N876GA
1995 McDonnell Douglas DC-9-83(MD-83) standard FAA →
reservations
earlier registrations
1 past record
- 1995
service difficulty reports
63 reports
- 30 Apr 2018
Control Panel, malfunctioned
MID CARGO FIRE ALARM AT FL320. EMERGENCY DECLARED. R & R ALL THREE CARGO SMOKE DETECTORS AND CARGO FIRE CONTROL PANEL.
- 6 Oct 2017
Iru, failed
DUAL MAP FAILURE, EMERGENCY DECLARED. R & R THE NR 1 & 2 IRU.
- 1 Oct 2017
Garlock Seal, leaking
NR 1 ENG OIL QTY STEADILY DECREASED THROUGHOUT THE FLIGHT, ENGINE SHUTDOWN. R&R NR 1 ENG GARLOCK SEAL AND HOUSING FOR N2 TACH GEN.
- 6 Jul 2016
Holder, loose
REAR F/A REPORTS BURNING, PLASTIC ODOR, BURNING POPCORN ODOR. PULLED C/B, ALL F/A REPORTED ODOR MOVING FORWARD FROM REAR CABIN PROGRESSIVELY GETTING HEAVIER.…
- 14 Dec 2015
Battery, discharged
AFT OVERWING EMER EXIT ON BOTH RT & LT EXITS ARE INOPERATIVE. REPLACED BATTERIES IAW MM 33-50-00. OPERATIONS CHECKED GOOD.
- 6 Nov 2015
Flashlight, inoperative
FLIGHT ATTENDANT REPORTS FWD FLASHLIGHT INOPERATIVE. REPLACED FLASHLIGHT ASSEMBLY IAW 25-60-00. OPERATIONS CHECKED GOOD.
- 15 Oct 2015
Power Supply, inoperative
FOUND ON WAKE UP, TAIL CONE & AFT FLIGHT ATTENDANT EMER LIGHTS INOPERATIVE. CHECKED BATTERIES, CHECKED GOOD. RELAMPED TAIL CONE BULBS, NO HELP. REPLACED FWD…
- 5 Sep 2015
Tab, delaminated
LEFT ELEVATOR CONTROL TAB INBD END, PREVIOUS REPAIR DELAMINATED AT STATION XE 14.525. REMOVED DAMAGED AREA, FABRICATED REPAIR PARTS, ACCOMPLISHED HOT BOND…
- 26 Aug 2015
Floor Support, corroded
FLOOR SUPPORT CORRODED, FS 200, LBL44. FABRICATED REPLACEMENT SUPPORT IAW SRM 51-10-4 M301 NR 588. R & R SUPPORT IAW SRM 51-30-2 M301 NR 587.
- 19 Aug 2015
Seat Track, corroded
SEAT TRACK CORRODED FROM FS 200 - FS 241, RBL 22. R & R SEAT TRACK FS 200 - 241, RBL22 IAW SRM 53-05 FIG 4F.
- 17 Jul 2015
Power Supply, inoperative
EMERGENCY LIGHTS INOPERATIVE AT AFT NONSTANDARD DROP CEILING PANEL. R & R BATTERY POWER SUPPLY. OPERATIONS CHECKED GOOD IAW AMM 33-53-04.
- 1 Jul 2015
Light, inoperative
L1 DOOR EMER LIGHT INOPERATIVE. R & R L1 DOOR EMER EXIT LIGHT. CABIN OPERATIONS CHECKED GOOD IAW AMM 33-53-00-4-0.
- 19 Jun 2015
Structure, dented
LEFT ENG PYLON TE DENTED 13"" FROM INBD EDGE, MEASURES 3.6"" X 2.1"" X 0.081"". OUT OF LIMITS IAW SRM 51-50-2 PAGE 4 FIGURE 1 SHEET 1. INSPECTION LT ENG PYLON…
- 12 Jun 2015
Csd, low
AFTER ENG RUNS & MX SIGNOFF, THE FLIGHT DEPARTED, ABOUT 10 MINUTES INTO THE FLIGHT THE CREW NOTED THAT THE LT CSD, WHICH WAS THE ONE THAT HAD BEEN REPLACED…
- 25 May 2015
Unknown, odor
FLIGHT ATTENDANTS & PAX COMPLAINING OF STRONG FUEL SMELL DURING TAXI OUT. RETURNED TO GATE. ACCOMPLISHED TC 21-059-002 CABIN ODOR & SMOKE. TROUBLESHOOTING…
- 30 Apr 2015
Battery, discharged
EMERGENCY LIGHTS AT BACK OF OVERHEAD PANEL IN COCKPIT WILL NOT TEST. REPLACED EMER LIGHT BATTERIES FOR COCKPIT OVERHEAD. OPERATIONS CHECKED GOOD IAW AMM…
- 18 Apr 2015
Shutoff Valve, faulty
FLIGHT ATTENDANTS REPORTED A BURNING RUBBER SMELL AFTER TAKEOFF. TROUBLESHOOTING PERFORMED ON WO 252674. LT PRESS REGULATING & SOV IDENTIFIED AS FAULTY. R & R…
- 20 Mar 2015
Hydraulic Line, cracked
DURING DESCENT, NOTICED LT HYD PRESS READ 6 AT LAS QTY. AT LAS IT READ 12, PERFORMED QRH, HYD LEAK SUSPECTED. AFTER LANDING FLUID PRESS & QTY BOTH WENT TO…
- 17 Jan 2015
Light, inoperative
ROW 10 EMER LAMP INOPERATIVE. RELAMPED EMER LAMP IAW AMM 33-53-00. OPERATIONS CHECKED GOOD.
- 30 Nov 2014
Rudder Pedal, jammed
RUDDER PEDALS JAMMED ON LANDING ROLL. INSPECTED RUDDER TRAVEL LIMITER, RUDDER PITOT HEAT & RUDDER ACTUATOR FOR OPERATION & BINDING. NO DISCREPANCIES FOUND.…
- 30 Aug 2014
Light, inoperative
EMERGENCY LIGHT AT ROW 22 OVERHEAD INOPERATIVE, RELAMPED. OPERATIONS CHECKED GOOD IAW AMM 33-53-00.
- 23 Jul 2014
Warning System, false activation
TAIL COMPARTMENT TEMP HIGH LIGHT. RAN QRH 21.4, LIGHT EXTINGUISHED AT 2 MINUTES. COMPLIED WITH WORK ORDER 230201 ITEM 1. PERFORM TASK CARD I0592101 TAIL…
- 22 Feb 2014
Doubler, chafed
LEFT OTBD FLAP, INBD VANE LE DOUBLER IS CHAFED. REMOVED DAMAGED DOUBLER & INSTALLED PERMANENT REPAIR IAW SRM 51-70-2 PARA 18B PG 91-95.
- 17 Feb 2014
Scuff Plate, cracked
MID PIT RT AFT SCUFF PLATE IS CRACKED. FABRICATED NEW MID PIT RT AFT SCUFF PLATE IAW SRM 51-10-4.
- 17 Jul 2013
Lamp, inoperative
DURING A ROUTINE OVERNIGHT SERVICE CHECK, MX REPORTED A PORTION OF THE EMERGENCY LIGHT SYS WOULD NOT TEST. REPLACED LAMPS. OPS CHECK SATISFACTORY IAW AMM…
- 4 May 2013
Battery, discharged
DURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT…
- 19 Mar 2013
Battery Pack, discharged
DURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT…
- 4 Mar 2013
Battery Pack, discharged
DURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT…
- 4 Mar 2013
Battery Pack, discharged
DURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT…
- 4 Mar 2013
Battery Pack, discharged
DURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT…
- 8 Nov 2012
Battery Pack, discharged
DURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT…
- 5 Sep 2012
Battery Pack, discharged
DURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT…
- 18 Aug 2012
Battery Pack, discharged
DURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT…
- 7 Aug 2012
Battery, discharged
DURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT…
- 28 Jul 2012
Battery Pack, discharged
DURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT…
- 28 Jul 2012
Battery, discharged
DURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT…
- 24 May 2012
Battery, discharged
DURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT…
- 18 May 2012
Light, inoperative
DURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT…
- 18 May 2012
Battery, discharged
DURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT…
- 16 May 2012
Battery, discharged
DURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT…
- 14 May 2012
Battery, discharged
REPORTED BY THE FLIGHT CREW THE EMERGENCY EVACUATION LIGHTING SYSTEM HAS BEEN FOUND TO BE DEFECTIVE. MAINTENANCE PERSONNEL REMOVED AND REPLACED THE…
- 24 Feb 2012
Light, inoperative
DURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT…
- 23 Jan 2012
Battery Pack, discharged
DURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT…
- 2 Jan 2012
Battery, discharged
DURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT…
- 2 Jan 2012
Battery, discharged
DURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT…
- 26 Dec 2011
Battery, discharged
DURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT…
- 22 Dec 2011
Battery, discharged
DURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT…
- 22 Dec 2011
Battery, discharged
DURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT…
- 19 May 2011
Battery, discharged
DURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT…
- 27 Mar 2011
Wire, broken
FLIGHT CREW REPORTED LEFT ENGINE OIL TEMP FLUCTUATED BETWEEN APPROX. 120-152 C'. ADVANCING THE THROTTLE REDUCED TEMPERATURE PER QRH. TEMP WENT UNCONTROLLED TO…
- 26 Feb 2011
Battery Pack, discharged
DURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT…
- 25 Jan 2011
Seat Track, corroded
MAIN CABIN SEAT TRACK HAS CORROSION AND CHAFE MARKS FROM STA 770 TO 800. REPLACED SEAT TRACK ASSEMBLY AT THE MAIN CABIN RT I/B STA 741 TO 800 AS PER MD80 SRM…
- 3 Dec 2010
Battery Pack, discharged
DURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT…
- 26 Oct 2010
Battery, discharged
DURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT…
- 4 Oct 2010
Battery Pack, inoperative
DURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT…
- 4 Oct 2010
Battery, discharged
DURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT…
- 2 Oct 2010
Battery, discharged
DURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT…
- 19 Dec 2009
Battery Pack, inoperative
DURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT…
- 3 Sep 2009
Cusp Web, corroded
C-CHECK PULSE LINE TULE: CORROSION ON CUSP STA 872 RT INBOARD, ADDRESSED AS REQUIRED.
- 17 May 2007
Battery Pack, inoperative
DURING A ROUTINE OVERNIGHT SERVICE CHECK INSPECTION, MAINTENANCE DEPARTMENT PERSONNEL REPORTED A PORTION OF THE EMERGENCY EVACUATION LIGHTING SYSTEM WOULD NOT…
- 11 Apr 2007
Battery Pack, inoperative
DURING A ROUTINE OVERNIGHT SERVICE CHECK, MAINTENANCE INSPECTION, MAINTENANCE REPORTED THAT THE CEILING EMERGENCY LIGHTS BETWEEN FUSELAGE STATIONS 1133 AND…
- 18 Jan 2006
Wire, disconnected
LAS - MAINTENANCE FOUND THE L1 DOOR EXIT SIGN INOPERATIVE. FOUND L1 DOOR EMERGENCY EXIT SIGN NOT WIRED. CONNECTED WIRING TO L1 DOOR EMERGENCY EXIT SIGN IAW…
- 3 Jan 2006
Flashlight, inoperative
MAINTENANCE FOUND THE FORWARD GALLEY EMERGENCY FLASHLIGHT INOPERATIVE. REPLACED THE FORWARD GALLEY EMERGENCY FLASHLIGHT AND OPERATIONALLY CHECKED GOOD IAW MM…