N895AA
Boeing 727-223 FAA →
earlier registrations
2 past records
service difficulty reports
20 reports
- 2 Nov 2000
Beam, cracked
DURING C-CHECK INSPECTION, FOUND A .75 INCH CRACK IN THE WEB AREA AFT SIDE OF THE LEFT MAIN LANDING GEAR SUPPORT BEAM. PART TOTAL TIME AND CYCLES ARE UNKNOWN,…
- 1 Apr 2000
Light, inoperative
DFW - DURING OVERNIGHT MAINTENANCE, AFT AIRSTAIRS EMERGENCY EXIT LIGHT INOPERATIVE. REPLACED AFT AIRSTAIRS EMERGENCY EXIT LIGHT ASSY. SYSTEM GROUND CHECKED…
- 14 Jan 2000
Light, inoperative
DFW - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT AIRSTAIR OVERHEAD LIGHT INOPERATIVE. REPLACED EMERGENCY EXIT AIRSTAIR OVERHEAD LIGHT. SYSTEM GROUND CHECKED…
- 28 Nov 1999
Switch, failed
PHL - FLT 0274 - AFTER TAKEOFF, MIA/PHL, RIGHT GEAR DURING RETRACTION INDICATED UNSAFE INDICATION. RIGHT GEAR DOOR LIGHT ON FLIGHT ENGINEER'S PANEL WAS…
- 25 Nov 1999
Switch, failed
TPA - FLT 1486 - DURING LANDING WHEN GEAR WAS EXTENDED, THE LEFT GEAR DOOR ANNUNCIATED ON THE FLIGHT ENGINEER'S PANEL AND THE RED DOOR LIGHT REMAINED…
- 18 Apr 1999
Stringer, corroded
TUL - FOUND CORROSION ON STRINGER 26L AT STATION 481 TO 486. CUT OUT CORRODED END OF STRINGER AND INSTALLED EXTENDED PRODUCTION SPLICE PER ESO11697 3/17/99. (M)
- 19 Mar 1999
Angle, corroded
TUL - FOUND CORROSION ON UPPER AFT SUPPORT ANGLE IN RIGHT TRUNNION BOX (MARKED) INBOARD OF SWIVEL VALVE REF E58 NR 3146190. REMOVED CORROSION ON UPPER AFT…
- 16 Mar 1999
Frame, cracked
TUL - FOUND STATION 910 UPLOCK FRAME CRACKED ON FORWARD FLANGE. STOP DRILLED CRACK AND INSTALLED REPAIR PER SRM 53-10-2 PAGE 28. (M)
- 16 Mar 1999
Skin, dented
TUL - FOUND STATION 1090, 3 INCH BELOW STRINGER 17 LT HAS DEEP DENT IN FUSE SKIN. INSTALLED REPAIR DOUBLER PER SRM 53-30-3, AFTER CUT OUT DAMAGED AREA. (M)
- 15 Mar 1999
Stringer, corroded
TUL - FOUND CORROSION ON STRINGER 28R AT STATION 560. INSTALLED STRINGER REPAIR AT STATION 554 AND STATION 566 IAW SRM 53-10-3. (M)
- 15 Mar 1999
Stringer, corroded
TUL - FOUND CORROSION ON STRINGER 27L AT STATION 495. CUT AND REMOVED DAMAGED SECTION OF STRINGER 27L FROM STATION 491 TO 509 MANUFACTURED AND INSTALLED…
- 12 Mar 1999
Frame, dented
TUL - FOUND BELL FRAME AT BS 1050 DENTED. REMOVED DENTED PORTION OF BELL FRAME AND INSTALLED REPAIR SECTION PER SRM 53-10-4. (M)
- 11 Mar 1999
Spar, corroded
TUL - FOUND CORROSION ON FRONT SPAR LOWER CHORD, LOWER WING L/E PANEL LAND AT NR 3 SLAT INBOARD TRACK. BLENDED OUT CORROSION. INSTALLED REPAIR STRAP PER B727…
- 25 Nov 1998
Wire, failed
DFW - DURING OVERNIGHT MAINTENANCE CHECK, EMERGENCY EXIT FLOOR PATH LIGHTING IN COACH CABIN INOPERATIVE. REPAIRED WIRING IN COACH CABIN. SYSTEM GROUND CHECKED…
- 27 May 1998
Light, inoperative
DFW - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT LIGHT AT BOTTOM OF AFT STAIRS INOPERATIVE. REPLACED EMERGENCY EXIT LIGHT ASSEMBLY AT THE BOTTOM OF AFT…
- 30 Apr 1997
Stringer, corroded
TUL - CORROSION INSIDE STR 29L AT BS 1113. REMOVED CORROSION PER 51-10-06 AND REPLACED PER SRM 53-10-3 FIG NR 1. TST: 46,083 HOURS. CYCLES: 23,083. (X)
- 30 Apr 1997
Shear Tie, corroded
TUL - FOUND CORRODED SHEAR TIE AT BS 720. REMOVED SHEAR TIE AND CORROSION FROM SURROUNDING AREA PER SRM 51-10-6 AND INSTALLED FABRICATED SHEAR TIE PER SRM…
- 25 Mar 1997
Connector, broken
MIA - DURING OVERNIGHT CHECK, EMERGENCY FLOOR LIGHTS INOPERATIVE THROUGH OUT MAIN CABIN. REPLACED BROKEN EMERGENCY FLOOR LIGHT STRIP CONNECTORS BY AFT…
- 26 Jan 1997
Harness, defective
DFW - FLT 1528 - AFTER TAKEOFF MEX WHEN LANDING GEAR RETRACTED, NO RED NOSE LANDING GEAR INDICATION ON INSTRUMENT PANEL AS GEAR RETRACTED. ALL INDICATIONS ON…
- 20 Feb 1996
Connector, loose
MIA - DURING OVERNIGHT CHECK, EMERGENCY FLOOR LIGHTS BETWEEN PAX SEAT ROWS 16D AND 22D INOPERATIVE. RESECURED LOOSE EMERGENCY FLOOR LIGHT CONNECTOR BY PAX…