N904UA
2006 Benjamin D Eggers CHALLENGER II (kit Quad City Ultralight Acft Corp Challenger II) experimental, amateur built FAA →
registration
- 2006
earlier registrations
1 past record
- 1990
NTSB
- 29 Oct 1995
incident, San Francisco CA
service difficulty reports
32 reports
- 19 Mar 2008
Strip, loose
RTFL DUE TO A SMALL STRIP OF METAL HANGING FROM RIGHT WING. RE-BONDED METAL STRIP TO WING.
- 20 Feb 2008
Girt Bar, faulty
THE 2L GIRT BAR WON`T STAY IN HOLDER DE-ARM POSITION. REPACKED SLIDE.
- 27 Dec 2007
Bulb, inoperative
BULB BURNED OUT IN APU FIRE HANDLE. SAMC TEXT: CREW REPORTS 3 OF THE 4 BULBS ARE OPERATIONAL. SUSPECT BURNED OUT LIGHT BULB. REPLACED LAMP. AC OK FOR SERVICE.
- 7 Oct 2007
Light, faulty
FOUND EMERGENCY ESCAPE LIGHTING STRIP SEAT 20C STICKING OUT FROM CLEAR PLASTIC HOUSING. REPLACED LIGHT IN HOUSING.
- 10 Aug 2007
Power Strip, contaminated
FLOOR MOUNTED EEL LIGHTS INOP FROM ROW 11 TO AFT GALLEY. REPLACED WET POWER STRIP. REPLACED WET POWER STRIP.
- 16 Jul 2007
Slide, faulty
THREADING ON DOOR 2L SLIDE IS COMING APART. [08-07-07] STOWED THREADING BACK IN SLIDE FLAP.
- 18 Feb 2007
Control Cable, misrouted
LT WING AFT AILERON BUS CABLE CONTACTING MLG BEAM APPROX RSS 268 ON OUTBD SIDE OF GEAR BEAM. AILERON CABLES MIS-ROUTED. IMPROPER ROUTING OF CABLES. REROUTED…
- 18 Feb 2007
Gauge, obstructed
FOUND MAIN DECK AFT ENTRY DOOR SLIDE PRESS VIEW WINDOW FOGGY, GLAZED. REPLACED SLIDE.
- 18 Feb 2007
Door Frame, cracked
FOUND FORWARD CARGO DOOR AFT FRAME IS CRACKED AT TWO PLACES AT LOWER STOP FITTING. THE CRACK LOCATIONS ARE AS FOLLOWS: IN RADIUS OF FRAME AT INBOARD CORNER OF…
- 18 Jan 2007
Slide, faulty
FWD DOOR ESCAPE SLIDE IS FAULTY. SLIDE FAILED AD COMPLIANCE VERIFICATION TEST. REPLACED SLIDE.
- 27 Oct 2006
Unknown, unknown
AFTER GEAR RETRACTION, WHEN HANDLE WAS PLACED TO "OFF" POSITION, ALL GEAR EXTENDED. HANDLE THEN PLACED TO "DOWN" POSITION TO MATCH GEAR POSITION. HANDLE…
- 23 Oct 2006
Valve, unserviceable
LOW BOTTLE PRESSURE. A ONE-HOUR WATER BATH TEST WAS DONE TO THE VALVE AND IT DID NOT SHOW ANY LEAKS. VALVE WAS DISMANTLED AND ALL O-RINGS WERE IN GOOD…
- 23 Oct 2006
Valve, unserviceable
LOW BOTTLE PRESSURE.
- 26 Dec 2005
Light, inoperative
ESCAPE PATH LIGHTS INOP FROM ROW 14 BACK.
- 13 Jun 2005
Connector, inoperative
EEL LIGHTS OUT FROM ROW 15 BACK. *S/D* EEL LIGHT CONNECTORS WERE REMOVED, CLEANED AND REINSTALLED.
- 7 Jun 2004
Skin, damaged
SKIN DAMAGED AT STA 290 BETWEEN STR 20R AND 22R. REPLACED SKIN PANEL AND STR 21R AND 22R SEGMENTS.
- 6 Apr 2004
Splice, cracked
AFT CABIN NR 4L STR SPLICE IS CRACKED. MAJOR REPAIR ACCOMPLISHED. REPLACED STRINGER SPLICE.
- 30 Mar 2004
Splice, cracked
AFT CABIN NR 4R STR SPLICE IS CRACKED. MAJOR REPAIR ACCOMPLISHED. REPLACED STRINGER SPLICE.
- 30 Mar 2004
Web, cracked
STA 194 STR 17 LEFT HAS A CRACKED WEB. MAJOR REPAIR ACCOMPLISHED. REPLACED WEB.
- 30 Mar 2004
Web, cracked
STA 194 STR 17 RIGHT WEB CRACKED. MAJOR REPAIR ACCOMPLISHED. REPLACED WEB.
- 30 Mar 2004
Frame, cracked
INTERNAL FUSELAGE BS 616R FRAME WEB FORWARD FACE BELOW FLOOR LINE S16R LOCATED UNDER OVERWING EXIT RIGHT SIDE HAS CRACK APPROX 1 INCH LENGTH COMING FROM…
- 24 Mar 2004
Frame, cracked
FUSELAGE FRAME CRACKED STATION 520 STR 14R. MAJOR REPAIR ACCOMPLISHED. INSTALLED FRAME DOUBLER REPAIR.
- 24 Feb 2004
Bulkhead, damaged
NEED REPAIR TO BS 178 FWD BULKHEAD. MAJOR REPAIR ACCOMPLISHED. REPAIRED WEB ON FWD BULKHEAD AT BS 178, LBL 5.7, WL 212.
- 5 May 2003
Light, inoperative
EEL FLOOR LIGHTING INOPERATIVE FROM ROW 15ABC THROUGH AFT GALLEY. *S/D* REPLACED EEL 4 EACH LIGHTS AND EEL CABLE. OPS CHECK OK.
- 5 May 2003
Light, inoperative
EEL FLOOR LIGHTING INOPERATIVE FROM ROW 15 THROUGH AFT GALLEY. REPLACED 4 EEL LIGHTS AND ONE EEL CABLE. OPS CHECK OK.
- 1 Feb 2001
Indicator, failed
FLAP EXTENSION PROBLEM. *S/D* REPLACED FLAP POSITION INDICATOR.
- 1 Nov 2000
Bellcrank, broken
ON ARRIVAL FOUND RETRACT LINK FOR NR 3 (RT INBOARD KRUEGER FLAP) LEADING EDGE DEVICE BROKEN. UNABLE TO RETRACT FLAP. *S/D* BELLCRANK 65C26766-1 WAS REPLACED…
- 3 Jul 2000
Bulkhead, cracked
CRACK FOUND ON THE BODY STATION 178 BULKHEAD WEB. SUPPLEMENTAL DATA UPDATE CRACKS REPAIRED PER BOEING SRM 53-10-08.
- 18 May 1999
Relay, inoperative
UNSAFE GEAR DOWN INDICATION. *S/D* NO GEAR DOWN INDICATION WITH GEAR EXTENDED. REPLACED THE LANDING GEAR AIR/GROUND RELAY AND LIGHTS CIRCUIT BREAKER ITEM C404…
- 19 Jan 1996
Connector, loose
EMERGENCY FLOOR MOUNTED ESCAPE LIGHTING INOP ROWS 15 TO 20. RECONNECTED FLOOR MOUNTED EMERGENCY ESCAPE LIGHTING AT ROWS 15 THROUGH 20 TO POWER SOURCE AND…
- 18 Sep 1995
Switch, out of adjust
ABORTED TAKEOFF AT 90 KNOTS, DUE TO DOOR WARNING LIGHT. ADJUSTED DOOR SWITCH PER MM.
- 23 Aug 1995
Battery, discharged
EMERGENCY ESCAPE PATH LIGHTING ROW 4 TO ROW 14 AND LEFT HAND AND RIGHT HAND OVERWING EXIT LIGHTS INOP. REPLACED BATTERY PACKS, CHECKS OK.