- 8 Aug 2001
Bear Strap, cracked
TUL - FOUND LOW FREQUENCY EDDY CURRENT INDICATES CRACK PROGRESSING FROM FASTENER ON AFT LWR FORWARD GALLEY DOOR CUTOUT. TRIMMED OUT DAMAGE AT BARE STRAP AND…
- 7 Aug 2001
Battery Pack, discharged
TUL - FOUND LEFT AND RIGHT FORWARD DOOR SLIDE LIGHTS FAILED 10 MINUTE CHECK. REPLACED FORWARD DOOR SLIDE LIGHT BATTERY PACK. (M)
- 7 Aug 2001
Battery Pack, discharged
TUL - FOUND RIGHT FORWARD AND AFT OVERWING EXIT EMERGENCY LIGHTS FAIL 10 MINUTE CHECK. REPLACED OVERWING EMERGENCY EXIT SIGN BATTERY PACK. (M)
- 7 Aug 2001
Battery Pack, discharged
TUL - FOUND CENTER AISLE OVERHEAD FORWARD AND AFT OVERWING AREA EMERGENCY EXIT LIGHTS FAIL 10 MINUTE CHECK. REPLACED AISLE SIGN EMERGENCY EXIT BATTERY PACK. (M)
- 6 Aug 2001
Skin, gouged
TUL - FOUND GOUGE IN SKIN AT STATION 936 BETWEEN STRINGER 3R AND 4R. INSTALLED DOUBLER REPAIR AT STATION 936 BETWEEN STRINGER 3R AND 4R PER SRM 53-30-3 PART…
- 6 Aug 2001
Shear Tie, corroded
TUL - FOUND SHEAR TIE CORRODED AT STATION 520 STRINGER 26 TOP SIDE. REMOVED AND REPLACED SHEAR TIE IAW SRM 51-10-1, TREATED, PRIMED PAINTED IAW MM 51-20-0. (M)
- 28 Feb 2001
Wire, loose
MIA - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT LIGHT AT SEAT 13D INOPERATIVE. RE-SECURED EMERGENCY EXIT LIGHT WIRE AT SEAT 13D. SYSTEM GROUND CHECKED…
- 22 Sep 2000
Skin, corroded
TUL - INTERGRANULAR CORROSION ON LOWER WING SKIN LEFT PRIMARY HEAT EXCHANGER AT STA 3, 4, AND 5, LBL 16 LBL 36. BLENDED OUT CORROSION. FABRICATED REPAIR…
- 21 Sep 2000
Light, inoperative
TUL - FOUND EMERGENCY FLOOR LIGHT STRIP REMOVED. INSTALLED SERVICEABLE LIGHT STRIP PER MM 33-60-098-4 AND OPS CHECKED GOOD. (M)
- 20 Sep 2000
Floorbeam, corroded
TUL - FLOOR BEAM AT STA 380 HAD CORROSION BETWEEN OUTBOARD SEAT TRACKS UNDER FORWARD GALLEY. REMOVED DAMAGED AREA AND INSTALLED DOUBLER PER ESO 11697 DATED…
- 19 Sep 2000
Beam, cracked
TUL - VERTICAL BEAM CRACKED, STA 1183, RBL 36 WL 238. STOP DRILLED CRACK AND INSTALLED REPAIR MODIFICATION PER SB 727-53-0192 AND DWG 65C34406. (X)
- 18 Sep 2000
Beam, cracked
TUL - VERTICAL BEAM CRACKED AT LOWER END STA 1183 RBL 8. STOP DRILLED CRACK AND INSTALLED DOUBLER REPAIR IAW SB 727-53-0175. (X)
- 18 Sep 2000
Shear Tie, damaged
TUL - SKIN BULGED ON THE BELL FRAME FORWARD END OF INTERCOSTAL MARKED STA 1050, STR 27L. INSTALLED NEW SHEAR TIE PER SRM 51-30-2. (X)
- 17 Sep 2000
Skin, corroded
TUL - WING CENTER SECTION, LOWER SKIN HAD CORROSION AT RIGHT PLENUM. REMOVED CORROSION AND INSTALLED DOUBLER PER SRM 57-30-3. (X)
- 16 Sep 2000
Fitting, corroded
TUL - CORROSION ON FACES OF VERTICAL FIN, PIVOT LUGS, AND CORROSION ON HORIZONTAL STABILIZER PIVOT BORES AND FACES. REMOVED CORROSION PER SRM 51-10-2 AND SRM…
- 15 Sep 2000
Flap, corroded
TUL - CORROSION ON GROUND ATTACH BOLT AT NR 2 LEADING EDGE FLAP, OUTBOARD. INSTALLED DOUBLER PER ESO 11697 DATED 9-14-00. (X)
- 29 May 2000
Light, inoperative
DFW - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT LIGHTS AT ROW 23 EXTINGUISHES AFTER APPROXIMATELY 30 SECONDS FROM ACTIVATION. REPLACED EMERGENCY EXIT LIGHT…
- 28 Mar 2000
Connector, failed
ORD - FLT 2283 - DURING APPROACH, RED NOSE GEAR LIGHT ON FORWARD INSTRUMENT PANEL DOES NOT ILLUMINATED WHEN GEAR EXTENDED. GEAR DID EXTEND AND LANDED ORD…
- 28 Mar 2000
Motor, failed
DFW - FLT 2063 - AFTER TAKEOFF DFW, AIRCRAFT EXPERIENCED HYDRAULIC SYSTEM 'A' FLUID LOSS. ACCOMPLISHED ABNORMAL PROCEDURES, INCLUDING MANUAL GEAR EXTENSION.…
- 27 Mar 2000
Wire, broken
MIA - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT ESCAPE PATH LIGHTS FORWARD PART OF COACH INOPERATIVE. REPAIRED EMERGENCY EXIT ESCAPE PATH LIGHT WIRE…
- 31 Oct 1999
Connector, loose
DFW - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT SIGN ABOVE AFT GALLEY IS BLINKING ON AND OFF WITH LIGHT SWITCH IN THE ON POSITION. RE-SEATED EMERGENCY EXIT…
- 17 Sep 1999
Spar, corroded
TUL - FOUND CORROSION ON LOWER SPAR CHORD BELOW NR 6 SLAT ACTUATOR. INSTALLED REPAIR STRAP IAW AARD 57-30-00-2 PAGES 1-3. (M)
- 17 Sep 1999
Skin, gouged
TUL - FOUND GOUGE IN SKIN AT STATION 660 BETWEEN STRINGER 1 AND 2R. CUT OUT DAMAGED AREA AND INSTALLED DOUBLER PER SRM 53-30-3 FIG 1. (M)
- 17 Sep 1999
Skin, gouged
TUL - FOUND DEEP GOUGE IN SKIN AT STATION BETWEEN STRINGERS 1 AND 2R. CUT OUT DAMAGED AREA AND INSTALLED DOUBELR PER SRM 53-30-3 FIG 1. (M)
- 17 Sep 1999
Frame, misdrilled
TUL - FOUND BELTFRAME DRILLED INTO 4 PLACES UPPER LEG STATION 560 BETWEEN STRINGER 28R AND 27R. INSTALLED DOUBLERS PER AARD 51-40-1. (M)
- 15 Sep 1999
Skin, corroded
TUL - FOUND BULGE IN SKIN LAP 26L FROM BS 990 PLUS 9 INCHES TO 990 PLUS 13 INCHES. REMOVED CORRODED PORTION OF SKIN AND INSTALLED DOUBLER PER SRM 53-30-3. (M)
- 25 Sep 1998
Skin, corroded
TUL - BULGE IN SKIN STATION 680 BETWEEN STRINGER 26 AND 27. INSTALLED NEW SERVICEABLE STRINGER SPLICE AND REINSTALLED INTERCOSTAL PER SRM 53-10-3 PAGE 3. (M)
- 25 Sep 1998
Stringer, corroded
TUL - FOUND STRINGER 27L AT BS 670 HAS CORROSION AT STANDOFF INSIDE OF STRINGER. REMOVED DAMAGED SECTION OF STRINGER AND INSTALLED FILLER AND DOUBLER AT…
- 25 Sep 1998
Stringer, corroded
TUL - BULGE IN SKIN STATION 680 BETWEEN STRINGER 26 AND 27. INSTALLED NEW SERVICEABLE STRINGER SPLICE AND REINSTALLED INTERCOSTAL PER SRM 53-10-3 PAGE 3. (M)
- 5 Jul 1998
Light, inoperative
MIA - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT LIGHT AT R1 DOOR INOPERATIVE. REPLACED EMERGENCY EXIT LIGHT AT R1 DOOR. SYSTEM GROUND CHECKED NORMAL…
- 21 Oct 1997
Control, defective
IAD - FLT 0637 - AFTER TAKEOFF DCA DURING CLIMB-OUT ELECTRICAL ODOR NOTED IN CABIN AND COCKPIT. AIRCRAFT DIVERTED TO IAD AND LANDED WITHOUT INCIDENT. REPLACED…
- 3 Oct 1997
Floor Beam, corroded
TUL - STA 380 FLOOR BEAM HAS CORROSION BETWEEN RT INBD TIE-DOWN TRACK AND RT CREASE ANGLE. REMOVED CORRODED PIECE OF FLOOR BEAM PER SRM 53-10-8. REPLACED WITH…
- 3 Oct 1997
Frame, corroded
TUL - FRAME CORRODED AT FLOOR LEVEL 4 INCHES FORWARD OF FORWARD GALLEY DOOR. INSTALLED REPAIR IAW SRM. 55,509 HOURS. CYCLES, 33,962. (X)
- 3 Oct 1997
Skin, corroded
TUL - CORROSION UNDER FLANGE OF ICE LIGHT BOX LEFT SIDE (WING SCANNING LIGHT). BLENDED CORROSION PER SMR 51-10-6, CORROSION OUT OF LIMITS, INSTALLED DOUBLER…
- 3 Oct 1997
Bell Frame, bent
TUL - LEFT STA 970 BELL FRAME BENT BETWEEN STR 25 AND STR 26 LEFT. REMOVED DAMAGED AREA AND INSTALLED DOUBLER PER SRM 51-40-3. 55,509 HOURS. CYCLES 33,962. (X)
- 3 Oct 1997
Web, corroded
DELTA BEAM LOWER WEB CORRODED AT STA 770 TO STA 760. REPLACED WEB STA 740 TO STA 770. TST: 55,509 HOURS. CYCLES, 33,962. (X)
- 3 Oct 1997
Stringer, dented
TUL - STRINGER 21R TOP FLANGE DENTED STA 448 -. DOUBLER INSTALLED OVER MINOR DENT INSIDE FUSELAGE IN STR 21R STA 448 PER SRM 53-10-3, FIG 1, PAGE 4B. TST:…
- 3 Oct 1997
Stringer, cracked
STR 15L AT WING SCANNING LIGHT STA 720B + 5 AND 720B +15 CRACKED FORWARD OF AND AFT OF LIGHT BOX AT STRINGER ENDS. REPAIRED STRINGER ENDS FORWARD AND AFT OF…
- 2 Oct 1997
Frame, corroded
TUL - FRAME CORRODED AT FLOOR LEVEL 4 INCH FORWARD OF FORWARD GALLEY DOOR. INSTALLED REPAIR IAW SRM 51-40-3 FIG 1. (M)
- 2 Jul 1997
Pump, defective
MIA - FLT 2143 - EN ROUTE HAD SYSTEM 'A' HYDRAULIC LEAK/LOSS. GEAR WAS MANUALLY CRANKED DOWN. GPWS DEACTIVATED, FUEL DUMPED USED, GEAR PINS USED FROM POUCH,…
- 21 Oct 1996
Controller, defective
TPA - FLT 1629 - AFTER TAKEOFF MIA DURING CLIMB-OUT, PASSING THRUOGH FL 290, CABIN ALTITUDE BEGAN TO CLIMB WITH ASSOCIATED WARNING HORN. CLOSED BOTH OUTFLOW…
- 30 Nov 1995
Floor Beam, corroded
TUL - FOUND CORROSION ON TOP OF FLOOR BEAM AT FASTENER HOLE STATION 1110 LBL 28 INCHES. CUT OUT DAMAGED AREA INSTALLED FILLER AND DOUBLER PER SRM 53-10-8 PG…
- 30 Nov 1995
Beam, cracked
TULE - FOUND 1183 VERTICAL BEAM CRACKED IN OUTBOARD RADIUS LBL 8 LOWER END ONE INCH LONG. INSTALLED VERTICAL BEAM REPAIR PER SB 727-53-0175.
- 30 Nov 1995
Skin, damaged
TULE - FOUND LEFT LOWER SURFACE OF ELEVATOR DAMAGED. REMOVED LOWER LEFT ELEVATOR SKIN AND REPLACED WITH NEW SKIN. (M)
- 25 Mar 1995
Eel Connector, broken
MIA - DURING OVERNIGHT CHECK, EMERGENCY FLOOR LIGHTING BY FWD GALLEY INOPERATIVE. REPLACED BROKEN EMERGENCY FLOOR LIGHT CONNECTOR BY FWD GALLEY. SYSTEM GROUND…
- 2 Mar 1995
Duct, blown
JFK-MIA - FLT 743 - AFTER TAKEOFF, THE LOWER BODY OVERHEAT LIGHT ILLUMINATED AND A LOUD THUD HEARD BY FLIGHT ATTENDANTS. PULLED NR 2 ENGINE TO IDLE TO…