N906UA
1991 Boeing 737-522 standard FAA →
earlier registrations
1 past record
- 1991
service difficulty reports
32 reports
- 11 Sep 2012
Structure, damaged
A CATEGORY B MAJOR SHEETMETAL REPAIR WAS INSTALLED BETWEEN STA 312 & 330 & BETWEEN STR 20R AND 21R PER SRM REPAIR 31.
- 11 Sep 2012
Door Frame, cracked
FWD CARGO DOOR CUTOUT IS CRACKED IN TWO PLACES. FIRST CRACK IS ON AFT SIDE OF FRAME IS CRACKED IN TWO PLACES. FIRST CRACK IS ON AFT SIDE OF FRAME IN RADIUS…
- 6 Apr 2008
Coffeemaker, faulty
FLIGHT ATTENDANT NOTICED HOT SMELL AT FWD GALLEY. SMELL WAS ELECTRIC. THEN SPARK OCCURRED FROM COFFEE MARKER GRILL (HOT PLATE) THEN ARC AND PUFF OF SMOKE.
- 6 Apr 2008
Wire, faulty
FLIGHT ATTENDANT NOTICED HOT ODOR AT FWD GALLEY. SMELL WAS ELECTRIC. THEN SPARK OCCURRED FROM COFFEEMARKER GRILL (HOT PLATE) THEN ARC AND PUFF OF SMOKE. FOUND…
- 27 Mar 2008
Power Supply, inoperative
FLOOR EEL LIGHTS INOP FROM ROW 15 TO AFT GALLEY. REPLACED WET POWER FEEDER.
- 28 Jan 2008
Skin, damaged
FWD CARGO DOOR DAMAGED BY BELT LOADER. MAJOR REPAIR: REMOVED DAMAGED SKIN. INSTALLED REPAIR DOUBLER.
- 28 Jan 2008
Fire Warning, no test
CREW REPORTS ON PREFLT, NO BELL DURING FIRE TEST. APU HORN IN WHEEL WELL DOES COME ON.
- 28 Jan 2008
Module, malfunctioned
CREW REPORTS ON PREFLT, GET NO BELL DURING FIRE TEST. APU HORN IN WHEEL WELL DOES COME ON. FOUND FAULTY AURAL WARNING MODULE. REPLACED AURAL WARNING MODULE.
- 15 Nov 2007
Light, inoperative
EEL LIGHTS AT THE AFT SECTION OF THE CABIN INOP. REPLACED LIGHT ASSEMBLY
- 11 Aug 2007
Inverter, inoperative
THREE SEGMENTS OF EEL LIGHTS INOP AFT CABIN AFT GALLEY. REPLACED INVERTER. OPS CHECKS GOOD.
- 21 Apr 2007
Door Frame, cracked
FWD CARGO DOOR CUT OUT AFT FRAME IS CRACKED IN TWO PLACES. FIRST CRACK IS ON AFT SIDE OF FRAME IN RADIUS ADJACENT TO IB UPPER CORNER OF LOWER STOP FITTING,…
- 17 Apr 2007
Skin, damaged
SKIN DAMAGED BETWEEN BS 887 & BS 928 & FROM BUT NOT INCLUDING STRINGERS 20R AND 23R. [SUP 05-16-07] REPAIRED PER SRM 53-00-01.
- 17 Apr 2007
Frame, damaged
FRAME DAMAGED AT BS 908 BETWEEN STRINGERS 20R AND 23R. [SUP 05-16-07] MAJOR REPAIR: ACCOMPLISHED PER UA EVA 70187.
- 15 Feb 2007
Skin, damaged
FUSELAGE SKIN IS SCRATCHED AND DENTED APPROX 29 INCHES BELOW AFT END OF DOOR 1R OPENING. MAJOR REPAIR ACCOMPLISHED. MANUFACTURED DOUBLER, TRIPLER, FILLER AND…
- 15 Feb 2007
Skin, damaged
FUSELAGE SKIN IS SCRATCHED AND DENTED APPROX 29 INCHES BELOW AFT END OF DOOR 1R OPENING. MAJOR REPAIR ACCOMPLISHED. INSTALLED DOUBLER REPAIR AND ACCMP…
- 29 Jan 2007
Feeder Cable, faulty
EEL LIGHTS INOPERATIVE AFT OF ROW 15. REPLACED CABLE.
- 22 Nov 2005
Attach Fitting, corroded
LEFT HORIZONTAL STABILIZER FWD SPAR UPPER ATTACH LUG CORRODED. MAJOR REPAIR ACP'D PER AAR EA I050309 FOR LUG REWORK AND BUSHING REPLMTS.
- 22 Nov 2005
Attach Fitting, corroded
LEFT HORIZONTAL STABILIZER FWD SPAR LWR ATTACH FITTING CORRODED. MAJOR REPAIR ACP'D PER AAR EA I050309 FOR LUG REWORK AND BUSHING RPLMT'S.
- 24 May 2004
Skin, damaged
LEFT EXTERNAL FUSELAGE AFT OF L2 DOOR IS DAMAGED. REPAIR ACCOMPLISHED. INSTALLED DOUBLER/TRIPLER.
- 24 May 2004
Skin, dented
LEFT FUSE SKIN AND SIDE FRAME DENTED AT BS 178 WL 195. MAJOR REPAIR ACCOMPLISHED. REMOVED DAMAGE, INSTALLED FILLER AND DOUBLER.
- 21 May 2004
Frame, misinstalled
STATION 178 LT UPPER FRAME WL 243 NO EDGE DISTANCE. MAJOR REPAIR ACCOMPLISHED. FABRICATED & INSTALLED ANGLE SPLICE REPAIR.
- 18 May 2004
Shear Web, cracked
STA 194 SHEAR WEB AT STR 17 LT IS CRACKED. MAJOR REPAIR ACCOMPLISHED. REPLACED SHEAR WEB.
- 18 May 2004
Shear Web, cracked
STA 194 SHEAR WEB AT STR 17 RT IS CRACKED. MAJOR REPAIR ACCOMPLISHED. REPLACED SHEAR WEB.
- 12 May 2004
Frame, corroded
STA 380 FRAME HAS CORROSION FROM STR 28L TO 28R. *S/D* MAJOR REPAIR ACCOMPLISHED. INSTALLED REPAIR DOUBLER.
- 7 May 2004
Frame, cracked
CABIN BELOW FLOOR LEVEL, BS 616R I/B FRAME CHORD CRACKED AT OVERWING EXIT. MAJOR REPAIR ACCOMPLISHED. INSTALLED FILLER AND ANGLE.
- 3 Aug 2001
Control Unit, malfunctioned
UNSCHEDULED LANDING DUE TO FIRE BELL ACTIVATION. REMOVED AND REPLACED FIRE OVERHEAT DETECTOR CONTROL UNIT AND ENG/APU FIRE CONTROL MODULE. PERFORMED…
- 29 Jun 2000
Bulkhead, cracked
CRACK FOUND ON THE BODY STATION 178 BULKHEAD WEB. SUPPLEMENTAL DATA UPDATE CRACKS REPAIRED PER BOEING SRM 53-10-08.
- 14 Aug 1999
Oven, dirty
CABIN ODOR EXPERIENCED AT FL 280 IN DESCENT. OVENS AND LIGHTS TURNED OFF. ODOR SUBSIDED BUT STILL LINGERED. *S/D* OVEN UPPER BAFFLE WAS CONTAMINATED WITH…
- 7 Nov 1997
Sensor, bad
ON GEAR EXTENSION, LEFT MAIN LANDING GEAR RED LIGHT DID NOT EXTINGUISH. *S/D* FOUND LEFT MAIN LANDING GEAR DOWNLOCK SENSOR BAD. REPLACED LEFT MAIN LANDING…
- 23 Apr 1997
Controller, failed
RETURNED TO FIELD. UNABLE TO PRESSURIZE THE CABIN. *S/D* CABIN PRESSURE CONTROLLER FAILED. REPLACED CABIN PRESSURE CONTROLLER, OPS CHECK GOOD.
- 18 Sep 1996
Light, inoperative
FORWARD GALLEY EMERGENCY ESCAPE PATH LIGHTING INOP. REPLACED FORWARD GALLEY EMERGENCY LIGHT STRIP, CHECKS OK.
- 21 May 1996
Lamp, inoperative
DOOR ONE LEFT EMERGENCY LIGHT INOP. RELAMPED, CHECKS OK.