N830AS
1998 Canadair CL-600-2B19 standard FAA →
reservations
earlier registrations
1 past record
- 1998
NTSB
- 28 Feb 2009
accident, Tallahassee FL
service difficulty reports
122 reports
- 22 Apr 2015
Door, binding
MAIN CABIN DOOR WILL NOT OPEN OR CLOSE. REMOVED FWD UPPER PANEL ON PAX DOOR. INSPECTED OUTTER HANDLE STOW MECH. NO DEFECTS NOTED. LUBED STOW MECH. IAW NMM…
- 7 Sep 2014
Door, lack of lube
COULD NOT OPEN PAX DOOR FROM THE OUTSIDE, HAD TO GO IN THRU THE SERVICE DOOR AND OPEN THE DOOR FROM THE INSIDE. CLEANED AND LUBED PAX DOOR. PERFORMED OPS CK…
- 10 Aug 2014
Pushrod, out of adjust
PAX DOOR WONT OPEN EASILY. FOUND PUSHROD TO LATCH CAM TORQUE TUBE TO BE OUT OF ADJUSTMENT. ADJUSTED PUSHROD IAW AMM 52-11-21. OPS CHECKED GOOD IAW AMM 52-11-00.
- 9 Aug 2014
Door, lack of lube
PASSENGER DOOR WOULD NOT OPEN FROM INSIDE OR OUTSIDE AT GATE. CLEANED AND LUBED PAX DOOR IAW AMM 12-20-52. OPS CHECKED GOOD IAW AMM 52-11-00.
- 5 May 2014
Sign, inoperative
LIGHTED FLOOR LEVEL EXIT SIGN INOPERATIVE AT LEFT EMERGENCY EXIT. R & R SIGN IAW AMM 33-51-10. SYSTEM OPS CHECKED GOOD. NO FURTHER ACTION.
- 28 Apr 2014
Light, inoperative
EXTERIOR EMERGENCY LIGHT NR 4 INOPERATIVE. R & R LIGHT ASSY IAW AMM 33-51-21. SYSTEM OPS CHECKED GOOD. NO FURTHER ACTION.
- 15 Dec 2013
Lens, missing
NR 3 EMERGENCY CEILING LIGHT COVER MISSING. INSTALLED COVER IAW AMM 33-51-16. NO FURTHER DEFECT NOTED.
- 19 Nov 2013
Skin, cracked
LT WING FUEL ACCESS PANEL 540EB HAS AN INDICATION ON THE INBD SIDE APPROX .5 X .25" 50 PERCENT FSH FAILED NDT INSPECITON. COMPLIED WITH ECTC EO 600-57-81 C/W…
- 17 Nov 2013
Skin, cracked
LOWER WING PLANK RT BOOST PUMP CUT OUT LANDING FOR ACCESS PANEL HAS MULTIPLE INDICATIONS NOTED ON HORIZONTAL AND VERTICAL SURFACES 50 PERCENT FSH AROUND…
- 15 Nov 2013
Bulkhead, cracked
FOUND REAR PRESSURE BULKHEAD WEB HAS INDICATION NOTED AT LBL 27.50, WL 130 APPROX .3" IN LENGTH 100 PERCENT FSH FAILED NDT INSPECTION. COMPLIED WITH ECTC REO…
- 12 Nov 2013
Intercostal, cracked
INTERCOSTAS BETWEEN STRINGERS 12A & 13A LT AT FS 625 ARE CRACKED. REMOVED INTERCOSTAL IAW SRM 51-42-06 AND 51-42-21. INSTALLED NEW SERVICEABLE INTERCOSTAL IAW…
- 12 Nov 2013
Angle, cracked
BS 625 ANGLE CRACKED. REMOVED ANGLE IAW SRM 51-42-21. LOCATED, DRILLED & INSTALLED NEW ANGLE IAW SRM 51-40-11 & 51-42-21.
- 12 Nov 2013
Light, damaged
EMERGENCY LIGHT SECTIONS NR 1 AND 2 FAIL INSPECTION. LENS ARE CRACKED AND CRAZED AND LIGHT STRIPS ARE FADED AND DIM. REMOVED DAMAGED LIGHTS AND INSTALLED…
- 12 Nov 2013
Lens, damaged
LT CABIN EMERGENCY LIGHT SECTIONS FAIL INSPECTION. COVERS ARE CRACKED AND CRAZED AND LIGHTS ARE FADED. REMOVED DAMAGED SECTIONS AND INSTALLED SERVICEABLE IAW…
- 11 Nov 2013
Isolator, broken
REAR PRESSURE BULKHEAD FORWARD FACE HAS BROKEN ISOLATORS. REMOVED BROKEN ISOLATORS IAW SRM 51-42-10 AND REPLACED IAW SRM 51-42-13.
- 11 Nov 2013
Seat Track, corroded
SEAT TRACK BETWEEN BS 409 AND 409+128 HAS CORROSION AROUND FASTENERS. FABRICATED NEW SEAT TRACK SECTION, LOCATED AND DRILLED PREPPED SURFACE AND TOP COATED…
- 11 Nov 2013
Seat Track, corroded
SEAT TRACK BETWEEN BS 409 AND 409+128 HAS CORROSION AROUND FASTENERS. FABRICATED, DRILLED AND LOCATED NEW SEAT TRACK IAW REO 601R-53-00-485. REMOVED SEAT…
- 11 Nov 2013
Floorbeam, corroded
FS 280 FLOORBEAM AFT ANGLE IS CORRODED AROUND FASTENER HOLES FROM LBL 9 TO RBL 9. R & R ANGLE IAW REO 601R-53-11-926, REV B. COMPLIED WITH EC/TC REO…
- 10 Nov 2013
Floor Support, cracked
BS 484 FLOOR SUPPORT PREVIOUS REPAIR ANGLE IS CRACKED, AT RBL 36.00. REMOVED & INSTALLED NEW ANGLE IAW 51-42-21 AND REO 601R-53-41-059. FABRICATED ANGLE IAW…
- 10 Nov 2013
Floorbeam, cracked
BS 280, FLOORBEAM ANGLE HAS THREE CRACKS AT LBL 9 - RBL 9 . REMOVED FLOORBEAM ANGLES IAW SRM 51-42-21. REPLACED DURING INCORPORATION OF REO 601R-53-11-926.
- 10 Nov 2013
Handle, out of adjust
PAX DOOR HANDLE IS DIFFICULT TO OPEN FROM OUTSIDE, INNER DOOR PLUNGER IS TOUGH TO CLOSE, PAX DOOR LATCH CAUTION MESSAGE IN FLIGHT. ADJUSTED THE PULL-IN LEVER…
- 10 Nov 2013
Skin, corroded
RT WING SKIN ACCESS HOLE -640BB HAS AERAS OF CORROSION. COMPLIED WITH ECTC EO 600-57-81 C/W IAW REO 601R-57-21-030, REV K.
- 10 Nov 2013
Floorbeam, corroded
BS 280 FLOORBEAM FWD ANGLE CORRODED LBL 9 - RBL 9. REMOVED ANGLE IAW SRM 51-42-06 AND 51-42-21. INSTALLED NEW SERVICEABLE ANGLE IAW SRM 51-42-06 & 51-42-21.
- 10 Nov 2013
Floor Support, corroded
PASSENGER COMPARTMENT FLOOR SUPPORT CORRODED AT LBL 45 FROM BS 349-379. REMOVED FLOOR SUPPORT IAW SRM 51-42-66. LOCATED & DRILLED NEW FLOOR SUPPORT IAW…
- 10 Nov 2013
Seat Track, corroded
SEAT TRACK LBL 9 CORRODED FROM BS 364-394. REMOVED SEAT TRACK IAW AMM 53-01-11-000-802. INSTALLED NEW SERVICEABLE SEAT TRACK IAW AMM 53-01-11-400-802.
- 8 Nov 2013
Skin, chafed
LEFT AILERON UPPER L/E IS CHAFED IN SEVERAL AREAS, ALL ALONG L/E SURFACE. DEEPEST CHAFE APPROX .005 DEEP. COMPLIED WITH STEPS NR 1 THRU NR 3 OF REO…
- 4 Nov 2013
Skin, cracked
.8 INCH CRACK IN RT WING LOWER WING PLANK. COMPLIED WITH EC/TC REO 601R-57-21-130 01 AND REO 601R-57-21-130, REV J. COMPLIED WITH EC/TC REO 601R-57-21-131 AND…
- 25 Oct 2013
Handle, stiff
PASSENGER DOOR HANDLE IS DIFFICULT TO OPEN FROM OUTSIDE. IT IS ALSO DIFFICULT TO STOW THE HANDLE INSIDE AT TIMES. DID FIT AND CLEARANCE CHECK OF DOOR HANDLE,…
- 22 Jul 2013
Handle, lack of lube
PAX DOOR WONT OPEN FROM OUTSIDE. PERFORMED OPS TEST OF PAX DOOR SEVERAL TIMES, AND LUBED PAX DOOR HANDLE INNER MECHANISM. OPS GOOD IAW AMM 52-11-00 ACFT OK…
- 10 Jun 2013
Door, binding
CREW REPORTS THAT THE PASSENGER DOOR IS DIFFICULT TO OPEN. REMOVED EXCESS AMOUNT OF GREASE FROM PASSENGER DOOR LOCKPINS AND CAMLOCKS IAW AMM 12-20-52. NO…
- 22 Mar 2013
Latch, lack of lube
PAX DOOR LATCH HARD TO CLOSE OR OPEN. LUBRICATED PASSENGER DOOR HANDLE LATCH. OPS CHECKED OK MM 52-10-00.
- 21 Jan 2013
Lens, broken
RIGHT SIDE ABOVE WING EMERGENCY LIGHT HSG BROKEN. R & R THE RT SIDE EMERGENCY LIGHT COVER IAW AMM 33-51-21. OPS CHECK GOOD. CDL CLEARED. MCC NOTIFIED.
- 21 Jan 2013
Lens, broken
LEFT SIDE AFT ABOVE WING EMERGENCY LIGHT HSG BROKEN. R & R THE LT SIDE EMERGENCY LIGHT COVER IAW AMM 33-51-21. OPS CHECK GOOD. CDL CLEARED. MCC NOTIFIED.
- 21 Jan 2013
Lens, broken
R & R THE LT SIDE ABOVE WING EMERGENCY LIGHT HOUSING BROKEN. R & R THE LT SIDE EMERGENCY LIGHT COVER IAW AMM 33-51-21. OPS CHECK GOOD. CDL CLEARED. MCC…
- 17 Jun 2012
Tire, failed
RIGHT NOSE TIRE BLEW AT V1 (ACFT RETURNED TO DEPARTURE AFTER T/O -- EMERGENCY DECLARED AS A PRECAUTION). PERFORMED VISUAL INSP OF NLG AND DOORS IAW…
- 4 May 2012
Fixture, burned
BURNING ODOR IN COCKPIT AND GALLEY AREA. (WORK LIGHTS) R & R BURNED GALLEY LIGHT FIXTURE. OPS CHECKED GOOD IAW AMM 33-26-047.
- 8 Dec 2011
Apu, smoke
AFTER APU SHUTDOWN, THERE WAS A LARGE AMOUNT SMOKE COMING FROM APU EXHAUST AREA AUXILIARY POWER UNIT APU. DOOR POSITION VERIFIED CLOSED. R & R APU ASSEMBLY…
- 25 Nov 2011
Housing, broken
WARDROBE AFT EMERGENCY LIGHT HOUSING BROKEN. R & R FLOOR LEVER EMERGENCY FLOOD LIGHT HOUSING ON WARDROBE IAW AMM 33-51-19-000-801 & 33-51-19-400-801. OPS…
- 21 Nov 2011
Angle, corroded
SERVICE DOOR THRESHOLD ANGLE CORRODED. REMOVED SILL ANGLE IAW SRM 51-42-21. SILL ANGLE AND INSTALLED IAW SRM 51-40-11 AND SRM 51-42-21.
- 16 Nov 2011
Crossbeam, corroded
CORROSION ON CROSSBEAM AT 349 AND RBL 41 TO RBL 42. REPAIRED IAW SRM 51-24-06 AND REO 601R-53-21-2224.
- 14 Nov 2011
Bulkhead, cracked
AFT EQUIPMENT BAY, PRESSURE BULKHEAD RT CLIP CRACKED AT FS 625.
- 14 Nov 2011
Stand Off, cracked
CARGO COMPARTMENT AFT BULKHEAD STAND OFF BRACKET CRACKED RT PRESSURE BULKHEAD 1ST FROM FLOOR. REMOVED AND INSTALLED NEW STAND OFF MOUNT IAW SRM 51-77-00,…
- 14 Nov 2011
Bracket, cracked
CARGO DOOR FWD RAIL SUPPORT BOTTOM BRACKET CRACKED. REMOVED CARGO DOOR FWD RAIL SUPPORT BRACKET FOR REPLACEMENT IAW SRM 51-41-02 & SRM 51-42-06. DRILLED NEW…
- 10 Nov 2011
Cargo Track, corroded
CARGO TRACK CORRORED AT 559.00 + 112 AND RBL 9. REMOVED CARGO TRACK AT 559.00+112 RBL 9 IAW AMM 53-01-11-000-802. INSTALLED TRACK RAIL IAW AMM 20-21-00-910-801.
- 10 Nov 2011
Cargo Track, corroded
CARGO TRACK CORRORED AT 559.00 + 112 AND LBL 9. REMOVED CARGO TRACK IAW AMM 53-01-44-000-802. INSTALLED TRACK RAIL IAW AMM 20-21-00-910-801. REPLACED DAMAGE…
- 10 Nov 2011
Cargo Track, corroded
CARGO TRACK CORRORED AT 559.00 + 80 AND RBL 27. REMOVED CARGO TRACK IAW AMM 53-01-11-000-802. INSTALLED CARGO TRACK IAW AMM 20-21-00-910-801.
- 10 Nov 2011
Cargo Track, corroded
CARGO TRACK CORRORED AT 559.00 + 80 AND RBL 9. REMOVED CARGO TRACK IAW AMM 53-01-11-000-802. INSTALLED CARGO TRACK IAW AMM 20-21-00-910-801. REPLACE DAMAGED…
- 10 Nov 2011
Cargo Track, corroded
CARGO TRACK CORRORED AT 559.00 + 80 AND LBL 9. REMOVED CARGO TRACK IAW AMM 53-01-11-000-802. INSTALLED CARGO TRACK IAW AMM 20-21-00-910-801.
- 10 Nov 2011
Cargo Track, corroded
CARGO TRACK CORRORED AT FS 559.00 + 80 AND LBL 27. REMOVED CARGO TRACK IAW AMM 53-01-11-000-802. INSTALLED CARGO TRACK IAW AMM 20-21-00-910-801.
- 10 Nov 2011
Floorbeam, corroded
CORROSION ON FLOORBEAM AT FS 349. RBL 41 TO RBL 42. REPAIRED IAW REO 601R-53-21-2224, STEP 1 & 2.
- 10 Nov 2011
Structure, cracked
AFT EQUIPMENT BAY, PRESSURE BULKHEAD RT CLIP CRACKED AT FS 625. R & R FWD CARGO DOOR INNER SEAL RETAINER IAW SRM 51-40-11-001-001 AND SRM 51-41-02-001-001.
- 10 Nov 2011
Threshold, corroded
SERVICE DOOR THRESHOLD CORRODED. REMOVED CORROSION IAW SRM 51-21-06. CORROSION FOUND TO BE OUT OF LIMITS IAW SRM 53-00-00. REPAIRED IAW SRM 51-42-21 AND…
- 10 Nov 2011
Stand Off, cracked
CARGO COMPARTMENT AFT BULKHEAD STAND OFF BRACKET CRACKED RT PRESSURE BULKHEAD 1ST FROM FLOOR. REMOVED AND INSTALLED NEW STAND OFF MOUNT IAW SRM 51-77-00,…
- 12 Sep 2011
Door, binding
MAIN DOOR WILL NOT OPEN FROM OUTSIDE. CYCLED THE PAX DOOR SEVERAL TIMES. NO DEFECTS NOTED IAW AMM 52-10-01.
- 1 Apr 2011
Unknown, odor
STARTED THE APU ON DESCENT DID NOT START. WAITED 2 MINUTES. RESTARTED THE APU. WE HAD A STRONG FUEL ODOR THROUGHOUT THE PLANE. SHUT DOWN APU. STRONG ODOR…
- 24 Jan 2011
Proximity Sensor, out of adjust
PASSENGER DOOR WARNING IN FLIGHT. ACFT RETURNED TO DEPARTURE AFTER T/O -- EMERGENCY DECLARED. ADJUSTED FWD AND AFT LATCH PROX SENSORS (PS5M3 AND PS6MB) IAW…
- 28 Sep 2010
Line, leaking
HYD SYS 2 FAILURE IN FLIGHT PRESSURE AND QTY INDICATE 0. (EMERGENCY DECLARED -- ENROUTE TO IAD ACFT DIVERTED DUE TO MX) FOUND HYD SYS NR 2 PRESSURE LINE ON…
- 8 Nov 2009
Placard, unknown
PAX DOOR PLACARDS (7) TOTAL NEED REPLACED. "OPEN" , "TO OPEN LIFT HANDLE/PUSH DOOR", "EXIT", AND STRIPS ON ENDS OF STEPS.
- 4 Nov 2009
Floor Skin, cracked
FOUND FS 460 PRESSURE FLOOR SKIN HAS MULTIPLE INDICATIONS NOTED BETWEEN BL0.0 AND RBL9.0 1.5" IN LENGTH 60 PERCENT FSH. FAILED NDT INSP AREAS MARKED ON ACFT.
- 26 Oct 2009
Angle, damaged
INDICATION NOTED 75 PERCENT FSH APPROX 0.2" LONG EXTENDING FROM THE UPPER FASTENER OF ANGLE LOCATED AT RBL 27.50, FS 624.00 (APPROX), WL 119 (APPROX) FAILS…
- 22 Oct 2009
Post, cracked
FOUND FS 409+128 IB SIDE VERTICAL POST RBL 18.0 HAS AN INDICATION NOTED APPROX .2" IN LENGTH 50% FSH AT WL 49.0 AFT FLANGE RADIUS. FAILED NDT INSPECTION.…
- 22 Oct 2009
Post, cracked
FOUND FS 409+128 OB SIDE VERTICAL POST LBL 18 HAS AN INDICATION NOTED APPROX .2" IN LENGTH 50% FSH AT WL 69.0 AFT FLANGE RADIUS. FAILED NDT INSPECTION.…
- 16 Oct 2009
Frame, corroded
CORROSION ON OUTER FRAME FLANGE AT FS 319 AT STR 25L-26L. CUT FLANGE/REMOVED FLANGE ON FS 319 AT STR 25L-26L IAW REO 601R-53-21-1060 & SRM 53-00-15, REPAIR 2.…
- 16 Oct 2009
Bulkhead Web, cracked
5 INDICATIONS NOTED ON FS 559.0 BULKHEAD WEB AND CAP ANGLE AS LISTED: (1) 100 PERCENT FSH, 1 INCH LONG IN WEB AT RBL 18.0 WL 59.10 (2) 75 PERCENT FSH 0.25…
- 16 Oct 2009
Support Beam, cracked
ACM/ ECU SUPPORT BEAM CRACKED AT OTBD END AT FS 718 STR 11.
- 16 Oct 2009
Structure, corroded
MAIN AVIONICS COMPARTMENT FS 333, STR 26L - STR 27 CTR HAS CORROSION COMMON TO FRAME.
- 16 Oct 2009
Frame, corroded
MAIN AVIONCIS COMPARTMENT FS 349, STR 27 HAS CORROSION ON FRAME.
- 15 Oct 2009
Support Angle, cracked
LT WING TO FUSELAGE ACCESS FAIRING SUPPORT ANGLE CRACKED AT FS 469.53.
- 15 Oct 2009
Support Angle, cracked
LT WING TO FUSELAGE ACCESS FAIRING SUPPORT ANGLE CRACKED AT FS 476.57.
- 15 Oct 2009
Isolator, cracked
JOB 8723611 OPERATION 223/621 PRESSURE BULKHEAD FWD SIDE HAS TWO CRACKED ISOLATORS, ONE AT LBL 36 BELOW WL 97.50 AND ONE AT RBL 36 ABOVE WL 97.50.
- 14 Oct 2009
Floor Skin, cracked
FOUND FS 460 PRESSURE FLOOR SKIN HAS MULTIPLE INDCATIONS NOTED BETWEEN BL 0.0 AND RBL 9.0 1.5" IN LENGTH 60% FSH, FAILED NDT INSPECTION. AREAS MARKED ON…
- 12 Oct 2009
Intercostal, cracked
LEFT 621-625 OBLIQUE INTERCOSTAL IS CRACKED. REMOVED AND REPLACED LT 621-625 OBLIQUE INTERCOSTAL IAW SRM 51-42-21.
- 12 Oct 2009
Angle, cracked
RIGHT 621-625 OBLIQUE INTERCOSTAL IS CRACKED. REMOVED AND REPLACED RT 621-625 OBLIQUE INTERCOSTAL IAW SRM 51-42-21.
- 12 Oct 2009
Door, no test
PASSENGER DOOR FAILED FUNCTIONAL TEST DOOR FALLS TO FAST.
- 7 Jul 2009
Frame, cracked
FRAME AT FS 319.00 FROM STR 0 TO STR 4R IS CRACKED. REMOVED DAMAGED FROM IAW SRM 51-42-06. INSTALLED NEW SERVICEABLE FRAME IAW SRM 51-42-06 AND 51-42-21 AND…
- 28 Feb 2009
Unknown, fire
WITH AC EXTERNAL SELECTED ON BATT BUS, CAPT AND F/O ON BOARD PERFORMING PRE FLT DUTIES, OBSERVED A RUSHING AIR SOUND, COCKPIT AND FED CABIN QUICKLY FILLED…
- 11 Feb 2009
Step, cracked
ASD LOWER STEP CRACKED.
- 30 Dec 2008
Fitting, cracked
RELEVANT INDICATIONS OF CRACKS NOTED AROUND THE LINTEL ATTACHMENT FITTING ON THE AFT PRESSUR BULKHEAD. CRACKS MIGRATE APPROXIMATELY 3/16" FROM THE UPPER,…
- 8 Apr 2008
Light, broken
EMERGENCY LIGHT AT PAX DOOR BROKEN.
- 28 Jan 2008
Autopilot Sys, malfunctioned
STAB TRIM / MACH TRIM / AP ND CAUT MSG ON ARRIVAL INTO COLUMBIA. EMERGENCY DECLARED & EMERGENCY EQUIPMENT ON STANDBY AS A PRECAUTION. AUTOPILOT SYSTEM.
- 9 Nov 2007
Flashlight, inoperative
F/A FLASHLIGHT IS INOP.
- 5 Apr 2007
Skin, cracked
RANRC 390. LT BONDED SKIN COMMON TO FS 640.00 FRAME IS CRACKED. COMPLIED WITH LT BONDED SKIN FS 640 REPAIR, IAW EC/TC REO 601R-53-61-506 (JA10220/RA328)…
- 2 Apr 2007
Intercostal, cracked
RIGHT FS 484 INTERCOSTAL HAS CRACK IN CLIP AT RBL 27 IB. REMOVED CRACKED CLIP ON RT FS 484 INTERCOSTALS' AT RBL 27 AND DUPLICATED PER CRJ SRM 53-41-43 FIG. 1…
- 2 Apr 2007
Intercostal, cracked
LT FS 484 INTERCOSTAL HAS CRACK IN CLIP AT LBL 27 IB. REMOVED CRACKED CLIP FROM LT 484 INTERCOSTAL IAW CRJ 200 SRM 51-42-20. DUPLICATE CLIP FROM SALVAGE…
- 2 Apr 2007
Floor Support, corroded
FLOOR SUPPORT STRUCTURE BENEATH SERVICE DOOR THRESHOLD HAS MINOR SURFACE CORROSION. CORROSION FOUND TO BE LIMITED TO SURFACE ONLY AND NO PITTING WAS FOUND.…
- 29 Mar 2007
Angle, cracked
RIGHT OBLIQUE ANGLE AFT OF 621 BULKHEAD IS CRACKED (AS MARKED). REMOVED RT OBLIQUE ANGLE AFT OF621 BULKHEAD. OK TO TREAT AND PRIME RT OBLIQUE ANGLE AND PAINT.…
- 29 Mar 2007
Attach Angle, cracked
RIGHT WING I/B LEADING EDGE O/B ATTACH ANGLE CRACKED AT RADIUS. REMOVED AND REPLACED RT WING IB LE OB ATTACH ANGLE WITH NEW SERVICEABLE ANGLE P/N 600-12025-8…
- 29 Jan 2007
Unknown, unknown
NOSEWHEEL STEERING MESSAGE AFTER TAKEOFF. AIRCRAFT RETURNED TO MSN AFTER T/O. EMERGENCY DECLARED.
- 31 Dec 2006
Apu, shutdown
APU FAULT WITH AUTO SHUTDOWN. EN ROUTE TO MGM A/C DIVERTED TO BNA. EMERGENCY DECLARED. FLT 4727 CX ON 1-1-07 SEE DEFECT 334575A-2 FOR CX. AUXILIARY POWER UNIT…
- 19 Jun 2006
Step, broken
ASD LWR STEP BROKEN.
- 14 May 2006
Light, inoperative
ON WALK AROUND FOUND OVERWING EMERGANCY LIGHT'S FWD POSITION INOP. UPON FUTHER T/S FOUND BATTARY FOR FWD POSITION TO BE DEAD.
- 2 Jul 2005
Door, lack of lube
FLT 4455 - DURING A GROUND INSPECTION IN ATL, THE PASSENGER DOOR WAS FOUND EXTREMELY DIFFICULT TO OPEN. MAINTENANCE LUBRICATED THE PASSENGER DOOR. OPERATIONAL…
- 28 Jun 2005
Step, cracked
DURING A C-CHECK IN MCN, THE BOTTOM STEP ON THE PASSENGER DOOR WAS FOUND CRACKED. MAINTENANCE REMOVED AND REPLACED THE BOTTOM STEP ON THE PASSENGER DOOR.…
- 28 Jun 2005
Wire, broken
DURING A C-CHECK IN MCN, THE FORWARD EMERGENCY LIGHTS WOULD NOT ILLUMINATE. MAINTENANCE REPAIRED BROKEN WIRE ON THE FORWARD OVERHEAD CURVED EMERGENCY LIGHT…
- 12 Jun 2005
Frame, cracked
DURING A C-CHECK IN MCN, THE PILOT`S BULKHEAD FS 280 FRAME AT RBL 11 WAS FOUND TO BE CRACKED BEYOND LIMITS. MAINTENANCE IS REPAIRING THE PILOTS BULKHEAD FS…
- 11 Jun 2005
Angle, corroded
DURING A C-CHECK IN MCN, THE PASSENGER DOOR MIDDLE THRESHOLD ANGLE WAS FOUND TO BE CORRODED BEYOND LIMITS AND THE HOLES IN THE ANGLE WERE ELONGATED.…
- 11 Jun 2005
Clip, cracked
DURING A C-CHECK IN MCN, THE FS 484 LEFT INBOARD AND OUTBOARD CLIP ON THE PRESSURE FLOOR WAS FOUND TO BE CRACKED BEYOND LIMITS. MAINTENANCE REPAIRED THE FS…
- 10 Jun 2005
Intercostal, cracked
DURING A C-CHECK IN MCN, THE FS 484 INTERCOSTAL AT RBL 36 OUTBOARD WAS FOUND TO BE CRACKED BEYOND LIMITS. MAINTENANCE REPAIRED THE FS 484 INTERCOSTAL AT RBL…
- 10 Jun 2005
Sill, corroded
DURING A C-CHECK IN MCN, THE CARGO DOOR SILL WAS FOUND TO BE CORRODED BEYOND LIMITS. MAINTENANCE REPAIRED THE CARGO DOOR SILL IAW ASA EO 600-53-0117. (M)
- 10 Jun 2005
Sill, corroded
DURING A C-CHECK IN MCN, THE LEFT AND RIGHT FLOOR SILL ASSEMBLY, AROUND THE NUT PLATES, FINGER DOUBLERS, ATTACH ANGLES AND TRANSVERSE BEAMS, BETWEEN FS 424…
- 10 Jun 2005
Sill, corroded
DURING A C-CHECK IN MCN, THE FLOOR SILL AT FS 559 PLUS 16 TO FS 621 WAS FOUND TO BE CORRODED BEYOND LIMITS. MAINTENANCE REPAIRED THE FLOOR SILL AT FS 559 PLUS…
- 8 Jun 2005
Cover, cracked
DURING A C-CHECK IN MCN, THE FS 280 LT/RT CLIPS INBOARD AND OUTBOARD WERE FOUND TO BE CRACKED BEYOND LIMITS. MAINTENANCE REMOVED AND REPLACED THE FS 280 LT/RT…
- 7 Jun 2005
Cover, cracked
DURING A C-CHECK, THE EMERGENCY EXIT LIGHT LENS COVER ABOVE THE SERVICE DOOR WAS FOUND CRACKED. MAINTENANCE REMOVED AND REPLACED THE LENS COVER ON THE…
- 21 May 2005
Pseu, malfunctioned
DURING TAKEOFF FROM CVG-MSG, THE NOSE GEAR FAILED TO RETRACT AND A GEAR DISAGREE WARNING MESSAGE WAS RECEIVED. THE CREW LEVELED THE AIRCRAFT OFF AT 4,000 FEET…
- 10 Mar 2005
Step, broken
FLT 4213 - DURING A GROUND INSPECTION IN ATL, THE BOTTOM STEP ON THE PASSENGER DOOR WAS FOUND BROKEN. MAINTENANCE REMOVED AND REPLACED THE BOTTOM STEP ON THE…
- 2 Mar 2005
Step, cracked
DURING HANGAR MAINTENANCE IN MCN, THE TOP STEP ON THE PASSENGER DOOR WAS FOUND CRACKED AT BOTH OUTBOARD CORNERS. MAINTENANCE REMOVED AND REPLACED THE TOP STEP…
- 7 Jan 2005
Step, cracked
DURING AN A-CHECK, THE LOWER STEP ON THE PASSENGER DOOR WAS FOUND CRACKED. MAINTENANCE REMOVED AND REPLACED THE LOWER STEP ON THE PASSENGER DOOR.
- 12 Oct 2004
Lamp, burned out
DURING A GROUND INSPECTION, THE EMERGENCY EXIT LIGHT AT THE SERVICE DOOR WAS FOUND TO BE INOPERATIVE. MAINTENANCE REMOVED AND REPLACED THE EMERGENCY EXIT…
- 27 Sep 2004
Lamp, burned out
FLT 4219 - DURING A GROUND INSPECTION IN DFW, THE EMERGENCY LIGHT FORWARD OF THE PASSENGER DOOR WAS FOUND TO BE INOPERATIVE. MAINTENANCE REMOVED AND REPLACED…
- 19 Jul 2004
Connector, inoperative
DURING HANGAR MAINTENANCE IN BTR, THE EMERGENCY FLOOR LIGHTS AT ROWS ONE C/D TO FIVE C/D WERE FOUND TO BE INOPERATIVE. MAINTENANCE SECURED TO LOOSE CONNECTION…
- 4 Dec 2003
Floor Support, corroded
DURING A C-CHECK IN MCN, THE FLOOR SUPPORT ANGLE AT THE SERVICE DOOR ON THE RIGHT SIDE AT APPROXIMATELY FS 319 WAS FOUND TO BE CORRODED BEYOND LIMITS.…
- 4 Dec 2003
Floorbeam, corroded
DURING A C-CHECK IN MCN, THE PILOTS BULKHEAD FLOORBEAM AT FS 280, LBL 9.0 TO RBL 9.0 WAS FOUND TO BE CORRODED BEYOND LIMITS. MAINTENANCE IS REPAIRING THE…
- 4 Dec 2003
Sill, corroded
DURING A C-CHECK IN MCN, THE FLOOR SILL AT FS 349 TO FS 364 ON THE RIGHT SIDE WAS FOUND TO BE CORRODED BEYOND LIMITS. MAINTENANCE IS REPAIRING THE FLOOR SILL…
- 3 Dec 2003
Skin, cracked
DURING A C-CHECK IN MCN, THE NOSE LANDING GEAR CUTOUT ON THE LEFT AND RIGHT SIDES AT FS 235 WAS FOUND TO BE CRACKED BEYOND LIMITS. MAINTENANCE REPAIRED THE…
- 1 Dec 2003
Support Beam, cracked
DURING A C-CHECK IN MCN, THE CENTER ENGINE SUPPORT BEAM UPPER AND LOWER WEB AT BL 0 WAS FOUND CRACKED BEYOND LIMITS. MAINTENANCE IS REPAIRING THE CENTER…
- 1 Dec 2003
Floor Support, cracked
DURING A C-CHECK IN MCN, THE CARGO AFT WALL FLOOR SUPPORT ANGLES AT FS 621 ON THE LEFT AND RIGHT SIDES WERE FOUND TO BE CRACKED BEYOND LIMITS. MAINTENANCE IS…
- 5 Nov 2003
Step, cracked
DURING HANGAR MAINTENANCE IN MCN, THE PASSENGER DOOR BOTTOM STEP WAS FOUND CRACKED. MAINTENANCE REMOVED AND REPLACED THE PASSENGER DOOR BOTTOM STEP. OPS…
- 8 Apr 2003
Acm, odor
DURING TAKEOFF AND LANDING FROM DFW-RDU, THE RIGHT PACK BECAME UNCONTROLLABLE IN AUTOMATIC OR MANUAL MODES AND SHOWED 17 PSI IN THE RIGHT TENTH STAGE ONLY. A…
- 12 Dec 2001
Light, inoperative
DURING HANGAR INSPECTION IN XNA, THE RIGHT FORWARD EMERGENCY LIGHT WAS INOPERATIVE. MAINTENANCE REMOVED AND REPLACED THE BLOWN RIGHT FORWARD EMERGENCY LIGHT.…
- 1 Jul 2000
Line, failed
FLT 4690 - CREW REPORTED THAT HYDRAULIC SYSTEM NR 1 SYNOPTIC PAGE SHOWS ZERO QUANTITY. HYDRAULIC QUANTITY THEN FLUCTUATED BETWEEN 2600-2900 PSI. HYDRAUCLI…
- 9 Sep 1999
Emerg Battery, discharged
DURING DAILY INSPECTION, FOUND EMERGENCY BATTERY PACK INOPERATIVE. MAINTENANCE REPLACED EMERGENCY LIGHTING BATTERY PACK. OPERATIONAL CHECKS WERE GOOD.…
- 3 Feb 1999
Windshield, cracked
DTW/ATL - FLT 4630 - DURING DESCENT AT 12,800 FEET AND 280 KNOTS, THE LEFT WINDSHIELD CRACKED. CREW DECLARED AN EMERGENCY AND LANDED IN ATL WITHOUT FURTHER…