N877AA
2018 Textron Aviation INC 172S standard FAA →
registration
- 2018
earlier registrations
2 past records
- 2006
- 1978
NTSB
- 12 Mar 1986
accident, Memphis TN
service difficulty reports
54 reports
- 16 Jun 2001
Light, inoperative
DFW - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT LIGHT AT VENTRAL STAIRS INOPERATIVE. REPLACED EMERGENCY EXIT LIGHT ASSEMBLY. SYSTEM GROUND CHECKED NORMAL…
- 10 May 2001
Beltframe, cracked
TUL - FOUND BELTFRAME DENTED AND CRACKED AT STATION 500 JUST ABOVE STRINGER 24. FABRICATED AND INSTALLED REPAIR DOUBLER ON BELT FRAME AT STATION 500 ABOVE…
- 9 May 2001
Floorbeam, corroded
TUL - FOUND FLOORBEAM HAS CORROSION ON TOP FLANGE. FIXED IT PER ESO 11697 DATED 5/9/01. (M)
- 5 May 2000
Skin, bulged
TUL - FOUND STATION 1050, STRINER 30 SKIN BULGE RIVET DISHED NOTE OIL STAIN DIVIDING AROUND BULGE AREA. REMOVED STRINGER 30 STATION 1010-1050. INSTALLED…
- 3 May 2000
Skin, bulged
TUL - FOUND FUSELAGE SKIN BULGED BETWEEN FASTENERS STATION 1176, STRINGER 27R. CUT OUT 4 INCHES WIDE BY 14 INCHES LONG SECTION OF SKIN STATION 1166 TO 1183…
- 3 May 2000
Skin, bulged
TUL - FOUND OUTBOARD SIDE OF STRINGER 28L STATION 579-590 BILGE SKIN CORRODED UNDER LEVELING COMPOUND. REMOVED DAMAGED AREA OF SKIN AND INSTALLED REPAIR…
- 1 May 2000
Skin, gouged
TUL - FOUND DEEP GOUGE/DENT DOWN AND BELOW STRINGER SKIN LAP, RIGHT SIDE OF NOSE CONE AT STATION 179. REMOVED DAMAGED SECTION. FABRICATED AND INSTALLED FILLER…
- 1 May 2000
Splice, corroded
TUL - FOUND STRINGER 27L SPLICE CORRODED STATION 675. REMOVED AND REPLACED CORRODED STRINGER SPLICE PER SRM 51-10-1. (M)
- 1 May 2000
Skin, corroded
TUL - FOUND LOWER WING SKIN AFT SIDE OF STRINGER 55C LBL 26 TO LBL 28 SKIN HAS HEAVY CORROSION. INSTALLED WING CENTER SECTION LOWER SKIN REPAIR IAW SRM…
- 1 May 2000
Stringer, corroded
TUL - FOUND STRINGER RIGHT AND STRINGER SPLICE CORRODED STATION 685-690. REMOVED CORRODED SECTION OF STRINGER AND SPLICE AND INSTALLED STRINGER SPLICE REPAIR…
- 1 May 2000
Shear Tie, corroded
TUL - FOUND FRAME SHEAR TIE FORWARD SIDE 680 FRAME BETWEEN STRINGER 27R-28R CORRODED. REMOVED CORROSION SECTION OF SHEAR TIE AND INSTALLED REPAIR PER SRM…
- 1 May 2000
Strap, cracked
TUL - LFEC SHOWS CRACK IN BEAR STRAP AT LOWER AFT CORNER OF FORWARD RIGHT GALLEY DOOR FRAME. REQUIRES REPAIR PER SERVICE BULLETIN 727-53-0188 FIG 3. REPAIRED…
- 1 May 2000
Skin, gouged
TUL - FOUND DEEP GOUGE/DENT ON AND BELOW STRINGER SKIN LAP RIGHT SIDE OF NOSE CONE AT STATION 179. REMOVED DAMAGED AREA. FABRICATED AND INSTALLED DOUBLER AND…
- 14 Dec 1999
Sign, malfunctioned
TUL - FOUND EMERGENCY EXIT LIGHT SIGN ABOVE COCKPIT DOOR IS DIM, E-583095020. INSTALLED SERVICEABLE LTG 5192 WORK ACCOMPLISHED PER MM 33-50-101-2. (M)
- 14 Dec 1999
Light, inoperative
TUL - FOUND FORWARD GALLEY LEFT DOOR FRAME EMERGENCY EXIT LIGHT MARKER DAMAGED E-58 3095015. INSTALLED SERVICEABLE P2-01-0031-302 WORK ACCOMPLISHED PER MM…
- 22 Apr 1999
Filter, restricted
MEM - FLT 1929 - DURING CRUISE, NR 1 ENGINE SURGED 4 TIMES AT FL330 ON ALL PARAMETERS ACCOMPANIED BY FLICKERING AMBER ENGINE ICE LIGHT. FLIGHT AIR INTERRUPTED…
- 13 Jan 1999
Panel, malfunctioned
ORD - FLT 814 - EN ROUTE TUL-ORD, DURNG CRUISE, AUTO CONTROLLER FAILED PRIOR TO SWITCHING MANUALLY TO STANDBY MODE. CABIN OXYGEN MASKS WERE DEPLOYED. LANDED…
- 6 Jun 1998
Skin, corroded
TUL - STATION 950F STRINGER 28R BELLY SKIN HAS CORROSION. INSTALLED SKIN REPAIR PER ESO 11697, DATED 5-11-98. (M)
- 6 Jun 1998
Stringer, corroded
TUL - OUTBOARD SIDE OF STRINGER 28R IS CORRODED STATION 950F TO 970. REPAIRED STRINGER PER ESO 11697, DATED 5-11-98. (M)
- 27 May 1998
Shear Tie, corroded
TUL - FOUND CORROSION ON AFT SIDE OF SHEAR TIE STATION 640 OUTBOARD STRINGER 27RT. REMOVED AND REPLACED SHEAR TIE. (M)
- 27 May 1998
Stringer, corroded
TUL - HEAVY CORROSION INSIDE STRINGER AT JUNCTION TO BELLFRAME STRINGER 22R STATION 1148. INSTALLED STRINGER SPLICE PER SRM 53-10-3. (M)
- 27 May 1998
Stringer, corroded
TUL - FOUND HEAVY CORROSION INSIDE STRINGER 23R AT JUNCTION TO BELLFRAME STATION 1148. INSTALLED STRINGER SPLICE PER SRM 53-10-3. (M)
- 27 May 1998
Skin, corroded
TUL - SKIN BULGED AND RIVETS BROKEN, CORRODED. DOUBLER INSTALLED PER SRM 53-30-3 FIG 1. (M)
- 26 May 1998
Frame, corroded
TUL - STATION 351 BETWEEN STRINGER 28 LT AND 28 RT CORROSION ON BELTFRAME. INSTALLED NEW BELTFRAME STATION 351 PER SRM 51-10-1 AT STRINGER 26L TO 26R. (M)
- 26 May 1998
Floor Pan, corroded
TUL - FOUND CORROSION ON LAV FLOOR STATION 1159 TO STATION 1174 RBL 25 THROUGH RBL 45 9 PLACES. REMOVED CORROSION, REPAIRED PER SRM 51-40-2. (M)
- 26 May 1998
Frame, corroded
TUL - FOUND CORROSION ON FORWARD SIDE OF BELLFRAME STATION 720D BETWEEN STRINGER 28 LT AND 28 RT. FRAME REPAIRED PER SRM 53-10-4 FIG 12. (M)
- 26 May 1998
Skin, corroded
TUL - FORWARD CARGO BELLY SKIN CORRODED STATION 505-515, INBOARD SIDE STRINGER 26L. REMOVED CORROSION AND INSTALLED SKIN REPAIR PER SRM 53-30-3 FIG 24. (M)
- 26 May 1998
Fitting, corroded
TUL - RT CORROSION EMITTING FROM NLG RT TRUNNION BEARING BORE. LEFT CORROSION IN BORE LT TRUNNION BEARING BORE. REPLACED RT TRUNNION FITTING. REPLACED LEFT…
- 26 May 1998
Beam, corroded
TUL - FOUND CORROSION ON UPPER SURFACE OF RT HORIZ STAB TE BEAM FORWARD OF 4TH FROM OUTBOARD ELEV HINGE. COMPLETED REPAIR BY INSTALLING DOUBLER AS PER ESO…
- 26 May 1998
Spar, corroded
TUL - WING FRONT SPAR LOWR CAP CORRODED AT NR 5 SLAT INBOARD TRACK TOP SIDE WS 373. INSTALLED REPAIR PER ESO 11697 DATED 5/11/98. (M)
- 26 May 1998
Floorbeam, corroded
TUL - FOUND CORROSION TOP OF FLOORBEAM. INSTALLED DOUBLER AT FLOORBEAM STATION 400 RBL 12 PER SRM 53-10-8 9C-9E. ALSO, INSTALLED FLOOR SUPPORT AND BRACKET…
- 26 May 1998
Floorbeam, corroded
TUL - FOUND CORROSION ON BOTH SIDES OF UPPER FLANGE OF FLOORBEAM STATION 345 RBL 44-64. BLENDED OUT CORROSION REPAIRED AND INSTALLED DOUBLER PER SRM 53-10-8…
- 26 May 1998
Stringer, cracked
TUL - FOUND STRINGER 15L CRACKED AT FORWARD AND AFT END OF ICE LIGHT CUTOUT. REPAIRED PER SRM 53-10-3 FIG 5. (M)
- 26 May 1998
Stringer, cracked
TUL - STRINGER 15R CRACKED AT FORWARD AND AFT END OF ICE LIGHT CUTOUT. REPAIRED PER SRM 53-10-3 FIG 5. (M)
- 26 May 1998
Stringer, corroded
TUL - FOUND CORROSION IN STRINGER 27 RT STATION 620-628. REMOVED CORROSION AND INSTALLED CHANNEL REPAIR PER ESO 11697, DATED 5-8-98. (M)
- 26 May 1998
Stringer, corroded
TUL - FOUND STRINGER CORRODED OUTBOARD SECTION. FASTENED STRINGER CLIP TO FRAME AND STRINGER. COMPLETED CRACKED STRINGER TYPICAL REPAIR PER SRM 53-10-3 PAGE…
- 26 May 1998
Stringer, corroded
TUL - OUTBOARD SIDE OF STRINGER 28R CORRODED STATION 1100. INSTALLED STRINGER SPLICE REPAIR PER SRM 53-10-3. (M)
- 26 May 1998
Stringer, corroded
TUL - STRINGER HEAVILY CORRODED INBOARD/OUTBOARD SECTION STATION 1040 STRINGER 26R. REPAIRED STRINGER PER SRM 53-10-3. (M)
- 26 May 1998
Floorbeam, corroded
TUL - FOUND CORROSION ON UPPER AND LOWER SURFACE OF TOP FLANGE OF FLOORBEAM STATION 380 RBL 24 TO RBL 64. FABRICATED AND INSTALLED REPAIR PER SRM 53-10-8. (M)
- 26 May 1998
Floorbeam, corroded
TUL - CORROSION ON FLOORBEAM UPPER CAP STATION 1110 LBL 10 TO LBL 12. INSTALLED DOUBLER PER SRM 53-10-8. (M)
- 26 May 1998
Skin, corroded
TUL - LEVELING COMPOUND BULGING STATION 502-518 INBOARD STRINGER 26 RT. CUT OUT DAMAGED AREA, INSTALLED REPAIR PARTS AS PER SRM 53-30-3 FIG 24 DETAIL 1. (M)
- 26 May 1998
Skin, corroded
TUL - FOUND CORROSION ON SKIN STATION 703 OUTBOARD STRINGER 27 RT BY DOME NUT. INSTALLED DOUBLER PER SRM 53-30-3 FIG 3. (M)
- 26 May 1998
Skin, corroded
TUL - FOUND SKIN CORROSION STATION 1033 STRINGER 28R. INSTALLED DOUBLER PER SRM 53-30-3. (M)
- 26 May 1998
Stiffener, corroded
TUL - LEFT FORWARD AND AFT VERTICAL STIFFENERS CRACKED AT LT NLG TRUNNION. REPLCED LT FORWARD VERTICAL STIFFENER. (M)
- 15 May 1998
Floorbeam, corroded
TUL - FOUND CORROSION ON BOTH SIDES OF TOP FLANGE OF FLOORBEAM STATION 344 LBL 38 TO 39. CUT OUT CORRODED FLANGE AND INSTALLED NEW FLANGE AND DOUBLERS PER SRM…
- 10 Feb 1998
Light, defective
DFW - DURING OVERNIGHT MAINTENANCE, RIGHT HAND FORWARD SERVICE DOOR EMERGENCY LIGHT FAILED TO ILLUMINATE. REPLACED RIGHT HAND FORWARD SERVICE DOOR EMERGENCY…
- 18 Aug 1997
Connector, failed
DFW - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT FLOOR PATH LIGHTING IN AFT SECTION OF FIRST CLASS CABIN DIM. REPAIRED EMERGENCY FLOOR LIGHT STRIP CONNECTOR…
- 21 Apr 1997
Casting, corroded
TUL - CORROSION ON LOWER SURFACE, LOWER FLANGE ON RIGHT WING INBOARD AILERON QUADRANT CASTING. REPAIRED PER ESO 11697 PER ACFT N877AA DATED 4-8-97. 51,950…
- 21 Apr 1997
Skin, cracked
TUL - FORWARD ENTRY DOOR LOWER HINGE CUT-OUT IS CRACKED. REPAIRED PER SB 727-53-0198, FIGURE 4 DETAIL IV. 51,950 HOURS. CYCLES, 32,018. (X)
- 19 Mar 1997
Stringer, corroded
TUL - FOUND CORROSION ON STRINGER 28L, BS 450 AFT OF E/E DOOR. REMOVED SECTION OF STRINGER AND INSTALLED NEW SECTION FROM BS 450-480. (M)
- 18 Mar 1997
Stringer, corroded
TUL - FOUND STATION 560 STRINGER 27 RIGHT HAS CORROSION INSIDE. REMOVED CORROSION, INSTALLED CHANNEL REPAIR PER SRM 53-10-3 AND ESO 11697. (M)
- 18 Mar 1997
Stringer, corroded
TUL - FOUND CORROSION INSIDE OF STRINGER 28R, STATION 558-562. REPAIRED STRINGER PER SRM 51-10-3. (M)
- 18 Mar 1997
Bell Frame, dented
TUL - DENT IN BELL FRAME AT STATION 560 LEFT SIDE OF FORWARD CARGO COMPARTMENT. REPAIRED FRAME BY INSTALLING A DOUBLER PER SRM 53-10-4. (M)
- 11 Jul 1996
Light, loose
MIA - DURING OVERNIGHT MAINTENANCE, FOUND THE FIRST CLASS EMERGENCY EXIT FLOOR PATH LIGHTS INOPERATIVE. SECURED FIRST CLASS EMERGENCY EXIT FLOOR PATH LIGHT…