Megaphone, inoperative
AFT MEGAPHONE INOPERATIVE. R & R THE AFT MEGAPHONE IAW AMM 25-64-00.
- 26 Oct 2026
Tailpipe, fire
SMALL FLAME FROM NR 2 ENGINE EXHAUST NOZZLE ON ENGINE SHUTDOWN. COMPLIED WITH EA M-23-172-03308-ETOPS TAIL PIPE FIRE INSPECION. OIL CONSUMPTION VERIFIED .09…
- 26 Sep 2026
Stiffener, cracked
STIFFENER FOUND CRACKED AT BS 251.6, LBL 4. LOCATED AND DRILLED A REPLACEMENT STIFFENER IAW SRM 51-40-05. R & R THE STIFFENER IAW SRM 51-40-02.
- 23 Sep 2026
Crossbeam, out of adjust
FLOOR CROSSBEAM, BS 540, LBL 24 - RBL 24, MISLOCATED COMMON TO FLOOR PANEL REMOVED, LOCATED, AND DRILLED THE CROSSBEAM IAW SRM 51-40-05.
- 16 Sep 2026
Scuff Plate, cracked
FORWARD CARGO, FORWARD CORNER SCUFF PLATE CRACKED. REMOVED AND INSTALLED SCUFF PLATE IAW AMM 53-11-02.
- 16 Sep 2026
Scuff Plate, cracked
FORWARD CARGO, AFT CORNER SCUFF PLATE CRACKED. REMOVED AND REPLACED THE SCUFF PLATE IAW AMM 53-11-02-401.
- 15 Sep 2026
Floorbeam, cracked
CABIN FLOORBEAM AT BS 540, LBL 1 CRACKED. R & R THE FLOORBEAM IAW SRM 51-40-02.
- 15 Sep 2026
Floorbeam, cracked
CABIN FLOORBEAM AT BS 540, RBL 1 CRACKED. REMOVED FLOORBEAM IAW SRM 51-40-02. INSTALLED A NEW FLOORBEAM IAW SRM 51-40-02.
- 10 Sep 2026
Angle, corroded
FWD ENTRY DOOR THRESHOLD MOST INBOARD ATTACH FASTENER HOLES ON Z ANGLE HAVE CORROSION AROUND THEM(PHOTO) FWD ENTRY DOOR THRESHOLD MOST INBOARD ATTACH FASTENER…
- 9 Sep 2026
Cam Roller, frozen
AFT SERVICE DOOR HANDLE CAM ROLLER IS FROZEN. BENCH CHECK OF BEARING IS GOOD PER SOPM 20-50-03.
- 9 Sep 2026
Mount, corroded
AFT PASSENGER CABIN, FOUND CORROSION UNDER LAV MOUNT AT BS 947, RBL 52, BLENDING ACCOMPLISHED ON EA 26-153-02451-WIP1, STEP 5. REMOVED .033" OF MATERIAL.…
- 9 Sep 2026
Angle, corroded
AFT SERVICE DOOR THRESHOLD: CORROSION FOUND ON Z ANGLE AT BS 984 - 995. BLENDED CORROSION ON AFT SERVICE DOOR Z ANGLE AND FOUND TO BE OUT OF LIMITS IAW SRM…
- 9 Sep 2026
Angle, corroded
AFT SERVICE DOOR THRESHOLD CORRODED ON Z ANGLE AT BS 957. BLENDED CORROSION, ORIGINAL MATERIAL THICKNESS IS 0.080 MATERIAL LOSS IS 0.013 MAX ALLOWED IS 0.008…
- 9 Sep 2026
Angle, corroded
AFT SERVICE DOOR THRESHOLD: CORROSION FOUND ON Z ANGLE AT BS 950. BLENDED CORROSION ORIGINAL MATERIAL THICKNESS IS 0.080 MATERIAL LOSS IS 0.013 MAX ALLOWED IS…
- 9 Sep 2026
Angle, corroded
AFT SERVICE DOOR THRESHOLD CORRODED, FOUND ON Z ANGLE IN MULTIPLE AREAS FROM BS 967-986.5. FOUND TO BE OUT OF LIMITS IAW SRM 53-7-15-1A-1. REMOVED THE ANGLE…
- 9 Sep 2026
Mount, corroded
AFT PASSENGER COMPARTMENT: FOUND CORROSION UNDER LAV MOUNT AT STA 947 LBL 52 BLENDING ACCOMPLISHED ON EA 26-153-02451-WIP1 (TTG8Q01E7B8L) STEP 5. REMOVED…
- 8 Sep 2026
Floorbeam, corroded
NUTCLIP HOLE ON CABIN FLOOR BEAM STA.328, RBL 39.5 HAS CORROSION ON LOWER SURFACE. REMOVED DAMAGE IAW SRM 51-10-02. REMOVED 0.009. MAX, REMAINING 0.121.…
- 8 Sep 2026
Floorbeam, corroded
NUTCLIP HOLE ON CABIN FLOORBEAM BS 328, RBL 47.5 WAS CORRODED ON LOWER SURFACE. REMOVED DAMAGE IAW SRM 51-10-02. MATERIAL REMOVED 0.027. MAX MATERIAL…
- 5 Sep 2026
Access Panel, delaminated
ACCESS PANEL 627BT, FOUND FWD BOTTOM CORNER DELAMINATING. REPAIRED THE DAMAGE AT CORNER OF ACCESS PANEL 627BT AND RESTORED ALL FINISHES IAW SRM 51-70-04-2R-13.
- 5 Sep 2026
Attach Angle, cracked
RIGHT A/C BAY, BS 663, RBL 9, VAPOR BARRIER ATTACH ANGLE WAS CRACKED. REPAIR ACCOMPLISHED IAW EA M-26-157-01143.
- 14 May 2026
Battery Pack, inoperative
RH FWD EMERGENCY LIGHTS INOP. R&R FWD CENTER GALLEY EMERGENCY LIGHT BATTERY PACK IAW AMM 33-51-06. OPS CHECK GOOD.
- 14 May 2026
Battery Pack, inoperative
LH FWD EMERGENCY LIGHTS INOP<[01] R&R'D LH FWD GALLEY EMERGENCY LIGHT BATTERY PACK IAW AMM 33-51-06. OPS CHECK GOOD.
- 28 Apr 2026
Web, cracked
NR 1 ENGINE LH PYLON AFT SUPRESSION WEB CRACKED. INSPECTION REVIEWED THIS FAULT. (REPAIR 7 - AFT FAIRING PLUME SUPPRESSOR-DVI EVERY 30 DAYS FOR 3 MONTHS; THEN…
- 12 Apr 2026
Lamp, inoperative
AFT F/A CALL LIGHT INOP (BLUE). RELAMPED EXIT SIGN AFT FLIGHT ATTENDANT CALL LIGHT BLUE IAW AMM 33-51-01. OPS CHECK GOOD.
- 27 Jan 2026
Sill Drain, odor
HORRIBLE SULFUR ODOR COMING FROM FWD FLOOR DRAINS ON EACH SIDE OF AFT GALLEY. THE ODOR WAS INTERMITTENT WHILE ACFT OPERATING. ONE FLT ATTENDANT GAGED. FLOOR…
- 18 Aug 2025
Holder, loose
FWD SERVICE DOOR GIRT BAR HOLDER IN THE UNARMED BRACKET WILL NOT HOLD THE BAR SECURE. COMPLIED WITH EA M-23-125-01839
- 7 Jun 2025
Girt Bar, loose
FORWARD MAIN ENTRY GURT BAR LOOSE FO SIDE FRONT<[01] OBSERVED R1 DOOR GIRT BAR STOWED. NO MAINTENANCE ACTION IS REQUIRED PER SIP.
- 10 Dec 2024
Battery, inoperative
EMERGENCY FLASHLIGHT FWD GALLEY DOES NOT TEST PROPERLY<[01] REMOVED AND REPLACED FLASHLIGHT BATTERY; OP-CKS GOOD PER 25-64-00.
- 1 Dec 2024
Battery, inoperative
EMERGENCY EXIT LIGHTS ASSOCIATED WITH M1694 ARE INOP<[01] REMOVED AND REPLACED EMERGENCY EXIT LIGHTS BATTERY M1694 AND TESTED GOOD PER AMM…
- 1 Dec 2024
Fuse, inoperative
L1365 R/H LOWER FWD EMERG. EXIT DOOR LOCATOR IS INOP.<[01] REMOVED AND REPLACED FUSE ON M1695 AND TEST GOOD PER WDM 33-51-11 AND AMM 33-51-06-960-801;[02]…
- 31 Oct 2024
Slide, loose
FWD SERVICE DOOR SLIDE LOOSE<[01] REPLACED THE FWD SERVICE DOOR SLIDE ASSAY. REF 25-66-01
- 25 Sep 2024
Bulb, inoperative
AFT SERVICE DOOR EXTERIOR EMERGENCY EXIT LIGHT BULB INOP<[01] 01 - REMOVED AND REPLACED PER [AMM 33-51-04-960-801-MAX (SLIDE/OVERWING LIGHT - LAMP REPLACEMENT…
- 18 Jun 2024
Fairing, cracked
FOUND CRACK ON ENG #2 AFT STRUT FAIRING ABOVE EXHAUST PLUG ASSEMBLY TWO CRACKS ON THE STRUT FAIRING. FIRST CRACK IS 6 INCHS LONG AND 1/16TH OF AN INCH WIDE…
- 1 May 2024
Megaphone, inoperative
AFT MEGAPHONE INOP<[01] 01 - REMOVED AND REPLACED PER [AMM 25-64-00-710-801-MAX (MEGAPHONE OPERATIONAL TEST - PERMANENT)]
- 26 Mar 2024
Megaphone, inoperative
MEGAPHONE INOP<[01] R&R'D MEGAPHONE IAW AMM 25-64-00. OPS CHECK GOOD. A/C OKAY FOR SERVICE
- 18 Oct 2023
Flashlight, failed
RIGHT SIDE FORWARD GALLEY FLASHLIGHT WILL NOT TEST<[01] REMOVED AND REPLACED RIGHT SIDE FOWARD F/A FLASHLIGHT BATTERY IN REF TO AMM 25-64-00. OPS TEST GOOD.…
- 17 Oct 2023
Flashlight, failed
CREW REPORTS FLIGHT DECK EMERGENCY FLASHLIGHT CHARGER LED STATUS LIGHT INOP<[01] OK TO CONTINUE PER MEL 25-64-02A SP1B. AUTH# 161890;[02] REMOVED AND REPLACED…
- 15 Oct 2023
Flashlight, inoperative
FWD FLIGHT ATT FLASHLIGHT INOP<[01] PERFORMED OPS CHECK OF FLASHLIGHT; OPS CHECK GOOD IAW AMM 25-64-00
- 22 Sep 2023
Scuff Plate, cracked
AFT CARGO COM[ARTMENT FWD CORNER SCUFF PLATE IS CRACKED ON UPPER AFT SURFACE<[01] REMOVED AFT CARGO FWD CORNER SCUFF PLATE IAW SRM 53-60-15-2R-1 STEP…
- 19 Sep 2023
Battery Pack, inoperative
AFT CABIN RIGHT SIDE EMERG LIGHTS ARE INOP<[01] REMOVED AND REPLACED BATTERY FOR THE AFT CABIN RIGHT SIDE EMERG LIGHTS THAT WERE INOP. IAW AMM…
- 19 Sep 2023
Battery Pack, inoperative
MIDDLE LEFT OWE EMERG EXIT SIGN IS INOP. M1695<[01] REPLACED EMERG LIGHT BATTERY PACK M1695 AT STA 565 R/H IAW AMM 33-51-06-960-802. TESTS GOOD;[02] VERIFIED…
- 19 Sep 2023
Battery Pack, inoperative
MULTIPLE RIGHT SIDE CABIN EMERG LIGHTS ARE INOP FOR M1671<[01] REMOVED AND REPLACED BATTERY PACK FOR M1671 IAW AMM 33-51-06-960-801; LIGHTS CHECK GOOD.;[02]…
- 19 Sep 2023
Battery Pack, inoperative
MULTIPLE RIGHT SIDE EMERG LIGHTS ARE INOP FOR M1676<[01] REPLACED EMERG LIGHT BATTERY PACK M1676 AT STA 500C IAW AMM 33-51-06-960-802;[02] REPLACED EMERG…
- 17 Sep 2023
Floor Support, corroded
DOT A24-77 AFT PIT RH Z-ANGLE SUPPORT INTERCOSTAL BETWEEN STATIONS 747-767 CORRODED ON LOWER SIDE UNDER REMOVED BONDED NUT PLATES.<[01] BLENDED CORROSION IAW…
- 15 Sep 2023
Baffle, cracked
FWD CARGO HAS CRACKED BAFFLE AT R/H SIDE BETWEEN STA550A AND 500B AFT CORNER RBL 23<[01] REMOVED AND REPLACED BAFFEL BS 500A-500B IAW SRM 51-40-02-0G-0DWD…
- 14 Sep 2023
Floor Panel, corroded
DOT#31-043 FWD CARGO COMPARTMENTFLOOR PANEL 120DF HAS CORROSION ON EDGE OF PANEL<[01] AUDIT C/W.
- 13 Sep 2023
Angle, corroded
DOT#19-043 AFT CARGO COMPARTMENT RH 'Z' ANGLE CORRODED STA 727B+6' TO 727D+16' RBL 24 WL 156<[01] BLENDED CORROSION IAW SRM 51-10-02 AND VERIFIED WITH 10X AND…
- 13 Sep 2023
Angle, corroded
DOT#20-043 AFT CARGO COMPARTMENT LH 'Z' ANGLE CORRODED STA 727C+6' TO 787+11' LBL 24 WL 156<[01] SUMMARY STATEMENT: REMOVED CORROSION FROM AFT CARGO LEFT HAND…
- 13 Sep 2023
Angle, corroded
DOT#21-043 AFT CARGO COMPARTMENT RH 'Z' ANGLE CORRODED STA 727H+6' TO 747D+14' RBL 24 WL 156<[01] BLENDED CORROSION IAW SRM 51-10-02 AND VERIFIED WITH 10X AND…
- 13 Sep 2023
Shield, corroded
DOT#25-043 AFT CARGO COMPARTMENT RH FWD SHIELD CORRODED STA 767+3' RBL 24 WL 156<[01] AUDIT C/W.
- 13 Sep 2023
Angle, cracked
DOT#27-043 AFT CARGO COMPARTMENT VACUUM WASTE COMPARTMENT BKHD STANTION LOWER LEEK ANGLE CRACKED STA 847+18' LBL 10 WL 156<[01] REMOVED AND REPLACED ANGLE IN…
- 12 Sep 2023
Shield, corroded
DOT#07-043 FWD CARGO COMPARTMENT; RH AFT SHIELD CORRODED AT STA 500+20' LBL 25 WL 156<[01] REMOVED CORROSION VISUALLY INSPECTED AREA WITH 10X NO DEFECTS NOTED…
- 12 Sep 2023
Angle, corroded
DOT#08-043 FWD CARGO COMPARTMENT; LH 'Z' ANGLE CORRODED AT STA 500+20' LBL 24 WL 156<[01] CORROSION BEEN REMOVED BY TREVON THOMAS 28136 VISUALLY INSPECTED…
- 12 Sep 2023
Angle, corroded
DOT#11-043 FWD CARGO COMPARTMENT; LOWER BKHD ANGLE CORRODED AT STA 500I LBL 24 TO RBL 24 WL 156<[01] REMOVED CORRODED FWD CARGO COMPARTMENT LOWER BKHD ANGLE…
- 12 Sep 2023
Angle, corroded
DOT#12-043 FWD CARGO COMPARTMENT; RH 'Z' ANGLE CORRODED AT STA 500A TO 500H RBL 24 WL 156<[01] CORROSION BEEN REMOVED BY TREVON THOMAS 28136 VISUALLY…
- 12 Sep 2023
Angle, corroded
DOT#09-043 FWD CARGO COMPARTMENT; LH 'Z' ANGLE CORRODED AT STA 500C+11' TO 500D+7' LBL 24 WL 156<[01] CORROSION BEEN REMOVED BY TREVON THOMAS 28136 VISUALLY…
- 12 Sep 2023
Angle, corroded
DOT#10-043 FWD CARGO COMPARTMENT; LH 'Z' ANGLE CORRODED AT STA 500H+16' LBL 24 WL 156<[01] CORROSION BEEN REMOVED BY TREVON THOMAS 28136 VISUALLY INSPECTED…
- 11 Sep 2023
Floor Panel, corroded
DOT A160-64; AFT CARGO FLOOR PANEL 140DF HAS LIGHT CORROSION ON BACKSIDE AROUND FASTENER HOLES<[01] EVALUATED CORROSION AND DETERMINED AREA EXCEEDS MAX LIMITS…
- 11 Sep 2023
Floor Panel, corroded
DOT A160-65; AFT CARGO FLOOR PANEL 140AF; HAS LIGHT CORROSION ALONG THE PARAMETER ON FWD SIDE<[01] FAULT RESOLVED ON OTHER FALUT; SEE FAULT TTG8Q00NCNVY FOR…
- 11 Sep 2023
Floor Panel, corroded
DOT A160-66; AFT CARGO FLOOR PANEL 140AF HAS LIGHT CORROSION ALONG THE PARAMETER OF FWD SIDE<[01] UPON FURTHER INVESTIGATION FOUND CORROSION TO EXTEND FURTHER…
- 11 Sep 2023
Floor Panel, corroded
DOT A160-67; AFT CARGO FLOOR PANEL 140BF HAS LIGHT CORROSION ALONG THE PARAMETER OF FWD SIDE<[01] EVALUATED CORRODED AREA CORROSION IS MORE THAN 3' IN LENGTH…
- 11 Sep 2023
Floor Panel, corroded
DOT A160-68; AFT CARGO FLOOR PANEL 140DF HAS LIGHT CORROSION AROUND FASTENER HOLES ON THE BACKSIDE<[01] FLOOR PANEL 140DF BEEN FABRICATED ON N/R TTG8Q00NCNVD…
- 11 Sep 2023
Floor Panel, corroded
DOT A160-62; AFT CARGO FLOOR PANEL 140CF HAVE LIGHT CORROSION ON BACKSIDE AROUND FASTENER HOLES<[01] BLENDED CORROSION IAW SRM 51-10-02 FOUND A TOTAL LENGTH…
- 11 Sep 2023
Floor Panel, corroded
DOT A160-61; AFT CARGO FLOOR PANEL 140CF HAS LIGHT CORROSION ALONG THE FWD PARAMETER<[01] FAULT BEEN RESOLVED ON EA 23-153-02828;[02] VERIFIED ITEM 1<BR>AUDIT…
- 9 Sep 2023
Battery Pack, inoperative
AFT LH EMERGENCY LIGHTS ARE INOP (M01673)<[01] REMOVED AND REPLACED BATTERY PACK AFT L/H IAW AMM 33-51-06-960-805 OP TEST GOOD;[02] IAW AMM…
- 8 Sep 2023
Floor Panel, debonded
PASSENGER CABIN FLOOR PANEL 241BF IS DISBONDED ON FWD EDGE DOT 050-003<[01] CLEANED FLOORBOARD IAW SRM 53-00-50-2R-0 REPAIR GENERAL PARAGRAPH 5 A (1);[02] C/W…
- 8 Sep 2023
Floor Panel, debonded
PASSENGER CABIN FLOOR PANEL 241FF IS DISBONDED ON FWD INBOARD EDGE DOT 050-002<[01] CLEANED FLOORBOARD IAW SRM 53-00-50-2R-0 REPAIR GENERAL PARAGRAPH 5 A…
- 2 Sep 2023
Flashlight, inoperative
FWD OUTBOARD FLASHLIGHT INOP<[01] REMOVED AND REPLACED FWD OUTBOARD FLASHLIGHT BATTERY REF AMM 25-64-00
- 1 Jul 2023
Battery Pack, inoperative
EMER LIGHTS IN CABIN ASSOCIATED WITH EMER BATT PACK M2335 INOP<[01] REMOVED AND REPLACED BATTERY PACK AND CHARGER ASSEMBLY FOR EMERGENCY LIGHTS AT M2335 PER…
- 13 Jun 2023
Skin, cracked
ENG #1 INBOARD HALF OF THRUST REVERSER HAS A CRACK AT 7 OCLOCK POSITION ON THE INSIDE OF THE THRUST REVERSER.<[01] REPAIRED PER EA 23-154-01895;[02] ADDED…
- 28 May 2023
Light, inoperative
LEFT OVER WING EXTERIOR FWD EMERGENCY LIGHT INOP.<[01] RELAMPED LEFT OVER WING EXTERIOR FWD EMERGENCY LIGHT; OPS CHECK GOOD. REF AMM 33-51-04.
- 26 May 2023
Light, inoperative
FWD LEFT OVER WING EMERGENCY EXIT EXTERIOR EMERGENCY LIGHT INOP.<[01] RELAMPED PER AMM33-51-04
- 30 Sep 2022
Flashlight, no test
FORWARD FLIGHT ATTENDANT EMERGENCY FLASHLIGHT WILL NOT TEST. OK TO CONTINUE PER MEL 25-64-02. SP#1B;[02] OK TO CONTINUE PER MEL 25-64-02. SP#1B;[03] REMOVED…
- 13 Aug 2022
Battery, inoperative
FWD OUTBOARD FLIGHT ATTENDANT FLASHLIGHT INOP. / [01] OK TO CONTINUE PER MEL: 25-64-02 SP1B<BR>AUTHORIZATION # 81611.;[02] REPLACED FWD O/B FA FLASHLIGHT…
- 19 Jul 2022
Slide, out of position
R2 DOOR SLIDE AJAR / [01] REPOSITIONED SLIDE PER SIP; NO DEFECTS NOTED
- 10 Feb 2022
Floor Panel, loose
CENTER AISLE FLOOR LOOSE AT ROW 16. ; / [01] SECURED CENTER AISLE FLOOR AT ROW 16 IAW AMM 53-21-00
- 6 Jan 2022
Lamp, inoperative
FOUND EMERGENCY LIGHT BY FWD SERVICE DOOR INOP. RE-LAMPED EMERGENCY LIGHT BY FWD SERVICE DOOR IAW AMM 33-51-04. OPS CHECK GOOD
- 8 Oct 2021
Slide, low pressure
FWD SERVICE DOOR SLIDE LOW PRESSURE / REMOVED AND REPLACED FWD SERVICE DOOR SLIDE PER MT 825-PRD-01-01 GRB #991523 ISSUE #3509919PN OFF/ON 5A3307-7 SN OFF…
- 19 Apr 2021
Slide, displaced
AFT SERVICE DOOR EMERGENCY EXIT SLIDE MANUAL DEPLOY HANDLE COVER NOT VISIBLE / REPOSITIONED MANUAL INFLATION HANDLE COVER IAW AMM 25-66-01. AIRCRAFT OK FOR…
- 1 Mar 2021
Battery Pack, inoperative
EMERGENCY LIGHTS COMMON TO M1670 ARE INOPERATIVE. / REMOVED AND REPLACED BATTERY PACK AT POWER SUPPLY M1670 AND PERFORMED GOOD CHECK OF EMERGENCY LIGHTS…
- 16 Feb 2018
Flashlight, unsecure
FORWARD GALLEY FLASHLIGHT OUTBOARD POSITION INOPERATIVE. RESET THE FLASHLIGHT IN THE CRADLE IAW AMM.
- 24 Dec 2017
Lens, missing
RIGHT OVERWING EXIT LIGHT LENS MISSING. INSTALLED THE LIGHT ASSY IAW MM.