N912UA
1991 Boeing 737-522 standard FAA →
earlier registrations
1 past record
- 1991
service difficulty reports
33 reports
- 9 May 2013
Structure, cracked
RIGHT AFT SERVICE DOOR CUTOUT HAS A 1.5 INCH CRACK AT FWD LOWER CORNER, REPAIR AS REQUIRED. CATEGORY B REPAIR INSTALLED AT AFT SERVICE DOOR CUTOUT LOWER FWD…
- 31 May 2009
Light, loose
EMERGENCY LIGHTING FLOOR STRIP LOOSE NEAR ROWS 5 & 6. SECURED LIGHT STRIP.
- 13 Apr 2009
Battery Pack, discharged
CENTER EMERGENCY EXIT LIGHT INOP BETWEEN 2L AND 2R. REPLACED BATTERY PACK M1197, OPS OK.
- 10 Nov 2008
Indicator, faulty
CREW OXYGEN PRESSURE INDICATOR INOP. CREW COMMENTS: FLUCTUATING 0 TO 1600. CONFIRMED PRESSURE AT BOTTLES OKAY. REPLACED COCKPIT CREW OXYGEN INDICATOR, READS…
- 28 Sep 2008
Panel, damaged
RIGHT WING INBOARD LWR FIXED T/E PANEL NEXT TO BODY FAIRING DAMAGED AT WBL 71.26. REPLACED PANEL.
- 21 Feb 2008
Fire Bottle, malfunctioned
DURING 3SVC CHECK FOUND CARGO FIRE SYSTEM 1ST BOTTLE DISCHARGE LIGHT ON. REPLACED NR 1 CARGO FIRE BOTTLE PER MM 26-23-01 AND GROUND CHECKED OK. REPLACED DUCT…
- 27 Dec 2007
O-Ring, damaged
LOW BOTTLE PRESSURE. FOUND PISTON O-RING LEAKING. REPLACE O-RING.
- 7 Sep 2007
Fire Bottle, discharged
DURING PANEL REPLACEMENT FOR POP SPILL FOUND 1ST BOTTLE FOR CARGO FIRE BOTTLE DISCHARGE LIGHT ON. OPENED PANEL IN FWD PIT AND FOUND BOTTLE DISCHARGED.…
- 5 Sep 2007
Bleed Air Sys, malfunctioned
DURING CLIMB ACFT LOST RT BLEED SUPPLY. CABIN PRESSURE REACHED 10,000 FT, RAPID DESCENT TO FL230 AND SITUATION STABILIZED. MASKS DID NOT DEPLOY.
- 21 Aug 2007
Disc, ruptured
LOW BOTTLE PRESSURE. FOUND RUPTURED PRESSURE DISC. REPLACED DISC, RECHECKED FOR LEAKS, NO LEAKS FOUND. RESERVICED BOTTLE.
- 6 Jul 2007
Light, inoperative
FLOOR EEL LIGHTS INOPERATIVE FROM SEAT 9B TO 15A. [07-27-07] SECURED EEL LIGHTS FEEDER CABLE.
- 6 Jul 2007
Lamp, inoperative
STOW BIN 2A EMERGENCY LIGHT IS INOPERATIVE. [07-27-07] RELAMPED.
- 20 Jun 2007
Door, damaged
AFT RIGHT SERVICE DOOR IS DAMAGED. [07-13-07] REMOVED DAMAGE. FABRICATED AND INSTALLED REPAIR DOUBLERS, TRIPLER AND FILLER. REFERENCR SRM 53-00-01 REPAIR 32.
- 30 Mar 2007
Slide, out of position
DOOR 1L SLIDE FELL PARTIALLY OUT OF COVER. [SUP 5-1-07] CAUSE IS UNKNOWN, REPLACED SLIDE.
- 3 Feb 2007
Intercostal, cracked
FOUND LT FUSELAGE INTERNAL INTERCOSTAL IS CRACKED AT STR 16L. JUST AFT OF FRAME AT BS 294.5. REPLACED INTERCOSTAL.
- 3 Feb 2007
Bracket, cracked
LT FUSELAGE INTERNAL AFT BRACKET IS CRACKED IN RADIUS FOR INTERCOSTAL A STR 11L JUST FWD OF BS 360, VIEW FROM LWR SURFACE. INSTALLED NEW BRACKET.
- 19 Jan 2007
Skin, delaminated
LEFT WING OTBD FORE FLAP INBD END DELAMINATED. MAJOR REPAIR: REPAIRED FLAP PER SRM 95-57-53-04 IN SHOP. REINSTALLED.
- 1 Aug 2005
Attach Fitting, corroded
VERTICAL STABILIZER LT AND RT AFT PRIMARY ATTACH LUG FITTINGS ON FUSELAGE HAD CORROSION REMOVAL BEYOND LIMITS. REPLACED LT AND RT AFT PRIMARY ATTACH LUGS AND…
- 31 Jul 2005
Skin, dented
STA 837 IS DENTED BETWEEN STR 25L AND 26L. CUT OUT DAMAGE AND INSTALLED DOUBLER AND TRIPLER REPAIR PER SRM 53-00-01 FIG 229.
- 26 Jul 2005
Skin, dented
STATION 807 IS DENTED AT STR 28R. CUT OUT DAMAGE AND INSTALLED A TRIPLER REPAIR REF SRM 53-00-01 FIG 229.
- 24 Jul 2005
Skin, dented
STATION 203 HAS A SCRATCH BETWEEN STR 24 AND 25 LT. CUT-OUT DAMAGED AREAS AND INSTALLED TRIPLER REPAIR REF SRM 53-10-01 FIG 211 DETAIL XII AND XIII.
- 20 Jul 2005
Frame, gouged
STA 211 FRAME IS GOUGED APPROXIMATELY 6 FEET ABOVE STRINGER 17R. REPAIRED WEB WITH DOUBLER PER SRM 51-70-13 FIG 1 DETAIL 1
- 15 Mar 2005
Fire Loop, malfunctioned
DIVERTED TO LNK DUE TO NR 2 ENGINE OVERHEAT INDICATION. SHUTDOWN NR 2 ENGINE AND BLEW BOTH FIRE BOTTLES. THERE WERE NO EVIDENCE OF FIRE OR OVERHEAT ON POST…
- 12 Nov 2004
Bulkhead, damaged
STATION 178 FWD BULKHEAD IS DAMAGED. ACCOMPLISHED ULTRASONIC INSPECTION ALONG THE STIFFENER AT WATER LINE 195 FROM THE AFT SIDE OF THE WEB. REPLACED BS 178…
- 11 Nov 2002
Door Frame, cracked
FORWARD CARGO DOOR FORWARD FUSELAGE FRAME CRACK AT LWR STOP FITTING OUTBOARD LOWER CORNER. MAJOR REPAIR ACCOMPLISHED. INSTALLED REPAIR DOUBLER.
- 3 Oct 2002
Warning System, malfunctioned
RETURN TO FIELD DUE TO GEAR UNSAFE INDICATION. LT GEAR UNSAFE LIGHT IS ILLUMINATED WITH GEAR HANDLE IN THE OFF POSITION. OHMED LT MAIN UP SENSOR, CHECKED OK,…
- 20 Jul 2001
Bulkhead, gouged
3 GOUGES ON FWD PRESSURE BULKHEAD. 1 GOUGE AT BS 178, LBL 16, WL 208. 2 AT BS 178, LBL 22, WL 197. INSTALLED DOUBLER REPAIR. MAJOR REPAIR ACCOMPLISHED.
- 12 Jul 2001
Stringer, corroded
STRINGER CORRODED. STA 266 STR 22. MAJOR REPAIR ACCOMPLISHED.INSTALLED FILLERS AND STRINGER SPLICE.
- 6 Jul 2001
Door Frame, cracked
FWD GALLEY DOOR AFT SIDE CRACKED AT THIRD STOP FITTING CUTOUT. REMOVED DAMAGE. INSTALLED DOUBLER. MAJOR REPAIR ACCOMPLISHED.
- 31 Oct 2000
Detector, damaged
RIGHT WING-BODY OVERHEAT DETECTION SYSTEM INOPERATIVE. *S/D* REPLACED RIGHT HAND PYLON OVERHEAT LOOP M1204. SYSTEM OPERATION CHECKED NORMAL.
- 10 Oct 1999
Indicator, failed
THERE IS A FIVE DEGREE DISCREPANCY BETWEEN THE COMMANDED AND DISPLAYED INDICATIONS ON THE TRAILING EDGE FLAPS. ALTERNATE FLAPS WERE USED TO FULLY EXTEND THE…
- 24 Dec 1996
Connector, loose
FLOOR EEL STRIP NEXT TO FWD GALLEY INOP. SECURED LIGHT CONNECTION, OPS CHECK OK.
- 22 Jan 1996
Strip, inoperative
FORWARD GALLEY EMERGENCY ESCAPE PATH LIGHT STRIP INOP. REPLACED GALLEY LIGHT STRIP AND CHECKS OK.