N896AA
Boeing 727-200 FAA →
earlier registrations
1 past record
service difficulty reports
33 reports
- 11 Feb 2000
Connector, damaged
DFW - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT ESCAPE PATH LIGHTS AT FORWARD GALLEY INOPERATIVE. REPLACED EMERGENCY EXIT ESCAPE PATH LIGHT CONNECTOR.…
- 12 Apr 1999
Light, inoperative
TUL - DURING OVERNIGHT MAINTENANCE, CO-PILOTS OVERHEAD EMERGENCY EXIT LIGHT ASSEMBLY. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)
- 18 Dec 1998
Strap, corroded
TUL - FOUND FORWARD 8 INCHES OF STRAP CORRODED, EXFOLIATION THROUGH THE TAPERED STRAP. REMOVED OLD TAPERED STRAP P/N 65-56181-6 AND INSTALLED NEW TAPERED…
- 18 Dec 1998
Stringer, corroded
TUL - FOUND STRINGER 28R STATION 480 CORRODED. INSTALLED STRINGER REPAIR PER SRM 53-10-3. (M)
- 18 Dec 1998
Skin, corroded
TUL - FOUND STATION 500-504 AFT SIDE FRAME OUTBOARD STRINGER 27L SKIN CORRODED UNDER LEVELING COMPOUND (MARKED). INSTALLED SKIN REPAIR PER ESO 11697, DATED…
- 18 Dec 1998
Skin, corroded
TUL - FOUND STATION 482-492 OUTBOARD STRINGER 28R RBL 12 INCHES RBL THROUGH 13 INCHES SKIN CORRODED BELOW INTERCOSTAL LOWER ATTACH ANGLE (MARKED). INSTALLED…
- 18 Dec 1998
Stringer, corroded
TUL - FOUND CORROSION INSIDE STRINGER 27R STATION 720F PLUS 3 INCHES TO 740. REPAIRED STRINGER PER SRM 53-10-3 FIG 1 PAGE 4B STRINGER 27R STATION 720F PLUS 3…
- 18 Dec 1998
Stringer, corroded
TUL - FUOND CORROSION ON BOTTOM SIDE OF STRINGER 27 LEFT STATION 500. INSTALLED STRINGER REPAIR PER SRM 53-10-3. (M)
- 17 Dec 1998
Shear Tie, corroded
TUL - FOUND SHEAR TIE CORRODED UNDER LEVELING COMPOUND OUTBOARD OF STRINGER 27L. INSTALLED NEW SHEAR TIE PER SRM 51-10-1. (M)
- 16 Dec 1998
Shear Tie, corroded
TUL - FOUND FORWARD SIDE STATION 600 OUTBOARD STRINGER 27L TO 26L SHEAR TIE CORRODED. INSTALLED NEW SHEAR TIE PER SRM 51-10-1. (M)
- 16 Dec 1998
Strap, corroded
TUL - FOUND CORROSION ON STRAP AT STATION 1177 LEFT AFT LAVATORY AFT SPLASH LIP AREA AT CABLE FLOOR ATTACH FITTING AREA. FABRICATED AND INSTALLED REPAIR…
- 16 Dec 1998
Pan, corroded
TUL - FOUND HEAVY CORROSION ON BOTTOM OF FLOOR PAN (CABIN) 6 INCHES FORWARD OF BS 1183 LBL 26, EXTENDING 6 INCHES FORWARD AND 6 INCHES OUTBOARD, GOING OVER…
- 16 Dec 1998
Stringer, corroded
TUL - FOUND CORROSION INSIDE STRINGER 26R STATION 476 - STATION 480. INSTALLED STRINGER REPAIR PER SRM 53-10-3. (M)
- 14 Dec 1998
Stringer, corroded
TUL - FOUND CORROSION INSIDE OF STRINGER 27L STATION 720D PLUS 15 INCHES - 17 INCHES BELOW ELECTRICAL WIRE BUNDLE CLAMP. CORROSION REMOVAL WAS BEYOND LIMITS.…
- 14 Dec 1998
Skin, corroded
TUL - SKIN BULGED STATION 515 TO STATION 517 STRINGER 26R INBOARD TO INTERCOSTAL. CUT OUT DAMAGED AREA 8 INCH BY 2 INCH BELOW STRINGER 26R STATION 510 TO…
- 9 Dec 1998
Stiffener, cracked
TUL - FOUND CRACK IN STIFFENER JUST FORWARD AND BELOW LEFT FORWARD TENSION TIE BOLT. REPLACED STIFFENER WITH NEW STIFFENER. (M)
- 9 Dec 1998
Floorbeam, corroded
TUL - FOUND TOP OF FLOORBEAM CORRODED STATION 380 RBL 14 TO RBL 67. REMOVED CORROSION FROM TOP OF FLOORBEAM, AREA AT RBL 33.5 WAS BEYOND LIMITS. FABRICATED…
- 9 Dec 1998
Stringer, corroded
TUL - FOUND STRINGER 27L CORRODED INSIDE STATION 720E PLUS 5 INCH THROUGH 720E PLUS 7 INCH. REMOVED DAMAGED STRINGER 27L FROM STATION 720E PLUS 10 INCHES AND…
- 21 Sep 1998
Wire, broken
DFW - DURING OVERNIGHT MAINTENANCE, R2 DOOR EMERGENCY EXIT FLOOR PATH LIGHTING JUMPER WIRE BROKEN. REPLACED R2 DOOR EMERGENCY EXIT FLOOR PATH LIGHT JUMPER…
- 1 Sep 1998
Light, inoperative
DFW - DURING OVERNIGHT MAINTENANCE, FIRST CLASS EMERGENCY EXIT FLOOR PATH LIGHT HAS ONE LIGHT INOPERATIVE. REPLACED EMERGENCY EXIT FLOOR PATH LIGHT STRIP.…
- 4 Feb 1998
Skin, cracked
TUL - FUSELAGE SKIN CRACKED AT FORWARD ENTRY DOOR LOWER HINGE CUT-OUT. INSTALLED REPAIR DOUBLER PER SB 727-53-0198. TST: 48,140 HOURS. CYCLES: 23,835. (X)
- 5 May 1997
Skin, dented
TUL - DENT IN SKIN. INSTALLED DOUBLER PER SRM 53-30-3 FIG 24. TST: 48,140 HOURS. CYCLES: 23,835. (X)
- 22 Jan 1997
Stringer, corroded
TUL - FOUND CORROSION IN CHANNEL STRINGER 28 LEFT, STATION 480-500. CUT OUT DAMAGED SECTION OF STRINGER. INSTALLED REPAIR PER SRM 53-10-3. (M)
- 22 Jan 1997
Stringer, corroded
TUL - FOUND CORROSION ON STRINGER 30, BETWEEN STATION 1030-1050. REPAIRED PER SRM 53-10-3, FINISHED INSTALLING FASTENERS FIG 1. (M)
- 22 Jan 1997
Skin, corroded
TUL - FOUND CORROSION ON SKIN OUTBOARD SIDE STRINGER 28L, FORWARD OF 580. INSTALLED DOUBLER PER SRM 53-30-3, FIG 3. (M)
- 22 Jan 1997
Stringer, corroded
TUL - FOUND CORROSION INSIDE STRINGER 27R AT BS 720D. INSTALLED STRINGER REPAIR PER SRM 53-10-03 FIG 1. (M)
- 22 Jan 1997
Shear Tie, corroded
TUL - FOUND CORROSION ON SHEAR TIE STATION 620 OUTBOARD OF STRINGER 26L. INSTALLED NEW SHEAR TIE SRM 51-10-1. (M)
- 1 Dec 1996
Light, defective
DFW - DURING OVERNIGHT CHECK, AFT THREE FOOT SECTION OF EMERGENCY FLOOR LIGHTS IN COACH INOPERATIVE. REPLACED AFT THREE FOOT SECTION OF EMERGENCY FLOOR LIGHT…
- 10 Mar 1996
Sensor, defective
DFW - FLT NR 1089 - EN ROUTE PHL/DFW DURING CRUISE AT FL 310, RIGHT MAIN LANDING GEAR RED WARNING LIGHT ILLUMINATED WITH GEAR HANDLE IN OFF POSITION. CYCLED…
- 13 Feb 1996
Doubler, corroded
TUL - CORROSION ON SKIN DOUBLER AND TRIPPLER AROUND AFT LAV SERVICE PAN STA 1068-1183, STR 21-23. INSTALLED DOUBLER PER SRM 53-30-4, PAGE 40 AND SRM 53-30-3.…
- 8 May 1995
Accessory Unit, defective
SJU - FLT 2009 - AFTER TAKEOFF LEFT MAIN LANDING GEAR DOOR LIGHT REMAINED ILLUMINATED AFTER GEAR RETRACTION. LANDED SJU WITHOUT INCIDENT. REPLACED LANDING…
- 1 Apr 1995
Eng Fire Loop, defective
MIA - FLT 945 - DURING CRUISE, EN ROUTE MIA-PHL FIRE BELL SOUNDED WITH NO LIGHTS. ACCOMPLISHED ABNORMAL PROCEDURES, NO FIRE INDICATION. AFTER BELL SOUNDED…
- 20 Feb 1995
Wire, broken
DFW - DURING OVERNIGHT CHECK, EMERGENCY FLOOR LIGHTS IN AFT SECTION OF MAIN CABIN INOPERATIVE. REPAIRED BROKEN/SHORTED WIRING AT AFT CABIN EMERGENCY FLOOR…