N892AA
Vans Aircraft INC RV-12IS FAA →
registration
NTSB
- 13 Dec 1991
incident, St. Thomas
service difficulty reports
37 reports
- 21 May 2001
Connector, inoperative
DFW - DURING OVERNIGHT MAINTENANCE, COACH EMERGENCY ESCAPE PATH LIGHTS INOPERATIVE. SECURED CONNECTOR FOR EMERGENCY ESCAPE PATH LIGHTS. SYSTEM GROUND CHECKED…
- 25 Mar 2001
Stringer, cracked
TUL - FOUND STRINGER 18A CRACKED ABOVE AND BELOW FLANGE AT STATION 940 RIGHT. REMOVED AND REPLACED STRINGER 18A RIGHT PER SERVICE BULLETIN 727-53-0172. (M)
- 21 Mar 2001
Structure, corroded
TUL - FOUND RIGHT WING LOWER LEADING EDGE CHORD EXTENSION HAS HEAVY AREA OF CORROSION, UNDER INBOARD END OF STUB ACCESS. REMOVED CORROSION AND REPAIRED PER…
- 19 Mar 2001
Support Bracket, corroded
TUL - FOUND STRINGER TO FRAME SUPPORT BRACKET (U-CHANNEL) CORRODED ON BOTTOM JUST ABOVE BELLY SKIN STRINGER 27R STATION 560. REMOVED CORROSION, ALODINED AND…
- 19 Mar 2001
Shear Tie, corroded
TUL - FOUND CORROSION ON SHEAR TIE STATION 540 STRINGER 27R. REMOVED CORROSION, ALODINED AND PRIMED PER MM 51-20-0. (M)
- 24 Nov 2000
Light, inoperative
DFW - FOUND DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT LIGHT AT AFT LEFT SIDE SERVICE DOOR INOPERATIVE. REPLACED EMERGENCY EXIT LIGHT ASSEMBLY AT AFT LEFT…
- 31 Aug 2000
Contactor, dirty
DFW DURING OVERNIGHT MAINTENANCE AFT STAIRWAY EMERGENCY EXIT LIGHT INOPERATIVE. CLEANED EMERGENCY EXIT LIGHT BATTERY CONTACTS. SYSTEM GROUND CHECKED NORMAL…
- 23 Aug 2000
Duct, ruptured
MIA - FLT 929 - SEVEN MINUTES AFTER TAKEOFF NR 3 FIRE LIGHT ILLUMINATED. THROTTLE CONTINUED TO RUN FORWARD AFTER BEING PULLED BACK AND WOULD NOT STAY AT IDLE.…
- 28 Mar 2000
Floorbeam, misdrilled
TUL - PARTIALLY DRILLED HOLE IN UPPER FLANGE OF FLOORBEAM STATION 480 RBL 45. REMOVED DAMAGE IN UPPER FLANGE OF FLOORBEAM AND REPAIRED PER ESO 11697, DATED…
- 28 Mar 2000
Stringer, corroded
TUL - FOUND CORROSION ON STRINGER 27R, STATION 720B PLUS 14-17 INCHES. INSTALLED STRINGER REPAIR PER SRM 53-10-3. (M)
- 28 Mar 2000
Frame, dented
TUL - FUSELAGE BELT FRAME DENTED AT STATION 700, STRINGER 24R. INSTALLED REPAIR TO TYPICAL FORMED SECTION PER SRM 51-40-3. USING 7075T6, .063, 12 FASTENERS…
- 28 Mar 2000
Frame, dented
TUL - STATION 600 FRAME HAS 4 DENTS, STRINGER 22L 24L. REPLACED SECTION OF BELL FRAME PER SRM 51-40-3. (M)
- 28 Mar 2000
Frame, dented
TUL - BELT FRAME DENTED AT STATION 660 AND STRINGER 24L. INSTALLED TYPICAL FORMED SECTION REPAIR PER 51-40-8, 5 INCH LONG REPAIR, MATERIAL 7075-T6, .063 INCH…
- 28 Mar 2000
Floorbeam, corroded
TUL - FLOORBEAM UPPER CHORD CORRODED AT STATION 344, LBL 28 TO RBL 10. SPLICED IN NEW T-CAP PER SRM 53-10-8. (M)
- 20 Feb 2000
Casting, damaged
TUL - NR 4 SPOILER ACT SUPPORT CASTING, BOTH LOWER REAR SPAR ATTACHMENTS WORKING LOOSE INBOARD SIDE IS EXTRUDING CAST. NR 4 SPOILER ACTUATOR FITTING ATTACH…
- 28 Jan 2000
Frame, cracked
TUL - FOUND BELT FRAME CRACKED AT FASTENER AT STRINGER 14R STATION 800. REPAIRED CRACKED ANGLE AT BELT FRAME LOCATION PER 51-40-4 FIGURE NR 1 SHEET 5. (M)
- 25 Jan 2000
Casting, corroded
TUL - RIGHT WING AFT BOTTLE BOTL CASTING HAS SEVERAL DEEP PITS IN AFT BUSHING AREA AT CASTING. BORED RIGHT AFT CASTING TO REMOVED CORROSION PER ESO 11697…
- 21 Jan 2000
Frame, bent
TUL - BELT FRAME BENT STATION 520 AT STRINGER 24L. INSTALLED REPAIR PER 51-40-3 WITH 7075 .063 11 INCHES LONG, 2 ROWS OF FASTENERS. (M)
- 21 Jan 2000
Skin, cracked
TUL - FOUND CRACK IN FUSELAGE SKIN FORWARD OF FORWARD ENTRY DOOR LOWER HINGE CUTOUT. CRACK REMOVED BY TRIMMING. REPAIR DOUBLER INSTALLED PER SERVICE BULLETIN…
- 20 Jan 2000
Skin, damaged
TUL - STATION 1070 STRINGER 18L SKIN DAMAGED AND FASTENER HEADS DAMAGED. BURNISHED OUT DAMAGE AND INSTALLED DOUBLER PER SRM 53-30-3 FIG 1. (M)
- 19 Jan 2000
Floorbeam, corroded
TUL - STATION 1110 FLOORBEAM TOP CORRODED BL 0 - LBL 4. CUT OUT DAMAGED AREA AND INSTALLED DOUBLER PER SRM 53-10-8. (M)
- 13 Jan 2000
Stringer, corroded
TUL - FOUND CORROSION ALONG BOTTOM OF STRINGER 30 FROM STATION 1050-1070. REMOVED CORROSION. ALODINED AND PRIMED. REINSTALLED FASTENERS. REMOVED FOR CORROSION…
- 12 Sep 1999
Wire, disconnected
DFW - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT FLOOR PATH LIGHT LIGHTING IN CABIN INOPERATIVE. RECONNECTED WIRING TO EMERGENCY EXIT FLOOR PATH LIGHTING.…
- 4 Aug 1999
Wire, out of position
DFW - DURING OVERNIGHT MAINTENANCE, EMERGENCY OVERHEAD AISLE LIGHT AT ROW 9 INOPERATIVE. REPOSITIONED WIRE ON BATTERY TABS. SYSTEM GROUND CHECKED NORMAL…
- 10 Jun 1999
Terminal, broken
DFW - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT FLOOR PATH LIGHTING AFT CABIN INOPERATIVE. REPLACED SEVERAL TERMINAL ENDS ON EMERGENCY EXIT PATH LIGHTING.…
- 10 Jun 1999
Light, defective
DFW - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT AFT STAIR LIGHT INOPERATIVE. REPLACED EMERGENCY EXIT LIGHT ASSEMBLY. SYSTEM GORUND CHECKED, NORMAL…
- 2 Feb 1999
Spar, corroded
TUL - FORWARD LOWER SPAR CHORD VERTICAL LEG HAS CORROSION BELOW NR 7 SLAT ACTUATOR. REPAIRED PER ESO 11697 DATED 1-25-99. (M)
- 21 Mar 1997
Stringer, corroded
TUL - FOUND STRINGER 29R HAS HEAVY CORROSION AT STATION 950E. CUT OUT DAMAGED SECTION OF STRINGER AND REPAIRED PER AARD 53-10-03-1. (M)
- 21 Mar 1997
Skin, corroded
TUL - FOUND CORROSION ON SKIN JUST AFT OF STATION 660, BETWEEN STRINGER 28L - 28R. REMOVED DAMAGE AND INSTALLED DOUBLER PER SRM 53-30-3 FIG 3. (M)
- 21 Mar 1997
Stringer, corroded
TUL - FOUND CORROSION INSIDE STRINGER 27 RT, STATION 626. INSTALLED STRINGER REPAIR PER SRM 53-10-3. (M)
- 23 Jan 1997
Metering Valve, leaking
MEX - FLT 1528 - AFTER GATE DEPARTURE DURING TAXI OUT, DIMINISHED BRAKING ACTION NOTED. AIRCRAFT RETURNED TO GATE. REPLACED LEFT MAIN LANDING GEAR BRAKE…
- 18 Jul 1996
Module, defective
DFW - DURING OVERNIGHT CHECK, FOUND EMERGENCY EXIT LIGHT, OVER RIGHT WING, INOPERATIVE. REPLACED EMERGENCY EXIT LIGHT MODULE. SYSTEM GROUND CHECKED NORMAL…
- 3 Apr 1996
Stringer, cracked
TUL - FOUND .3125 INCH CRACK IN SUPPORT STRINGER BETWEEN VERTICAL BEAMS, STATION 1183 RBL 36 WL 270. INSTALLED NEW STRINGER AT RBL 36 WL 270 STATION 1183. (M)
- 9 Dec 1995
Connector, broken
MIA - DURING OVERNIGHT CHECK, EMERGENCY FLOOR LIGHTS BETWEEN PAX SEAT ROWS 6 AND 16 INOPERATIVE. REPLACED BROKEN EMERGENCY FLOOR LIGHT CONNECTOR BY PAX SEAT…
- 20 Nov 1995
Screws, worn
SJU - FLT 0212 - AIRCRAFT WAS EN ROUTE STX/MIA, DUMPED FUEL AND DIVERTED TO SJU. EN ROUTE DURING CRUISE, FUEL SEEPAGE NOTED FROM AREA OF RT OUTBOARD AILERON.…
- 6 Feb 1995
Eel Strip, defective
LGA - DURING OVERNIGHT MAINTENANCE EMERGENCY EXIT FLOOR PATH LIGHTS INOPERATIVE IN COACH. REPLACED EMERGENCY EXIT FLOOR PATH LIGHT STRIP. SYSTEM GROUND CHECKS…
- 6 Feb 1995
Eel Connector, failed
LGA - DURING OVERNIGHT MAINTENANCE EMERGENCY EXIT FLOOR PATH LIGHTS INOPERATIVE AT AFT GALLEY AND REAR DOOR. REPAIRED EMERGENCY EXIT FLOOR PATH CONNECTOR AT…