N8765Q
2022 Boeing 737-8 standard FAA →
registration
- 2022
earlier registrations
1 past record
- 1976
service difficulty reports
14 reports
- 13 Nov 2026
Flashlight, inoperative
COCKPIT EMERGENCY FLASHLIGHT WILL NOT TEST/INOP FAULT OPENED VIA AVIOBOOK POSITIONED FLASHLIGHT CORRECTLY IN THE MOUNTING BRACKET PERFORMED FLASHLIGHT…
- 15 Oct 2026
Hook, loose
L1 ESCAPE SLIDE GIRT BAR HOOKS WERE LOOSE. REPLACED THE FASTENER ON GIRT BAR HOOK IAW SRM 51-40-02, AND AMM 25-66-01.
- 7 Oct 2026
Girt Bar, loose
R1 DOOR GIRT BAR HAS EXCESSIVE SLACK ON SLIDE HOUSING. REINSTALLED LOOSE R1 SLIDE GIRT BAR MATERIAL BACK INTO EMERGENCY SLIDE HOUSING IAW AMM 25-66-00. AC OK…
- 5 Sep 2026
Battery, inoperative
F/O SIDE AFT F/A OTBD FLASHLIGHT INOPERATIVE. R & R FLASHLIGHT BATTERY IAW S.I.P.
- 2 Sep 2026
Seat, out of adjust
RACEWAY IN FRONT OF SEAT ROW LH 9ABC AND 16ABC NEED ADJUSTMENT PER DWG DG381-142007A. ADJUSTED RACEWAY IN FRONT OF SEAT ROW LT 9ABC AND 16ABC PER DWG…
- 1 Sep 2026
Battery Pack, inoperative
EMERGENCY LIGHTS INOPERATIVE, REMOVED AND REPLACED THE BATTERY PACK IAW AMM 33-51-06-960-802.
- 22 Aug 2026
Floor Panel, delaminated
MID CABIN CENTER FLOOR PANEL HAS SURFACE DELAMINATION. REMOVED AND REPLACED THE FLOOR PANEL 231KF IAW AMM 53-21-00-000-801 AND AMM 53-21-00-400-801.
- 21 Aug 2026
Handle, unsecure
L1 DOOR ASSIST HANDLE NEEDS SECURED. SECURED THE L1 DOOR ASSIST HANDLE IAW AMM 25-21-25-420-801.
- 21 Aug 2026
Handle, unsecure
R2 DOOR ASSIST HANDLE NEEDS TO BE SECURED. SECURED R2 DOOR ASSIST HANDLE IAW AMM 25-21-25-420-801.
- 8 Jul 2026
Slide, unraveled
FWD ENTRY DOOR EMERGENCY SLIDE COMING OUT OF HOLDER. REPACKED FWD ENTRY DOOR SLIDE IAW AMM 25-66-01. OK FOR SERVICE.
- 9 May 2025
Brake, smoke
AT GATE ON FOS WALK AROUND HE SAW SMOKE FROM THE NUMBER #2 BRAKE. FUSE PLUG TO TIRE OPENED.<[01] PERFORMED HIGH ENERGY STOP CONDITIONAL INSPECTION FUSE PLUG…
- 3 Aug 2023
Flashlight, failed
COCKPIT FLASHLIGHT WILL NOT TEST<[01] RESET FLASHLIGHT OPS CHECKGOOD PER SIP
- 23 May 2023
Girt Bar, misaligned
FWD SERVICE DOOR SLIDE MISS ALIGNED; DIFFICULT TO ARM AND DISARM<[01] INSPECTED FWD SERVICE DOOR SLIDE GIRT BAR/ARMING. OPS CKS NORMAL PER AMM 25-66-02. A/C…
- 7 Nov 2022
Light, inoperative
EXTERIOR EMERGENCY LIGHIT INOP AFT OF FWD SERVICE DOOR / [01] RE LAMPED EXTERIOR EMERGENCY LIGHT AT AFT OF FWD SERVICE DOOR; OP CKD AND FOUND GOOD AS PER AMM…