- 1983
NTSB
- 7 May 2000
accident, Cincinnati OH
service difficulty reports
40 reports
- 1 Mar 2024
Unknown, odor
MED CREW REPORTING JET A SMELL IN AFT CABIN. PILOT DIDN'T SMELL IT IN THE FRONT. RECURRENT ISSUED WITH MULTIPLE WRITE UPS. AT THIS MOMENT UNKNOWN SOURCE.
- 11 Nov 1999
Transmitter, intermittent
TORQUE TRANSMITTER NTERMITTENTLY INOPERATIVE.
- 11 Nov 1999
Indicator, intermittent
INDICATOR INTERMITTENTLY INOPERATIVE, INDICATOR TEST AND FUNCTION.
- 8 Apr 1999
Receiver, malfunctioned
AFTER WARM-UP, THERE IS CONSTANT FEEDBACK.
- 17 Aug 1998
Radar, malfunctioned
INDICATOR SAYS ERROR WHEN GOING THROUGH TEST MODE.
- 22 Jun 1998
Switch, loose
ADF/VOR SWITCH IS LOOSE AND NO ADF INDICATION.
- 4 Jun 1998
Light, inoperative
INSTRUMENT LIGHT IS INOPERATIVE.
- 16 Apr 1998
Gps, failed
GPS NOT PICKING UP SATELLITES.
- 5 Feb 1998
Transponder, failed
TRANSPONDER HAS NO OUTPUT.
- 5 Nov 1997
Filter Assy, malfunctioned
FILTER ASSY BYPASS INDICATOR DOES NOT PROPERLY OPERATE.
- 22 Oct 1997
Indicator, out of tolerance
ENGINE RPM INDICATOR HIGH OUT OF TOLERANCE ABOVE 50 PERCENT INTERMITTENT OPERATION.
- 23 Jun 1997
Actuator, leaking
T/R ACTUATOR LEAKING HYRAULIC FLUID.
- 19 Jun 1997
Transmitter, intermittent
TORQUE TRANSMITTER INTERMITTENT IN FLIGHT.
- 19 Jun 1997
Indicator, intermittent
MAST MOMENT INDICATOR INTERMITTENT IN FLIGHT.
- 5 Jun 1997
Indicator, defective
AFTER ONE HOUR OF USE, NEEDLE DROPS FROM NINETY PERCENT TO FIFTY PERCENT.
- 24 Apr 1997
Blade, defective
WEIGHT PACKAGE MOVIAL. S/N 1158 & 1174
- 23 Apr 1997
Armature, brushes worn
START/GEN BRUSHES WORN. SHORTED OUT. RECEIVED REWOUND FROM VENDOR. TIME SINCE REPAIR 258:15.
- 10 Feb 1997
Control Display, faulty
DIMMING CONTROL NOT WORKING, STAYS BRIGHT. REPLACED V101 PHOTOCELL AND S103 IDT SWITCH. REPAIRED. TESTED. CHECKED 28V LIGHTING. BENCH CHECK GOOD.
- 30 Dec 1996
Mount, cracked
ONE LEG OF ENGINE MOUNT CRACKED IN HALF.
- 14 Oct 1996
Indicator, reads high
INDICATES HIGH OUT OF TOLERANCE AT 100%. STICKS ON START.
- 10 Oct 1996
Control Unit, malfunction
ADJUSTMENT KNOBS FOR FREQUENCY CHANGE DON'T WORK PROPERLY. PERFORMED PRELIMINARY INSPECTION. CLEANED WAFERS, FOUND PHOTOCELL (V101) NOT DIMMING. REPLACED V101…
- 30 Sep 1996
Manifold, cracked
ENGINE LEAK CHECK REVEALED: FUEL LEAKING FROM FUEL MANIFOLD TUBING. REPLACED DISCREPANT PART.
- 9 Sep 1996
Ejector Duct, damaged
DAMAGE DONE TO EJECTORS. FROM BUMPER PADS THAT ARE MOUNTED TO ENG. COWLING AND AIRFRAME. BUMPER PADS ARE RUBBING HARD ON EXHAUST STACK (EJECTOR) CAUSING WORN…
- 31 Jul 1996
Control Box, defective
ON LCD DISPLAY DIGITS ARE NOT COMPLETE IN SQUELCH SPOTS. CLEANED WAFERS AND DISPLAY CONNECTORS. ALSO REPLACED LOCK RING. REPAIRED. BENCH CHECK GOOD.
- 12 Jan 1996
Control Unit, defective
NOT ALL PL TONES MATCH THUMBWHEEL TO DIGITAL READOUT. TROUBLESHOT AND REPLACED 8 EACH CRIMP CONNECTOR SOCKETS. REPAIRED. BENCH CHECK GOOD.
- 7 Dec 1995
Indicator, light inop
BENCH CHECK NEEDED. REPLACED DH LIGHT SWITCH ASSY. DS101 DUE TO INOPERATIVE LIGHT. REPAIRED. PERFORMED COMPLETE ALIGNMENT AND CALIBRATION. BENCH CHECK GOOD.
- 22 Nov 1995
Control, defective
SOME NUMBERS ARE NOT LIGHTING UP AS REPORTED BY PILOT. REPLACED DEFECTIVE IC205 INTEGRATED CIRCUIT. REPAIRED AND UNIT BENCH CHECK GOOD.
- 13 Jun 1995
Transceiver, defective
OCCASIONALLY CUTTING OUT ON TRANSMIT. MIKE AUDIO IS INTERMITTENT. REPLACED BAD CR2 AND CR3 DIODES. REPAIRED.
- 13 Jun 1995
Indicator, defective
#1 NEEDLE READ 4% LOW AFTER 10 MINUTES OPERATION.
- 3 Mar 1995
Control Unit, failed
PILOT REPORTED SMELLING SMOKE IN COCKPIT. RETURNED TO BASE. MECHANIC INSPECTED AND FOUND COPILOT INSTRUMENT LIGHT DIMMER CONTROL CAUSE OF SMOKE. FOUND WATER…
- 10 Feb 1995
Skynav 5000, malfunction
AUTO DIM NOT WORKING, NOT HOLDING PROGRAMMABLE WAYPOINTS AND KEEPS CYCLING THROUGH SELF TEST. TIME SINCE REPAIR 0:00.
- 23 Jan 1995
Skynav 5000, defective
NOT HOLDING PROGRAMMABLE WAYPOINTS. ENTERED EXTRA WAYPOINTS INTO USER WAYPOINTS. ENTERED "DIRECT TO" FUNCTION AND PULLED POWER PLUG FROM TEST PANEL. AFTER…
- 18 Dec 1994
Cell, defective
BATTERY WEAK. INSPECTED BY ACCESSORY SHOP AND FOUND CELL #9 WOULD NOT HOLD A CHARGE IN SERVICE AND CELL #17 BURNT ON CHARGE. BATTERY PUT INTO SERVICE NEW…
- 2 Nov 1994
Gyro, malfunction
ON "B" TEST CAUSES CYCLIC TO TWITCH AND FAIL 30 SEC CAUTION LIGHT TEST.
- 4 Oct 1994
Actuator, leaks
ACTUATOR SEEPS AROUND PILOT VALVE AND SEALS.
- 24 Sep 1994
Transducer, defective
UNIT WILL NOT TRANSMIT PROPERLY.
- 24 Sep 1994
Compensator, defective
COMPENSATOR UNIT CAUSES HSI TO RATCHET IN DG FREE DRIFT MODE.
- 8 Sep 1994
Transducer, defective
#2 ENGINE TORQUE INDICATOR STICKING.
- 20 Aug 1994
Control Unit, defective
FAILED ELECTRICAL TESTS. CAUSED KICKING IN T/R PEDALS.
- 22 Jan 1994
Spas Computer, defective
SPAS LIGHT ILLUMINATES AS SOON AS SWITCH IS PUT INTO POSITION - SPAS OPERATES NORMALLY IN FLIGHT.