N911NH
2010 Eurocopter Deutschland Gmbh MBB-BK 117 C-2 standard FAA →
registration
- 2010
service difficulty reports
19 reports
- 25 Jul 2017
Starter Gen, defective
DURING FLIGHT THE MASTER CAUTION ILLUMINATED AND PITCH DAMPENER CAUTION WAS DISPLAYED ON CAD. DURING THAT TIME THE RADAR ALTIMETER WAS ERRATIC WHILE PILOT…
- 10 May 2017
Seal, loose
THE POWER TURBINE NOZZLE GUIDE VANE SEAL HAS BECOME FREE TO ROTATE BETWEEN THE REAR BEARING SUPPORT AND THE POWER TURBINE NOZZLE GUIDE VANE ASSEMBLY. CAUSING…
- 21 Apr 2017
Mount, cracked
FOUND RIVETS PULLED THROUGH ON SUCTION PUMP MOUNTED ON AFT FUSELAGE DECK APPROXIMATELY 4 INCHES AFT OF AIRCRAFT BATTERY. ONCE PUMP WAS REMOVED, FOUND CRACKS…
- 18 Mar 2004
Compass, broken
WARRANTY. ADUSTMENT SCREW ON UNIT IS BROKEN. REPLACED WITH SERVICABLE UNIT. 03/25/2004
- 17 Mar 2004
Manifold, clogged
WARRANTY. ENG S/N 32047. UNIT REMOVED DUE TO CLOGGING OF NOZZLES. HARDCARD ENCLOSED. REPLACED WITH SERVICEABLE UNIT. 03/19/2004
- 17 Mar 2004
Manifold, clogged
WARRANTY. ENG S/N 32047. UNIT REMOVED DUE TO CLOGGING OF NOZZLES. HARDCARD ENCLOSED. REPLACED WITH SERVICABLE UNIT. 03/19/2004
- 17 Mar 2004
Injector, clogged
WARRANTY. ENG S/N 32047. UNIT REMOVED DUE TO CLOGGING OF NOZZLES. HARDCARD ENCLOSED. REPLACED WITH SERVICABLE UNIT. 03/19/2004
- 16 Mar 2004
Actuator, unserviceable
ACTUATOR FAILED, NO REFERENCE VOLTAGE FOR ACT. POSITION. HARDCARD ENCLOSED. REPLACED WITH SERVICABLE UNIT. 03/17/2004
- 16 Mar 2004
Pump, leaking
HYDRAULIC PUMP IS LEAKING AT SHAFT. REPLACED WITH SERVICABLE UNIT. 03/17/2004
- 12 Mar 2004
Window, cracked
WINDOW CRACKED NEAR HANDLE. REPLACED WITH SERVICEABLE UNIT. 03/25/2004
- 25 Feb 2004
Mount, out of limits
EXCESSIVE AIRFRAME VIBRATION, OUT OF LIMITS, REMOVED FROM RT AFT POSITION. REPLACED WITH SERVICABLE UNIT. 02/27/2004
- 21 Feb 2004
Mount, out of limits
A/C VIBRATION, MOUNT OUT OF LIMITS, REMOVED FROM RT FWD POSITION. THIS UNIT WAS ONE OF THE 4 SENT TO A/C S/N 0287. REPLACED WITH SERVICABLE UNIT. 02/26/2004
- 21 Feb 2004
Output Seal, leaking
A/C PACK GEARBOX OUTPUT SEAL LEAKS. REPLACED WITH SERVICABLE UNIT. 02/27/2004
- 20 Jan 2004
Signal Cond Unit, inoperative
MMI INOPERATIVE. REPLACED WITH SERVICABLE UNIT. 02/04/2004
- 12 Jan 2004
Indicator, malfunctioned
TURN AND SLIP INDICATOR BACKLIGHTING INOPERATIVE. REPLACED WITH SERVICEABLE UNIT.
- 28 Dec 2003
Indicator, malfunctioned
TRIPLE TACH INDICATOR N2 WILL NOT PERFORM SWEEP CHECK. UNIT ONLY LASTED 6.8HRS WHEN INSTALLED. REPLACED WITH SERVICEABLE UNIT. 01/14/2004
- 21 Mar 2003
Pump, inoperative
BOOSTER PUMP INOPERABLE. REPLACED WITH SERVICEABLE UNIT.
- 30 Jan 2003
Blade, out of balance
BLADES WOULD NOT BALANCE. REPLACED WITH SERVICEABLE UNITS S/N 413 AND 414.
- 8 Jan 2003
Compensator, cracked
COMPENSATOR CRACKED AND HAS WATER DAMAGE. REPLACED WITH SERVICEABLE UNIT.