28 reports
- 16 Jul 2014
Cover, wrong part
CREW REPORTS ARROW ON RT EMER EXIT COVER FOR OVERWING EXIT IS POINTING WRONG WAY. R & R RT EMER OVERWING EXIT LIGHT COVER IAW AMM 33-51-13.
- 7 Jul 2014
Light, inoperative
PAX DOOR LOWER EMERGENCY LIGHT INOPERATIVE. REPLACED EMERGENCY LIGHT ASSEMBLY IAW AMM 33-51-19. OPS TESTED OK.
- 12 Aug 2013
Light, inoperative
MOST FORWARD CEILING EMERGENCY FLOOD LIGHT INOPERATIVE.
- 6 Aug 2013
Recorder, no test
CVR WILL NOT TEST. REPLACED CVR IAW AMM 23-71-01. OPS TESTED GOOD.
- 12 Jul 2013
Recorder, no test
CVR WILL NOT TEST.
- 10 Jan 2013
Life Vest, unserviceable
CAPTAINS LIFE VEST HAS A TEAR IN BAG. REMOVED AND REPLACED CAPTAINS LIFE VEST IAW AMM 25-61-03.
- 26 Nov 2012
Hinge, worn
AIRCRAFT IN HEAVY CHECK FOUND PASSENGER DOOR HINGE WORN, DURING RELIABILITY CHECKS. REMOVED AND REPLACED PASSENGER DOOR HINGE IAW CRJ 200 SRM 52-10-31.
- 26 Nov 2012
Floorbeam, corroded
FLOORBEAM CAP AT LBL 9 IS CORRODED BETWEEN FS 560 AND FS 621. REPAIRED IAW BOMBARDIER REO 601R-53-61-3780.
- 26 Nov 2012
Floorbeam, corroded
FLOORBEAM CAP AT LBL 27 IN CARGO AREA IS CORRODED BETWEEN FS 560 AND FS 621. REPAIRED IAW BOMBARDIER REO 601R-53-61-3778.
- 26 Nov 2012
Seat Track, corroded
NR 2 RIGHT SEAT TRACK CORRODED. REPAIRED IAW AMM 53-01-11.
- 26 Nov 2012
Seat Track, corroded
NR 3 RIGHT SEAT TRACK CORRODED. REPAIRED IAW AMM 53-01-11.
- 26 Nov 2012
Seat Track, corroded
NR 4 RIGHT SEAT TRACK CORRODED. REPAIRED IAW AMM 53-01-11.
- 26 Nov 2012
Seat Track, corroded
NR 5 RIGHT SEAT TRACK CORRODED. REPAIRED IAW AMM 53-01-11.
- 26 Nov 2012
Flap, bent
LEFT INBOARD FLAP TRAILING EDGE BENT. REPAIRED IAW SRM 57-52-00.
- 25 Nov 2012
Battery Pack, discharged
GALLEY EMERGENCY LIGHT INOPERABLE NEXT TO SERVICE DOOR. REMOVED AND REPLACED BATTERY PACK IAW CRJ 200 AMM 33-51-04. OPS CHECK BATTERY PACK IAW CRJ 200 AMM…
- 10 Dec 2011
Warning System, activated
DIVERTED DUE TO RT ENG OIL PRESSURE WARNING MSG. CREW SHUT DOWN NR 2 ENG AND HAD MINIMAL SMOKE IN THE CABIN. CREW DECLARED AN EMERGENCY AND LANDED SAFELY.…
- 16 Jul 2011
Control Unit, malfunctioned
AIR RETURN STAB CHANNEL 1 INOP SWAPPED FROM 8541 TO 8808. REMOVED AND REPLACED THE MOTOR CONTROL UNIT AND ACTUATOR IAW AMM 27-40-00.
- 2 Jul 2011
Indication Sys, malfunctioned
ON CLIMBOUT FUEL IMBALANCE MESSAGE. MADE IT TO 1100 LBS. PER QRH SUSPECT FUEL LEAK. A/C DIVERTED INTO BOS FROM JFK - YHZ ROUTE. MAINTENANCE DEFERRED EICAS…
- 29 Mar 2011
Bulkhead, cracked
CRACK INDICATION AT LBL 18 CRACK IS 1.0625 INCH LONG. CRACK INDICATION AT RBL 18 CRACK IS .8125 INCH LONG. CRACK INDICATION AT RBL 9 OUTBOARD POST CRACK IS .5…
- 23 Mar 2011
Skin, dented
RIGHT INBOARD FLAP DENTED BETWEEN CANT FLAP STATION 79.062 AND CANT FLAP STATION 82.473 JUST FORWARD OF REAR SPAR ON THE UPPER SKIN. REPAIRED IAW BOMBARDIER…
- 30 Oct 2010
Stiffener, cracked
FOUND FS 409.00+128 VERTICAL POST AT LBL 18.00 I/B O/B SIDE HAS INDICATION NOTED APPROXIMATELY .200" IN LENGTH AT WL 69.0. REMOVED VERTICAL POST ASSEMBLY AT…
- 30 Oct 2010
Stiffener, cracked
FOUND FS 409.00+128 VERTICAL POST AT RBL 18.00 I/B O/B SIDE HAS INDICATION NOTED APPROXIMATELY .200" IN LENGTH AT WL 69.0. REMOVED VERTICAL POST ASSEMBLY AT…
- 30 Oct 2010
Sill, corroded
CARGO SILL PLATE CORRODED BEYOND LIMILTS. REMOVED CARGO SILL PLATE IAW CRJ200 SRM 51-42-06. LOCATED AND DRILL NEW SERVICEABLE CARGO SILL PLATE IAW CRJ 200 SRM…
- 1 Feb 2010
Unknown, odor
2/1/10 FLIGHT 4022 MEM TO TYS ON TAKEOFF RWY9 AFTER 120 KIAS, RECEIVED A SMOKE TOILET MASTER CAUTION MESSAGE. THERE WAS A SMELL OF PETROLEUM OR DEICE FLUID IN…
- 2 Feb 2007
Flap System, failed
FLAPS FAIL AT ZERO DEGREES UPON APPROACH. LANDING UNEVENTFUL. COMPLIED WITH AD 2001-12-21 BY RESET AND MONITORING FOR 72 HOURS.
- 24 Nov 2006
Flap, malfunctioned
FLAPS FAILED AT ZERO ON APPROACH. EMERGENCY DECLARED QRH FOLLOWED WITH UNEVENTFUL ZERO FLAP LANDING. SYSTEM RESET AND PLACED ON 72 HOUR WATCH PER AD 2006-12-21.
- 17 Jun 2006
Flap, malfunctioned
FLAPS FAIL. MONITORING FLAPS FOR 72 HOURS PER AD 98-20-01.
- 2 Mar 2006
Trim System, malfunctioned
ON APPROACH TO DTW BOTH STAB TRIM CHANNELS AND MACH TRIM DISENGAGED AND WOULD NOT RESET. RECEIVED STAB TRIM AND MACH TRIM CAUTION MESSAGES. CONTROLS FELT…