N874AA
1978 Boeing 727-223 standard FAA →
registration
- 1978
service difficulty reports
40 reports
- 11 Nov 2001
Light, loose
MIA - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT LIGHT AT L1 LOOSE. SECURED EMERGENCY EXIT LIGHT AT L1. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)
- 14 Aug 2000
Light, inoperative
DFW DURING OVERNIGHT MAINTENANCE EMERGENCY EXIT ESCAPE PATH LIGHT STRIP UNDER EXIT PLACARD AT B5.440 INOPERATIVE. REPLACED LIGHT STRIP. SYSTEM GROUND CHECK…
- 15 Jun 2000
Switch, defective
SJU - FLT 1751 - WHEN FLAPS SELECTOR AT 5 DEGREES AMBER LEADING EDGE FLAPS LIGHT ILLUMINATED. ON LEO TEST PANEL, NO LIGHT FOR LEO FLAP 1. RECYCLED FLAPS BACK…
- 18 May 2000
Light, inoperative
TPA - FLT 2070 - DURING MAINTENANCE CHECK, EMERGENCY LIGHT ABOVE FORWARD GALLEY DOOR INOPERATIVE. REPLACED LIGHT ASSEMBLY. SYSTEM GROUND CHECK NORMAL…
- 15 May 2000
Stringer, corroded
TUL - FOUND 3 INCH SECTION OF STRINGER 29R HAS CORROSION AT STATION 1055. REMOVED CORRODED SECTION OF STR 29R AND SPLICE IN NEW SECTION PER AARD 53-30-07-2. (M)
- 12 May 2000
Shear Tie, cracked
TUL - FOUND SHEAR TIE CRACKED AT STATION 1263 LEFT STRINGER 11 AND ANGLE BEHIND THIS SHEAR TIE ALSO CRACKED. FABRICATED 301H/H STAINLESS STEEL DOUBLER,…
- 12 May 2000
Shear Tie, corroded
TUL - FOUND CORROSION ON SHEAR TIE AFT SIDE CORNER ABOVE 26 RIGHT AT STATION 720A. REMOVED AND REPLACED SHEAR TIE PER SRM 51-10-01. TREATED AND PRIMED ALL…
- 11 May 2000
Skin, bulged
TUL - FUSELAGE SKIN BULGING STATION 1093, STRINGER 27R. CORROSION ON FUSELAGE SKIN STATION 1093 AND STRINGER 27R STATION 1093. REPAIRED SKIN WITH DOUBLER PER…
- 11 Mar 2000
Light, shorted
MIA - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT ESCAPE FLOOR PATH LIGHTS IN ENTIRE CABIN INOPERATIVE. REPLACED EMERGENCY EXIT ESCAPE FLOOR PATH LIGHT…
- 9 Dec 1999
Transmitter, malfunctioned
ORD - FLT 1214 - DURING CLIMB, CABIN RATE OF CLIMB EXCEEDED 700 FEET PER MINUTE. CABIN CONTINUED TO CLIMB WITH CONTROL FULL CLOCKWISE. RETURNED AND LANDED ORD…
- 5 Dec 1999
Light, inoperative
MIA - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT PATH FLOOR LIGHTS IN FIRST CLASS INOPERATIVE. REPLACED EMERGENCY EXIT PATH FLOOR LIGHT STRIP. SYSTEM GROUND…
- 29 Oct 1999
Light, inoperative
DFW - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT FLOOR PATH LIGHTING IN AFT STAIRWELL INOPERATIVE. REPLACED EMERGENCY EXIT FLOOR PATH LIGHT ASSEMLBY IN AFT…
- 19 Jul 1999
Skin, corroded
TUL - FOUND CORROSION ON LOWER WING SKIN ABOVE RIGHT PRIMARY HEAT EXCHANGER. INSTALLED REPAIR PER SRM 57-30-3 FIG 8 SHEET 3. (M)
- 9 Jul 1999
Web, cracked
TUL - FOUND LEFT HORIZONTAL WEB CRACKED AIRSTAIR TORQUE BOX BELOW ACCESS PLATE STATION 1320. ROUTED OUT CRACK, REPAIRED AS PER B727 SRM CH 51-40-2, TYPICAL…
- 24 Jun 1999
Overheat Loop, defective
MIA - FLT 625 - AFTER TAEKOFF STRUT OVERHEAT LIGHT FLICKERED AT FL330. FLIGHT CREW PERFORMED EMERGENCY CHECKLIST AND LIGHT EXTINGUISHED. CLOSED NUMBER THREE…
- 9 Sep 1998
Light, inoperative
DFW - DURING OVERNIGHT MAINTENANCE, AFT AIR STAIRS EMERGENCY EXIT LIGHT INOPERATIVE. REPLACED AFT AIR STAIR EMERGENCY EXIT LIGHT ASSEMBLY. SYSTEM GROUND…
- 9 Sep 1998
Light, inoperative
DFW - DURING OVERNIGHT MAINTENANCE, MAIN CABIN OVERHEAD EMERGENCY EXIT LIGHT INOPERATIVE. REPLACED MAIN CABIN OVERHEAD EMERGENCY EXIT LIGHT ASSEMBLY. SYSTEM…
- 28 Jul 1998
Frame, dented
TUL - DENT IN UPPER FLANGE AT BELL FRAME STATION 620, BETWEEN STATION 24-25L. REMOVED DAMAGED AREA AND INSTALLED DOUBLER PER SRM 51-40-3, FIG 1 SHEET 3 PAGE…
- 28 Jul 1998
Floorbeam, corroded
TUL - CORROSION ON FLOORBEAM STATION 360 RBL 13 TO RBL 15. REPAIRED AREA OUT OF LIMIT PER SRM 53-10-08 PAGE 9C, 9D, 9E. (M)
- 28 Jul 1998
Floorbeam, corroded
TUL - FOUND CORROSION ON FLOORBEAM AT STATION 340 RBL 22 TO 24, RBL 13 TO 15, TOP AND BOTTOM SIDE OF TOP FLANGE RBL 14 TO 20, LBL 22. FLOORBEAM REPAIR…
- 28 Jul 1998
Stringer, corroded
TUL - FOUND CORROSION IN STRINGER CHANNEL, STATION 950B TO 1010, STRINGER 27L. REMOVED STRINGER 27 FROM 950B TO 1010. INSTALLED NEW STRINGER AND STRINGER…
- 28 Jul 1998
Casting, corroded
TUL - FOUND CORROSION ON TOP OF UPPER HINGE CASE FRAME ON FWD ENTRY DOOR CUT OUT. REMOVED AND REPLACED UPPER HINGE CASTING PER SRM 51-10-1. (M)
- 28 Jul 1998
Skin, corroded
TUL - RIGHT WING UPPER SKIN PANEL BULGING ARUOND FASTENERS JUST FORWARD OF APU EXHAUST CUT OUT 6 INCH AREA. REMOVED AND REPLACED WING SKIN PANEL WITH 8130…
- 28 Jul 1998
Frame, dented
TUL - BELL FRAME DENTED WEB BULGED STATION 1090 STRINGER 26L MARKED. CUT OUT DAMAGED ARE OF BELL FRAME. INSTALLED 'Z' ANGLE DOUBLER REPAIR PER SRM 53-10-4. (M)
- 28 Jul 1998
Frame, bent
TUL - BELL FRAME BENT STATION 990 STRIGNER 26L MARKED (WEB BULGED). CUT OUT DAMAGE AND INSTALLED 'Z' ANGLE DOUBLER REPAIR PER SRM 51-40-3. (M)
- 28 Jul 1998
Frame, damaged
TUL - FRAME 1110 DAMAGED AT STRINGER 27L. STOP DRILLED DAMAGED AREA AND INSTALLED DOUBLER PER SRM 51-40-3. (M)
- 28 Jul 1998
Frame, damaged
TUL - FRAME 1130 DAMAGED AT STRINGER 27R. STOP DRILLED DAMAGEA AREA AND INSTALLED DOUBLER PER SRM 51-40-3. (M)
- 22 Oct 1997
Spar, cracked
TUL - FOUND CRACK IN WING CENTER SECTION REAR SPAR WEB NEAR MILL CUT FROM RBL 3 TO RBL 5, WL 187 APPROX. REPAIRED PER ESO 11697. (M)
- 17 Mar 1997
Wire Harness, defective
DFW - FLT 1605 - AFTER TAKEOFF ATL WHEN LANDING GEAR RETRACTED AND AGAIN DURING APPROACH TO DFW WHEN LANDING GEAR EXTENDED, NOSE LANDING GEAR RED UNSAFE LIGHT…
- 27 Feb 1997
Stringer, corroded
TUL - FOUND CORROSION INSIDE STRINGER 26R AT STATION 1148. REMOVED CORRODED SECTION OF STRINGER STATION 1148-1152 STRINGER 26R AND REPAIRED STRINGER PER SRM…
- 27 Feb 1997
Shear Tie, corroded
TUL - FOUND CORROSION ON SHEAR TIE AND SKIN (STRAP). FABRICATED DOUBLER AND SHIM INSTALLED FILLER WASHERS TREAT AND PRIME DOUBLER PER ESO 11697, DATED…
- 27 Feb 1997
Shear Tie, corroded
TUL - FOUND CORROSION ON FRAME SHEAR TIE. REMOVED CORROSION ON FRAME AND REPLACED SHEAR TIE. (M)
- 27 Feb 1997
Shear Tie, corroded
TUL - FOUND CORROSION ON SHEAR TIE AND SKIN OUTBOARD OF STRINGER 26R AT STATION 1148. REPAIRED AREA USING FILLER AND DOUBLER PER ESO 11697, DATED 2-24-97 AND…
- 25 Feb 1997
Stringer, corroded
TUL - FOUND STRINGER 28R IS CORRODED ALONG BOTTOM AND BOTH INBOARD AND OUTBOARD SIDES FROM STATION 950F TO 970. ALODINED AND PRIMED AREA, INSTALLED REPAIR PER…
- 23 Feb 1997
Stringer, corroded
TUL - FOUND STRINGER 27L CORRODED, STATION 720F TO 740. REPAIRED PER SRM 53-10-3, TYPICAL STRINGER SPLICE. (M)
- 2 Dec 1996
Clamp, loose
MIA - FLT 1137 - AFTER TAKEOFF MIA DURING CLIMB, NR 3 ENGINE STRUT OVERHEAT LIGHT CAME ON. RETARDED THROTTLE AND STRUT OVERHEAT INDICATION EXTINGUISHED.…
- 3 Jul 1996
Deflector, out of adjust
FLT 443 - EN ROUTE MIA/CLE - DURING CRUISE, ODOR OF BURNING RUBBER IN CABIN, IN THE AREA OF MAIN W/W'S, W/NO OTHER ABNORM IND'S. A/C DIVERTED TO CLT AND…
- 28 May 1996
Angle, corroded
TUL - FOUND CREASE ANGLE FORWARD ENTRY DOOR CORRODED. INSTALLED NEW CREASE ANGLE AND SEALED, TREATED AND PRIMED PER SRM 51-10-6-20. (M)
- 6 Oct 1995
Dnlock Sensor, defective
DFW - FLT NR 1612 - DURING APPROACH DFW AFTER GEAR WAS CYCLED DOWN, THE LEFT MAIN GEAR DID NOT SHOW GREEN DOWN AND LOCKED. CYCLING GEAR HANDLE, STILL DID NOT…
- 29 Aug 1995
Switch Wire, broken
MIA - FLT NR 1111 - AFTER TAKEOFF MCO WHEN LANDING GEAR RETRACTED, UNSAFE NOSE LANDING GEAR INDICATION WITH ALL HYDRAULIC PRESSURE NORMAL. AIRCRAFT PROCEEDED…