N878GA
Gulfstream Aerospace Corp GVIII-G800 FAA →
registration
earlier registrations
1 past record
- 1996
service difficulty reports
105 reports
- 2 Feb 2018
Support Bracket, cracked
CANTED FRAME 1463 AFT FACE LONGERON 11R CANISTER SUPPORT BRACKET CRACKED. REPAIRED SUMP SUPPORT BRACKET IAW SRM 53-01 FIG 2.
- 2 Feb 2018
Attach Angle, cracked
FIRST FRAME AFT OF 1338 CNTR HORSE SHOE PANEL ATACH ANGLE CRACKED. REPLACED ATTACH ANGLE IAW SRM 51-30-2 FIG 3 & 51-30-5 FIG 7.
- 1 Feb 2018
Trim Panel, broken
AFT VENTRAL OVERHEAD PANEL TRIM BROKEN ON BOTH SIDES. REPLACED TRIM IAW SRM51-30-1.
- 31 Jan 2018
Fitting, cracked
RT WING HAS CRACKED UPPER AFT RIB CLIP. REPAIRED RIB IAW SRM 57-06B FIG 12.
- 31 Jan 2018
Fitting, cracked
RT WING HAS CRACKED UPPER AFT RIB CLIP. REPAIRED RIB IAW SRM 57-06B FIG 12.
- 30 Jan 2018
Angle, cracked
CANTED FRAME BS 1643 LOWER LOUVER ANGLE CRACKED. REPLACED LOWER FWD LOUVER ANGLE IAW SRM 25-2018-025.
- 30 Jan 2018
Fitting, cracked
CANTED FRAME 1463 RT LOUVER BOX UPPER FWD SUPPORT WEB CLIP CRACKED. REMOVED CRACKED CLIP ON CANTED FRAME1463 RT LOUVER BOX UPPERFWD SUPPORT WEB, REPLACED CLIP…
- 30 Jan 2018
Angle, cracked
CANTED FRAME BS 1643 LEFT UPPER LOUVER BOX SUPPORT ANGLE CRACKED. REPLACED THE ANGLE IAW SRM 51-30-2, FIG 19-20.
- 30 Jan 2018
Angle, cracked
MOUNT ANGLE ON LEFT UPPER LOUVER BOX IS CRACKED. REPLACED ANGLE IAW SRM 51-30-2, FIG 19-20.
- 28 Jan 2018
Fitting, cracked
LT MLG DOOR INTERNAL ANGLE HAS SUSPECTED CRACK. (AS VIEWED THROUGH THE SECOND FROM FWD LOWER ACCESS PANEL). REMOVED CRACKED -307 ANGLE. FABRICATED AND…
- 28 Jan 2018
Fitting, cracked
RT WING STA XFS 330 (APPROX) HAS CRACKED UPPER AFT RIB CLIP. REPAIRED RT WING STA 330 XSF (APPROX) UPPER AFT RIB CLIP IAW SRM 57-06B FIG 18.
- 28 Jan 2018
Bracket, cracked
RT WING STA XRS 154 (APPROX) HAS CRACKED BRACKET. REPAIRED RT LEADING EDGE XRS 154 IAW SRM 57-06B.
- 27 Jan 2018
Cover, cracked
LT HORIZONTAL STAB AFT SPAR ACCESS PANEL 3305 COVER IS CRACKED. (REPLACED 3305 COVER PER BDR 9918401ITEM 65).
- 27 Jan 2018
Cover, cracked
LEFT HAND HORIZONTAL STAB PANEL 3303 COVER CRACKED. (REPLACED 3303 COVER PER BDR9918401 ITEM 97).
- 26 Jan 2018
Mount Bracket, broken
WHILE INSTALLING RIGHT HAND HEAT EXCHANGER FOUND PNEUMATIC DUCT SUPPORT ROD MOUNT BRACKET BROKEN IN HALF. ( REPLACED DUCT SUPPORT ROD MOUNT BRACKET IAW SRM…
- 25 Jan 2018
Attach Angle, broken
SIDEWALL SUPPORT ATTACH ANGLE BROKEN. REMOVED AND REPLACED THE ATTACH ANGLE IAW SRM 51-30-2, PARA 7, STEP 3, AND 51-30-5, PARA 7.
- 25 Jan 2018
Attach Angle, cracked
MID CARGO LT CENTER SUPPORT ATTACH ANGLE CRACKED. REMOVED AND REPLACED THE ATTACH ANGLE IAW SRM 51-30-2, FIG 3.
- 25 Jan 2018
Attach Angle, cracked
MID CARGO BAY CENTER SUPPORT ATTACH ANGLE CRACKED. REMOVED AND REPLACED THE ATTACH ANGLE IAW SRM 51-30-2, PARA 7, STEP 3, 51-30-2, FIG 3, AND 51-30-5, PARA 7.
- 23 Jan 2018
Web, cracked
VENTRAL STAIRWAY LOWER FOLDING STEP RT VERTICAL WEB CRACKED. EDGE BLENDED THE CRACK IAW SRM 51-02, FIG 1, AND 51-10-3.
- 23 Jan 2018
Web, cracked
VENTRAL STAIRWAY LOWER FOLDING STEP LT VERTICAL WEB CRACKED. EDGE BLENDED THE CRACK IAW SRM 51-02, FIG 1, AND 51-10-3.
- 13 Dec 2017
Ballast, odor
FA REPORTED BURNING ODOR NEAR THE OVERWING AREA OF THE CABIN/ R&R LOWER SIDEWALL LIGHT BALLAST AND BULB"
- 1 Dec 2017
Line, unsecure
BURNING SMELL IN CABIN/RESECURED AUG VALVE SENSELINE AND R&R LH FLOW CONTROL VALVE"
- 22 May 2017
Pseu, malfunctioned
DURING FLAPS 28 SELECTION, GEAR WARNING SOUNDED AND COULD NOT BE SILENCED. EMERGENCY DECLARED, R & R THE CAWS AND PSEU.
- 29 Sep 2016
Schrader Valve, leaking
EMERGENCY DECLARED, NOSE GEAR UNSAFE LIGHT WHEN RETRACTING THE GEAR. FOUND NOSE GEAR STRUT SCHRADER VALVE LEAKING. REMOVED AND REPLACED SCHRADER VALVE PER AMM…
- 6 Jun 2016
Coalescer Bag, odor
ON CLIMBOUT REAR F/A CALLED COCKPIT STATING SHE SMELLED ELECTRICAL ODOR, ELECTRICAL BURNING ODOR POSSIBLY. 2ND REAR F/A CONFIRMED SAME. RETURN TO DEPARTURE.…
- 12 May 2016
Skin, cracked
EXTERNAL POWER RECEPTICAL DOOR CUTOUT SKIN CRACKED .5" IN LENGTH. REPAIRED IAW STS EA 30-2016-141, DOCUMENTED ON WO 00298720, M301, 004.
- 3 Mar 2016
Indicator, faulty
DURING CLIMB OUT THE CREW RECEIVED AN AFT CARGO DOOR ANNUNCIATOR & NOTED THAT THE ACFT WAS NOT PRESSURIZING. LEVELED OFF AT 10000 FT. THE CREW EXECUTED QRH…
- 27 Oct 2015
Oxygen Mask, faulty
FIRST OFFICERS OXY MASK DIFFICULT TO INHALE & EXHALE OUT OF, AFTER APPROX 2 SEC OF EXHALE OUTFLOW VLV CLOSES. R & R FIRST OFFICERS O2 MASK ASSEMBLY IAW AMM…
- 11 Jul 2015
Light, inoperative
FOUND ON WAKE UP, EMER LIGHT AT 34 LT SIDE INOPERATIVE. RELAMPED LIGHT 34 LT SIDE. OPERATIONS CHECKED GOOD IAW AMM 33-51-01.
- 13 Apr 2015
Light, inoperative
EMERGENCY LIGHTS AT R1 DOOR CEILING INOPERATIVE. R & R LIGHT BULB IAW MM 33-53-00. OPERATIONS CHECKED GOOD.
- 2 Apr 2015
Power Supply, inoperative
FOUND ON WAKE UP, EMER LIGHTS AT ROWS 15 - 18 VERY DIM. REPLACED POWER SUPPLY. BATTERIES CHECKED GOOD AT 1.3 PLUS VOLTS. OPERATIONS CHECKED GOOD IAW AMM…
- 2 Apr 2015
Power Supply, inoperative
FOUND ON WAKE UP, EMER LIGHTS ROWS 21 - 24 INOPERATIVE. REPLACED POWER SUPPLY. BATTERIES CHECKED GOOD AT 1.3 PLUS VOLTS. OPERATIONS CHECKED GOOD IAW AMM…
- 2 Apr 2015
Light, inoperative
FOUND ON WAKE UP, AFT FLIGHT ATTENDANT STATION, EMER LIGHT ABOVE ENTRY DOOR INOPERATIVE. RELAMPED AFT FLIGHT ATTENDANT EMER LIGHT. OPERATIONS CHECKED GOOD IAW…
- 29 Mar 2015
Power Supply, inoperative
EMERGENCY LIGHTS INOPERATIVE ROWS 22 - 25. R & R POWER SUPPLY IAW AMM 33-53-00. OPERATIONS CHECKED NORMAL.
- 28 Mar 2015
Unknown, malfunctioned
ABRUPT CABIN PRESS SPIKE & PRESS DROP AFTER LANDING. PRESSURIZED & DEPRESSURIZED ACFT, NO DISCREPANCIES NOTED. ACCOMPLISHED CABIN PRESS CONTROLLER BITE TEST,…
- 11 Feb 2015
Light, inoperative
FORWARD CABIN EMER LIGHTS INOPERATIVE. INSTALLED CORRECT LAMPS. OPERATIONS CHECKED GOOD IAW AMM 33-53-00. REPLACED POWER SUPPLY IAW AMM 33-53-00 & OPERATIONS…
- 28 Jan 2015
Skin, deformed
FORWARD ENTRY DOOR L1 OUTER SKIN DEFORMED ALONG THE LOWER EDGE. REPAIRED L1 DOOR IAW SRM 52-05 FIG 64.
- 24 Jan 2015
Beam, corroded
MID CARGO DOOR CUT OUT SURROUND LOWER BEAM CORRODED. REMOVED CORROSION, FABRICATED & INSTALLED REPAIR PARTS IAW SRM 53-05 PARA 140. WORK ACCOMPLISHED ON WO…
- 24 Jan 2015
Support Angle, cracked
RIGHT FWD OTBD LOWER SUPPORT ANGLE CRACKED AT STATION 946 RBL 8. FABRICATED & INSTALLED REPAIR PARTS IAW SRM 53-01 FIG 2 SHEET 4. WORK ACCOMPLISHED ON WO…
- 20 Jan 2015
Fitting, cracked
FLOOR SUPPORT FITTING CRACKED AT STATION 826 & RBL 24. R & R FITTING IAW SRM 51-10-4 & 51-30-5. WORK ACCOMPLISHED ON WO 1011498-2000-0058 M301 ITEM 391.
- 12 Oct 2014
Battery, discharged
EMERGENCY OVERWING EXIT SIGN INOPERATIVE AT ROW 25AC & 25DEF. R & R BATTERIES IN EMER LIGHTS BATTERY PACK B5-105. OPERATIONS CHECKED GOOD IAW AMM 33-53-00.
- 12 Oct 2014
Battery, discharged
EMERGENCY LIGHTS INOPERATIVE BETWEEN ROWS 22 - 25. R & R BATTERIES IN EMER LIGHTS BATTERY PACK B5-104. OPERATIONS CHECKED GOOD IAW AMM 33-53-00.
- 8 Sep 2014
Circuit Breaker, tripped
DIGITAL FLIGHT GUIDANCE SYS FAILED IN FLIGHT. CB C17, DIGITAL GUIDANCE SYS SWITCH A, TRIPPED. COMPLIED WITH QRH PROCEDURE, CB TRIPPED ADDITIONAL INFO TO BE…
- 15 Aug 2014
Ground Wire, unsecure
EMER EXIT LIGHT INOPERATIVE ROWS 16 - 20. SECURED GND WIRE L1227B16N TO GND POINT 5202. OVERHEAD EMER LIGHTS CHECKED GOOD AT THIS TIME IAW AMM 33-53-00. POWER…
- 15 Aug 2014
First Aid Kit, missing
FORWARD FIRST AID KIT MISSING. REPLACED FIRST AID KIT IN FWD LT OVERHEAD BIN.
- 18 Jul 2014
Battery, discharged
EMER LIGHTS FROM 16 - 26 OUT. R & R BATTERY PACK BATTERIES IAW MM 33-53-00. LIGHTS OPERATION CHECKED GOOD. ACFT OK TO CONTINUE FOR SERVICE. .
- 1 Jul 2014
Power Supply, unknown
FOUND EMER LIGHT AT STATION 909 POWER SUPPLY B5-105 AFT OVERWING DOORS ON SERVICE CHECK. R & R POWER SUPPLY UNIT B5-105 EMER LIGHTS, OPERATIONS CHECKED GOOD,…
- 26 Jun 2014
Battery, discharged
EMERGENCY EXIT LIGHTS INOPERATIVE ROW 8, 16 - 19 & AFT EMER EXIT ROW. R & R BATTERIES IN APPLICABLE EMER BATTERY PACKS IAW MM 33-53-00. ALL EMER LIGHTS…
- 20 Jun 2014
Engine, malfunctioned
LOUD BANG AT 1,300', RT ENG ROLLED BACK, EGT WENT TO 800 DEGREES. R & R RT ENG IAW R0807101. OPERATIONS CHECKED NORMAL IAW TC A0707101. PART INFO WILL BE…
- 30 May 2014
Battery Pack, discharged
FORWARD & AFT EMER LIGHTS INOPERATIVE. R & R BATTERIES. OPERATIONS CHECKED NORMAL IAW AMM 33-50-00.
- 21 May 2014
Light, inoperative
AFT OVERWING EMER EXIT LIGHTS INOPERATIVE. RELAMPED, OPERATIONS CHECKED NORMAL IAW AMM 33-53-00.
- 24 Apr 2014
Battery, discharged
ROW 16 - 20 OVERHEAD EMERGENCY LIGHTS INOPERATIVE. R & R BATTERIES, LIGHTS OPERATIONS CHECKED NORMAL IAW AMM 33-53-00.
- 30 Mar 2014
Battery, discharged
DURING SERVICE CHECK, FOUND OVERWING EMERGENCY LIGHTS FWD NOT WORKING. IAW AMM 33-53-01, TROUBLESHOT PROBLEM TO BE A BATTERY PACK. FOUND BATTERIES ARE DEAD.…
- 24 Mar 2014
Battery Pack, discharged
AFT OVERWING EMERGENCY LIGHT VERY DIM. REPLACED BATTERY PACK, OPERATIONS CHECKED GOOD IAW 33-51-00.
- 26 Jan 2014
Light, inoperative
EMERGENCY EXIT LIGHTS AT ROW 14DEF - 18DEF INOPERATIVE.
- 20 Jan 2014
Battery, discharged
21-24 EMERGENCY LIGHTS INOPERATIVE. R & R EMERGENCY BATTERIES & OPERATIONS CHECKED NORMAL IAW AMM 33-55-01.
- 20 Jan 2014
Power Supply, inoperative
OVERWING EMERGENCY LIGHT INOPERATIVE. R & R POWER SUPPLY & OPERATIONS CHECKED NORMAL IAW AMM 33-53-00.
- 29 Dec 2013
Power Supply, inoperative
OVERWING EMERGENCY LIGHTS INOPERATIVE, LT & RT SIDES. REMOVED POWER SUPPLY CONTROLLER FOR EXTERNAL EMERGENCY LIGHTS. REPLACED POWER SUPPLY FOR EXTERIOR LIGHTS…
- 12 Dec 2013
Battery, discharged
BOTH LT & RT OVERWING EXIT IDENTIFIER LIGHTS WON’T SHUT OFF. R & R BATTERY POWER SUPPLY IAW MD80 AMM 33-53-00 & WDM 33-51-14, BATTERY SUPPLY B5-207,…
- 24 Nov 2013
Socket, melted
FLIGHT ATTENDANT`S & PAX REPORTED FUMES IN AFT CABIN MAINLY LT SIDE. PERFORMED QRH 26.2 PULLED RECIRC BREAKERS WITH NO HELP. SECURING RT PACK CAUSED FUMES TO…
- 8 Nov 2013
Battery Pack, inoperative
L1 & R1 EXIT LIGHTS INOPERATIVE. REPLACED EMERGENCY LIGHTS BATTERY PACK IAW AMM 33-53-00. SYS OPS NORMAL.
- 29 Sep 2013
Battery Pack, inoperative
DURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION, MX REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYS WOULD NOT TEST. MX R & R BATTERY PACK AND…
- 3 Sep 2013
Battery Pack, inoperative
DURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION, MX REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYS WOULD NOT TEST. MX R & R BATTERY PACKS AND…
- 28 Aug 2013
Battery Pack, inoperative
DURING A ROUTINE OVERNIGHT SERVICE CHECK, MX REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYS WOULD NOT TEST. MX R & R BATTERY PACK AND OPS CHECKED…
- 20 Aug 2013
Battery Pack, inoperative
DURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION, MX REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYS WOULD NOT TEST. MX R & R BATTERY PACK AND…
- 29 Jul 2013
Skin, chafed
RIGHT WING GROUND SPOILER LOWER SURFACE IS CHAFED. REPAIRED RT WING GROUND SPOILER LOWER SURFACE IAW SRM 51-90-0, PAGE 46, PARA F.
- 29 Jul 2013
Skin, chafed
LEFT WING GROUND SPOILER LOWER SURFACE IS CHAFED. REPAIRED LT WING GROUND SPOILER LOWER SURFACE IAW SRM 51-90-0, PAGE 46, PARA F.
- 20 Jul 2013
Lamp, inoperative
DURING A ROUTINE OVERNIGHT SERVICE CHECK, MX REPORTED A PORTION OF THE EMERGENCY LIGHTS WOULD NOT TEST. MX REPLACED LAMPS . OPS CHECK ACCOMPLISHED IAW AMM…
- 1 Jul 2013
Battery Pack, inoperative
EMERGENCY EVACUATION LIGHTING SYS FOUND TO BE DEFECTIVE. R & R BATTERIES IN POWER SUPPLY AND MADE ALL REQUIRED CORRECTIONS AND OPS CHECKED WAS ACCOMPLISHED…
- 5 May 2013
Battery, discharged
DURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT…
- 17 Dec 2012
Battery, discharged
DURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT…
- 28 Nov 2012
Battery, discharged
DURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT…
- 12 Nov 2012
Battery, discharged
DURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT…
- 2 Nov 2012
Battery Pack, discharged
DURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT…
- 24 Oct 2012
Battery Pack, discharged
DURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT…
- 2 Aug 2012
Battery Pack, discharged
DURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT…
- 30 Jul 2012
Battery, discharged
DURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT…
- 23 Feb 2012
Battery Pack, discharged
DURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT…
- 29 Nov 2011
Battery, discharged
DURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT…
- 26 Oct 2011
Battery, discharged
DURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT…
- 26 Oct 2011
Battery, discharged
DURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT…
- 25 Jun 2011
Battery, discharged
DURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT…
- 8 Mar 2011
Battery, discharged
DURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT…
- 19 Dec 2010
Battery, discharged
DURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT…
- 18 Oct 2010
Battery, discharged
DURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT…
- 22 Jul 2010
Skin, dented
CREASED DENT AT FS 218 LONGERON 2 LEFT. ACCOMPLISHED PERMANENT CLASS II REPAIR PER BOEING DRAWING SG0953002. LEFC AND ULTRASONIC INSP REQUIRED INITIAL 20,000;…
- 22 Jul 2010
Skin Panel, damaged
TOP OF RT HORIZONTAL I/B LEADING EDGE PANEL GOUGED AND DENTED XHR 1.152 - XHR 27.234. ACCOMPLISHED PERMENANT REPAIR PER AAR EA 14064 REV 1/R DATED 21/JUL/2010.
- 17 Nov 2009
Battery, discharged
DURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT…
- 20 Sep 2009
Battery Pack, inoperative
DURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION, MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT…
- 8 Aug 2009
Battery Pack, discharged
DURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT…
- 7 Aug 2009
Battery Pack, discharged
DURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT…
- 19 Feb 2009
Battery Pack, inoperative
DURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT…
- 8 Jan 2009
Battery Pack, inoperative
DURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT…
- 18 Dec 2008
Battery Pack, inoperative
DURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT…
- 13 Dec 2008
Battery Pack, inoperative
DURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT…
- 3 Sep 2008
Battery Pack, failed
DURING A ROUTINE OVERNIGHT SERVICE CHECK INSP, MAINT REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINT REMOVED AND REPLACED…
- 13 Aug 2008
Battery Pack, failed
DURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION, MAINT REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MAINT REMOVED AND…
- 8 Jul 2008
Battery, failed
DURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MX DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT TEST. MX…
- 7 Oct 2007
Battery Pack, inoperative
DURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION, MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT…
- 26 Sep 2007
Battery, discharged
DURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT…
- 26 Sep 2007
Battery, discharged
DURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT…
- 22 Aug 2007
Target, loose
FLIGHT 428 FROM LAS VEGAS REPORTED GEAR DOOR OPEN LIGHT ILLUMINATED WITH GEAR HANDLE UP. THE LIGHT EXTINGUISHED WITH GEAR HANDLE DOWN AND THE AIRCRAFT RETURN…
- 28 May 2007
Button, sticking
DURING CLIMB-OUT FROM LAS, LEADING EDGE SLATS WOULD NOT RETRACT. FLIGHT CREW ELECTED TO RETURN TO LAS FOR A NORMAL LANDING, NO EMERGENCY PROCEDURE WAS…
- 9 Mar 2007
Power Supply, inoperative
FLIGHT 708 DSM/SFB, THE CABIN CREW REPORT THAT THE EMERGENCY EXIT LIGHT AT THE R2 DOOR FLICKERS IN FLIGHT. SANFORD MAINTENANCE REPORT THE REMOVAL AND…
- 7 Mar 2007
Battery Pack, inoperative
FLIGHT 716 LAN/SFB - CABIN CREW REPORTED THAT THE FORWARD CABIN EXIT SIGNS FLICKERED ON AND OFF THROUGHOUT THE FLT. SANFORD MAINTENANCE REMOVED AND REPLACED…