- 2 Oct 2026
Hydraulic System, warning message
FLT#1450, STI-FLL. LOST HYDRAULICS ON THE GREEN SYSTEM- ECAM MSGS THAT FOLLOWED WERE G RSVR LO LVL, G ENG 1 PUMP LO PR. TURNED OFF PUMP 1 MIN AFTEER ECAM MSGS…
- 27 Aug 2026
Contactor, faulted
FLT 552, MCO-MCO. ELEC AC ESS FEED FAULT AT APPROX 60 KTS DURING TO. FLICKERED AND THEN LOST SCREENS 1, 2, 3 AT APPROX 70 KTS, EXECUTED AN RTO; R & R ACCESS…
- 8 Apr 2026
Unknown, odor
FLT# 2475, BDL-SJU. "LEAVING 35000 FT STRONG OIL SMELL COMPLIED WITH PROCEDURE AND SHUT OFF PACK 1 AND SHUT VALVE AFTER 3MINS WE RETURNED EVERYTHING BACK ON…
- 9 Feb 2026
Unknown, odor
FLT 1199, LGA - MCO. ON DESCENT THROUGH 15000 FT. STRONG ODOR IN COCKPIT, MAGIC MARKER & OILY. COMPLIED WITH INFORMATION NOTICE 2017-T015, STEPS 1 AND 2.…
- 28 Jan 2026
None, none
FLT 851, BOS-MCO. INFLIGHT REPOERTED A CHAMICAL ODOR WAS BURNING EYES, PILOTS DID NOT PERCEIVE ANY ODOR. ODOR WAS STRONGER IN THE FRONT OF THE AIRCRAFT AND…
- 20 Dec 2024
A/C Pack, faulted
FLT#1794, SJO-JFK.; (AIRCRAFT DIVERTED TO FLL AND DECLARED AN EMERGENCY) ' DURING CRUISE CHECKS NOTED PACK 2 INLET VALVE APPEARED CLOSED AND PACK 1 OPERATING…
- 7 Nov 2024
Entertain Sys, corroded
FLT#2476,SJU-BDL. ' IFE INOP ( THALES AVANT IFE (ENTIRE SYSTEM) ) - TV 1 A FLICKERED OFF. A SMELL OF ELECTRIAL FIRE WAS OBSERVED BY INFLIGHT . THE WALL AROUND…
- 30 Aug 2024
Drive Assy, failed
FLT#1255, FLL-GYE. (AIRCRAFT PERFORMED AN AIR TURN BACK TO FLL) 'DURING CRUISE FLIGHT ON ND DISPLAY. -AMBER "WX WEAK" -RED "R/T FAULT" -TURNED RADAR OFF THEN…
- 22 May 2024
Support, corroded
DURING HEAVY MAINTENANCE: CORROSION LOWER SILL LOC. BTW FR66/FR68 AT LEVEL STR23R AFT GALLEY ARE A (1 EA) (CPCP FINDING); (RESOLVED ON W/O: 1291498 TASKCARD:…
- 22 May 2024
Support, corroded
DURING HEAVY MAINTENANCE: CORROSION LOWER SILL LOC. BTW FR66/FR68 AT LEVEL STR23L AFT GALLEY ARE A (1 EA) (CPCP FINDING); PERFORMED PERMANENT REPAIR ON LOWER…
- 22 May 2024
Angle, corroded
DURING HEAVY MAINTENANCE: CORROSION ANGLE WEB FLOOR STRUCTURE BTW FR69/FR70 STR23R AFT GALLEY AREA; REFERENCE AEROMAN W.O. 2024 110/1 NR 2024-249464 REMOVED…
- 22 May 2024
Angle, corroded
DURING HEAVY MAINTENANCE: CORROSION ANGLE WEB FLOOR STRUCTURE BTW FR69/FR70 AT LEVEL 23L AFT GALLEY AREA ( 1 EA ); (RESOLVED ON W/O: 1291498 TASKCARD:…
- 22 May 2024
Light, no test
DURING HEAVY MAINTENANCE: DONT PASS OPERATIONAL TEST EMERGENCY LIGHT THROUGH MCDU PASSENGER CREW DOOR 831 AT FWD GALLEY AREA; REMOVED AND REPLACED SLIDE RAFT…
- 11 Dec 2023
Unknown, unknown
FLT#794, AUS-JFK. 'PREVIOUS CREW STATED AIRCRAFT VIBRATION DURING CLIMB AND THEN DISIPATED. COMING FROM TAIL AREA. AIRCRAFT TEST FLIGHT DOES NOT SPECIFY…
- 16 Nov 2023
Unknown, unknown
FLT#788, SXM-JFK. (AIRCRAFT DIVERTED TO FLL) 'UPON CLIMBOUT OF SXM WE FELT A MEDIUM VIBRATION AFTER FLAP RETRACTION. THE VIBRATION CONTINUED ON CLIMBOUT TO…
- 20 Sep 2023
Unknown, unknown
FLT#1825, FLL-LIM. (AIRCRAFT DIVERTED TO MCO) 'POSSIBLE LIGHTNING STRIKE ON CLIMBOUT AT 8000'; ACCOMPLISHED LIGHTNING STRIKE INSPECTION IAW AMM…
- 4 May 2021
Unknown, odor
FLT# 1219, BOS-MIA. ODOR OCCURANCE OBSERVED @ TAKE OFF AND APPROACH SEE MX-270 ; C/W THE INFO NOTICE 2017-T015F SEE HOW A AC IS OK FOR SVC MCC MARIO WAS MADE…
- 29 Jan 2020
Battery, failed
FT # 662, BGI-JFK. ALL EPSU BATTERIES NEEDS REPLACEMENT PER T/C A320-33-51-00-710-003 WO 1038894; R & R ALL EPSU BATTERIES IAW AMM 33-51-38. OPS CHK NORMAL.
- 29 Jan 2020
Battery, no test
FT # 662, BGI-JFK. ALL EPSU BATTERIES NEEDS REPLACEMENT PER T/C A320-33-51-00-710-003 WO 1038894; R & R ALL EPSU BATTERIES IAW AMM 33-51-38. OPS CHK NORMAL.
- 29 Jan 2020
Battery, failed
FT # 662, BGI-JFK. ALL EPSU BATTERIES NEEDS REPLACEMENT PER T/C A320-33-51-00-710-003 WO 1038894; R & R ALL EPSU BATTERIES IAW AMM 33-51-38. OPS CHK NORMAL.
- 30 May 2019
Unknown, odor
FT # 1926, DIRTY SOCK SMELL REPORTED BY FA'S 1,2, & 3 AFTER SHUTDOWN AT GATE. ODOR PRESENT ITSELF DURING FINAL DESCENT. NOTICED BY FLIGHT CREW AS WELL. FA'S…
- 8 May 2019
Ecs, contaminated
FLT 1500, HAV-FLL. ON DESCENT CREW REPORTED DIRTY SOCK SMELL FOR ABOUT 10 MINUTES. SMELL WAS MORE PRONOUNCED IN THE REAR OF THE AIRCRAFT REPEAT GRIPE;…
- 7 May 2019
Unknown, odor
FLT 1499, FLL-HAV. FLIGHT ATTENDANTS REPORTED A SOUR MILK DIRTY SOCK ODOR DURING THE LAST 25 MINUTES OF FLIGHT. THE ODOR PERSISTED THROUGH OUT THE ENTIRE…
- 3 Mar 2019
Unknown, odor
FLT 803, JFK-SJU. HAD CABIN ODOR SCENT (LIKE DIRTY DIAPER SMELL) HALF WAY THROUGH DESCENT TILL TOUCHDOWN. SMELL WAS THROUGH OUT CABIN; COMPLIED WITH INFO…
- 7 Apr 2018
Lanyard, broken
R2 DOOR SLIDE WRAPPING IS COMING LOOSE, FOUND BROKEN TIE CORDS. REPLACED R2 DOOR SLIDE IAW AMM 25-62-44-400-803-H.
- 7 Apr 2018
Light, disconnected
DURING HEAVY MAINTENANCE, CEILING MOUNTED EMERGENCY EXIT LIGHT AT SEAT ROW 5 IS INOPERATIVE. CONNECTED THE LIGHT IAW AMM 33-51-11-420-050-H, OPS TESTED OK IAW…
- 26 Sep 2017
Servo, failed
LIGHT AIRFRAME VIBRATION DURING CLIMB, FL190 TO FL230. FELT IN COCKPIT ONLY. STOPPED IN TURN, STARTED AGAIN AT WINGS LEVEL. SIMILAR ON DESCENT. DIVERTED,…
- 26 Sep 2017
Servo Valve, failed
LIGHT AIRFRAME VIBRATION DURING CLIMB, FL190 TO FL230. FELT IN COCKPIT ONLY. STOPPED IN TURN, STARTED AGAIN AT WINGS LEVEL. SIMILAR ON DESCENT. DIVERTED,…
- 17 Sep 2017
Unknown, odor
DIRTY SOCK ODOR, FROM TOP OF DESCENT AT FL 360 TO MID TEENS. STRONGEST ODOR WAS IN THE 20'S WITH POWER IDLE, NR 1 ENGINE CHANGED LAST WEEK, NO HISTORY SINCE.…
- 4 Sep 2017
Engine, failed
CABIN ODOR AT LEVEL OFF, 4000 FT, HP BLEEDS OPEN AND THRUST NOT AT IDLE ,DIRTY SOCK ODOR BECAME STRONG AND WAS DISAPATED AFTER PACK 1 TURNED OFF. VERIFIED…
- 2 Sep 2017
A/C Pack, contaminated
DIRTY SOCK ODOR ON DEPARTURE BEFORE THRUST REDUCTION ODOR DISSIPATED QUICKLY, THEREAFTER THE ODOR RETURNED ON DESCENT AT FL 290 RECEIVED STRONGER AT FL 200…
- 29 Aug 2017
Water Heater, odor
CABIN CREW DESCRIBES SMELLING AN ODOR LIKE BURNING PLASTIC. ODOR STARTED AROUND 10000 ON DESCENT. CREW HAD A BUNING THROAT AND DIZZINESS . DID NOT DETECT ANY…
- 26 Aug 2017
Condenser, malfunctioned
FLT 402, FLL-JFK. DIRTY SOCK/ OIL ODOR DETECTED. ODOR ORIGINATED AT ROTATION AND PERSISTED THROUGH 22,000 FT ODOR ONLY DETECTED IN COCKPIT. ODOR OCCURRED…
- 26 Aug 2017
Filter, dirty
FLT 402, FLL-JFK. DIRTY SOCK/ OIL ODOR DETECTED. ODOR ORIGINATED AT ROTATION AND PERSISTED THROUGH 22,000 FT ODOR ONLY DETECTED IN COCKPIT. ODOR OCCURRED…
- 26 Aug 2017
Filter, dirty
FLT 402, FLL-JFK. DIRTY SOCK/ OIL ODOR DETECTED. ODOR ORIGINATED AT ROTATION AND PERSISTED THROUGH 22,000 FT ODOR ONLY DETECTED IN COCKPIT. ODOR OCCURRED…
- 24 Aug 2017
Oil System, overserviced
CABIN ODOR MUSTY ODOR OCCURRED IMMEDIATELY AFTER TAKE OFF AND LASTED UNTIL ABOUT 10,000 FT ON CLIMBOUT. OCCURRED AGAIN ON DESCENT WHEN LEVEL AT 6000FT, STRONG…
- 24 Aug 2017
A/C Pack, odor
MUSTY, OILY, DIRTY SOCK ODOR AFTER TAKEOFF, AND DESCENT, UNTIL 15,000 - 18,000 FT. THE ODOR WAS ISOLATED TO COCKPIT AREA. ODOR DISSIPATES WHEN PACK NR 1 OFF.…
- 19 Aug 2017
Actuator, leaking
A MUSTY ODOR DURING DESCENT. AN APU TEST DUPLICATED FAULT. ACCOMP TSM 49-00-81-810. FOUND APU OIL LEVEL OVERSERVICED. REPLENISH LEVEL IAW AMM 49-00-00. ALSO…
- 21 Jul 2017
Cabin Air Sys, contaminated
DURING APPROACH AT 2200 FT, POWER ADVANCED AFTER BEING AT IDLE FROM CRUISE ALTITUDE, A STRONG MILDEW. DIRTY SOCK ODOR OBSERVED IN FLIGHT DECK AND IN CABIN FWD…
- 21 Jul 2017
Filter, odor
DURING APPROACH AT 2200 FT, POWER ADVANCED AFTER BEING AT IDLE FROM CRUISE ALTITUDE, STRONG MILDEW. DIRTY SOCK ODOR OBSERVED ON FLIGHT DECK AND IN CABIN FWD…
- 21 Jun 2017
Oil System, overserviced
PASSING 8000 FT DURING DESCENT, A STRONG ODOR OF OIL. NO APU AT THE TIME AT SHUT DOWN. TRANSFERED ACFT TO APU AND ODOR PRODUCED AGAIN. PERFORMED TSM 05-50-00.…
- 21 Jun 2017
Oil System, overserviced
SUPPLEMENTAL INFORMATION (WORD CORRECTION, "NORTH1" TO "NOTCH1"): FLT 1579, DCA-FLL. PASSING 8000 IN DESCENT STRONG ODOR OF OIL. NO APU AT THE TIME AT SHUT…
- 1 Jun 2017
Unknown, odor
DIRTY SOCK ODOR DURING DESCENT, NO APU RUNNING. ACCOMPLISHED CHAPTER 5 TSM INSPECTION IAW TSM 05-50-00-810-831-A. R & R THE LT & RT OZONE FILTERS AS A…
- 1 Jun 2017
Unknown, odor
DIRTY SOCK ODOR ON DESCENT NO APU RUNNING. (PRETTY STRONG); ACCOMPLISHED CHAP. 5 TSM INSP. PER TSM 05-50-00-810-831-A. COS FOUND TO BE TYPE 3. R & R LH + RH…
- 2 Apr 2017
Battery Pack, no test
DURING EMERGENCY LIGHT TEST, THE EPSU BATTERIES FOR FWD AND AFT, FAULTED. R & R FWD AND AFT EPSU BATTERIES IAW AMM 33-51-38. OPS CHECKED GOOD.
- 2 Apr 2017
Battery Pack, no test
DURING AN EMERGENCY LIGHT TEST, THE EPSU BATTERIES FOR FWD AND AFT, FAULTED. R & R THE FWD AND AFT EPSU BATTERIES IAW AMM 33-51-38. OPS CHECKED GOOD.