N903AE
1991 Saab-Scania SAAB 340B standard FAA →
reservations
earlier registrations
1 past record
- 1991
service difficulty reports
14 reports
- 10 Sep 2003
Skin, damaged
AIRCRAFT SUSTAINED HAIL DAMAGE THAT NECESSITATED THE REPLACEMENT ON THE RIGHT HORIZONTAL STABILIZER UPPER SKIN. REMOVED DAMAGED UPPER SKIN. TRIMMED NEW SKIN…
- 26 Mar 2003
Control Unit, inoperative
DURING DESCENT AT 9000 MSL RT ENGINE HAD MINOR TORQUE ROLLBACK WITH NO IGNITION LIGHT. 1 MINUTE LATER RIGHT TORQU WENT OT 118 PERCENT AND RIGHT ITT WENT TO…
- 24 Feb 2003
Power Supply, inoperative
TYR - FLT 3670 - CREW REPORTED THE FLOOR PROXIMITY EMERGENCY LIGHTS AT ROWS 6, 7 AND 8 TO BE INOPERATIVE. MAINTENANCE REMOVED AND REPLACED THE EMERGENCY POWER…
- 21 Apr 2002
Hydraulic Line, failed
CREW REPORTED THE HYDRAULIC FAIL LIGHT ILLUMINATED ON THE CWP. CREW SELECTED TO OVERRIDE AND QUANTITY WENT TO ZERO. EMERGENCY WAS DECLARED AND CREW RETURNED…
- 15 Aug 2001
Smoke, detected
BOS - FLT 4893 - CREW REPORTED SMOKE IN COCKPIT DURING CRUISE FLIGHT. (M)
- 18 May 2001
Lamp, inoperative
DFW - FLT 3269 - CREW REPORTED THE EMERGENCY LIGHT AT ROW 10 IS INOPERATIVE. MAINTENANCE REPLACED THE BULB AT ROW 10. OPS CHECK WAS GOOD AND AIRCRAFT WAS…
- 11 Apr 2001
Pitot Line, contaminated
DFW - FLT 3299 - FIRST OFFICER AIRSPEED INDICATOR FAILED TAKEOFF. CLEANED WATER FROM F/O PITOT STATIC SYSTEM IAW AMM. OPS CHECK GOOD IAW AMM. AIRCRAFT…
- 30 Mar 2001
Pin, broken
FSM - FLT 3371 - CREW REPORTED NO DOWN AND LOCKED INDICATION FOR THE LEFT MLG, ALSO NO INTRANSIT OR GREEN LIGHT AND HYDRAULIC PUMP RUNS CONTINUOUSLY.…
- 28 Sep 2000
Lamp, burned out
LAW - DURING SCHEDULED MAINTENANCE OVERNIGHT, MAINTENANCE FOUND EMERGENCY LIGHT AT SEAT 11A INOPERATIVE. MAINTENANCE REMOVED AND REPLACED BULB AT SEAT 11A.…
- 4 Sep 2000
Battery Pack, inoperative
DFW - FLT 3385 - FLOOR PROXIMITY EMERGENCY LIGHTS NR 1 AND 4 ARE INOPERATIVE. MAINTENANCE REMOVED AND REPLACED BATTERY PACK. OPERATIONAL CHECK WAS GOOD AND…
- 6 Jul 2000
Cover, missing
DFW - FLT 3738 - EMERGENCY LIGHT COVER AT 9B MISSING ARROW. INSTALLED LENS PLACARD AS REQUIRED IAW SMM 33-50-20. OPS CHECK GOOD. (M)
- 21 Apr 2000
Bulb, failed
DFW - FLT 3252 - EMERGENCY LIGHT INOPERATIVE AT SEAT 11A. REMOVED AND REPLACED LAMP AT 11A. OPS CHECK GOOD. (M)
- 22 Jan 1999
Brake, leaking
BYW - FLT 5661 - WHEN PARKING AT THE GATE, THE HYDRAULIC CWP CAME ON. BOTH MAIN HYDRAULIC AND BRAKE PRESSURE INDICATION WENT TO ZERO. PUDDLE OF HYDRAULIC…
- 12 Oct 1998
Connector, disconnected
DFW - FLT 3598 - RIGHT MAIN LANDING DOWN AND LOCKED LIGHT DID NOT ILLUMINATE. INTRANSIT LIGHT WORKED NORMAL. UNEVENTFUL LANDING. MAINTENANCE PINNED THE GEAR…