N864AL
Zipline International INC P2 ZIP FAA →
registration
earlier registrations
2 past records
- 2004
- 2003
service difficulty reports
17 reports
- 11 Apr 2019
Fire Detector, defective
DURING CRUISE FLIGHT #2 ENGINE FIRE WARNING LIGHT ILLUMINATED WITH AUDIO. NO INDICATION OF SMOKE PRESENT , ALL INSTRUMENTS WERE INDICATING NORMAL. RTB TO GNO.…
- 10 Apr 2019
Connector, dirty
DURING CRUISE PORTION OF FLIGHT, #2 ENGINE FIRE WARNING LIGHT ILLUMINATED. NO FURTHER INDICATIONS OF FIRE NOTED, CREW ELECTED TO ABORT MISSION AND RTB.…
- 5 May 2015
Smoke Detector, failed
AFTER TAKEOFF, CLIMBING TO 1750 FEET AGL, BAGGAGE COMPARTMENT SMOKE DETECTOR WARNING LIGHT ILLUMINATED. NO INDICATION OF SMOKE WAS PRESENT, ACFT TURNED AROUND…
- 15 Nov 2014
Unknown, smoke
UPON LANDING FROM A HOVER, COCKPIT FILLED WITH SMOKE & AFT BAG FIRE WARNING LIGHT ILLUMINATED. ACFT LANDED & SHUTDOWN, INSPECTED BAGGAGE COMPARTMENT & FOUND…
- 14 Nov 2014
Duct, leaking
AFTER LANDING, AFT BAG FIRE LIGHT ILLUMINATED. LIGHT EXTINGUISHED WHEN BLEED AIR & BLOWER SWITCHES WERE TURNED OFF. FOUND OIL ON HEATER DISTRIBUTION BOX &…
- 9 Nov 2014
Connector, dirty
DURING ACFT RUN UP AFT BAGGAGE COMPARTMENT SMOKE LIGHT ILLUMINATED. CLEANED SMOKE DETECTOR CONNECTOR OPERATIONS CHECKED SYS, SYS CHECKED GOOD.
- 21 May 2013
Blade, split
DURING 500 HR ROUTINE INSPECTION, FOUND BLADE SPAR SPLINTERED ON "B" SIDE AT APPROXIMATE STATION 10.5
- 9 Oct 2012
Housing, corroded
MAIN GEARBOX HOUSING HAS CORROSION.
- 22 Jun 2011
Oil System, overheated
SHORTLY AFTER TAKEOFF, NOTICED THE NR 2 ENGINE OIL TEMP HAD CLIMBED ABOVE THE RED LINE ALL THE WAY TO 118 C. IMMEDIATELY REDUCED THE ENGINE TO IDLE, AS IT…
- 26 May 2010
Angle, cracked
UPON MAJOR INSPECTION OF AFT SPAR AREA, FOUND CRACK IN AFT EDGE OF SPAR THROUGH HIGH LOC HOLE, .500 IN. LONG AT WL 111, STA. 103.4.
- 22 Mar 2005
Chip Detector, contaminated
DURING FLIGHT THE NR 1 ENGINE ILLUMINATED TEN MINUTES AFTER DEPARTURE. THE NR 1 ENGINE WAS PLACED IN GROUND IDLE IAW EMERGENCY CHECK LIST AND THE FLIGHT…
- 30 Oct 2004
Pylon, cracked
ON A DAILY SERVICE CHECK, FOUND 4 INCH CRACK ON LT SIDE FOR VERTICAL PYLON, UPPER FORWARD CORNER OF THE INSPECTION PANEL AT VS STATION 123.071. MAINTENANCE…
- 30 Oct 2004
Structure, cracked
ON DAILY SERVICE CHECK FOUND 4 INCH CRACK ON LT SIDE FOR VERTICAL PYLON, UPPER FORWARD CORNER OF THE INSPECTION PANEL AT VS STATION 123.071. MAINTENANCE…
- 23 Sep 2004
Transmission, making metal
WHILE HOVERING TO REPOSITION FOR TAKEOFF MAIN GEAR BOX CHIP LIGHT ILLUMINATED. RETURNED TO PARKING, NOTIFIED CUSTOMER, BASE MANAGER AND MAINTENANCE.…
- 21 Jul 2004
Warning Light, illuminated
DURING TAKEOFF, INTERMEDIATE/TAIL ROTOR GEAR BOX LIGHT CAME ON DURING TAKEOFF, CIRCUIT BREAKER WAS PULLED, LIGHT WENT OUT, RESET CIRCUIT BREAKER, LIGHT CAME…
- 7 Jul 2004
Bearing, spalled
TRANSMISSION DISASSEMBLED FOR METAL CONTAMINATION, FOUND ROLLER BEARING BREAKING DOWN. REMOVED AND REPLACED BEARING.
- 4 Jul 2004
Gearbox, making metal
AT A HOVER READY FOR TAKEOFF, AFTER INITIAL RUN UP AND PREPARING FOR TAKEOFF MAIN GEAR BOX LIGHT CAME ON. MAINTENANCE DISCOVERED METAL CHIP CONTAMINATION ON…