND INVERTER.
- 11 Dec 2007
Wire, broken
EXIT SIGN WITH TWO ARROWS AT CENTER OF CABIN IS INOP. REPAIRED BROKEN WIRE.
- 11 Dec 2007
Unknown, smoke
CREW REPORT: LIGHT SMOKE IN THE CABIN WITH PACKS ON. UNABLE TO DUPLICATE. ACCOMPLISHED PACK BURN WITH EXTERNAL AIR CART. RAN PACKS FULL WARM FOR APPX 10 MIN…
- 23 Aug 2007
Door Frame, cracked
AFT CARGO DOOR CUTOUT, FWD FRAME IS CRACKED AT LWR STOP FITTING. MAJOR REPAIR ACCOMPLISHED: REMOVED & REPLACED FWD FRAME BS 794.
- 23 Aug 2007
Door Frame, cracked
FWD CARGO DOORWAY CUTOUT, AFT FRAME IS CRACKED AT LWR STOP FITTING. MAJOR REPAIR ACCOMPLISHED: REMOVED & INSTALLED NEW FRAME.
- 21 Aug 2007
Crease Beam, damaged
AFT CARGO CREASE BEAM AT WL 208 IS DAMAGED. MAJOR REPAIR ACCOMPLISHED: INSTALLED TYPICAL EXTRUDED SECTION REPAIR. CREASE BEAM CUT AT STA 776. REPAIRED FROM…
- 21 Aug 2007
Frame, damaged
CABIN FLOOR CREASE BEAM REQUIRES TO BE CUT FOR ACCESS TO REPAIR FRAME BS 446 - 466 STR 17R. MAJOR REPAIR ACCOMPLISHED: FABRICATED & INSTALLED CREASE BEAM…
- 28 Mar 2007
Flap System, unknown
RECEIVED SPLIT FLAPS ON APPROACH BETWEEN FLAP POSITION 1 AND 2. [SUP 4-20-07] REPLACED FLAP POSITION INDICATOR. NO FAULT FOUND. COULD NOT DUPLICATE ERROR.…
- 7 Mar 2007
Smoke Detector, faulty
FWD CARGO LOOP "B" & AFT CARGO LOOP "A" FAULT LIGHTS ON. POTENTIAL FAULTY SMOKE DETECTORS. REPLACED 1B AND 3A SMOKE DETECTORS. NO REPEATS SINCE ORIGINAL.
- 7 Mar 2007
Smoke Detector, faulty
AFT CARGO LOOP "A" FAULT LIGHTS ON. POTENTIAL FAULTY SMOKE DETECTORS. REPLACED 3A SMOKE DETECTOR. NO REPEATS SINCE ORIGINAL. THIS SDR CREATED IN RESPONSE TO…
- 24 Feb 2007
Unknown, unknown
AFTER TAKEOFF, FLAPS WOULD NOT RETRACT. AFTER SEVERAL ATTEMPTS FLAPS FINALLY RETRACTED NORMALLY. FLAP TRANSMITTERS OUT OF TOLERANCE. ADJUSTED TRANSMITTERS.…
- 4 Feb 2007
Skin, delaminated
AFT CARGO DOOR CUTOUT AFT LOWER CORNER HAS SKIN DELAMINATION AT STR 24R BS 847. INSTALLED EXTERNAL FUSELAGE SKIN DOUBLER TRIPLER REPAIR PER SRM 53-00-01…
- 2 Feb 2007
Girt Bar, out of position
FOUND PASSENGER DOOR L1 SLIDE GIRT IS NOT PROPERLY STOWED ON THE SLIDE. REPACKED GIRT BAR MATERIAL.
- 6 Jan 2007
Module, unsecure
CABIN PRESSURE LOSS, ALTITUDE WARNING HORN SOUNDED ON CLIMBOUT. RETURN TO FIELD. *S/D* FOUND FAULTY P5 PRESSURIZATION PANEL AND UNSECURED DELTA P MODULE.…
- 2 Sep 2006
Light, inoperative
FLOOR EEL LIGHT AT SEAT 21AB IS INOPERATIVE. REPLACED EEL STRIP.
- 18 May 2006
Skin, damaged
AFT FUSELAGE LWR EXTERNAL SKIN HAS 1 EACH SCRIBE MARK AT AFT CARGO DOOR AFT LWR CORNER BELOW THRESHOLD.
- 14 Apr 2006
Switch, failed
CREW REPORTS AFTER TAKEOFF, AUTO-THROTTLE WENT INOP, L-NAV FAILED, BOTH TRANSPONDERS FAILED, AND AFTER FURTHER CLIMBING, CABIN ALT HORN SOUNDED. EMERGENCY…
- 30 Mar 2006
Connector, burned
LEFT AFT BOOST PUMP CONNECTOR BURNED TO PUMP ASSEMBLY. THE LEAKAGE OBSERVED WAS VERIFIED AND CAUSED BY A LOCALIZED OVERHEATING OF THE CONNECTOR PINS THAT…
- 26 Aug 2005
Stringer, cracked
STR 10L UPR FLANGE IS CRACKED AT STA 294.
- 21 Aug 2005
Fitting, cracked
CRACK IN FUSELAGE MAIN FRAME FITTING UNDER CABIN FLOOR AT STA 616 RBL 70, INNER CHORD AT BOTTOM 2 RIVETS.
- 19 Jul 2005
Slide, dislodged
DOOR 1 LEFT SLIDE PACK CAME COMPLETELY OFF. THE CAUSE FOR THIS EVENT IS UNKNOWN. THE CORRECTIVE ACTION WAS INSPECTION OF THE SLIDE AND RE-INSTALLATION ON SAME…
- 11 Oct 2004
Slide, dislodged
DOOR 1L SLIDE PACK FELL OUT. SHOP FINDINGS SHOWED THAT SLIDE NEEDED REPACKING. SLIDE WAS INSPECTED, REPACKED AND RETURNED TO SERVICE.
- 11 Nov 2003
Adc, failed
RETURNED DUE TO F/O AIRSPEED INDICATOR FLAG, MACH INDICATOR, VMO INDICATOR FLAG. ATTEMPTS TO CLEAR THE FLAGS WERE UNSUCCESFUL. THE AIR DATA COMPUTER WAS…
- 13 Aug 2001
Filler, broken
AFT PIT STA 727A FRAME RADIUS FILLER IS BROKEN AT RBL 24. *S/D* MAJOR REPAIR ACCOMPLISHED. REPLACED FILLER AND STRAP.
- 7 Aug 2001
Floorbeam, corroded
AFT CABIN FLOORBEAM UPPER T-CAP HAS CORROSION AT BS 947.5 LBL 15. INSTALLED REINFORCING STRAP AND ANGLE DOUBLER. MAJOR REPAIR ACCOMPLISHED.
- 7 Aug 2001
Floorbeam, corroded
AFT CABIN FLOORBEAM T-CAP HAS CORROSION STA 947.5 RBL 25 TO RBL 33. REMOVED DAMAGE. INSTALLED REINFORCEMENT REPAIR. MAJOR REPAIR ACCOMPLISHED.
- 7 Aug 2001
Floorbeam, corroded
AFT CABIN FLOOR BEAM UPPER T-CAP HAS CORROSION AT BS 947.5 LBL 15. MAJOR REPAIR ACCOMPLISHED. INSTALLED REINFORCING STRAP AND ANGLE DOUBLER.
- 5 Aug 2001
Crease Beam, damaged
CABIN RT CREASE BEAM WEB HAS TWO ELONGATED HOLES BETWEEN BS 907 TO 927, WL 208. MAJOR REPAIR ACCOMPLISHED. REPLACED WEB.
- 4 Aug 2001
Seat Track, corroded
AFT CABIN RT FLOOR SECTION OF SEAT TRACK AT BS 986 - BS 1016, RBL 39 HAS CORROSION. MAJOR REPAIR ACCOMPLISHED. REPLACED SEAT TRACK.
- 4 Aug 2001
Floorbeam, damaged
FWD CABIN FLOORBEAM UPPER CORD HAS EXCESSIVE MATERIAL REMOVED AT BS 312, LBL 14, 20, 23 AND LBL 57. MAJOR REPAIR ACCOMPLISHED. REMOVED DAMAGED T-CAP, SPLICE…
- 26 Jul 2001
Skin, gouged
LOWER FUSELAGE SKIN GOUGE HAS EXCESSIVE MATERIAL LOSS, AT BS887, STR27L. INSTALLED DOUBLER. MAJOR REPAIR ACCOMPLISHED.
- 1 Mar 2001
Frame, damaged
PREVIOUS REPAIRED AREA ON BS 178 WILL INTERFER WITH THE CHORD DOUBLER. THIS IS CONSIDERED A MAJOR REPAIR. INSTALLED DOUBLER TO AFFECTED AREA. ACCOMPLISHED…
- 13 Sep 1996
Overheat Sensor, inoperative
RIGHT WING OVERHEAT LIGHT CAME ON AFTER TAKEOFF. ACCOMPLISHED PROCEDURE AND LIGHT WENT OUT AFTER TWO MINUTES. APPEARS TO COINCIDE WITH HIGH POWER SETTINGS.…