1 past record
- 1976
service difficulty reports
32 reports
- 29 Aug 2001
Battery Pack, discharged
DFW - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT PATH LIGHTING DIM THROUGHOUT COACH. REPLACED FORWARD AND AFT BATTERY PACKS. SYSTEM GROUND CHECKED NORMAL…
- 14 Mar 2001
Connector, damaged
DFW - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT LIGHT AT SEAT 15-22 DIM. REPAIRED EMERGENCY EXIT LIGHT CONNECTION. SYSTEM GROUND CHECKED NORMAL OPERATION.…
- 13 Mar 2001
Splice, damaged
DFW - DURING OVERNIGHT MAINTENANCE EMERGENCY EXIT LIGHT IN COACH CLASS INOPERATIVE. REPAIRED EMEREGNCY EXIT LIGHT SPLICE AT ROW 15 AND 25. SYSTEM GROUND…
- 16 Feb 2001
Light, defective
DFW - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT LIGHT DIM. REPAIRED EMERGENCY EXIT PATHWAY LIGHT. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)
- 15 Nov 2000
Light, broken
DFW - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT FLOOR TRACK PROXIMITY LIGHT BETWEEN SEAT ROW 6D AND 26D INOPERATIVE. REPAIRED EMERGENCY EXIT LIGHT SEGMENT…
- 30 Oct 2000
Stringer, corroded
TUL - FOUND CORROSION 1 INCH BY 1 INCH, ON EDGE OF STRINGER 26L. FABRICATED AND INSTALLED STRINGER REPAIR IAW SRM 53-10-3 FIG 2 SHEET 2. (M)
- 30 Oct 2000
Grommet, damaged
TUL - FOUND STATION 720B LEFT RAM AIR MOTOR SHAFT GROMMET PUSHED UP OFF OF INNER SKIN. INSTALLED DOUBLER PER SRM 53-30-3 FIG 3, SHEET 4, PAGE 13. (M)
- 27 Oct 2000
Skin, corroded
TUL - FOUND CORROSION 1.5 INCH BY 10 INCH ON FUSELAGE SKIN STATION 560-570, OUTBOARD OF STRINGER 27L. INSTALLED DOUBLER WET WITH SEALANT AND FILLER SEALED…
- 9 Mar 2000
Wire, broken
DFW - DURING OVERNIGHT MAINTENANCE, EMERGENCY LIGHTING FROM STATION BS 360 TO BS 780 INOPERATIVE. REPAIRED BROKEN WIRE AT BS 360 RBL 12. SYSTEM GROUND CHECK…
- 15 Sep 1999
Connector, loose
DFW - DURING OVERNIGHT MAINTENANCE, EMERGENCY EXIT FLOOR PATH LIGHTS IN AFT CABIN INOPERATIVE. RESECURED CONNECTOR TO EMERGENCY FLOOR PATH LIGHTING IN AFT…
- 19 May 1999
Wire, broken
DFW - OVERNIGHT MAINTENANCE EMERGENCY EXIT SIGN INOPERATIVE. REPAIRED WIRES TO EMERGENCY EXIT SIGN. SYSTEM GROUND CHECKED, NORMAL OPERATION. (X)
- 11 Jan 1999
Oring, failed
DFW - FLT 1503 - EN ROUTE DFW-MCI, DURING TAKEOFF WHILE PERFORMING FLAP RETRACTION LOSS ALL SYSTEM 'A' PRESSURE AND QUANTITY. RETURNED DFW AND MANUALLY…
- 26 Sep 1998
Motor, malfunctioned
ORD - FLT 1214 - EN ROUTE ORD-YYZ - LOST SYSTEM 'A' HYDRAULIC IN FLIGHT. RETURNED ORD, MANUALLY EXTENDED LANDING GEAR, ELECTRICALLY EXTENDED FLAPS AND LANDED…
- 3 Jul 1998
Clamp, loose
BNA - FLT 0405 - DURING CLIMB-OUT PASSING FL 300, CREW NOTICED LOWER AFT BODY OVERHEAT LIGHT ILLUMINATED. CREW ACCOMPLISHED EMERGENCY CHECK LIST, AIR…
- 26 Jun 1998
Filter, dirty
RSW - FLT 1383 - DURING CRUISE, EN ROUTE ATL-MIA, LOWER AFT BODY HEAT LIGHT FLICKERED ON AND OFF SEVERAL TIMES. AIR INTERRUPTED AND LANDED RWS WITHOUT…
- 16 Dec 1997
Spar Web, cracked
TUL - STATIONS 870 SPAR WEB CENTER TANK CRACKED RBL 3. INSTALLED DOUBLER PER ESO 11697, DATED 12/9/97. (M)
- 12 Oct 1997
Duct, leaking
TPA - FLT 1553 - AFTER TAKEOFF TPA DURING CLIMB-OUT, NR 1 ENGINE STRUT OVERHEAT LIGHT ILLUMINATED. ACCOMPLISHED ABNORMAL PROCEDURE AND LIGHT EXTINGUISHED WHEN…
- 8 Apr 1997
Seal, defective
ORD - FLT 1418 - DURING APPROACH TO ORD WHEN LANDING GEAR EXTENDED, NOSE LANDING GEAR DOOR LIGHT REMAINED ILLUMINATED WITH NO OTHER ABNORMAL INDICATIONS.…
- 14 Jan 1997
Floorbeam, corroded
TUL - CORROSION ON CABIN FLOORBEAM LOWER FORWARD CHORD, STATION 1130, LBL 35. REMOVED CORROSION, DYE CHECK. NO CRACKS FOUND. INSTALLED REPAIR DOUBLERS PER A/A…
- 14 Jan 1997
Floorbeam, corroded
TUL - CORROSION ON UPPER FLANGE OF FLOORBEAM TOP AND BOTTOM SIDES, CPC C53-274-03 E58-4-8844. CUT OUT CORRODED AREA AND INSTALLED FILLER AND STAINLESS .060…
- 14 Jan 1997
Stringer, cracked
TUL - TWO CRACKS IN STRINGER END AT WING LIGHT, FORWARD SIDE. CUT OFF APPROX 12 INCHES OF STRINGER AND INSTALLED NEW PIECE WITH REPAIR CHANNELS PER SRM 53-103…
- 14 Jan 1997
Sill, corroded
TUL - FORWARD ENTRY DOOR CUTOUT LOWER SILL WEB AND CREASE ANGLE HEAVILY CORRODED FS 328 TO 344. REMOVE CREASE ANGLE AND INSTALLED NEW ANGLE AS PER SRM…
- 14 Jan 1997
Frame, corroded
TUL - CORROSION ON FRAME REMOVED BEYOND LIMITS. CUT OUT AREA AND INSTALLED DOUBLER PER SRM 51-40-2. (M)
- 14 Jan 1997
Floorbeam, corroded
TUL - BS 1030 BL 0 - LBL 10, CORROSION ON TOP FLANGE OF FLOORBEAM. CUT OUT AREA OF CORROSION AND INSTALLED REPAIR PER SRM 53-10-8. (M)
- 14 Jan 1997
Frame, corroded
TUL - CORROSION AT LEVELING COMPOUND BETWEEN STRINGER 28R AND 28L, APT OF FRAME STATION 720. REMOVED CORROSION PER SRM 51-10-6 (BEYOND LIMITS). INSTALLED…
- 9 Dec 1996
Skin, corroded
TUL - CORROSION AT LEVELING COMPOUND ON BELLY SKIN BETWEEN STRINGER 28R AND STRINGER 28L, AFT SIDE OF FRAME STATION 660. CORROSION BEYOND LIMITS, CORRODED…
- 4 Dec 1996
Skin, corroded
TUL - CORROSION ON SKIN LAP ABOVE STRINGER 26R AT STATION 720B TO 720C. CORRODED SECTION CUT OUT, INSTALLED DOUBLER REPAIR PER SRM 53-30-3 FIG 5 AND INSTALLED…
- 4 Dec 1996
Floorbeam, corroded
TUL - FLOORBEAM CORRODED STATION 380 RBL 10-40. REPLACED FLOORBEAM TOP CAP PER SRM 53-10-8. (M)
- 4 Dec 1996
Floorbeam, corroded
TUL - BS 380 RBL 45 - RBL 70, CORROSION ON TOP FLANGE OF FLOORBEAM. REPLACED FLOORBEAM TOP CAP PER SRM 53-10-8. (M)
- 4 Dec 1996
Angle, corroded
TUL - CORROSION AT CREASE ANGLE BEAM INSIDE AFT CORNER OF FORWARD ENTRY DOOR. REMOVED CORRODED CREASE ANGLE AND INSTALLED NEW ANGLE AS PER SRM 51-10-01. (M)
- 9 Oct 1995
Heat Valve, defective
ALT - FLT NR 1142 - WHILE EN ROUTE DFW-ATL, THE NR 3 ENGINE FUEL HEAT VALVE BECAME STUCK IN THE OPEN POSITION, RESULTING IN ABNORMALLY HIGH OIL TEMPERATURE.…
- 21 Jul 1995
Eel Connector, broken
DFW - DURING OVERNIGHT CHECK, EMERGENCY FLOOR LIGHTS BETWEEN PASSENGER SEAT ROWS 7 AND 24 INOPERATIVE. REPLACED BROKEN EMERGENCY FLOOR LIGHT CONNECTORS BY…