- 25 Apr 2002
Bolt, sheared
BOLT ASSEMBLY - SIDE SPINDLE WAS FOUND WITH HEAD OF BOLT ASSEMBLY SHEARED OFF AND THE WAS BACKING OUT AFTER TOWING THE AIRCRAFT FROM STORAGE TO THE…
- 19 Sep 2001
Frame, corroded
TUL - FOUND CORROSION ON FRAME STATION 370 BELOW FLOOR LINE RBL 65. CUT OUT DAMAGED AREA AND INSTALLED DOUBLER PER ESO 11697 ATED 9-14-2001. (M)
- 18 Sep 2001
Floorbeam, corroded
TUL - FOUND SATION 1130 TOP OF FLOORBEAM BETWEEN LEFT SEAT TRACKS CORRODED. FABRICATED AND INSTALLED REPAIR STRAP PER ESO 11697 DATED 9-17-01. (M)
- 12 Sep 2001
Splice, corroded
TUL - FOUND LIGHT CORROSION ON END OF STRINGER SPLICE, STATION 686, STRINGER 28R. REMOVED AND REPLACED WITH NEW STRINGER SPLICE PER SRM 51-10-1. (M)
- 13 Dec 2000
Skin, corroded
TUL - FOUND LOWER WING SKIN CORRODED 18 INCHES BY 3 INCHES, INBOARD OF THE LEFT PLENUM INBOARD ANGLE STATION 830 TO 810. REPAIRED LEFT PLENUM CORROSION (WING…
- 13 Dec 2000
Skin, corroded
TUL - FOUND LOWER WING SKIN CORRODED 12 INCHES BY 3 INCHES, INBOARD OF RIGHT PLENUM INBOARD ANGLE MULTIPLE AREAS. REPAIRED RIGHT PLENUM CORROSION (WING SKIN)…
- 13 Dec 2000
Skin, corroded
TUL - FOUND LOWER WING SKIN LEFT PLENUM HAS SEVERE CORROSION 6 INCHES BY 4 INCHES, IN PREVIOUSLY WORKED AREA LBL 32.2 STRINGER 55 AND 53. REPAIRED LEFT PLENUM…
- 6 Dec 2000
Fitting, corroded
TUL - FOUND RBL 28 BULKHEAD ATTACH FITTING HAS HEAVY CORROSION 1 INCH BY .250 INCH, AT STATION 1178-1183 UNDER CABIN FLOOR. INSTALLED NEW FITTING AT RBL 28…
- 5 Dec 2000
Stiffener, corroded
TUL - FOUND VERTICAL STIFFENER CORRODED AT AROUND WIRE TERMINAL. FABRICATED AND INSTALLED DOUBLER PER SRM 57-10-4. (M)
- 10 Oct 2000
Light, inoperative
DFW - DURING OVERNIGHT MAINTENANCE, FORWARD CABIN EMERGENCY EXIT FLOOR PATH LIGHTS INOPERATIVE. REPLACED FORWARD CABIN EMERGENCY EXIT FLOOR PATH LIGHT…
- 8 Aug 2000
Light, inoperative
DFW DURING OVERNIGHT MAINTENANCE L2 OVERHEAD EMERGENCY LIGHT INOPERATIVE. REPLACED LIGHT ASSEMBLY. SYSTEM GROUND CHECK NORMAL OPERATION.
- 22 Jun 2000
Skin, corroded
TUL - FOUND CORROSION ON WING CENTER SECTION LOWER SKIN AFT OF STRINGER 5 BETWEEN RBL 18.55 AND RBL 30.77 AND FORWARD OF STRINGER 5 BETWEEN RBL 18.55 AND RBL…
- 27 Apr 2000
Light, broken
MIA - DURING OVERNIGHT MAINTENANCE, EMERGENCY LIGHT ON FORWARD GALLEY DOOR INOPERATIVE. REPLACED EMERGENCY LIGHT ON FORWARD GALLEY DOOR. SYSTEM GROUND CHECK…
- 12 Apr 2000
Light, inoperative
DFW - FOUND DURING OVERNIGHT MAINTENANCE, AIRSTAIRS EMERGENCY EXIT LIGHT INOPERATIVE. REPLACED AIRSTAIRS EMERGENCY EXIT LIGHT ASSEMBLY. SYSTEM GROUND CHECKED…
- 28 Mar 2000
Web, cracked
TUL - APPROX .5 INCH CRACK AT LIGHTENING HOLE AT STATION 1303. STOP DRILLED CRACK AND INSTALLED REPAIR PER 51-40-2. (M)
- 28 Mar 2000
Skin, cracked
TUL - FOUND FUSELAGE FORWARD ENTRY LOWER HINGE CUT OUT, SKIN HAS .25 INCH CRACK. ROUTED OUT DAMAGE, INTALLED DOUBLER PER SERVICE BULLETIN 727-53-0198. (M)
- 28 Mar 2000
Beam, cracked
TUL - FOUND STATION 1183 BULKHEAD, LBL 8, BERTICAL BEAM HAS 1.25 INCH CRACK IN OUTBOARD FLANGE AT LOWER END OF BEAM. STOP DRILLED CRACK AND INSTALLED REPAIR…
- 28 Mar 2000
Frame, cracked
TUL - RIGHT W/W STATION 190-913.5 STUB FRAME 2.25 INCH CRACK IN FRAME AT FASTENER STATION 910. INSTALLED REPAIR PER SRM 53-10-2. (M)
- 28 Oct 1999
Light, inoperative
TUL - LEFT AND RIGHT OVERWING EXIT EMERGENCY LIGHT, SHORTED TO GROUND INOP. RESPLICED IN NEW LIGHT ASSY. (M)
- 5 Jul 1999
Wire, broken
MIA - DURING OVERNIGHT CHECK, RIGHT EMERGENCY EXIT FLOOR PATH LIGHTING INOPERATIVE. REPAIRED EMERGENCY EXIT FLOOR PATH LIGHTING WIRE AT RIGHT AFT EXIT LIGHT…
- 13 Nov 1998
Frame, cracked
TUL - FOUND 303.9 FRAME HAS SMALL CRACK EXTENDING FROM CUTOUT/RADIUS FOR STRINGER 16L INTERCOSTAL VIEWED FROM COCKPIT SIDE OF WEB. REPAIRED PER SB…
- 13 Nov 1998
Skin, corroded
FOUND CORROSION ON LOWER SKIN ABOVE RIGHT PRIMARY HEAT EXCHANGER 2 INCH BY 2 INCH. INSTALLED DOUBLER AND TRIPLER PER SRM 57-30-3 FIG 9 AFTER CORROSION…
- 20 Nov 1997
Stringer, corroded
TUL - STRINGER 27R BLOWN OUT OUTBOARD SIDE STATION 720 PLUS 10 INCHES. REMOVED DAMAGED SECTION OF STRINGER SPLICED IN NEW SECTION PER SRM 53-10-3 FIG 1. (M)
- 20 Nov 1997
Frame, dented
TUL - BELL FRAME STATION 1090 ABOVE STRINGER 26L, DENTED. CUT OUT DAMAGED AREA AND INSTALLED DOUBLER IAW SRM 53-10-4. (M)
- 20 Nov 1997
Stringer, cracked
TUL - TOP WING STRINGER CRACKED AT WS 686.50 AFT CENTER LINE. REPAIRED STRINGER PER BOEING SERVICE BULLETIN 727-57A159. (M)
- 20 Nov 1997
Skin, gouged
TUL - GOUGE IN SKIN AT STRINGER 2R, STATION 840 BLENDED BEYOND LIMITS. CUT OUT DAMAGE AND INSTALLED DOUBLER PER SRM 53-30-3. (M)
- 20 Nov 1997
Stiffener, cracked
TUL - INSPAR STIFFENER UPPER NR 10 CRACKED AT STATION 686.50 LT WING TANK. STOP DRILLED CRACK INSTALLED DOUBLER PER BOEING SB 727-57A159. (M)
- 20 Nov 1997
Angle, corroded
TUL - FOUND CORROSION ON CREASE ANGLE FROM FS 344 TO 354 RIGHT SIDE. REMOVED CORRODED SECTION AND INSTALLED NEW SECTION. (M)
- 20 Nov 1997
Floorbeam, corroded
TUL - FOUND CORROSION ON TOP OF FLOORBEAM. INSTALLED DOUBLER ON FLOORBEAM PER SRM 53-10-8. (M)
- 20 Nov 1997
Web, cracked
TUL - WEB CRACKED UNDER NR 7 SPOILER ACTUATOR CASTING, TWO PLACES. REMOVED DAMAGED SECTION OF WEB AND INSTALLED WEB REPAIR PER BOEING SERVIEC BULLETIN…
- 20 Nov 1997
Stringer, corroded
TUL - FOUND SKIN BULGE AT STRINGER 27L, STATION 1030. CUT OUT CORRODED SECTION OF STRINGER 27L AND INSTALLED DOUBLER SPLICE PER SRM 53-10-3. (M)
- 20 Nov 1997
Floorbeam, corroded
TUL - STATION 344 RBL 15 CORROSION ON TOP OF FLOORBEAM. REMOVED CORROSION, FOUND BEYOND LIMITS. REMOVED DAMAGED AREA OF FLOORBOARD INSTALLED DOUBLER PER SRM…
- 20 Nov 1997
Frame, dented
TUL - BELL FRAME DENTED STATION 580, BETWEEN STRINGER 24L AND 25L. CUT OUT DAMAGED AREA AND INSTALLED DOUBLER PER SRM 53-10-4 PAGE 3. (M)
- 20 Nov 1997
Stringer, cracked
TUL - STRINGER 5 RIGHT STATION 344 CRACKED TWO PLACES AT LAV ATTACH BRACKET. REMOVED DAMAGED SECTION OF STRINGER AND SPLICED STRINGER PER SRM 53-10-3. (M)
- 20 Nov 1997
Angle, corroded
TUL - FOUND CORROSION AROUND BOLT HOLE OF 1176 CHORD ANGLE TIED DOWN CABLE EYE BOLT RBL 48 INCHES. INSTALLED SERVICEABLE STRAP PER ESO 11697 DATED 10/21/97. (M)
- 23 Mar 1997
Light, defective
DFW - DURING OVERNIGHT CHECK, AFT STAIRS EMERGENCY LIGHT INOPERATIVE. REPLACED AFT STAIRS EMERGENCY LIGHT. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)
- 10 Jan 1997
Stringer, corroded
TUL - FOUND STRINGER 22L AND END FITTING CORRODED FROM STATION 1178 TO 1183. REPLACED STRINGER 22L AFT END FITTING AT STATION 1183 AND SPLICED STRINGER PER…