N8971A
2004 Bombardier INC CL-600-2B19 standard FAA →
registration
- 2004
service difficulty reports
18 reports
- 6 Sep 2014
Battery Pack, discharged
NUMBER 2 EMER BATTERY PACK INOPERATIVE. R & R NR 2 EMER BATTERY PACK IAW AMM 33-51-04. OPERATIONS TESTED GOOD.
- 6 Mar 2014
Battery, discharged
FIRST OFFICER`S FLASHLIGHT BATTERY INDICATION LIGHT NOT BLINKING. R & R FLASHLIGHT BATTERY IAW AMM 25-61-00.
- 5 Jan 2014
Pbe, open
PBE BAG OPEN. REPLACED PBE IAW 35-30-01, OK FOR SERVICE.
- 3 Dec 2013
Life Vest, unserviceable
INFANT LIFE VEST HAS HOLE IN BAG. R & R INFANT LIFE VEST IAW PA 25-096A.
- 19 Jun 2013
Stall Warning, contaminated
STALL FAIL CAUTION MESSAGE WITH A IAS FLAG ON ISIS AND A YELLOW SSEC MESSAGE. REMOVED WATER FROM STANDBY SYSTEM, TRAP BLEW OUT STANDBY SYSTEM WITH NIT.…
- 27 May 2013
Life Vest, unserviceable
INFANT LIFE VEST TORN. R & R INFANT LIFE VEST IAW PA 25-096A.
- 12 Apr 2013
Structure, damaged
LIGHTNING STRIKE DAMAGE FOUND ON RIGHT ELEVATOR (P/N 601R24025-2, S/N SB0181) BETWEEN RIB 11 AND RIB. REPAIRED IAW BOMBARDIER REO 601R-55-21-390.
- 3 Oct 2012
Fitting, cracked
FLOORBEAM ANGLE CLIP FITTING AT FS 461 JUST OUTBOARD OF RIGHT AISLE SEAT TRACK IS CRACKED. REMOVED AND REPLACED IAW SRM 51-42-21.
- 29 Sep 2012
Skin, dented
LEFT INBOARD FLAP LOWER SKIN DENTED APPROXIMATELY 4 INCHES OUTBOARD OF INBOARD EDGE. REPAIRED IAW SRM 57-52-00 FIGURE 2.
- 26 Sep 2012
Hinge, worn
PAX DOOR HINGE LOWER HALF WORN. REPAIRED IAW SRM 53-21-23.
- 26 Sep 2012
Intercostal, cracked
LBL 9 AS FS 461 INTERCOSTAL CRACKED. REPLACED IAW SRM 51-42-21/51-42-06.
- 26 Sep 2012
Attach Fitting, cracked
FS 280 ATTACHMENT CLIPS TO RBL 9 AND LBL 9 BEAMS ARE CRACKED. REPLACED IAW SRM 51-42-06/51-42-21.
- 26 Sep 2012
Beam, cracked
FS 280 BEAM AT RBL 12 CRACKED ON LOWER FLANGE. REPAIRED IAW BOMBARDIER REO 601R-53-11-171.
- 26 Sep 2012
Bulkhead, damaged
AFT PRESSURE BULKHEAD AT FS 621 FWD FACE HAS 7 AREAS OF FASTENER DAMAGE TO WEB. DETERMINED WITHIN LIMITS PER SRM 53-00-00 TR53-27.
- 25 Sep 2012
Fitting, cracked
INTERCOSTAL FITTING ON UPPER PRESSURE FLOOR AT RBL 9 AND FS 461 IS CRACKED. REMOVED AND REPLACED IAW SRM 51-42-21.
- 24 Sep 2012
Bulkhead, damaged
REPAIRED FS 621 PRESSURE BULKHEAD WEB IAW BOMBARDIER REO 601R-53-61-1230.
- 21 May 2012
Light, broken
EMERGENCY FLOODLIGHT BROKEN IN ENTRYWAY. REPLACED EMERGENCY FLOODLIGHT ASSY P/N BR9279-232 PER CRJ200 AMM 33-51-19. OPS CHECKED GOOD PER AMM 33-51-00.
- 5 Nov 2004
Detector, malfunctioned
FLAP FAIL MESSAGE ON TAXI WHILE RAISING FLAPS. REMOVED AND REPLACED SKEW DETECTION UNIT.