N865DA
1999 Boeing 777-232 standard FAA →
registration
- 1999
NTSB
- 12 Jul 2007
accident, Atlanta GA
service difficulty reports
68 reports
- 26 Mar 2025
Fire Bottle, leaking
OFAR AFT PORTABLE WATER FIRE EXTINGUISHER LEAKING. REMOVED AND REPLACED OFAR AFT PORTABLE WATER FIRE EXTINGUISHER IAW AMM 26-26-02
- 26 Mar 2025
Fire Bottle, leaking
R1 CLOSET PORTABLE WATER FIRE EXTINGUISHER LEAKING. REMOVED AND REPLACED R1 CLOSET WATER FIRE EXTINGUISHER IAW AMM 26-26-02.
- 6 Feb 2025
Battery Pack, no test
DURING SCHEDULED OPERATION CHECK OF OVERHEAD FLIGHT ATTENDANT REST AREA BACKUP LIGHTS FAILED OPERATION TEST.
- 8 Dec 2019
Rib, cracked
(AIRCRAFT 7006, L/P 1392582) OPEN HOLE HFEC INSPECTION SHOWS 7 EA CRACK INDICATIONS AT RIB ISS196 (2ND RIB O/B). 1 EA HOLE HAS CRACK APPROX. 1.25". OTHER 6…
- 20 Feb 2019
Lens, missing
SEVERAL EMERGENCY PATH LIGHTING COVERS MISSING. CORRECTIVE ACTION: INSTALLED NEW COVERS. CKS OK.
- 14 Dec 2018
Floor Support, dented
(AIRCRAFT 7006, L/P 0864004) MTC TASK - BULK CARGO STA 1944 RBL 16.5 ATTACHED FLOOR STRINGER SURFACE FOUND DENT. MTC TASK - BULK CARGO AT STA 1942 - STA…
- 14 Dec 2018
Floor Support, dented
(AIRCRAFT 7006, L/P 0864010) MTC TASK - BULK CARGO STA 1991 LBL 8.5 ATTACHED FLOOR STRINGER SURFACE FOUND DENT. MTC TASK - BULK CARGO AT STA 1990 - STA 1993…
- 14 Dec 2018
Floor Support, dented
(AIRCRAFT 7006, L/P 0864018) MTC TASK - BULK CARGO STA 1944 RBL 16.5 ATTACHED FLOOR STRINGER SURFACE FOUND DENT. MTC TASK - BULK CARGO AT STA 1942 - STA…
- 14 Dec 2018
Floor Support, dented
(AIRCRAFT 7006, L/P 0864025) MTC TASK - BULK CARGO STA 1895 RB 16.5 ATTACHED FLOOR STRINGER SURFACE FOUND DENT. MTC TASK - BULK CARGO AT STA 1895 RBL 16.5…
- 27 Oct 2018
Light, damaged
(AIRCRAFT 7006, L/P 5115673) UNDER SEAT EMERGENCY LIGHT AT 51D DAMAGED. REMOVED AND REPLACED FLOOR PROXIMITY LIGHT ASSY. PER B777 AMM 33-51-05.
- 11 Oct 2018
Connector, unsecure
EMERGENCY FLOOR LIGHTING DAMAGED OR INOPERATIVE / LOCATIONS:38D. SECURED LIGHT CONNECTION.
- 9 Oct 2018
Powerpack, inoperative
(AIRCRAFT 7006, L/P 4361533) EMERGENCY LIGHTS INOP ON SEVICE CHECK ZONE 3. REMOVED AND REPLACED POWER PACK AND BATTERY IAW WDM 33-51-14 AT LOCATION M33404.
- 27 Jan 2018
Oxygen Mask, unwanted deploy
OXYGEN PANEL MASK DEPLOYED. DOOR FELL OPEN BUT GENERATOR DID NOT ACTIVATED. INSPECTED PASSENGER OXYGEN SYSTEM NO DEFECTS. CHECKED AFFECTED MASK COMPARTMENT…
- 8 Jan 2018
Charger, inoperative
EMERGENCY LIGHTS INOP AT3L DOOR. NEED BATTERY PACKS AT LOCATION M33406 AND 33405. FOUND BAD BATTERY CHARGER, REPLACED. ALSO REPLACED 4 EACH BATTERIES. ALL…
- 10 Dec 2017
None, none
SHIP 7006 2L DOOR WILL NOT CLOSE PROPERLY. CORRECTIVE ACTION: RE-CYCLED DOOR SEVERAL TIMES. OPS CK GOOD (4016484).
- 22 Nov 2017
Bearing, out of position
ON THE LEFT WING, THE NUMBER 3 FLAP TRACK, FLAP MOTOR CARRIAGE MOUNT, UPPER INBOARD ATTACH BOLT IS RUSTY AND THE BEARING HAS PULLED OUT OF STRUCTURE.…
- 28 Oct 2017
Door, out of sequence
2L DOOR WILL NOT CLOSE. FOUND DOOR 2L OUT OF SEQUENCE. REMOVED ACCESS COVER TO PUT INSIDE HANDLE IN OPEN POSITION. CLOSED AND OPENED DOOR IAW AMM 52-00 OPS…
- 1 Oct 2017
Wire, shorted
DOING SERVICE CHECK FOUND EMERGENCY LIGHTS INOP SEATS 29 DEF TO 43 DEF AND EXIT IDENTIFIERS INOP AT AISLES DOOR 3. REPAIRED SHORTED WIRES ABOVE DOOR 3 LEFT TO…
- 29 Mar 2017
Seat Track, cracked
DURNING CRV, FOUND SEAT 53JHG LOOSE AND THE TRACK CRACKED. THE DAMAGED SEAT TRACK IS AT BS 1860 LBL 108. RELACED THE SEAT TRACK SECTION IAW DRAWING 151W7285,…
- 18 Mar 2017
Lens, missing
EMERGENCY LENS MISSING AT 3L/R CROSS AISLE. INSTALLED NEW EMER LIGHT LENS PER AMM 33-51.
- 3 Mar 2017
Battery, inoperative
DURING A SERVICE CHECK, FOUND THE R1 DOOR EPAS GREEN LIGHT INOPERATIVE. REPLACED EPAS 9 VOLT BACK-UP BATTERY IAW AMM 52-11.
- 6 Feb 2017
Lens, damaged
EMERGENCY EXIT COVER DIFFUSER LENS DAMAGED SEAT 55D. THE LENS WAS REPLACED. OPS CHECKED NORMAL IAW CMM 25-27-89.
- 7 Nov 2016
Sign, out of position
EXIT SIGN ABOVE DOOR 2L OFF OF BRACKET. REINSTALLED EXIT SIGN COVER. CONDITION CHECK NORMAL.
- 18 Sep 2015
Bulb, failed
DURING SERVICE CHECK, FOUND DOOR 3L HORIZONTAL EXIT SIGN IS DIM. RELAMPED 8 LIGHT BULBS.
- 2 Apr 2015
Power Supply, inoperative
EMERGENCY AISLE LIGHTS INOPERATIVE BETWEEN SEATS 30A-J TO 41A-J. FOUND EMERGENCY LIGHT POWER SUPPLY AT DOOR 3R INOPERATIVE. R & R POWER SUPPLY AT DOOR 3R IAW…
- 17 Dec 2013
Fuse, failed
R2 DOOR EMERGENCY EXIT SIGN INOPERATIVE. REPLACED POWER SUPPLY FUSE. CHECKED NORMAL IAW AMM 33-51. OK FOR SERVICE.
- 7 Dec 2013
Lamp, wrong part
EMERGENCY PATH LIGHTS INOPERATIVE. FOUND INCORECT LAMPS. INSTALLED CORRECT LAMPS, REPLACED FUSE. OPS CHECKED GOOD.
- 21 Nov 2013
Battery Pack, inoperative
FLOOR EMERGENCY ESCAPE LIGHT INOPERATIVE ROW 10-14 ABCD. REMOVED AND REPLACED BATTERY PACK AND FUSE IN POWER SUPPLY IAW MM 33-51-06 OPS CHECKED GOOD. OK FOR…
- 18 Jan 2013
Battery, inoperative
DURING SERVICE CK, FOUND 4R DOOR EPAS BATTERY INOPERATIVE. C/A R & R (2) 9V BATTERIES FOR 4R EPAS BACKUP BATTERIES IAW B777 52-11. OPS CHECK GOOD AT THIS TIME.
- 22 Dec 2012
Fuse, inoperative
ROWS 31 THRU 41 SEAT MOUNTED PROXIMITY LIGHTS INOP. POWER SUPPLY M33404, FUSE 4 AND FUSE 3 TESTED BAD WIP(801167). REPLACED FUSE, CHECKED GOOD REF 33-51-00.
- 2 Jan 2012
Skin, dented
NR 4 FLAP UPPER SURFACE DENTED. REPAIRED IAW SRM 57-53-01, AND SRM 51-70-04.
- 11 Nov 2011
Power Supply, inoperative
DURING A MAINTENANCE VISIT, THE EMERGENCY EXIT SIGN AT DOOR 3R WAS FOUND TO BE INOPERATIVE. MAINTENANCE REPLACED THE POWER SUPPLY. SYSTEM OPERATION WAS NORMAL…
- 2 Oct 2011
Fuse, broken
DURING A MAINTENANCE VISIT, DOOR 2R SLIDE LIGHT AND FORWARD ZONE 2 EMERGENCY FLOOR PROX LIGHT WERE FOUND TO BE INOPERATIVE. MAINTENANCE FOUND THE FUSE 2…
- 30 Apr 2011
Socket, shorted
DURING A MAINTENANCE VISIT, THE EMERGENCY TRACK LIGHTS ALONG BUSINESS ELITE SEATS ROW 10-14 ON THE LEFT AND RIGHT AISLE WERE FOUND TO BE INOPERATIVE.…
- 23 Jan 2010
Battery Pack, discharged
BATTERY PACK FAILS CAPACITY TEST. REPLACED 3 BATTERY PACKS FOR SEAT ROWS 10-41 OPS NOW CK NML.
- 17 Jan 2010
Connector, broken
EMERGENCY LIGHT AT SEAT31F INOP. REPAIRED BROKEN CONNECTOR OP CK GOOD.
- 8 Jan 2010
Chiller, inoperative
IR - MIDGALLEY AFT CHILLER INOPERATIVE. OVERHEAT LT ON WITH ELECTRICAL ODOR. C/BS PULLED AND COLLARED.
- 18 Oct 2009
Valve, malfunctioned
RTB DUE TO LT ENG SPAR VLV MSG. RESET MSG, CLEARED MSG LT ENG STARTED NORMAL. ETOPS CATEGORY 'F': ANY OTHER EVENT DETRIMENTAL TO ETOPS.
- 14 Sep 2009
Shroud, damaged
THE 1ST STG LPT OUTER SHROUD WAS BORESCOPED PER OPN 52140. DAMAGE WAS FOUND IN THE OUTER SHROUD. ETOPS CATEGORY 'F': ANY OTHER EVENT DETRIMENTAL TO ETOPS.
- 17 Jun 2009
Pressure Switch, failed
RTB DUE TO LT ENG FUEL FILTER WARN EICAS MSG/C FWD TO MCO PLACARD PER MEL 73-34-01A. R & R FUEL FILTER DIFFERENTIAL PRESSURE SWITCH IAW AMM. OPS CHECK OK.…
- 1 Feb 2008
Skin, damaged
FUSELAGE SKIN HAD LIGHTNING STRIKE DAMAGE AT STA 424 AND STA 455 AT S-10L. ALSO, THE S-10L STRINGER SUSTAINED TOOLING DAMAGE DURING ACCOMPLISHMENT OF THE SKIN…
- 30 Oct 2007
Light, malfunctioned
EMERGENCY LIGHTS IN CABIN ILLUMINATED INTERMITTENTLY DURING CRUISE. PERFORM EMERGENCY LIGHTS DAILY OPERATIONAL TEST AND EMERGENCY LIGHTS OPERATIONAL TEST WITH…
- 25 Jun 2007
None, none
WINDSHEAR MSG DISPLAYED. FWD WINDSHEAR TO MCO PER MEL 34-43-01D. NO FAULT HIST IN MAT. RAN WXR TEST NO FAULTS. MCO AND PLACARD REPLACED.
- 11 Feb 2007
Electronic Unit, inoperative
WORK LIGHTS INOPERATIVE AT 3L/3R. OEU M23406 AT 3R DOOR FAILED ON CABIN ALL TEST. FOUND OEU SHOWS EVIDENCE OF BURN MARK. REMOVED AND REPLACED OEU. COULD NOT…
- 6 Feb 2007
Unknown, odor
FLT ATTN OBL REPORTS ODOR AT FWD B/E CABIN LEFT SIDE. POSS BURNING SMELL. NO SMOKE OR FIRE NOTED. FLT ATTN OBL COULD NOT IDENTIFY SMELL OR SOURCE. OBL DID NOT…
- 24 Oct 2006
Weu, malfunctioned
ON T/O PWR STABILIZER WARNING SOUNDED - T/O TRIM WAS NOT IN THE GREEN BAND. TRIM WAS IN THE GREEN BAND AT PUSH BACK. AWABS TRIM SETTING 2.5. CHECKED MAT FOR…
- 11 Feb 2006
Valve, leaking
AFTER T/O, LEFT ENG BLEED OFF EICAS MESSAGE. A/C RETURN TO ATL. MTC REPLACED HPSOV AND PNEU PRESSURE LINE FROM BRACKET DISCO, HPSOV NEED LEAK CHECK AND OP…
- 22 Jan 2006
Chiller, odor
ON PRE-FLIGHT, F/A REPORTED BURNING SMELL IN AFT GALLEY. FAULT LIGHT ON CHILLER. REPLACED CHILLER.
- 11 Jan 2006
Gssr, failed
UNABLE TO PWR GROUND SERVICE BUSS CABIN LIGHTS OUT/GALLEY PWROUT/ENT SYSTEM OUT. NO LAND 3 IN FDE WAS ABLE TO RESTORE USING APU PWR HOWEVER COULD RESTORE BACK…
- 12 Nov 2005
Insulation, damaged
THRUST REVERSER INSULATION BLANKETS WERE FOUND DAMAGED. INSPECTED AND REPAIRED PER ER/A 451632-14AD REF AD 2005-07-24.
- 17 Aug 2005
A/C Pack, odor
A/C HAS STRONG OIL SMELL. RAN PACKS FOR 1 HOUR. CHECKED A/C SYSTEMS. NTF.
- 12 Aug 2005
Odor, detected
CHEMICAL/MUSTY SMELL 4 TIMES USUALLY WITH PWR REDUCTION ALSO NOTED IN AFT CABIN, CHKD PER FIM TASK 21-00-00-810-808. CHKD L ENG BLEED AIR FOR OIL CONTAM. CHKD…
- 12 Aug 2005
Converter, failed
STRONG OIL SMELL DURING FLT WORSE IN CLB/DESCENT AND PWR CHANGES. SUSPECT FROM PACK L/R. OVERWHELMING ODOR IN C/P ON DESCENT IRRITATED EYES. CHECKED EXH OF LT…
- 15 Jun 2005
Fan, failed
RECIRC FAN STAUS MSG STRONG ELECTRICAL ODOR. REPLACED FAN.
- 4 Dec 2004
Case, cracked
ELEC GEN OFF RIGHT EICAS MESSAGE IN FLIGHT WITH GEN DRIVE RIGHT EICAS MESSAGE. FOUND RT IDG CASE SHATTERED AND ZERO OIL. REPLACED IDG AND RAN ENG PER PFHB…
- 19 Nov 2003
Fuse, blown
EMERGENCY CEILING LIGHT AT SEAT ROW 38 IS OUT. FOUND FUSE BLOWN IN BATTERY PACK. REPLACED FUSE EMERGENCY LIGHTS CHECKS GOOD.
- 25 Oct 2003
Slide, unserviceable
AT DEPARTURE L-2 DOOR SLIDE CAME OFF THE DOOR. REPLACED L2 DOOR SLIDE ASSEMBLY.
- 29 Aug 2003
Fan, failed
RT LOWER RECIRC FAN TRIPPED IN FLT HEAVY ELECTRICAL SMELL DETECTED PRIOR TO FAILURE. REMOVED AND REPLACED RECIRC FAN. SYSTEM OPS CHECK NORMAL.
- 28 Mar 2003
Coffeemaker, sparks
COFFEEMAKER AT 205 SPARKING TURNED OFF PWR PULLED C/B. REPLACED COFFEEMAKER.
- 27 Jan 2003
Idg, inoperative
RT IDG TRIPPED OFF SHORTLY AFTER TAKEOFF. ELECT SMELL IN CABIN. TRIED ONE RESET NO HELP. 0634/28JAN/ATL/ 456509 - PASSING 10000 FEET AFTER TAKE OFF ELEC GEN…
- 12 Nov 2002
Line, leaking
OIL QUANTITY RT ENGINE DROPPED TO 1 DURING FLIGHT, ALL OTHER INDICATIONS WERE NORMAL. REPLACED OIL BEARING SUPPLY LINE.
- 6 Sep 2002
Engine, damaged
BOTH ENGINES CHANGED DUE TO FAILED BOROSCOPE. DUST CAP INSPECTED
- 21 May 2002
Coffeemaker, sparks
GALLEY 412 DURING FLIGHT, F/A OBSERVED SPARKS FROM COFFEEMAKER NR 2. DEPOWERED ALL 3 C/BS TO ALL 3 COFFEEMAKERS. REMOVED ALL COFFEEMAKERS OUT OF AFT GALLEY…
- 18 Mar 2002
Connector, burned
ROCKWELL FOUND BURNT CONNECTOR AT VIDEO SCREEN SEAT 30G. DISCONNECTED SDU TO AVU CABLE FWD TO MCO.
- 3 Mar 2002
Power Supply, faulty
STRONG BURNING SMELL IN CABIN, INFLIGHT. EMERGENCY DECLARED INTO ATL. REMOVED AND REPLACED POWER SUPPLY. UNIT SENT TO MANUFACTURER FOR ANALYSIS. SUSPECT…
- 6 Feb 2001
Structure, vibration
MODERATE VIBRATION REPORTED BY F/A ON T/O LOUD NOISE AT 2L/2R DOORS F/O CONFIRMED AT APPROX 10K FEET. STAB WAS 4.5 FOR T/O BUT REQUIRED SUBSTANTIAL FORCE FOR…
- 11 Sep 2000
Transceiver, malfunctioned
STATUS MSG WXR SYS AND NO WXR AVAILABLE. REPLACED TRANSCEIVER, OPS CHECK NORMAL.
- 29 Aug 2000
Apu, malfunctioned
LT ENG GEN/IDG ON MCO-APU S/D GOING THROUGH 19K APU RE-START OK BUT CREW LOST CONFIDENCE IN THE APU FOR THE CROSSING. AIR TURNBACK, ELEC GEN OFF L EICAS…