1 past record
- 1991
service difficulty reports
30 reports
- 1 Jun 2008
Fitting, cracked
FOUND CRACKED INTERCOSTAL CLIP S-11L AFT OF STA 294.5, CRACK IN TEE ATTACHMENT ANGLE STR-11L BETWEEN 294.5 & 303.9 STA, CRACK IN CLIP FRAME TO STRINGER S-11…
- 1 Jun 2008
Structure, cracked
LT FS 294 HAS A 1 INCH CRACK AT STRINGER 11, JUST FWD OF WEB ATTACHMENT HOLES. *S/D* MAJOR REPAIR ACCOMPLISHED. REPAIRED PER UA-EVA-71611 AND REO-L01080, HAVE…
- 1 Jun 2008
Attach Fitting, cracked
CRACKS FOUND AT ATTACH CLIP STA 360 STR 11L, STRINGER SPLICE CHANNEL STA 360 STR 15L, INTERCOSTAL WEB STRAP STA 360 STR 16L AND INTERCOSTAL ATTACH ANGLE STA…
- 1 Jun 2008
Web, corroded
INTERCOSTAL WEB CORROSION FOUND AT WEB BS 351.2 & BS 360 STR 11L,12L,14L AND 16L. MAJOR REPAIR ACCOMPLISHED. AREAS REPAIRED PER UA-EVA- 71614 AND REO-01077,…
- 1 Jun 2008
Structure, cracked
STR 10L STA 296 FOUND CRACKED DURING L1 DOOR. MAJOR REPAIR ACCOMPLISHED. REPAIRED PER UA-EVA-71626 AND REO-L01081. FIRST STAGE APPROVAL ONLY. NEW BOEING…
- 1 Jun 2008
Stringer Splice, cracked
LT AT FS 360 STRINGER 16L SPLICE CHANNEL CRACKED. MAJOR REPAIR ACCOMPLISHED. CF 9041 CAN BE CLEARED. EC 955313099SD & AMM 53-13-99 CREATED TO INSPECT REPAIR…
- 21 Feb 2008
B-Nut, loose
PREFLIGHT O2 SHOWS 400 PSI. REPLACED MASK AND SECURED B-NUT NO LEAKS FOUND. AC OK FOR SERVICE.
- 1 Oct 2007
Warning Light, illuminated
RTFL DUE TO LEFT FUEL FILTER BYPASS LIGHT ILLUMINATION. REPLACED FUEL FILTER.
- 1 Oct 2007
Warning Light, illuminated
FEEL DIFF PRESS ILLUM AGAIN DURING DESCENT.
- 1 Oct 2007
Computer, faulty
FEEL DIFF PRESS ILLUM AGAIN DURING DESCENT. DEBRIEFED FLT CREW: WAS TOLD THE ELEVATOR FEEL DIFF PRESS CAME ON AT 34,000 FT, 12,000 AND ON LANDING.…
- 8 Aug 2007
Lamp, burned out
FOUND EEL LAMP INOP ROW 10. REPLACED LAMP. CHKS OKAY.
- 8 Aug 2007
Lamp, burned out
FOUND EMERGENCY AISLE LIGHT INOP ROW 15D. RELAMPED. OPS CK NORMAL.
- 8 Aug 2007
Lamp, burned out
FOUND EEL LAMP DIM ROW 15. REPLACED LAMP. CKS NORMAL.
- 29 May 2007
Smoke Detector, faulty
CREW REPORT: FWD CARGO DETECTION LIGHT -B- ON AND OFF TWICE IN FLIGHT FOR A FEW SECS THEN OFF. REPLACED "B" LOOP SMOKE DETECTORS,
- 13 Jul 2006
Pin, installed
FWD GALLEY DOOR EVAC SLIDE HAS SAFETY PIN INSTALLED, NOT REMOVED AFTER MAINTENANCE. SAFETY PIN NOT REMOVED. REMOVED SAFETY PIN.
- 9 Jul 2006
Odor, detected
AFTER PUSHBACK F/A REPORTED A BURNING SMELL IN THE AFT GALLEY. UNABLE TO DUPLICATE BURNING ODOR.
- 25 Jan 2005
Skin, dented
LT HORIZ STAB LEADING EDGE IS DENTED APROX 4' FROM FUSE. SUPPLEMENTAL DATA UPDATE MAJOR REPAIR ACCOMPLISHED. REMOVED DENT DAMAGE AND INSTALLED DOUBLER REPAIR.
- 20 Jan 2005
Frame, damaged
BS 178 BULKHEAD ON THE UPPER LT CHORD WAS FOUND TO HAVE INSUFFECENT EDGE DISTANCE AT WL 230 FOR REQUIRED OVERSIZING OF FASTENER HOLES. MAJOR REPAIR…
- 16 Jan 2005
Floorbeam, corroded
STA 986 FLOORBEAM FWD FLANGE HAS CORROSION FROM RBL 16 TO RBL 41. DATA MAJOR CUT-OUT DAMAGE AND INSTALLED REPAIR ANGLE AND FILLER.
- 15 Jan 2005
Floorbeam, corroded
FLOORBEAM CORRODED ON AFT FLANGE STA 986 FROM RBL 10 TO LBL 6. SUPPLEMENTAL DATA UPDATE, MAJOR REPAIR ACCOMPLISHED. CUT-OUT DAMAGE AND INSTALLED REPAIR ANGLE…
- 15 Jan 2005
Floorbeam, corroded
FLOORBEAM AT STATION 947 HAS CORROSION FROM LBL 14 TO RBL 53. SUPPLEMENTAL DATA UPDATE MAJOR REPAIR ACCOMPLISHED. SPLICED IN NEW SECTION OF FLOOR BEAM.
- 15 Jan 2005
Skin, dented
DENT FOUND AT LT SIDE OF FUSELAGE 3 FT AFT OF DOOR 1L SILL. CUT-OUT DAMAGE AND INSTALLED DOUBLER AND TRIPLER REPAIR.
- 9 Jan 2005
Shear Web, cracked
LEFT SHEAR WEB AT STA 194 IS CRACKED AT WL 207. REPLACED SHEAR WEB.
- 30 Jul 2004
Light, inoperative
AFT SECTION OF EEL LIGHT IS INOPERATIVE. REPLACE DEFECTIVE RIBBON.
- 1 Jan 2004
Fire Loop, malfunctioned
RETURNED TO ORD DUE TO NR 2 ENGINE OVERHEAT INDICATION LIGHT. MAINTENANCE PERFORMED TROUBLESHOOTING OF THE NR 2 OVERHEAT DETECTION SYSTEM AND REPLACED M1121…
- 31 Aug 2001
Fitting, leaking
UNSCHEDULED LANDING DUE TO A-SYSTEM HYDRAULIC PROBLEM. *S/D* TIGHTENED LOOSE FITTING ON A-SYS MODULE (TO A-SYS ELEC PUMP). REFILLED A SYS RESERVIOR. LEAK…
- 29 Aug 1998
Warning Light, illuminated
FORWARD CARGO WARNING LIGHT ILLUMINATED. *S/D* ADJUSTED TARGET.
- 9 Feb 1997
Air Distribution, odor
CREW REPORT RUBBER SMELL IN CABIN FROM ROW 17 AFT. CHECKED PSU ROW 17 AFT FOR WIRING DEFECTS. CHECKED GASPER FAN OUTLETS, GALLEY EQUIPMENT, LAVS, AIR…
- 19 Feb 1996
Valve, leaking
CREW REPORTS, SEVERAL PASSENGERS AND FLIGHT ATTENDANTS COMPLAIN OF HEAVY FUMES IN PASSENGER CABIN. NOSE STEERING METERING VALVE WAS FOUND LEAKING HYDRAULIC…
- 8 May 1995
Retract Mech, pinned
NOSE GEAR DID NOT RETRACT AFTER TAKE OFF. FOUND TOOL INSTALLED IN GEAR PIN DOWN LOCK HOLE. REMOVED TOOL AND INSPECTED, FOUND NO DAMAGE.