- 20 Apr 2013
Battery Pack, discharged
DURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT…
- 3 Jan 2013
Battery, discharged
DURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT…
- 19 Dec 2012
Battery, discharged
DURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT…
- 27 Apr 2012
Battery, discharged
DURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT…
- 19 Dec 2011
Power Supply, inoperative
DURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT…
- 22 Sep 2011
Battery, discharged
DURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT…
- 20 Jun 2011
Battery, discharged
DURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT…
- 23 Apr 2010
Light, inoperative
IT HAS BEEN REPORTED BY THE FLIGHT CREW THE EMERGENCY EVACUATION LIGHTING SYSTEM HAS BEEN FOUND TO BE DEFECTIVE. AISLE LIGHT WIRES HAVE BECOME EXPOSED, FLOOR…
- 26 Mar 2010
Battery Pack, discharged
DURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT…
- 27 Jun 2009
Battery Pack, inoperative
DURING A ROUTINE OVERNIGHT SERVICE CHECK INSP, MX REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYS WOULD NOT TEST. MX REMOVED AND REPLACED THE…
- 18 Jun 2009
Battery Pack, inoperative
DURING A ROUTINE OVERNIGHT SERVICE CHECK INSP REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYS WOULD NOT TEST. MX PERSONNEL REMOVED AND REPLACED…
- 14 May 2009
Seat Track, corroded
NR 6 SEAT TRACK CORRODED AT SPLICE AT STATION 798 REF E58 6278336. REPLACED SECTION OF NR 6 SEAT TRACK FROM STATION 798 TO STATION 909 PER SRM 53-05 FIG 4…
- 14 May 2009
Shear Tie, cracked
SHEAR TIE CRACKED AT BOTTOM END BETWEEN L13-L14, LEFT AT STATION 1380. REPAIRED PER ESO 80559 / AARD 53-10-20, REF E58 6278265.
- 12 May 2009
Shear Tie, cracked
SHEAR TIE CRACKED AT STATION 1401 BELOW APU EXHAUST DUCT.
- 16 Apr 2009
Battery Pack, inoperative
DURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT…
- 26 Feb 2009
Battery Pack, inoperative
DURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT…
- 21 Aug 2008
Battery Pack, failed
DURING A ROUTINE OVERNIGHT SERVICE CHECK, INSP REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINT REMOVED AND REPLACED THE…
- 23 Jul 2008
Battery, failed
DURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT…
- 24 Oct 2007
Longeron, corroded
FOUND LONGERON AT STA 1155 CORRODED. REMOVED AND REPLACED LONGERON P/N 5936037-501 AT STATION 1155 L-29R IAW SRM 51-30-05 AND 51-30-02.
- 24 Oct 2007
Frame, corroded
FRAME AT STA 1155 CORRODED. REMOVED AND REPLACED FRAME P/N 5AA9936073-9 AT STATION 1155 L27R AND 28R IAW SRM 51-30-05 AND 51-30-02.
- 26 Sep 2007
Shear Tie, damaged
AFT CARGO COMPARTMENT SHEAR TIE HAS CORROSION AT STATION 1150 BETWEEN L29R AND L30R. FABRICATED FORMER FROM 7075-T6 .063 AND REPAIR SPLICE FROM 7075-T6 .063…
- 29 Aug 2007
Structure, cracked
HORIZONTAL STABILIZER LEFT SIDE CRACKED AT REAR UPPER INBOARD SIDE BETWEEN UPPER AND LOWER BOLTS AT STATION XH8.50. HORIZONTAL STABILIZER SENT TO VENDOR FOR…
- 28 Aug 2007
Skin, gouged
AFT CARGO DOOR HAS A GOUGE BELOW DOOR HANDLE. ORIGINAL SKIN THICKNESS .050". REMOVED .011", OUT OF LIMITS PER SRM 53-04 FIG 38. AREA MEASURES 2.7" BY 1.7" BY…
- 20 Aug 2007
Skin, gouged
AFT CARGO PIT DOOR HAS GOUGE ON 3RD STRINGER FROM BOTTOM OF DOOR. ORIGINAL SKIN THICKNESS .050". REMOVED .015" OUT OF LIMITS PER SRM 53-04 FIG 38. AREA…