N866AT
2025 Piper PA-44-180 standard FAA →
registration
- 2025
earlier registrations
1 past record
service difficulty reports
53 reports
- 16 Oct 2026
Downlock Switch, defective
WHILE THE LANDING GEAR WAS DOWN AND LOCKED THE INDICATION ON DISPLAYS SHOWED AN UNSAFE NOSE GEAR. WHILE TROUBLESHOOTING IT WAS FOUND THAT THE NOSE GEAR…
- 9 Apr 2002
Actuator, sticking
FORWARD NOSE GEAR DOOR REMAINED OPEN ON DEPARTURE/BURNED DOWN FUEL, RETURNED TO BASE. FOUND NOSE GEAR DOOR MANUAL ACTUATOR STICKING, LUBED ACTUATOR AND…
- 3 Mar 2002
Wire, broken
DURING EMERGENCY LIGHTING CHECK OUT FOUND TAIL CONE EMERGENCY RELEASE HANDLE LIGHT INOP. FURTHER INVESTIGATION REVEALED POSITIVE WIRE CUT IN HALF 2 FEET FROM…
- 29 Nov 2001
Battery, discharged
FOUND EMERGENCY LIGHTS WILL NOT EXTINGUISH. CORRECTIVE ACTION: REMOVED AND REPLACED NICAD BATTERY PACK, D5-28, B5-27. IAW DC9 MM 33-50
- 12 Feb 2001
Proximity Sensor, out of adj
AIRCRAFT WOULD NOT TRANSFER TO FLIGHT MODE. AIRCRAFT WAS FERRIED FOR TROUBLESHOOTING. RIGGED AND ADJUSTED GROUND SENSE MECHANISM AND SERVICED NOSE STRUT IAW…
- 12 Jan 2001
Strut, discharged
UNABLE TO RAISE GEAR ON TAKEOFF. SUSPECT SQUAT SWITCH PROBLEM. TRIED GEAR LEVER SEVERAL TIMES. SERVICED NOSE STRUT WITH NITROGEN IAW MM 32-21. PERFORMED CHECK…
- 15 Dec 2000
Smoke Detector, damaged
FOUND JUST AFTER TAKE OFF 'A' LOOP SMOKE DETECTOR IN FORWARD CARGO COMPARTMENT LIGHT ILLUMINATED. RETURNED TO CAK AIRPORT LIGHT EXTINGUISHED AFTER LANDING.…
- 29 Oct 2000
Skin, cracked
FOUND CRACKED EXTERIOR SKIN IN LOWER AFT DOOR JAMB CORNER OF FORWARD SERVICE DOOR. CUT OUT CRACKED SECTION, FABRICATED REPAIR DOUBLERS, SHIMS AND FILLERS. IAW…
- 21 Oct 2000
Frame, corroded
FOUND VERTICAL STABILIZER LEADING EDGE UPPER KNEE CUP HAS CORROSION. REMOVED AND REPLACED VERTICAL STABILIZER LEADING EDGE HORSESHOE FORMER IAW DC9 SRM…
- 7 Oct 2000
Longeron, corroded
FOUND CORROSION ON LEFT LONGERON NR 20 AT THE OUTBOARD MEMBER SURFACE. CORROSION WAS OUT OF LIMITS, REMOVED CORRODED SECTION. FABRICATED AND INSTALLED…
- 6 Oct 2000
Floor Panel, cracked
FOUND FLOORBOARD NR 67 TEMPORARY PATCH INSTALLED. REMOVED FLOOR PANEL NR 67, FABRICATED REPAIR SKIN. REPLACED HAT CHANNELS AND INSTALLED REPAIR SKIN.…
- 6 Oct 2000
Skin, corroded
FOUND FLOOR BOARD NR 80 CORRODED ON SKIN. REMOVED CORROSION AND FOUND 3 CRACKS. REPAIRED SKIN, REMOVED AND INSTALLED HATS, AND REINSTALLED FLOOR BOARD IAW DC9…
- 6 Oct 2000
Floorbeam, corroded
FOUND FLOOR SUPPORT BEAM AT BS 1012 RBL 24 TO LBL 24 WAS CORRODED. MECHANICALLY REMOVED CORROSION, FOUND TO BE OUT OF LIMITS. REMOVED LEFT AND RIGHT BEAM AND…
- 5 Oct 2000
Floor Panel, corroded
FOUND FLOOR BOARD NR 4695 WAS CORRODED. BLENDED OUT CORROSION, FOUND TO BE OUT OF LIMITS. REMOVED AND REPLACED HATS AND FABRICATED AND INSTALLED FLOOR PANEL…
- 5 Oct 2000
Floor Panel, corroded
FOUND FLOOR PANEL 4692 CORRODED AND HAT CHANNELS CRACKED. REMOVED FLOOR PANEL AND REMOVED CORROSION, FOUND TO BE OUT OF LIMITS. FABRICATED, TREATED, AND…
- 3 Oct 2000
Panel, corroded
FOUND PANEL 1211 AT RIGHT WING LOWER LEADING EDGE HAS AREA OF CORROSION ON OUTER SURFACE. REMOVED CORROSION AND FOUND TO BE OUT OF LIMITS, FORMED REPAIR…
- 20 Mar 2000
Connector, disconnected
NO RIGHT MAIN LANDING GEAR GREEN LIGHT FOR THE LANDING GEAR DOWN INDICATION. CORRECTIVE ACTION: CORRECTED OPEN WIRE AT RT GEAR DOWN LIMIT CONNECTOR (P1-129).
- 18 Mar 2000
Light, dislodged
EMERGENCY PATH LIGHTING IN BUSINESS CLASS IS OUT OF TRACK. CORRECTIVE ACTION: RESECURED LIGHT.
- 25 Jan 2000
Light, failed
FOUND TAIL CONE LEFT STAIR EMERGENCY LIGHT WOULD NOT ILLUMINATE. RELAMPED UNIT IAW DC9 MM 33-50.
- 23 Jan 2000
Strut, discharged
FOUND LANDING GEAR UPLATCH RELEASE OR GROUND SHIFT DID NOT WORK AND WOULD NOT RAISE. ON FINAL AT BUF (BUFFALO). GROUND SHIFT OR THE UPLATCH RELEASE WAS HEARD…
- 21 Jan 2000
Strut, discharged
FOUND AFTER TAKEOFF AIRCRAFT WOULD NOT PRESSURIZE AND GEAR WOULD NOT COME UP. RETURNED TO BMI (BLOOMINGTON-NORMAL). STEERING IN AIR WOULD TURN. INSPECTED…
- 3 Jan 2000
Engine, fod
ON CLIMB-OUT, NOISE AND VIBRATION WERE NOTED FROM NUMBER 2 ENGINE. NR 2 ENGINE SHUT DOWN, AIRCRAFT RETURNED FOR LANDING. REMOVED AND REPLACED NR 2 ENGINE AND…
- 21 Dec 1999
Glide Slope, inoperative
DURING CLIMB-OUT, NR 2 NAV BECAME INOPERATIVE AND ALL FLOURESCENT LIGHTS FLICKERED. RESEATED NR 2 NAV CONTROL PANEL IAW DC9 MM 34-32 AND TESTED LIGHTING IAW…
- 9 Oct 1999
Clamp, failed
INBOUND TO ATL LOST CABIN PRESSURIZATION AT 14,000 FT, PASSENGER OXYGEN MASKS DEPLOYED. BOTH AIR CONDITIONING PACKS QUIT AT THE SAME TIME. BOTH PACKS WERE…
- 5 Sep 1999
Rib, gouged
SCHEDULED INSPECTION AT TIMCO LAKE CITY, FL, FOUND GOUGED ON THE LEADING EDGE NR 3 SLAT RIB AT XOS 288.193. BLEND OUT GOUGED AREA, TREAT, PRIMED, AND REFINISH…
- 14 Aug 1999
Skin, corroded
DURING A ROUTINE INSPECTION AT TIMCO LAKE CITY FL, FOUND EXTERIOR FUSELAGE SKIN HAS BULGE AT BS 990 L25L. REMOVED CORROSION AT BS 976-996. FABRICATED,…
- 13 Aug 1999
Skin, corroded
DURING A ROUTINE INSPECTION AT TIMCO LAKE CITY FL, FOUND EXTERIOR FUSELAGE SKIN OF AFT CARGO DOOR AT BS 935 CORRODED. CUT OUT CORRODED AREA. FORMED, DRILLED,…
- 9 Aug 1999
Longeron, chafed
DURING SCHEDULED INSPECTION AT TIMCO, FOUND FLANGE OF LONGERON AT RT BOTTOM OF BS 1076 CHAFED. BLENDED OUT CHAFED AREA. FABRICATED AND INSTALLED EXTERNAL…
- 6 Aug 1999
Panel, corroded
DURING SCHEDULED INSPECTION AT TIMCO LAKE CITY FL, FOUND CORROSION ON INNER FLANGE LT PANEL NR 2108A. CLEANED CORROSION ON INNER FLANGE. FABRICATED, TREATED,…
- 31 Jul 1999
Fixed Vane, corroded
DURING SCHEDULED CHECK AT TIMCO LAKE CITY FL, FOUND SPOTS OF CORROSION ON UNDERSIDE OF RT WING FLAP FIXED VANE. REMOVED CORROSION. FABRICATED FILLERS AND…
- 29 Jul 1999
Web, cracked
SCHEDULED INSPECTION AT TIMCO LAKE CITY, FL, FOUND THE LEFT CUSP WEB AT BS 737-756 WITH CORROSION AND CRACKS. FABRICATED NEW CUSP WEB, TRIMMED AND DRILLED TO…
- 29 Jul 1999
Fitting, corroded
SCHEDULED INSPECTION AT TIMCO LAKE CITY, FL, FOUND THE FORWARD CABIN GALLEY AREA AT BS 149 L-18R AT CUSP LINE LOWER FRAME WEB AND ATTACH FITTING CORRODED.…
- 29 Jul 1999
Panel, corroded
DURING SCHEDULED CHECK AT TIMCO LAKE CITY FL, FOUND RT WING LOWER LEADING EDGE PANEL CORRODED. REMOVED CORROSION. FABRICATED DOUBLERS, TREATED, PRIMED AND…
- 29 Jul 1999
Fixed Vane, corroded
DURING SCHEDULED CHECK AT TIMCO LAKE CITY FL, FOUND OUTBOARD FIXED VANE ON RT WING CORRODED. FABRICATED FILLER AND DOUBLER. INSTALLED IAW DC9 SRM 57-50-1,…
- 29 Jul 1999
Floor, corroded
DURING SCHEDULED CHECK AT TIMCO LAKE CITY FL, FOUND FLOOR PANEL ON RT SIDE AT BS 280 CORRODED. FABRICATED NEW PANEL AND INSTALLED IAW DC9 SRM 51-21-0, 51-30-1.
- 29 Jul 1999
Floor, corroded
DURING SCHEDULED CHECK AT TIMCO LAKE CITY FL, FOUND FWD ENTRY FLOOR PANEL AT BS 160-200 RT CORRODED. FABRICATED NEW PANEL IAW DC9 SRM 53-20-0, 51-10-4.
- 27 Jul 1999
Floor, corroded
SCHEDULED INSPECTION AT TIMCO LAKE CITY, FL, FOUND THE FORWARD ENTRY FLOOR PANEL AT BS 180-200 CORRODED. FABRICATED FLOOR BOARD, DRILLED, DEBURRED,…
- 25 Jul 1999
Skin, corroded
SCHEDULED INSPECTION AT TIMCO LAKE CITY, FL, FOUND THE RIGHT WING LEADING EDGE PANEL NR 1219A CORRODED AND ANGLE SUPPORT CHAFFED. REMOVED CORROSION, BLEND OUT…
- 24 Jul 1999
Fitting, corroded
DURING SCHEDULED CHECK AT TIMCO LAKE CITY FL, FOUND LONGERON END FITTING AT BS 990 L-25L CORRODED. DRILLED NEW LONGERON END FITTING IAW DC9 SRM 51-10-2,…
- 23 Jul 1999
Floor, corroded
DURING A SCHEDULED INSPECTION AT TIMCO LAKE CITY, FL, FOUND FWD ENTRY RT FLOOR PANEL AT BS 200-280 CORRODED. 3 HAT CHANNELS CRACKED, ELONGATED HOLES AND…
- 22 Jul 1999
Skin, corroded
SCHEDULED INSPECTION AT TIMCO LAKE CITY, FL, FOUND THE RIGHT WING FLAP 25 AND 27 INCHES OUTBOARD OF INBOARD FLAP ACTUATOR CORRODED. REMOVED FASTENERS,…
- 21 Jul 1999
Floor, corroded
DURING A SCHEDULED INSPECTION AT TIMCO LAKE CITY, FL, FOUND FLOOR PANEL NR 4693 AT BS 180-200 CORRODED ON TOP SIDE OF PANEL AND INSULATION TORN. REMOVED…
- 21 Jul 1999
Frame, corroded
DURING A SCHEDULED INSPECTION AT TIMCO LAKE CITY, FL, FOUND CANTED FRAME AT BS 1074 CORRODED ON FWD SURFACE BELOW L-2L. REMOVED OLD WEB. FABRICATED WEB…
- 21 Jul 1999
Floor, corroded
SCHEDULED INSPECTION AT TIMCO LAKE CITY, FL, FOUND RIGHT FLOOR PANEL AT BS 160-180 CORRODED. FABRICATED FLOORBOARD PANEL, DRILLED, DEBURRED, DIMPLED,…
- 20 Jul 1999
Fitting, corroded
DURING SCHEDULED CHECK AT TIMCO LAKE CITY FL, FOUND LONGERON END FITTING CORRODED AT BS 990 L24L. OBTAINED NEW END FITTING. DRILLED AND DEBURRED IAW SRM…
- 19 Jul 1999
Floor, corroded
SCHEDULED INSPECTION AT TIMCO LAKE CITY, FL, FOUND FLOOR PANEL AT BS 200-280 LEFT CORRODED ALONG EDGE UPPER AND LOWER FLANGE. CRACKS ON END HOLES IN PANEL.…
- 18 Jul 1999
Seat Track, corroded
SCHEDULED INSPECTION AT TIMCO LAKE CITY, FL, FOUND THE FORWARD CABIN OUTBOARD SEAT TRACK AT BS 198-205 RBL-44 CORRODED. REMOVED SEAT TRACK, CUT, DRILLED,…
- 18 Jul 1999
Seat Track, corroded
SCHEDULED INSPECTION AT TIMCO LAKE CITY, FL, FOUND THE CABIN RIGHT INBOARD SEAT TRACK AT 198-206 RBL-22 CORRODED. REMOVED SEAT TRACK, LOCATED AND DRILLED,…
- 17 Jul 1999
Panel, corroded
DURING A ROUTINE INSPECTION AT TIMCO LAKE CITY FL, FOUND EXTERIOR FUSELAGE LT SIDE AT BS 237-303 HAS SPOTS OF SURFACE CORROSION AROUND WINDOW FRAME BELT. HFEC…
- 17 Jul 1999
Pan, corroded
SCHEDULED INSPECTION AT TIMCO LAKE CITY, FL, FOUND THE RIGHT SIDE AFT CARGO PIT DOOR CUT OUT CORRODED. REPAIRED THE AFT CARGO DOOR FUSELAGE CUT OUT PAN AFT…
- 27 Apr 1999
Duct, loose
TAIL COMPARTMENT TEMPERATURE HIGH LIGHT CAME ON AFTER TAKEOFF, LIGHT WENT OUT WHEN LEFT THROTTLE PULLED BACK TO IDLE. AIR RETURN. RESECURED DUCT BEFORE LEFT…
- 25 Apr 1999
Seal, worn
HI TEMPERATURE IN TAIL COMPARTMENT ANNUNCIATOR LIGHT AND MASTER CAUTION ILLUMINATED AFTER TAKEOFF. OVERWEIGHT LANDING ALSO OCCURED. REMOVED LEFT PNEUMATIC…
- 17 Jan 1999
Wire, broken
PATH LIGHTING DOES NOT ILLUMINATE FROM ROW 10 TO ROW 14. REPAIRED BROKEN WIRE AT ROW 14 PER DC-9 MM 33-50.