N8492C
2001 Bombardier INC CL-600-2B19 standard FAA →
registration
- 2001
earlier registrations
1 past record
owner withheld at the FAA
service difficulty reports
40 reports
- 1 Jan 2014
Container, torn
CAPTAIN`S LIFE VEST BAG TORN. R & R CAPTAIN`S LIFE VEST IAW AMM 25-61-03.
- 18 Nov 2013
Connector, broken
EMERGENCY LIGHT STRIP FWD FLOOR CONNECTOR AT PANEL 231ALF IS BROKE OFF. REPLACED EMERGENCY LIGHT STRIP FWD FLOOR CONNECTOR AT PANEL 231ALF IAW CRJ 200 ESPM…
- 8 Nov 2013
Lug, corroded
LEFT INBD FLAP, INBD HINGE BOX ON WING INBD LUG SHOWS SIGNS OF CORROSION COMMON TO THE BUSHING. REPAIRED IAW REO 601R-57-21-2027.
- 8 Nov 2013
Lug, corroded
RIGHT INBD FLAP, INBD HINGE BOX ON WING INBD LUG, SHOWS SIGNS OF CORROSION COMMON TO THE BUSHING. REPAIRED IAW REO 601R-57-21-2027.
- 28 Oct 2013
Bulkhead, chafed
AFT PRESSURE BULKHEAD AT FS 621, WL 110.5, LBL 42.7 CHAFED. REPAIRED IAW REOS 601R-53-61-2155, 601R-53-61-1230, AND 601R-53-61-5069.
- 26 Oct 2013
Access Panel, corroded
CENTER WING LOWER FUEL ACCESS PANEL 510BB GASKET MATING SURFACE WORN AROUND PERIMETER AND CORRODED IN THE NON-CRITICAL REGION 0.5" X 0.125" X 0.002" DEEP.…
- 25 Oct 2013
Bulkhead, damaged
FORWARD FACE OF FS 621 BULKHEAD HAS FOUR SCREW MARKS. FOUND TO BE WITHIN LIMITS OF REO 601R-53-61-2155.
- 27 Jun 2013
Flap System, failed
FLAPS FAILED AT 17 DEGREES ON LANDING AT RETRACTION.
- 2 Apr 2013
Seal, broken
FLIGHT ATTENDENT REPORT SEAL ON EMK BROKEN. VERIFIED SEAL ON EMK BAG ARE INTACT. CLOSED AND LOCKED COMPARTMENT INSTALLED SEAL.
- 26 Feb 2013
Life Vest, unserviceable
FIRST OFFICER'S LIFE VEST HAS HOLE IN BAG. REMOVED AND REPLACED FIRST OFFICER'S LIFE VEST IAW AMM 25-61-03.
- 7 Dec 2012
Light, inoperative
FWD OVERHEAD EMERGENCY LIGHT INOP. REPLACED NR 1 CEILING EMERGENCY FLOOD LIGHT BULB AND OPS TEST GOOD IAW AMM 33-51-16. THIS CLEARS THE DM. PLACARD REMOVED.
- 25 Oct 2012
Wire, broken
WARDROBE EMERGENCY LIGHTED "EXIT" SIGN INOP, WIRE BROKEN AT LIGHT. REMOVED & REPLACED EXIT SIGN, FLOOR LEVEL IAW AMM 33-51-10. PERFORMED OPS CHECK IAW AMM…
- 19 Jun 2012
Bulkhead, chafed
AFT PRESSURE BULKHEAD CHAFED JUST ABOVE FLOORBOARD. DAMAGE REMOVED IAW REO 601R-53-61-2155 RESULTING IN 0.001 INCH REMOVED.
- 19 Jun 2012
Bulkhead, damaged
A DRILL START WAS NOTED AT FS621 BULKHEAD AT WL113 MEASURING 0.023 INCH DEEP. REPAIRED IAW BOMBARDIER REO 601R-53-61-1230 REV F.
- 15 Jun 2012
Seat Track, corroded
LEFT FLOOR SEAT TRACK HAS EVIDENCE OF CORROSION. REMOVED CORROSION IAW SRM 53-21-49 FROM FS364 TO 394 AT LBL9.
- 15 Jun 2012
Seat Track, corroded
LEFT SEAT TRACK AT LBL9 BETWEEN FS 559 AND 559+96 CORRODED. CORROSION REMOVED IAW SRM 53-51-49.
- 15 Jun 2012
Seat Track, corroded
LEFT FLOOR SEAT TRACK AT LBL 9 BETWEEN FS 394 AND 409+128 CORRODED. CORROSION REMOVED IAW SRM 53-31-49.
- 13 Jun 2012
Skin, chafed
RIGHT AILERON SKIN LEADING EDGE CHAFED TOP AND BOTTOM. REPLACED IAW SRM 51-42-06 AND 51-42-13.
- 13 May 2012
Life Vest, damaged
OBSV'S LIFE VEST BAG DAMAGED. REMOVED AND REPLACED OBSV'S LIFE VEST IN ACCORDANCE WITH AMM 25-61-03.
- 13 May 2012
Light, inoperative
LEFT NR 3 EMERGENCY LIGHT INOPERATIVE. REMOVED AND REPLACED LEFT NR 3 EMERGENCY LIGHT IAW AMM 33-51-21. OPS CHECKED GOOD.
- 25 Apr 2012
Friction Lock, stuck
THRUST LEVER FRICTION ADJUSTMENT KNOB IS STUCK WILL NOT MOVE EITHER DIRECTION. RELEASED THRUST LEVER FRICTION LOCK FROM BEING OVER TIGHTENED. OPS CHECK NORMAL…
- 30 Mar 2012
Cable, loose
MAIN CABIN DOOR WHEEL IS DISCONNECTED FROM DOOR CABLE & IS NOT IN CONTACT WITH THE GROUND. INSTALLED PAX DOOR SUPPORT WHEEL CABLE ONTO PULLEY. OPS CHECKED…
- 3 Feb 2012
Battery, discharged
F/A'S FLASHLIGHT STRAP IS BROKEN AND DOES NOT BLINK RED. REMOVED AND REPLACED F/A FLASHLIGHT BATTERY AS REQ'D. VERIFIED PART EFFECTIVITY. OK FOR SVC.
- 5 Dec 2011
Light, loose
EMERGENCY FLOOR LIGHTING FROM THE EXIT ROW AFT IS INOPERATIVE. RE-SECURED LOOSE FLOOR LIGHTING. OPS CHECK GOOD, REF AMM 33-51-00.
- 25 Oct 2011
Control Panel, defective
RUDDER TRIM INOP, CB IS TRIPPED, RESET PER MOC, TRIPPED AGAIN WHEN TESTING. REMOVED AND REPLACED RUDDER TRIM CONTROL PANEL IAW AMM 27-12-10-04. OP/C GOOD.…
- 23 Oct 2011
Bulkhead, chafed
FS 621.0 PRESSURE BULKHEAD FWD FACE HAS 5 EACH CHAFES 30 ABOVE FLOOR AT LBL 27, LBL 18, RBL 27, AND RBL 36. MAXIMUM CHAFE DAMAGE IS APPROX .163L X .163W X…
- 23 Oct 2011
Bulkhead, chafed
FS 621.0 PRESSURE BULKHEAD FWD FACE HAS 4 EACH CHAFES AT LBL 32, LBL 23, LBL 14, AND RBL 41 2 ABOVE FLOOR. REPAIRED IAW BOMBARDIER REOS 601R-53-61-2155 AND…
- 19 Oct 2011
Structure, chafed
RT WING FUEL TANK ACCESS HOLE NR 16 AT WS 303.861 IS CHAFED ON THE I/B END APPROX .002 D IN NON-CRITICAL REGION. REPAIRED IAW BOMBARDIER REO 601R-57-21-030…
- 19 Oct 2011
Structure, damaged
LT WING FUEL TANK ACCESS HOLE NR 2 AT WS 12.245 HAS AREAS OF PITTING APPROX .004 D IN CRITICAL AND NON-CRITICAL REGIONS. REPAIRED IAW BOMBARDIER REO…
- 19 Oct 2011
Structure, corroded
LT WING FUEL TANK ACCESS HOLE NR 1 AT WS 54.897 HAS MINOR CORROSION AT I/B SIDE APPROX 002 D IN NON-CRITICAL REGION. REPAIRED IAW BOMBARDIER REO…
- 19 Oct 2011
Angle, corroded
CARGO BAY LBL 27 CAP ANGLE OUTBOARD SIDE CORRODED AROUND NUT PLATE HOLES FS 574-621. REPAIRED IAW SRM 51-40-11, 53-61-43 AND BOMBARDIER REO 601R-53-61-3778.
- 18 Oct 2011
Floor Support, cracked
FS 280 FLOOR SUPPORT WEB CRACKED O/B OF LBL 9, AND LBL AND RBL 9 FLOORBEAM CLIPS ARE CRACKED (I/B AND O/B), AND AFT J-ANGLE HAS AREAS OF CORROSION AROUND NUT…
- 16 Oct 2011
Skin, gouged
RT SIDE EXTERNAL FUSELAGE HAS A LIGHT GOUGE BETWEEN FS 559.00+112 AND FS 574.00, BETWEEN STRINGERS 20 AND 21. REPAIRED IAW SRM 53-00-31 REPAIR 8.
- 11 Nov 2010
Skin, damaged
DURING OVERNIGHT MAINTENANCE IN LEXINGTON, KEY (LAX), THE GROUND POWER UNIT (GPU) ACCESS DOOR LANDING WAS FOUND DEFORMED AND DAMAGED IN THE UPPER FORWARD…
- 4 Feb 2007
Flap System, unknown
FLAPS FAIL ON APPROACH. LANDING UNEVENTFUL. COMPLIED WITH AD 2006-12-21, RESET AND MONITORING FOR 72 HOURS.
- 26 Feb 2006
Flap System, malfunctioned
DURING CLIMBOUT UPON SELECTION OF FLAPS UP RECEIVED FLAPS FAIL CAUTION MESSAGE. FOLLOWED QRH, DECLARED EMERGENCY RETURNED TO RIC WITH UNEVENTFUL LANDING.…
- 5 Feb 2006
Flap, malfunctioned
FLAP FAIL AT 45 DEGREES ON APPROACH. RESET SYSTEM AND PLACED ON 72 HOUR WATCH PER AD 98-20-01.
- 27 Aug 2005
Dcu, failed
ON ROTATION ICE CAUTION FOLLOWED BY MASTER CAUTION LEFT ENGINE FIRE FOLLOWED BY ASSORTED OTHER MESSAGES. DECLARED EMERGENCY AND LANDED. UPON INVESTIGATION…
- 17 Jul 2001
Hose, ruptured
OBSERVER SEAT POSITION OXYGEN MASK SUPPLY HOSE RUPTURED AND SEPARATED FROM FITTING. REMOVED AND REPLACED HOSE. THIS WAS FOUND WHILE INVESTIGATING A DEPLETED…
- 11 Jun 2001
Bpsu, failed
FLAP FAILURE MESSAGE AND FLAPS STUCK AT 20 DEGREES. INTERROGATED FECU (FLAP ELECTRONIC CONTROL UNIT) FOUND LEFT BPSU (BRAKE POSITION SENSING UNIT) FAILURE…