- 30 May 2026
Bracket, loose
CREW REPORTS FWD ENTRY DOOR GIRT BAR BRACKET LOOSE. TIGHTENED FWD ENTRY DOOR GIRT BAR BRACKET IAW SIP.
- 21 Apr 2026
Battery Pack, inoperative
SEVERAL EMERGENCY LIGHTS INOP BY FWD SERVICE DOOR. REMOVED AND REPLACED FWD EMERGENCY LIGHTS BATTERY PACK FOR FWD SERVICE DOOR PER AMM 33-51-06
- 28 Mar 2026
Cover, missing
THE CEILING EMERGENCY EXIT SIGN COVER IS MISSING<[01] INSTALLED LENS PER CMM 33-24-03
- 26 Feb 2026
Unknown, fumes
FUMES IN COCKPIT AT TAXI THROUGH FL18.0; BOTH CLIMB AND DESCENT. RAN APU AND BOTH MOTORS FOR 5 MINUTES COULD NOT DUPLICATE PER FIM TASK 21-00 TASK 806
- 7 Dec 2025
Elec Connector, loose
SIDEWALL LIGHTS ROW 15 -21 AIRCRAFT RIGHT INOPERATIVE. ROW 15 OVERWING EXIT IS WHERE POWER BREAK-IN IS LOCATED. SUSPECT THIS LIGHT ASSEMBLY OR LOOSE…
- 21 Nov 2025
Slide, out of adjust
FWD ENTRY DOOR SLIDE PARTIALLY FELL OUT OF COVER<[01] REPOSITIONED SLIDE IN COVER REF AMM 25-66-01 AND MT 725-61-06 REM/INST
- 6 Nov 2025
Fire Warning, inoperative
ENG FIRE WARNING CAPT SIDE WONT CANCEL WARNING. FIRE WARNING CUTOUT WORKS OK ON FIRE CONTROL PANEL<[01] 05 - OK TO CONTINUE PER [MEL 26-10-02;BELL CUTOUT…
- 6 Jul 2024
Light, inoperative
L1 EXTERIOR EMERGENCY LIGHT INOP.<[01] R+R BROKEN BULB CONTACT IN L1 DOOR EXTERIOR EMERGENCY EXIT LIGHT ASSY PER CMM 33-51-04. OPS GOOD.
- 28 Jun 2024
Flashlight, inoperative
FORWARD GALLEY JUMPSEAT FLASH LIGHT INOP<[01] FWD GALLEY JUMPSEAT FLASH LIGHT <BR>REPOSITIONED & SECURED; OPS CHECKED GOOD PER AMM 25-64-00
- 12 Jun 2024
Terminal, dirty
EXTERIOR EMERGENCY LIGHT INOP AFT OF L1<[01] CLEANED LIGHT BULB TERMINALS FOR EXTERIOR EMERGENCY LIGHT AFT OF L1 DOOR. OPS CHECK GOOD REF. B737 AMM 33-51-00
- 6 Jun 2024
Battery Pack, inoperative
EMERGENCY BATTERY CHARGER FOR THE AFT R/H CABIN LIGHTS WILL NOT CHARGE.<[01] REMOVED AND REPLACED EMERGENCY BATTERY AND CHARGER IAW B737 AMM 33-51-06;[02]…
- 6 Jun 2024
Fitting, cracked
RH OUTBD FUSELAGE DRAIN AT STA 1016 PLUS 3 IS CRACKED.<[01] REMOVED AND REINSTALLED DRAIN FITTING IAW B737-800 AND BAC DWG 148A3340 REV: -;[02] VERIFIED…
- 5 Jun 2024
Seal, cracked
LEFT HAND UPPER STABILIZER SLIDING SEAL WORN/ CRACKED. CRACKED / WORN AT FORWARD LOWER MOUNT<[01] REMOVED AND REPLACED L/H HORIZONTAL UPPER SLIDING SEAL IAW…
- 5 Jun 2024
Seal, cracked
RIGHT HAND STABILIZER UPPER SLIDING SEAL CRACKED/ WORN. CRACKED AT LOWER AFT MOUNT WORN AT FORWARD LOWER.<[01] REMOVED AND REPLACED R/H HORIZONTAL UPPER…
- 30 May 2024
Cover, cracked
RIGHT HORIZONTAL STAB. INBOARD ELEVATOR LEADING EDGE HINGE COVER 344GB HAS FASTENERS PULLED THROUGH IT<[01] 04 - REPAIRED PER [SRM 55-20-01-2R-4-B00929…
- 18 May 2024
Web, cracked
#1 INBD FAN COWL HAS CRACKED WEB NEXT TO PANEL 414AR.<[01] 03 - SERVICED STRUT (X-DIMENSION CHECK REQUIRED) PER [SRM 51-40-02-0G-0-B00069 (GENERAL - FASTENER…
- 15 May 2024
Floorbeam, corroded
FLOOR STRUCTURE FLOOR BEAM AT MOUNT FITTING BS 947 RBL 50 HAS A SMALL AREA OF CORROSION AT MOUNT FITTING BASE<[01] REMOVED CORROSION ORIG. .180; MATERIAL LOSS…
- 14 May 2024
Support Beam, worn
L/H WING TRAILING EDGE; DEFLECTION SUPPORT BEAM HAS WEAR MARKS AT THE TAB ATTACHED TO THE UPPER TRAILING EDGE PANEL.<[01] REMOVED DAMAGE ON LH WING INBD FIXED…
- 14 May 2024
Floorbeam, corroded
FWD WET AREA FLOOR BEAM AT STA 328 AND RBL 45.50 HAS SIGNS OF CORROSION.<[01] REPAIRED IAW SRM 53-10-51-2R-7-B00540 (REPAIR 7 - SECTION 41 - DAMAGE ON THE…
- 14 May 2024
Floor Support, corroded
FLOOR SUPPORT STRUCTURE AT BS 953 BL 24 LEFT HAS A SPOT OF CORROSION AT FASTENER LOCATION. AS MARKED.<[01] REMOVED CORROSION FROM AREA; ORIGINAL THICKNESS WAS…
- 14 May 2024
Attach Angle, cracked
L/H WING TRAILING EDGE; 1 EACH ANGLE CRACKED AT THE I/B SIDE OF THE DEFLECTION SUPPORT BEAM ( APPROX WS 278.5)<[01] REMOVED AND REPLACED L/H WING TRAILING…
- 14 May 2024
Attach Angle, cracked
L/H WING TRAILING EDGE; ATTACH ANGLE HAS 1 EACH CRACK INDICATION APPROX. WS 268.50 ( APPROX. 10' INCHES FROM THE DEFLECTION SUPPORT BEAM)<[01] REMOVED AND…
- 10 May 2024
Floor Panel, delaminated
(DISCREPANCY RACK) AFT CABIN WET AREA FLOOR PANEL 241ABF DELAM (DOT N199)<[01] 02 - INSPECTED PER [SRM 53-00-50-2R-1-B00276 (REPAIR 1 - REPAIR OF DAMAGE TO…
- 8 May 2024
Lamp, inoperative
R1 DOOR EMERGENCY LIGHT STRIP HAS BURNT OUT BULB<[01] RE-LAMPED EMERGENCY LIGHTS IAW B737 AMM 33-51-01;[02] VERIFIED RE-LAMPED EMERGENCY LIGHTS IAW B737 AMM…
- 20 Feb 2024
Flashlight, out of position
AFT GALLEY EMERGENCY FLASHLIGHT INOP<[01] RESEATED FLASHLIGHT AND TEST NORMAL PER 25-64-00
- 31 Aug 2023
Light, inoperative
LH ENTRY DOOR EMERGENCY LIGHT INOP.<[01] REMOVED AND REPLACED FORWARD CABIN ENTRY DOOR EMERGENCY LIGHT POWER SUPPLY REF AMM 33-51-06. OPERATIONAL CHECK GOOD.
- 27 Jul 2023
Battery, inoperative
FWD F/A EMER FLASH LIGHT INOP<[01] REPLACED FWD F/A BATTERY OF FLASHLIGHT; OPS CK GOOD REF MM 25-64-00
- 6 Jun 2023
Sign, out of adjust
OVERHEAD EMERGENCY EXIT SIGN FELL OFF.<[01] RESECURED OVERHEAD EMERGENCY EXIT SIGN LENS AT OVERWING PER M/M 33-51-03.
- 31 May 2023
Battery, inoperative
1 AFT F/A FLASHLIGHT NOT TESTING PROPERLY<[01] R&R?D F/A FLASHLIGHT BATTERY IN AFT INBD LOCATION PER AMM 25-64-00.
- 22 Mar 2023
Lens, out of position
PASSENGER CABIN R/H AFT EMERGENCY EXIT DOOR WINDOW LED LIGHT ASSY. INSTALLED UPSIDE DOWN.<[01] INSTALLED PASSENGER CABIN R/H AFT EMERGENCY EXIT DOOR WINDOW…
- 2 Mar 2023
Panel, cracked
LEFT PANEL BREAK ASSY AT STA 540 CRACKED<[01] R & R L/H BREAK PANEL ASSY AT STA 540 IAW SRM 51-40-02
- 2 Mar 2023
Panel, cracked
RIGHT PANEL BREAK ASSEMBLY @ STATION 540 CRACKED<[01] R & R RIGHT PANEL BRAKE ASSY AT STA 540 IAW SRM 51-40-02
- 16 Nov 2022
Battery, no test
AFT LT O/B EMERGENCY FLASHLIGHT TEST FAILED. R & R BATTERY OF AFT LT OTBD FLASHLIGHT IAW AMM 25-64-00. OPS CHECKED GOOD.
- 10 Nov 2022
Battery, inoperative
FWD GALLEY INBOARD FLASHLIGHT INOP. NEW FLIGHT CREW SAYS FLASHLIGHT IS WORKING. R&R BATTERY IN INBOARD EMERGENCY FLASHLIGHT IAW MM 25-64-00. OPS CHECKS GOOD.…
- 2 Nov 2022
Slide, out of adjust
FORWARD ENTRY DOOR ESCAPE SLIDE HANGING OUT OF BOTTOM OF DOOR / [01] RE-ADJUSTED FORWARD ENTRY DOOR SLIDE PER AMM 25-66-00. OPS NORMAL
- 13 Oct 2022
None, faulty
SELECTED FLAPS 30 DEG FROM 15 DEG ON APPROACH. FLAPS MOVED SYMMETRICALLY TO ABOUT 20 DEG AND STOPPED. / [01] FOUND FLT CONT TE FLAP/SKEW SENSOR & IND L CB…
- 27 Sep 2022
Slide, detached
FWD SERVICE DOOR SLIDE APPEARS TO BE HANGING TOO LOW / [01] PERFORMED ESCAPE SLIDE INSPECTION CHECK PER AMM 25-66-01 DOOR OPERATES NORMALLY WITHOUT SLIDE…
- 28 Aug 2022
Megaphone, missing
VOLUME KNOB MISSING AFT MEGAPHONE / [01] R&R AFT MEGAPHONE PER MM 25-64-00.<BR>EXP JUL 2023
- 26 Apr 2021
Light, inoperative
ROW 1 ABC AND DEF FLOOR LUM PHOTO LIGHT NOT WORKING / R&R FLOOR PROXIMITY LIGHT PHOTOLUMINESCENT STRIPS AT ROWS 1 ABC AND 1 DEF; REF AMM TASK 33-51-15-400-802
- 4 Mar 2021
Flashlight, inoperative
FORWARD FA JUMPSEAT FLASHILIGHT INOP RESET FLASH LIGHT AND INSTALLED SECURITY SEAL PER AMM 25.64.00.
- 8 Feb 2019
Battery, discharged
AFT OUTBOARD FIGHT ATTENDANT FLASHLIGHT FAILED TO TEST. R&R BATTERY PER MM.
- 24 Oct 2018
Slide, low pressure
L1 DOOR ESCAPE SLIDE INDICATED RED, LOW PRESSURE. R&R SLIDE PER MT.