N824AW
2001 Airbus Industrie A319-132 standard FAA →
registration
- 2001
service difficulty reports
227 reports
- 4 Apr 2026
Battery, inoperative
AIRCRAFT WAS NOT GROUNDED: ESPU EMER L FAULT. MAINTENANCE REPLACED LH EPSU BATTERY IAW AMM 33-51-38. NO FURTHER DEFECTS NOTED AT THIS TIME.
- 4 Apr 2026
Power Supply, faulted
AIRCRAFT WAS NOT GROUNDED: ESPU EMER R FAULT. MAINTENANCE REPLACED POWER SUPPLY UNIT AND EMERGENCY BATTERY IAW AMM 33-51-38.
- 24 Feb 2026
Battery, no test
AIRCRAFT WAS NOT GROUNDED: MAJORITY OF THE EMERGENCY CABIN LIGHTS INOPERATIVE. (ONLY THE BACK EMERGENCY LIGHTS PARTIALLY WORK) REPLACED FORWARD EMERGENCY…
- 27 Oct 2025
Eiu, faulted
AIRCRAFT WAS GROUNDED: NUMBER 2 ENGINE SHOWED LOW PSI OCCASIONALLY DROPPING TO 0. AS PE,R CHECKLIST ALL OTHER INDICATIONS WERE NORMAL. DECESION MADE TO DIVERT…
- 10 Oct 2025
Flashlight, inoperative
AIRCRAFT WAS NOT GROUNDED: FLIGHT ATTENDANTS REPORT AFT FLASHLIGHT UNDER JUMPSEAT NOT FLASHING, NEEDS TO BE REPLACED. MAINTENANCE REPLACED FA FLASH LIGHT IAW…
- 4 Sep 2025
Attach Bolt, corroded
AIRCRAFT IN BASE MAINTENANCE: CORROSION BOLT ATTATCHMENT SLAT TRACK 2 LOWER BOLT ON RH WING, STA1406 RIB 3 (CPCP 574202-01) L=0.375 INCH W=0.282 INCH D=0.006…
- 30 Aug 2025
Light, burned
AIRCRAFT IN BASE MAINTENANCE: BURN EMERGENCY LIGHT ASSY ON FWD CLOSET LH. MAINTENANCE REPLACED EMERGENCY LIGHT ASSY ON FWD CLOSET LH IAW AMM…
- 19 Aug 2025
Bottle, no test
AIRCRAFT IN BASE MAINTENANCE: DONT PASS OPERATIONAL TEST DAMPING FUNCTION OF THE DOOR DAMPER AND EME RGENCY OPERATION CYLINDER PASSENGER CREW DOOR 831 AT FWD…
- 24 Jul 2025
Stringer, corroded
AIRCRAFT IN BASE MAINTENANCE: CORROSION STRINGER 31 R BTW FR 65 TO FR 66 IN BULK CARGO COMPARTMENT MEASURE OF CORROSION ARE L: 3.990 INCH, W: 0.873 INCH, D:…
- 17 Jul 2025
Fitting, corroded
AIRCRAFT IN BASE MAINTENANCE: CORROSION CENTER FITTING LOCATED BTW FR 66 AND FR 68 AT LEVEL OF STR 23L AFT GALLEY AREA L=1.780 INCH W=0.130 INCH D=0.015 INCH.…
- 17 Jul 2025
Shear Plate, cracked
AIRCRAFT IN BASE MAINTENANCE: CRACK SHEAR PLATE AT STR23L BETWEEN FR69-FR70 AFT GALLEY AREA. CRACK L= 1.031 IN. MAINTENANCE REPLACED SHEAR PLAET AT STR 23L…
- 17 Jul 2025
Shear Plate, cracked
AIRCRAFT IN BASE MAINTENANCE: CRACK SHEAR PLATE STR 23 R BTW FR69 AND FR70 AT AFT GALLEY AREA MEASURE CRACK IS L=0.500 INCH. MAINTENANCE REPLACED SHEAR PLATE…
- 15 Jul 2025
Hinge Fitting, excess play
AIRCRAFT IN BASE MAINTENANCE: EXCESSIVE PLAY ELEVATOR HINGE ARM 2 ON RH HORIZONTAL STABILIZER. MAINTENANCE REPLACED ELEVATOR HINGE ARM END FITTING #2 ON RH…
- 15 Jul 2025
Hinge Fitting, excess play
AIRCRAFT IN BASE MAINTENANCE: EXCESSIVE PLAY ELEVATOR HINGE ARM 4 ON RH HORIZONTAL STABILIZER. MAINTENANCE REPLACED ELEVATOR HINGE ARM END FITTING # 4 ON RH…
- 15 Jul 2025
Hinge Fitting, excess play
AIRCRAFT IN BASE MAINTENANCE: EXCESSIVE PLAY ELEVATOR HINGE ARM 1 ON RH HORIZONTAL STABILIZER. MAINTENANCE REPLACED ELEVATOR HINGE ARM END FITTING #1 ON RH…
- 15 Jul 2025
Hinge Fitting, excess play
AIRCRAFT IN BASE MAINTENANCE: EXCESSIVE PLAY ELEVATOR HINGE ARM 3 ON RH HORIZONTAL STABILIZER. MAINTENANCE REPLACED ELEVATOR HINGE ARM END FITTING #3 ON RH…
- 15 Jul 2025
Hinge Fitting, excess play
AIRCRAFT IN BASE MAINTENANCE: EXCESSIVE PLAY ELEVATOR HINGE ARM 5 ON RH HORIZONTAL STABILIZER. MAINTENANCE REPLACED ELEVATOR HINGE ARM END FITTING #5 ON RH…
- 15 Jul 2025
Hinge Fitting, excess play
AIRCRAFT IN BASE MAINTENANCE: EXCESSIVE PLAY ELEVATOR HINGE ARM 6 ON RH HORIZONTAL STABILIZER. MAINTENANCE REPLACED ELEVATOR HINGE ARM END FITTING #6 ON RH…
- 15 Jul 2025
Hinge Fitting, excess play
AIRCRAFT IN BASE MAINTENANCE: EXCESSIVE PLAY ELEVATOR HINGE ARM 4 ON LH HORIZONTAL STABILIZER. MAINTENANCE REPLACED ELEVATOR HINGE ARM END FITTING #4 ON LH…
- 15 Jul 2025
Hinge Fitting, excess play
AIRCRAFT IN BASE MAINTENANCE: EXCESSIVE PLAY ELEVATOR HINGE ARM 1 ON LH HORIZONTAL STABILIZER. MAINTENANCE REPLACED ELEVATOR HINGE ARM END FITTING #1 ON LH…
- 15 Jul 2025
Hinge Fitting, excess play
AIRCRAFT IN BASE MAINTENANCE: EXCESSIVE PLAY ELEVATOR HINGE ARM 3 ON LH HORIZONTAL STABILIZER. MAINTENANCE REPLACED ELEVATOR HINGE ARM END FITTING #3 ON LH…
- 15 Jul 2025
Hinge Fitting, excess play
AIRCRAFT IN BASE MAINTENANCE: EXCESSIVE PLAY ELEVATOR HINGE ARM 2 ON LH HORIZONTAL STABILIZER. MAINTENANCE REPLACED ELEVATOR HINGE ARM END FITTING #2 ON LH…
- 15 Jul 2025
Hinge Fitting, excess play
AIRCRAFT IN BASE MAINTENANCE: EXCESSIVE PLAY ELEVATOR HINGE ARM 5 ON LH HORIZONTAL STABILIZER. MAINTENANCE REPLACED ELEVATOR HINGE ARM END FITTING #5 ON LH…
- 15 Jul 2025
Hinge Arm, excess play
AIRCRAFT IN BASE MAINTENANCE: EXCESSIVE PLAY ELEVATOR HINGE ARM 6 ON LH HORIZONTAL STABILIZER. MAINTENANCE REPLACED ELEVATOR HINGE ARM 6 ON LH HORIZONTAL…
- 15 Jul 2025
Light, burned out
AIRCRAFT IN BASE MAINTENANCE: BURN EMERGENCY LIGHT ASSY ON WALL OF LAVATORY D. MAINTENANCE REPLACED EMERGENCY LIGHT ASSY ON WALL OF LAVATORY D IAW AMM…
- 12 Jul 2025
Fitting, cracked
AIRCRAFT IN BASE MAINTENANCE: CRACK INDICATION FOUND ON CONTINUITY FITTING OF WINDSHIELD LOWER ATTACHMENT AREA RH INTERNAL SIDE. CRACK L= 0.200 INCH.…
- 5 Jun 2025
Wire Harness, inoperative
AIRCRAFT WAS GROUNDED: SEAT 11 ABC AND 12 ABC EMERGENCY LIGHTS ARE OUT. MAINTENANCE REPLACED WIRE HARNESS 8008-40-45-0 BETWEEN ROWS 11 AND 12 ABC IAW AWM…
- 26 Mar 2024
Light, disconnected
AIRCRAFT WAS NOT GROUNDED: ROW 16 ABC PATH EMERGENCY LIGHT INOPERATIVE. RECONNECT ROW 16 ABC PATH LIGHT.
- 26 Mar 2024
Light, faulty
AIRCRAFT WAS NOT GROUNDED: RIGHT HAND EXIT ROW LIGHT IS HALF ILLUMINATED. REPLACED RIGHT HAND EXIT ROW LIGHT.
- 26 Mar 2024
Light, inoperative
AIRCRAFT WAS NOT GROUNDED: FORWARD EXIT ROW CEILING LIGHT IS NOT ILLUMINATING. REMOVED AND REPLACED FORWARD EXIT ROW EMERGENCY LIGHT PER AMM 33-51-16.
- 18 Feb 2024
Slide, low pressure
AIRCRAFT WAS GROUNDED: 2L SLIDE PRESSURE APPEARS TO BE BELOW GREEN BAND. REMOVED AND REPLACED SLIDE PACK ASSEMBLY AND DAMAGED BUSTLE.
- 22 Jan 2024
Warning Message, illuminated
AIRCRAFT WAS NOT GROUNDED: AN EMERGENCY WAS DECLARED AND THE AIRCRAFT RETURNED TO PHL DUE TO AN AFT CARGO DOOR ECAM INDICATION DURING CLIMB. THE AIRCRAFT…
- 22 Jan 2024
Proximity Sensor, defective
AIRCRAFT WAS NOT GROUNDED: AN EMERGENCY WAS DECLARED AND THE AIRCRAFT RETURNED TO PHL DUE TO AN AFT CARGO DOOR ECAM INDICATION DURING CLIMB. THE AIRCRAFT…
- 30 Dec 2023
Light, no test
AIRCRAFT WAS NOT GROUNDED: WHILE PROFORMING OPERATIONAL TEST OF THE EMERGENCY LIGHTING SYSTEM DURING ROUTINE JOB CARD 26L00025010, FOUND EMERGENCY POWER…
- 30 Dec 2023
Sign, no test
AIRCRAFT WAS NOT GROUNDED: WHILE PROFORMING OPERATIONAL TEST OF THE EMERGENCY LIGHTING SYSTEM DURING ROUTINE JOB CARD 26L00025010, FOUND EMERGENCY POWER…
- 7 Mar 2023
Bracket, cracked
AIRCRAFT IN BASE MAINTENANCE: 80VU RACK CENTER STANCHION HAS A CRACKED BRACKET. MAINTENANCE REPLACED BRACKET PER SRM 51-42-11.
- 30 Jan 2023
Bulb, inoperative
AIRCRAFT WAS NOT GROUNDED: NUMEROUS BLUBS OUT IN EMERGENCY EXIT LIGHTS. MAINTENANCE REPLACED NUMEROUS BULBS IN EMERGENCY EXIT LIGHT SIGN PER AMM 33-51-11 AND…
- 7 Aug 2022
Lgciu, faulty
AIRCRAFT WAS GROUNDED: AFTER TAKEOFF FLIGHT ATTENDANTS NOTED A BURNING SMELL IN THE CABIN AS THE ECAM GAVE US A LANDING GEAR, CONTROL INTERFACE UNIT 1 FAULT.…
- 4 Mar 2022
Smoke Detector, false activation
AIRCRAFT WAS NOT GROUNDED: SMOKE/LAV WARNING IN FLIGHT. THE FLIGHT ATTENDANTS SAID THE ORANGE LIGHT WAS ILLUMINATED OUTSIDE THE AFT LAV NO INDICATIONS OF…
- 6 Nov 2021
Light, burned out
AIRCRAFT WAS NOT GROUNDED: ROW 14 AIRCRAFT EMERGENCY EXIT SIGN AIRCRAFT RIGHT BURNED OUT. REMOVED AND REPLACED LIGHT ASSEMBLY PER AMM 35-21-11.
- 27 Oct 2021
Fitting, worn
AIRCRAFT IN BASE MAINTENANCE: RIGHT FORWARD BEAM FITTING MAIN LANDING GEAR DOOR ACTUATOR AFT LUG BUSHING MIGRATED AND FITTING BORE WORN BEYOND LIMITS.…
- 25 Oct 2021
Fitting, worn
AIRCRAFT IN BASE MAINTENANCE: RIGHT HAND MAIN LANDING GEAR DOOR ACTUATOR FITTING AT KEEL BEAM AFT LUG BORE WORN. REPLACED FITTING PER EA 331565.NOTE: THIS…
- 11 Oct 2021
Lamp, inoperative
AIRCRAFT WAS NOT GROUNDED: LAVATORY E DOME/EMERGENCY LIGHT INOPERATIVE. RELAMPED LIGHT AND ACCOMPLISHED A SATISFACTORY OPERATIONAL CHECK.
- 23 Sep 2021
Housing, detached
AIRCRAFT WAS NOT GROUNDED: EMERGENCY LIGHT UNDER SEAT 27C HANGING LOOSE. REPLACED LIGHT HOUSING PER CMM 25-22-52.
- 6 May 2021
Skin, corroded
AIRCRAFT WAS GROUNDED: LAVATORY VENT EXTERNAL CORROSION FOUND. REPAIRED EXTERNAL SKIN PANEL AT LAVATORY VENT PER EA 327494.
- 4 May 2021
Skin, corroded
AIRCRAFT WAS GROUNDED: CORROSION ON RIGHT HAND AFT FUSELAGE SKIN PANEL AT LAVATORY EXHAUST OUTLET BETWEEN FR69 AND FR70, S31R AND S32R. ACCOMPLISHED REPAIR…
- 19 Feb 2021
Pintle Pin, corroded
AIRCRAFT WAS GROUNDED: LEFT MAIN LANDING GEAR AFT PINTLE PIN HAS CORROSION. INSTALLED NEW AFT PINTLE PIN REF JOB CARD 26T00032001 STEP 26.
- 19 Feb 2021
Pintle Pin, corroded
AIRCRAFT WAS GROUNDED: RIGHT MAIN LANDING GEAR PINTLE PIN HAS EXCESSIVE WEAR MARKS AND CORROSION. INSTALLED AFT PINTLE PIN REF JOB CARD 26T00032001 STEP 26.
- 5 Dec 2020
Lamp, inoperative
AIRCRAFT WAS GROUNDED. EXIT SIGN AT 53WL HAS MULTIPLE LAMPS INOPERATIVE. RELAMPED EMERGENCY LIGHT AT 53WL, PER AMM 33-51-17.
- 5 Dec 2020
Lamp, inoperative
AIRCRAFT WAS GROUNDED. CABIN EMERGENCY LIGHT AT 20WL HAS MULTIPLE LAMPS INOPERATIVE. RELAMPED EMERGENCY LIGHT AT 20WL, PER AMM 33-51-11.
- 5 Dec 2020
Lamp, inoperative
AIRCRAFT WAS GROUNDED. CABIN EMERGENCY LIGHT AT 21WL HAS MULTIPLE LAMPS INOPERATIVE. RELAMPED EMERGENCY LIGHT AT 21WL, PER AMM 33-51-11.
- 5 Dec 2020
Lamp, inoperative
AIRCRAFT WAS GROUNDED. EXIT LOCATION SIGN AT 51WL HAS MULTIPLE LAMPS INOPERATIVE. RELAMPED EMERGENCY LIGHT AT 51WL, PER AMM 33-51-17.
- 7 Nov 2020
Switch, worn
AIRCRAFT WAS GROUNDED. EMERGENCY EXIT LIGHT TOGGLE WORN. WILL NOT STAY IN DE-TENT. REMOVED AND REPLACED EMERGENCY EXIT LIGHT TOGGLE SWITCH, PER ESPW 20-53-50.
- 20 Sep 2020
Lever, loose
AIRCRAFT NOT GROUNDED: L1 DOOR, SLIDE ARM LEVER LOOSE. SECURED HARDWARE, SLIDE ARM LEVER L1 DOOR, AMM 52-11-00. OPERATION NORMAL.
- 27 Apr 2020
Hinge Fitting, worn
AIRCRAFT IN BASE MAINTENANCE: RIGHT ELEVATOR # 2 HINGE HAS EXCESSIVE PLAY / WEAR ON THE RIGHT HAND HORIZONTAL STABILIZER. REPLACED HINGE FITTING PER AMM…
- 27 Apr 2020
Hinge Fitting, worn
AIRCRAFT IN BASE MAINTENANCE: RIGHT ELEVATOR # 3 HINGE HAS EXCESSIVE PLAY / WEAR ON THE RIGHT HAND HORIZONTAL STABILIZER. REPLACED HINGE FITTING PER AMM…
- 24 Apr 2020
Anchor Fitting, corroded
AIRCRAFT IN BASE MAINTENANCE: CORROSION ON LEFT MAIN LANGING GEAR RETRACTION JACK ANCHORAGE FITTING BETWEEN WS70 TO WS 141 AND BETWEEN RIB 2 TO RIB 3.…
- 23 Apr 2020
Hinge Fitting, worn
AIRCRAFT IN BASE MAINTENANCE: RIGHT ELEVATOR # 1 HINGE HAS EXCESSIVE PLAY / WEAR ON THE RIGHT HAND HORIZONTAL STABILIZER. REPLACED HINGE FITTING PER AMM…
- 23 Apr 2020
Hinge Fitting, worn
AIRCRAFT IN BASE MAINTENANCE: RIGHT ELEVATOR # 4 HINGE HAS EXCESSIVE PLAY / WEAR ON THE RIGHT HAND HORIZONTAL STABILIZER. REPLACED HINGE FITTING PER AMM…
- 23 Apr 2020
Hinge Fitting, worn
AIRCRAFT IN BASE MAINTENANCE: RIGHT ELEVATOR # 5 HINGE HAS EXCESSIVE PLAY / WEAR ON THE RIGHT HAND HORIZONTAL STABILIZER. REPLACED HINGE FITTING PER AMM…
- 23 Apr 2020
Hinge Fitting, worn
AIRCRAFT IN BASE MAINTENANCE: RIGHT ELEVATOR # 6 HINGE HAS EXCESSIVE PLAY / WEAR ON THE RIGHT HAND HORIZONTAL STABILIZER. REPLACED HINGE FITTING PER AMM…
- 23 Apr 2020
Attach Bracket, cracked
AIRCRAFT IN BASE MAINTENANCE: CRACK ON FORWARD CARGO COMPARTMENT DOOR ACTUATOR ATTACH BRACKETS LOCATED BTW FR 25 TO FR 27. REPLACED BRACKETS PER…
- 22 Apr 2020
Bolt, corroded
AIRCRAFT IN BASE MAINTENANCE: CORROSION ON LEFT WING SLAT TRACK # 3 FORWARD BOLT AT WING STATION 2580, RIB # 5. INSTALLED MODIFIED BOLT PER AMM 27-84-63.
- 21 Apr 2020
Fitting, corroded
AIRCRAFT IN BASE MAINTENANCE: CORROSION ON MAIN LANDING GEAR RETRACTION ACTUATOR ATTACHMENT JACK FITTING / BRACKET UPPER AND LOWER SURFACES ON RIGHT HAND…
- 20 Apr 2020
Floor Panel, delaminated
AIRCRAFT IN BASE MAINTENANCE: DELAMINATED FLOOR PANEL 211EF IN THE COCKPIT. INSTALLED MODIFIED FLOOR PANEL PER SRM 53-12-00.
- 20 Apr 2020
Floor Panel, delaminated
AIRCRAFT IN BASE MAINTENANCE: DELAMINATION ON CABIN FLOOR PANEL # 242KF BETWEEN FR 42 TO FR 47 AND BETWEEN -Y254 TO -Y765. INSTALLED MODIFIED FLOOR PANEL PER…
- 20 Apr 2020
Floor Panel, delaminated
AIRCRAFT IN BASE MAINTENANCE: DELAMINATION ON CABIN FLOOR PANEL # 241KF BETWEEN FR 42 TO FR 47 AND BETWEEN Y254 TO Y765. INSTALLED MODIFIED FLOOR PANEL PER…
- 20 Apr 2020
Fitting, cracked
AIRCRAFT IN BASE MAINTENANCE: 0.88 INCH CRACK ON INTERCOSTAL FITTING AT FR 20 LEVEL WITH L1 DOOR STOP # 7. REPLACED INTERCOSTAL FITTING PER SRM 51-72-11.
- 19 Apr 2020
Bolt, corroded
CORROSION ON RIGHT HAND AILERON HINGE BOLT BETWEEN WING STATIONS 11664 TO 12277, AND RIB 22 TO RIB 23. REPLACED RIGHT HAND AILERON HINGE BOLT PER AMM…
- 15 Apr 2020
Fitting, cracked
AIRCRAFT IN BASE MAINTENANCE: CRACK AT UPPER INBOARD FASTENER HOLE AT FR 16 RIGHT HAND AT FORWARD GALLEY DOOR STOP # 7 INTERCOSTAL FITTING. INSTALLED MODIFIED…
- 15 Apr 2020
Fitting, cracked
AIRCRAFT IN BASE MAINTENANCE: CRACK AT LOWER INBOARD FASTENER HOLE OF L-1 DOOR STOP # 1 INTERCOSTAL FITTING AT FR16, STRINGER 11. REPLACED INTERCOSTAL FITTING…
- 15 Apr 2020
Fitting, cracked
AIRCRAFT IN BASE MAINTENANCE: CRACK ON INTERCOSTAL FITTING AT L-1 DOOR STOP # 7 AT FR 16, STR 10L. REPLACED INTERCOSTAL FITTING PER SRM 51-72-11.
- 14 Apr 2020
Floor Panel, delaminated
AIRCRAFT IN BASE MAINTENANCE: DELAMINATED FLOOR PANEL 211GF IN COCKPIT. MODIFIED FLOOR PANEL INSTALLED PER SRM 53-12-00-300-006.
- 14 Apr 2020
Floor Panel, delaminated
AIRCRAFT IN BASE MAINTENANCE: DELAMINATION ON FLOOR PANEL 211FF IN THE COCKPIT. MODIFIED FLOOR PANEL INSTALLED PER SRM 53-12-00.
- 14 Apr 2020
Floor Panel, delaminated
AIRCRAFT IN BASE MAINTENANCE: DELAMINATED AREA OF FLOOR PANEL 212GF IN COCKPIT. MODIFIED FLOOR PANEL INSTALLED PER SRM 53-12-00-300.
- 14 Apr 2020
Floor Panel, delaminated
AIRCRAFT IN BASE MAINTENANCE: DELAMINATED AREA OF FLOOR PANEL 212EF IN COCKPIT. REPLACED FLOOR PANEL PER SRM 53-12-00-300-006
- 14 Apr 2020
Floor Panel, delaminated
AIRCRAFT IN BASE MAINTENANCE: DELAMINATED AREA OF FLOOR PANEL 212HF IN COCKPIT. REPLACED FLOOR PANEL 212HF PER SRM 53-12-00.
- 14 Apr 2020
Floor Panel, delaminated
AIRCRAFT IN BASE MAINTENANCE: DELAMINATION ON FLIGHT COMPARTMENT FLOOR PANEL # 211JF AT FR 12, STR. 23R. REPLACED FLOOR PANEL PER SRM 53-12-00.
- 13 Apr 2020
Floor Panel, delaminated
AIRCRAFT IN BASE MAINTENANCE: CABIN FLOOR PANEL 232EF DELAMINATED. REPLACED FLOOR PANEL PER SRM 53-12-00-300-006.
- 13 Apr 2020
Floor Panel, delaminated
AIRCRAFT IN BASE MAINTENANCE: CABIN FLOOR PANEL 222CF DELAMINATED. REPLACED FLOOR PANEL PER SRM 53-12-00-300-006.
- 13 Apr 2020
Floor Panel, delaminated
AIRCRAFT IN BASE MAINTENANCE: CABIN FLOOR PANEL 231CF DELAMINATED. REPLACED FLOOR PANEL PER SRM 53-12-00-300-006.
- 13 Apr 2020
Floor Panel, delaminated
AIRCRAFT IN BASE MAINTENANCE: FLOOR PANEL 232FF DELAMINATED. REPLACED FLOOR PANEL PER SRM 53-12-00-300-006.
- 13 Apr 2020
Floor Panel, delaminated
AIRCRAFT IN BASE MAINTENANCE: CABIN FLOOR PANEL 251WF DELAMINATED. REPLACED FLOOR PANEL PER SRM 53-02-00-300-011.
- 13 Apr 2020
Floor Panel, delaminated
AIRCRAFT IN BASE MAINTENANCE: CABIN FLOOR PANEL 261BG DELAMINATED. REPLACED FLOOR PANEL PER SRM 53-02-00-300-011.
- 13 Apr 2020
Floor Panel, delaminated
AIRCRAFT IN BASE MAINTENANCE: FORWARD GALLEY AREA FLOOR PANEL 221PF DELAMINATED. MODIFIED FLOOR PANEL INSTALLED PER SRM 53-12-00-300-006.
- 13 Apr 2020
Floor Panel, delaminated
AIRCRAFT IN BASE MAINTENANCE: CABIN FLOOR PANEL 221DF DELAMINATED. REPLACED CABIN FLOOR PANEL PER SRM 53-12-00.
- 13 Apr 2020
Floor Panel, delaminated
AIRCRAFT IN BASE MAINTENANCE: CABIN FLOOR PANEL 261PF DELAMINATED. REPLACED FLOOR PANEL PER SRM 53-02-00.
- 13 Apr 2020
Floor Panel, delaminated
AIRCRAFT IN BASE MAINTENANCE: DELAMINATION ON CABIN FLOOR PANEL # 232DF BETWEEN FR 20 TO FR 21 AND BETWEEN -Y254 TO -Y765. REPLACED FLOOR PANEL PER SRM…
- 13 Apr 2020
Frame, cracked
AIRCRAFT IN BASE MAINTENANCE: .070 INCHES CRACK IN FASTNER HOLE OF FRAME SECTION FR 68 AT STRINGER 23 LEFT. REPAIRED FRAME SECTION FR 68 PER SRM 51-42-11,…
- 13 Apr 2020
Hinge Fitting, cracked
AIRCRAFT IN BASE MAINTENANCE: CRACK IN LEFT HAND MAIN LANDING GEAR DOOR FORWARD HINGE FITTING BETWEEN FR42 TO FR 43, STRINGER 42 LEFT. REPLACED FORWARD HINGE…
- 12 Apr 2020
Floor Panel, delaminated
AIRCRAFT IN BASE MAINTENANCE: CABIN FLOOR PANEL 241MF DELAMINATED. REPLACED FLOOR PANEL PER SRM 53-02-00-300-011.
- 12 Apr 2020
Floor Panel, delaminated
AIRCRAFT IN BASE MAINTENANCE: CABIN FLOOR PANEL 241JF DELAMINATED. REPLACED CABIN FLOOR PANEL PER SRM 53-12-00.
- 10 Apr 2020
Skin Panel, cracked
AIRCRAFT IN BASE MAINTENANCE: LOWER FUSELAGE AFT SKIN PANEL #2 FASTENER HOLE CRACKED AT FR 35 AND S30L. REPAIRED FUSELAGE SKIN PANEL PER EA 305114.
- 13 Jan 2020
Brake Sys, contaminated
AIRCRAFT WAS GROUNDED: BRAKING UNEVEN. PULLED EXCESSIVELY TO LEFT SIDE. BLEED LT #1 AND #2 BRAKES IAW 32-42-00-870-01.
- 1 Dec 2019
Battery Pack, no test
AIRCRAFT WAS NOT GROUNDED: FORWARD FLASHLIGHT NOT FLASHING. MAINTENANCE REPLACED BATTERY PACK PER AMM 25-60-00.
- 17 Sep 2019
Light, miswired
AIRCRAFT WAS GROUNDED: EXIT LIGHTS ABOVE BOTH REAR DOORS NOT ILLUMINATED. MAINTENANCE CORRECTED MISWIRING FOR DOORS L2 AND R2 (SEE AALA201909189020) PER AMM…
- 17 Sep 2019
Light, miswired
AIRCRAFT WAS GROUNDED: EXIT LIGHTS ABOVE BOTH REAR DOORS NOT ILLUMINATED. MAINTENANCE CORRECTED MISWIRING FOR DOORS L2 (SEE AALA201909189008) AND R2 PER AMM…
- 12 Sep 2019
Light, inoperative
AIRCRAFT WAS GROUNDED: EMERGENCY EXIT LIGHT INOPERATIVE ON SIDE OF SEAT 23C, AISLE LIGHT.***SUPPLEMENTAL ACTION SECTION 4 AND 5: RELAMPED SEAT 23C EMERGENCY…
- 11 Sep 2019
Battery, discharged
AIRCRAFT WAS GROUNDED: EMERG LIGHTS AT 2L AND 2R STAY ILLUMINATED. REMOVED AND REPLACED AFT CABIN EMERGENCY POWERT SUPPLY UNIT BATTERY IAW AMM 31-51-38. ALL…
- 1 Sep 2019
Cylinder, cracked
AIRCRAFT IN BASE VISIT: CRACK PASSENGER CREW DOOR 841 DAMPER AND OPERATIONAL CYLINDER ATFWD GALLEY AREA (1 EA). REPLACED DOOR DAMPER AND EMERGENCY GENERATION…
- 23 Aug 2019
Floor Panel, delaminated
AIRCRAFT IN BASE MAINTENANCE: AFT WET AREA FLOOR PANEL 262BG DELAMINATED. REPLACED FLOOR PANEL PER SRM 53-02-00-300-011.
- 23 Aug 2019
Door Sill, corroded
AIRCRAFT IN BASE MAINTENANCE: CORROSION ON RIGHT HAND AFT DOOR CUT OUT LOWER SILL BETWEEN FR 67 AND FR 68 AT S23R. REPAIRED LOWER SILL PER SRM 53-41-14-300-001.
- 23 Aug 2019
Floor Panel, delaminated
AIRCRAFT IN BASE MAINTNANCE: FORWARD WET AREA FLOOR PANEL 222EF DELAMINATED. REPLACED FLOOR PANEL PER SRM 53-02-00-300-011.
- 23 Aug 2019
Floorbeam, corroded
AIRCRAFT IN BASE MAINTENANCE: CORROSION ON FLOORBEAM AT FR 16, LBL Y1292. REPLACED FLOORBEAM PER SRM 51-72-11-911-001 DRAWING #D53110920 AND D53110984.
- 23 Aug 2019
Floor Panel, delaminated
AIRCRAFT IN BASE MAINTENANCE: DELAMINATION ON FLOOR PANEL 261AG. REPLACED FLOOR PANEL PER SRM 53-02-00-300-011 AND IRM 9701 REVISION I.
- 23 Aug 2019
Floorbeam, corroded
AIRCRAFT IN BASE MAINTENANCE: CORROSION ON FLOORBEAM AT FR 20+3, RBL -Y1292. REPLACED FLOORBEAM PER SRM 51-72-11-911-001 DRAWING #D53110984, D53112812.
- 23 Aug 2019
Floorbeam, corroded
AIRCRAFT IN BASE MAINTENANCE: CORROSION ON FLOORBEAM AT FR 66, LBL Y765. REPLACED FLOORBEAM PER SRM 51-72-11-911-001 DRAWING #D53472000 AND D53472815.
- 23 Aug 2019
Shear Plate, cracked
AIRCRAFT IN BASE MAINTENANCE: CRACKED SHEAR PLATE BETWEEN FR 69 AND FR 70 AT S23R. REPLACED SHEAR PLATE PER SRM 51-72-11.
- 22 Aug 2019
Skin, saturated
AIRCRAFT IN BASE MAINTENANCE: LEFT HAND ELEVATOR LOWER SURFACE SKIN HAS INDICATION OF TRAPPED WATER BETWEEN RIB 3 AND RIB 4 AND 5.20 INCHES FROM THE TRAILING…
- 21 Aug 2019
Skin, saturated
AIRCRAFT IN BASE MAINTENANCE: LEFT HAND ELEVATOR UPPER SURFACE SKIN HAS INDICATION OF TRAPPED WATER 12.8 INCHES OUTBOARD OF RIB 1 AND 25.5 INCHES FROM THE…
- 21 Aug 2019
Skin, saturated
AIRCRAFT IN BASE MAINTENANCE: LEFT HAND ELEVATOR UPPER SURFACE SKIN HAS INDICATION OF TRAPPED WATER 46.5 INCHES OUTBOARD OF RIB 5 AND 10.5 INCHES FROM THE…
- 21 Aug 2019
Skin, saturated
AIRCRAFT IN BASE MAINTENANCE: LEFT HAND ELEVATOR UPPER SURFACE SKIN HAS INDICATION OF TRAPPED WATER 56.3 INCHES OUTBOARD OF RIB 5 AND 5.4 INCHES FROM THE…
- 21 Aug 2019
Skin, saturated
AIRCRAFT IN BASE MAINTENANCE: LEFT HAND ELEVATOR LOWER SURFACE SKIN HAS INDICATION OF TRAPPED WATER BETWEEN RIB 7 AND RIB 8 AND 2.53 INCHES FROM THE TRAILING…
- 21 Aug 2019
Skin, saturated
AIRCRAFT IN BASE MAINTENANCE: LEFT HAND ELEVATOR UPPER SURFACE SKIN HAS INDICATION OF TRAPPED WATER 15.6 INCHES OUTBOARD OF RIB 1 AND 22 INCHES FROM THE…
- 4 Aug 2019
Light, dim
AIRCRAFT WAS NOT GROUNDED: EMERGENCY EXIT SIGN OVER R1 DOOR DIM. MAINTENANCE REPLACED LIGHT PER AMM 33-51-11.
- 14 May 2019
Compressor Blade, damaged
AIRCRAFT WAS GROUNDED: PILOT REJECTED TAKEOFF AT 40-60 KNOTS DUE TO ENGINE ONE COMPRESSOR STALL. NO INJURIES REPORTED. FLIGHT RETURNED TO GATE FOR MAINTENANCE…
- 1 Apr 2019
Door, out of adjust
AIRCRAFT NOT GROUNDED: PILOT REPORTS IN CRUISE TRIED TO OPEN COCKPIT DOOR. COULD NOT OPEN DOOR FROM INSIDE. COULD NOT ROATATE HANDLE FROM INSIDE COCKPIT. F/A…
- 17 Mar 2019
Floor Panel, damaged
THE AFT CARGO BAY FLOOR PANEL 151VG WAS SPONGY. REPLACED THE FLOOR PANEL IAW AMM 53-42-14.
- 20 Apr 2018
Cover, broken
BROKEN EMERGENCY LIGHT COVER AT SEAT 15, 16, 17 AND, 19 LEFT. MAINTENANCE REPLACED THE LIGHT COVER AND PERFORMED A SATISFACTORY OPERATIONAL CHECK.
- 20 Apr 2018
Cover, broken
BROKEN EMERGENCY LIGHT COVER AT SEATS 15, 16, 17, AND 19 LEFT. MAINTENANCE REPLACED THE LIGHT COVER AND PERFORMED A SATISFACTORY OPERATIONAL CHECK.
- 20 Apr 2018
Cover, broken
BROKEN EMERGENCY LIGHT COVER AT SEATS 15, 16, 17, AND 19 LEFT. MAINTENANCE REPLACED THE LIGHT COVERS AND PERFORMED SATISFACTORY OPERATIONAL CHECK.
- 20 Apr 2018
Cover, broken
BROKEN EMERGENCY LIGHT COVER AT SEATS 15, 16, 17, AND 19 LEFT. MAINTENANCE REPLACED THE LIGHT COVER AND PERFORMED A SATISFACTORY OPERATIONAL CHECK.
- 8 Nov 2017
Lens, damaged
SEATS 9C, EMERGENCY LIGHT LENS DAMAGED. REPLACED THE LENS.
- 23 Aug 2017
Accumulator, malfunctioned
DURING THE ALTERNATE BRAKE CHECK, THE ACCUMULATOR PRESSURE WENT DOWN ABOUT 1,000 WITH 1 APPLICATION OF THE LEFT AND RIGHT BRAKE PEDALS. ACCUMULATOR BLEED DOWN…
- 13 Aug 2017
Lens, broken
EMRERGENCY EXIT SIGN LENS BROKEN AT ROW 9C. REPLACED THE LENS IAW AMM.
- 3 Aug 2017
Smoke Detector, false activation
AFT LAVATORY SMOKE DETECTOR ALARMED TWICE IN FLIGHT, FALSE ALARMS. ACCOMPLISHED OPERATIONAL TEST OF THE LAVATORY SMOKE DETECTION SYSTEM IAW AMM…
- 4 Jun 2017
Coffeemaker, odor
AFT CABIN ODOR. VERIFIED AFT GALLEY NR 2 COFFEEMAKER CAUSING ODOR. REMOVED AND REPLACED THE COFFEEMAKER.
- 10 Mar 2017
Apu, odor
AIRCRAFT WAS GROUNDED. ODOR REPORTED ON APPROACH BY FLIGHT ATTENDANT AT APPROX. 3000' AGL. NOTICED A MUSTY DIRTY SOCKS ODOR IN THE COCKPIT AT THE SAME TIME…
- 22 Dec 2016
Control Unit, faulted
AT 70 KTS ECAM MESSAGE INDICATED ENGINE THRUST LEVERS NOT SET. REJECTED TAKE OFF. ACCOMPLISHED OPERATIONS TEST OF THROTTLE CONTROL UNIT IAW AMM 76-11-00 AND…
- 26 Oct 2016
Oven, odor
FORWARD GALLEY OVEN 1 HAS ELECTRICAL ODOR WHEN TURNED ON PREVIOUS LEG. OVEN NOT USED LAST LEG. MAINTENANCE REPLACED THE OVEN AND ACCOMPLISHED A SATISFACTORY…
- 22 Aug 2016
Windshield, cracked
AIRCRAFT WAS GROUNDED, OBSERVED CAPTAIN`S WINDOW ARCING LOWER RT, FOLLOWED BY OUTER PANE CRACK. TRIED TO ACCOMPLISH CB PULL BUT WINDOW CRACKED QUICKLY.…
- 22 Aug 2016
Computer, defective
AIRCRAFT WAS GROUNDED, OBSERVED CAPTAIN`S WINDOW ARCING LOWER RT, FOLLOWED BY OUTER PANE CRACK. TRIED TO ACCOMPLISH CB PULL BUT WINDOW CRACKED QUICKLY.…
- 14 Aug 2016
O-Ring, leaking
FLIGHT CREW REPORTED A DIRTY SOCK ODOR IN THE COCKPIT, FIRST CLASS & OVERWING AREAS OF THE AIRCRAFT WHILE WAITING FOR DEPARTURE AT THE GATE. MAINTENANCE FOUND…
- 4 Jul 2016
Shear Plate, cracked
AIRCRAFT IN BASE MAINTENANCE: LEFT SHEAR PLATE CRACKED AT FRAME 68 + 6" AND +Y1292. REPLACED SHEAR PLATE IAW SRM 53-41-14, 51-42-11 AND DWG D53480019007.
- 23 May 2016
Box Beam, cracked
AIRCRAFT WAS IN BASE MX. LT SIDE BOX BEAM UPPER FLANGE AFT FASTENER HOLE HAS CRACK INDICATION AT FRAME 43 & +Y1622. REPAIRED BOX BEAM IAW EO 5315Y066.
- 23 May 2016
Box Beam, cracked
AIRCRAFT WAS IN BASE MX. RT SIDE BOX BEAM UPPER FLANGE AFT FASTENER HOLE HAS CRACK INDICATION AT FRAME 43 & -Y162. REPAIRED BOX BEAM IAW EO 5315Y066.
- 27 Mar 2016
Battery, discharged
AIRCRAFT WAS NOT GNDED. AFT GALLEY FLASHLIGHT NOT CHARGING. REPLACED BATTERY & ACCOMPLISHED A SATISFACTORY OPERATIONAL CHECK.
- 23 Dec 2015
Unknown, odor
AIRCRAFT WAS NOT GNDED. SHORTLY AFTER TAKEOFF, CHEMICAL OR ELEC SMELL NOTED. STRONG IN AFT CABIN. DISSIPATED AFTER 10 MINS. ACCOMPLISHED JC 26L00021001.…
- 7 Oct 2015
Pump, defective
L TANK PUMP 2, ECAM CAUTION LIGHT ON DURING TAXI OUT. REPLACED LT WING NR 2 FUEL PUMP. ACCOMPLISHED A SATISFACTORY OPERATIONAL & LEAK CHECK IAW AMM 28-21-51.
- 6 Sep 2015
Sign, dim
EXIT SIGN NEAR RT OVERWING EXIT DIM. REPLACED EXIT SIGN & ACCOMPLISHED A SATISFACTORY OPERATIONAL CHECK IAW AMM 33-51-02.
- 23 Jul 2015
Lens, unsecure
EMERGENCY EXIT COVER OFF DOOR 2R. REPLACED 2R EMER EXIT LENS COVER.
- 12 May 2015
Slide, defective
WHILE ACCOMPLISHING A SCHEDULED TIME CHANGE OF THE R2 ESCAPE SLIDE, THE REPLACEMENT SLIDE COULD NOT BE INSTALLED ON THE ACFT DUE TO A BROKEN SAFETY WIRE ON…
- 29 Oct 2014
Power Supply, inoperative
RON EMER LIGHTS FAILED STEP 13 ON JOB CARD 26L00005005 WEEKLY CHECK. EMER LIGHT CHECK INT FAULT LT. REPLACED EPSU 10WL & BATTERY AMM 33-51-38-400-002-A 001-A.…
- 29 Oct 2014
Power Supply, inoperative
RON EMER LIGHTS FAILED STEP 13 ON JOB CARD 26L00005005 WEEKLY CHECK. EMER LIGHT CHECK INT FAULT LT. REPLACED EPSU 11WL & BATTERY AMM 33-51-38-400-002-A 001A.…
- 3 Sep 2014
Cylinder, unserviceable
WHILE ACCOMPLISHED L1 SLIDE REPLACEMENT, FOUND DOOR DAMPER SHEAR WIRE BROKEN. R & R L1 DOOR DAMPER EMER OPERATIONS CYLINDER IAW AMM 52-11-14.
- 14 Feb 2014
Lens, missing
THE EMERGENCY LIGHT LENS MISSING AT SEAT 3C. REPLACED MISSING LENS AS REQUIRED.
- 31 Dec 2013
Battery, discharged
CREW REPORTED THE EMERGENCY FLASHLIGHT AT AFT LT CABIN JUMP SEAT DOES NOT FLASH. REPLACED BATTERY ON AFT LT EMERGENCY FLASHLIGHT, OK FOR SERVICE.
- 25 Dec 2013
Oven, odor
BURNT ELEC WIRE SMELL COMING FROM OVEN NR 1 IN FWD GALLEY. REMOVED NR 1 OVEN IN FWD GALLEY INSERT. OPERATIONS NORMAL IAW A319 AMM CHAPTER 20.
- 4 Sep 2013
Power Supply, inoperative
EMERGENCY LIGHT POWER SUPPLY DOES NOT HAVE 115 VAC OUTPUT. R & R POWER SUPPLY IAW AMM 33-51-38-00-001-A.
- 4 Sep 2013
Power Supply, inoperative
EMERGENCY LIGHT FWD LT POWER SUPPLY FAULTED. REPLACED POWER SUPPLY UNIT AND BATTERY IAW AMM 33-51-38-400.
- 28 Aug 2013
Skin, contaminated
2S CHECK - WATER INGRESS INDICATION ON RT ELEVATOR UPPER SKIN SURFACE APPROX 110 INCHES FROM INBD END & 11 INHCES FROM T/E. REPAIRED RT ELEVATOR UPPER SKIN…
- 28 Aug 2013
Skin, contaminated
2S CHECK - WATER INGRESS INDICATION ON RT ELEVATOR UPPER SKIN SURFACE APPROX 58 INCHES FROM INBD END & 10 INCHES FROM T/E. REPAIRED RT ELEVATOR UPPER SKIN…
- 28 Aug 2013
Skin, saturated
2S CHECK - WATER INGRESS INDICATION ON RT ELEVATOR UPPER SKIN SURFACE APPROX 96 INCHES FROM INBD END & 22.5 INCHES FROM T/E. REPAIRED RT ELEVATOR UPPER SKIN…
- 28 Aug 2013
Skin, contaminated
2S CHECK - WATER INGRESS INDICATION ON RT ELEVATOR UPPER SKIN SURFACE APPROX 44 INCHES FROM INBD END & 22 INCHES FROM T/E. REPAIRED ELEVATOR SKIN IAW SRM…
- 28 Aug 2013
Skin, contaminated
2S CHECK - WATER INGRESS INDICATION ON RT ELEVATOR UPPER SKIN SURFACE APPROXIMATELY 118 INCHES FROM INBD END & 11 INCHES FROM T/E. REPAIRED ELEVATOR SKIN…
- 28 Aug 2013
Skin, contaminated
2S CHECK - WATER INGRESS INDICATION ON RT ELEVATOR UPPER SKIN SURFACE APPROXIMATELY 102 INCHES FROM INBD END & 20.5 INCHES FROM T/E. REPAIRED ELEVATOR SKIN…
- 26 Aug 2013
Skin, saturated
2S CHECK - PREVIOUS REPAIR SHOWS SIGNS OF WATER ENGRESS ON LT ELEVATOR UPPER SURFACE APPROX 38.5" FROM INBD END & 5.5" FROM T/E. REPAIRED LT ELEVATOR UPPER…
- 26 Aug 2013
Skin, saturated
2S CHECK, INDICATION OF WATER ENGRESS ON LT ELEVATOR UPPER SURFACE APPROX 90" FROM OTBD END & 9.5" FROM T/E. REPAIRED LT ELEVATOR UPPER SURFACE IAW EA 205493.
- 26 Aug 2013
Skin, saturated
2S CHECK, INDICATION OF WATER ENGRESS ON LT ELEVATOR UPPER SURFACE APPROX 103" FROM OTBD END & 6" FROM T/E. REPAIRED LT ELEVATOR UPPER SURFACE IAW EA 205493.
- 22 Aug 2013
Floor Panel, delaminated
DURING 2S CHECK, FOUND DELAMINATION ON FLOOR PANEL 222CF BETWEEN FRAMES 12 TO 16, Z-500 & -Y1379.5 TO -Y81. REPLACED FLOOR PANEL IAW IRM 9701, REV G.
- 22 Aug 2013
Floor Panel, delaminated
DURING 2S CHECK, FOUND DELAMINATION ON FLOOR PANEL 222DF BETWEEN FRAMES 16 TO 20, Z-500 & -Y81 TO -Y503.2. REPLACED FLOOR PANEL IAW IRM 9701, REV. G.
- 22 Aug 2013
Floor Panel, delaminated
DURING 2S CHECK, FOUND DELAMINATION ON FLOOR PANEL 241CF BETWEEN FRAMES 35.8 TO 36, Z-500 & -Y765 TO -Y1037. REPLACED FLOOR PANEL IAW IRM 9701, REV G.
- 22 Aug 2013
Floor Panel, delaminated
DURING 2S CHECK, FOUND DELAMINATION ON FLOOR PANEL 262HG BETWEEN FRAMES 64 TO 66, Z-500 & -Y765 TO -Y1589. REPLACED FLOOR PANEL IAW IRM 9701, REV G.
- 22 Aug 2013
Floor Panel, delaminated
2S CHECK - AREA OF DELAMINATION ON FLOOR PANEL 231CF BETWEEN FRAMES 20 TO 24, Z-500 & BETWEEN Y765 TO Y254. REPLACED FLOOR PANEL IAW IRM 9701, REV G.
- 17 Aug 2013
Floor Panel, damaged
DURING 2S CHECK, UPPER SURFACE OF FLOOR PANEL 221EF PEELING BETWEEN FR 16 TO 20, Z-500 & Y765 TO Y1265. REPLACED FLOOR PANEL IAW IRM 9701, REV G.
- 7 Aug 2013
Sill, corroded
DURING 2S CHECK, FOUND CORROSION ON RT AFT ENTRYWAY AFT SHAPE SILL AT FR67, -Y1292. REPLACED SILL IAW SRM 53-41-69.
- 12 Jun 2013
Proximity Sensor, faulty
AFTER LANDING AT FLAP RETRACTION, CREW RECIEVED ECAM MESSAGE F/CTL FLAPS LOCKED - ALIGNMENT FAULT. MX FOUND FIN 38CV FAULT. R & R FIN 38CV IAW AMM 27-51-44.…
- 17 Apr 2013
Power Supply, failed
MAINTENANCE REPORTED THE FORWARD CABIN EMERGENCY LIGHT POWER SUPPLY UNIT FAILED INTERNAL & EXTERNAL LOAD TESTS. MAINTENANCE REPLACED FORWARD CABIN EMERGENCY…
- 17 Feb 2013
Girt Bar, dirty
DOOR 2R ARMING HANDLE REPORTED BY CREW AS SPONGY AND DISARMS INTERMITTENTLY DURING FLIGHT. MAINTENANCE CLEANED AND INSPECTED R2 DOOR ARMED HANDLE AND GIRT…
- 8 Feb 2013
Unknown, smoke
AFTER LANDING, THE NR 1 FLIGHT ATTENDANT SMELLED AND SAW A THIN LAYER OF SMOKE NEAR ROW 1 (ELECTRICAL SMELL). MAINTENANCE COMPLIED WITH J/C 26L00021001 AND…
- 13 Jan 2013
Proximity Switch, out of adjust
CREW REPORTED DOOR 2R NOT SHOWING ARMED ON ECAM UNLESS PRESSURE IS PUT ON ARMING HANDLE (DOOR SHOWED ARMED AT PUSH BACK). MAINTENANCE TROUBLESHOT 2R DOOR PER…
- 12 Jan 2013
Girt Bar, obstructed
CREW REPORTED DOOR 2R NOT SHOWING ARMED ON ECAM UNLESS PRESSURE IS PUT ON HANDLE. CLEARED DEBRIS (BOTTLE CAP) FROM GIRT BAR AREA. ARMED AND DISARMED DOOR 2R.…
- 10 Jan 2013
Lens, wrong part
CREW REPORTS LAV D EMERGENCY LIGHT IS THE WRONG COLOR. MAINTENANCE INSTALLED CORRECT LENS.
- 4 Jan 2013
Floorbeam, corroded
SY6 CHECK - LEVEL 2 GALVANIC CORROSION ON FLOORBEAM BETWEEN FR64 TO FR67, Y1292. REPLACED FLOORBEAM BETWEEN FR64 TO FR67, Y1292 IAW A319 SRM 53-00-14, FIG 102…
- 3 Jan 2013
Floor Panel, corroded
SY6 CHECK - CORROSION & DISBONDING ON FLOOR PANEL 222FF BETWEEN FR16 TO FR20 & -Y1732 TO -Y1292. REPLACED FLOOR PANEL 222FF IAW A319 AMM 53-12-12 & SRM…
- 3 Jan 2013
Sill, corroded
SY6 CHECK - LEVEL 2 GALVANIC CORROSION ON DOOR SILL AT FR66, Y1732. REPLACED DOOR SILL AT FR66, Y1732 IAW A319 SRM 53-41-14 FIG 101 & 53-41-14 FIG 201.
- 2 Jan 2013
Plate, cracked
SY6 CHECK - CRACK ON WEB PLATE BETWEEN FR68 TO FR69, S23R. REPLACED WEB PLATE BETWEEN FR68 TO FR69, S23R IAW A319 SRM 51-42-11.
- 2 Jan 2013
Shear Plate, corroded
SY6 CHECK - LEVEL 2 GALVANIC CORROSION ON SHEAR PLATE BETWEEN FR69 TO FR70, S23L. REPLACED SHEAR PLATE BETWEEN FR69 TO FR70, S23L IAW A319 SRM 51-72-11.
- 2 Jan 2013
Shear Plate, corroded
SY6 CHECK - LEVEL 2 GALVANIC CORROSION ON SHEAR PLATE BETWEEN FR69 TO FR70, S23R. REPLACED SHEAR PLATE BETWEEN FR69 TO FR70, S23R IAW A319 SRM 51-42-11 &…
- 2 Jan 2013
Floorbeam, corroded
SY6 CHECK - LEVEL 2 GALVANIC CORROSION ON FLOORBEAM BETWEEN FR67 TO FR68, Y1292. REPLACED FLOORBEAM BETWEEN FR67 TO FR68, Y1292 IAW A319 SRM 51-42-11.
- 2 Jan 2013
Floorbeam, corroded
SY6 CHECK - LEVEL 2 GALVANIC CORROSION ON FLOORBEAM BETWEEN FR66 TO FR68, -Y1292. REPLACED FLOORBEAM BETWEEN FR66 TO FR68, -Y1292 IAW A319 SRM 51-72-11,…
- 2 Jan 2013
Floorbeam, corroded
SY6 CHECK - LEVEL 2 GALVANIC CORROSION ON FLOORBEAM BETWEEN FR68 TO FR69, Y1292. REPLACED FLOORBEAM BETWEEN FR68 TO FR69, Y1292 IAW A319 SRM 51-42-11 &…
- 31 Dec 2012
Dummy Rail, corroded
SY6 CHECK - LEVEL 2 GALVANIC CORROSION ON DUMMY RAIL AT FR16-2 INCHES, Y503.2. REPLACED DUMMY RAIL AT FR16-2 INCHES, Y503.2 IAW A319 SRM 53-11-14 FIG 103 &…
- 16 Nov 2012
Battery Pack, discharged
FORWARD LEFT FLASHLIGHT INOPERATIVE. REMOVED AND REPLACED BATTERY PACK LEFT FORWARD FLASHLIGHT. OPS CHECKED GOOD.
- 25 Oct 2012
Power Supply, inoperative
EMERGENCY LIGHTS FAIL TEST "EPSU INT LOAD AFT L". REMOVED AND REPLACED AFT LEFT (EPSU) EMERGENCY POWER SUPPLY UNIT PER AMM 33-58-30-401.
- 24 Jul 2012
Battery, discharged
FORWARD MEGAPHONE INOPERATIVE. REPLACED FORWARD MEGAPHONE BATTERIES.
- 2 Mar 2012
Cable, defective
SEAT ROW 22ABC EMERGENCY SEAT MOUNTED LIGHT INOPERATIVE. REMOVED AND REPLACED SEAT CABLE 5409VB IAW TR320-3350-11-0541. OPS CHECKED GOOD PER AMM 33-51-00-501.
- 18 Aug 2011
Unknown, malfunctioned
R1 DOOR DOES NOT SHOW SLIDE ARMED INDICATION ON ECAM WITH DOOR CLOSED & ARMED. PERFORMED OPS CHECK OF SLIDE INDICATION OF R1 DOOR. AIRBUS MAINTENANCE MANUAL…
- 15 Nov 2010
Battery, discharged
FLT 634 - PHX-PIT - EEL - EMERGENCY EXIT LIGHTS 1L & 1R ARE NOT ILLUMINATING. MAINTENANCE REMOVED AND REPLACED FORWARD EMERGENCY LIGHT BATTERY IAW AIRBUS…
- 9 Feb 2010
Skin, contaminated
SAL - MAJOR REPAIR - C6 CHECK - RT ELEVATOR UPPER SKIN. TRAPPED WATER WAS FOUND IN HONEY COMB CORE STRUCTURE BETWEEN RIB 1 AND 4, STAB STA 181- STAB STA 227.…
- 9 Feb 2010
Skin, contaminated
SAL - MAJOR REPAIR - C6 CHECK - RT ELEVATOR UPPER SKIN. TRAPPED WATER WAS FOUND IN HONEY COMB CORE STRUCTURE BETWEEN RIB 1 AND 4, STAB STA 227- STAB STA 271.…
- 4 Feb 2010
Damper, low pressure
SAL - EES - C6 CHECK - L1 DOOR EMERGENCY CYLINDER DOOR DAMPER PRESSURE LOW. SERVICED THE L1 DOOR EMERGENCY CYLINDER DOOR DAMPER IAW A319 AMM 52-10-00.
- 4 Feb 2010
Damper, low pressure
SAL - EES - C6 CHECK - R1 DOOR CYLINDER DOOR DAMPER PRESSURE LOW. SERVICED R1 DOOR CYLINDER DOOR DAMPER IAW A319 AMM 52-10-00-614-050.
- 31 Jan 2010
Striker, out of adjust
SAL - EES - C6 CHECK - PASSENGER / CREW DOOR 842, DOOR DAMPER AND EMERGENCY OPERATION STRIKER FOUND TO BE OUT OF ADJUSTMENT. ADJUSTED THE PASSENGER / CREW…
- 30 Jan 2010
Striker, out of adjust
SAL - C6 - EES - OUT OF ADJUSTMENT DIMENSION B BETWEEN FINGER & STRIKER AT FORWARD ENTRANCE DOOR DAMPER PERCUSSION BELL CRANK FINGER. PERFORMED ADJUSTMENT OF…
- 30 Jan 2010
Striker, out of adjust
SAL - C6 - EES - OUT OF ADJUSTMENT DIMENSION B BETWEEN FINGER & STRIKER AT AFT ENTRANCE DOOR DAMPER PERCUSSION BELL CRANK FINGER. PERFORMED ADJUSTMENT OF…
- 28 Jan 2010
Damper, low pressure
SAL - C6 - EES - LOW PRESSURE AT FORWARD SERVICE DOOR EMERGENCY CYLINDER DAMPER. CHARGED THE EMERGENCY CYLINDER DAMPER AT FORWARD SERVICE DOOR IAW A319 AMM…
- 28 Jan 2010
Damper, low pressure
SAL - C6 - EES - LOW PRESSURE AT AFT ENTRY DOOR EMERGENCY CYLINDER DAMPER. CHARGED THE EMERGENCY CYLINDER DAMPER AT AFT ENTRY DOOR IAW A319 AMM 52-10-00.
- 28 Jan 2010
Hinge Fitting, excess play
SAL - C6 - MAJOR REPAIR - EXCESSIVE PLAY ON RUDDER HINGE FITTING NR 3 AT STAB STA 2279 / RIB 5. REPLACED RUDDER HINGE FITTING NR 3 AT STAB STA 2279 / RIB 5…
- 27 Jan 2010
Elevator, contaminated
SAL - C6 - MAJOR REPAIR - TRAPPED WATER FOUND IN LEFT ELEVATOR UPPER SKIN BETWEEN STAB STA 181 TO STAB STA 404 BETWEEN ELEV RIB 3 TO ELEV RIB 6. REPAIRED…
- 10 Oct 2008
Fan, failed
FLT 440 PHX-DCA BURNING ODOR. DURING CRUISE, HEARD A LOUD RUMBLING NOISE ALONG WITH ELECTRICAL ODOR. SHUT OFF BLOWER FAN TO OVERRIDE. NOISE AND ODOR STOPPED.…
- 12 Oct 2007
Battery, discharged
PHX - EEL - FLT 210. MX REPORTED LT EPSU AT OVERWING HAS DEAD BATTERY. MX REPLACED THE LT EPSU BATTERY. OPERATIONAL CHECK WAS GOOD.
- 2 Nov 2006
Ballast, odor
LAS - SMOKE - VERY STRONG SMELL OF ELECTRICAL BURNING WIRE SMELL NEAR AFT LAVATORY, NO SMOKE NOTED. MAINTENANCE REPLACED BALLAST ON ROWS 18-22R AND WINDOW…
- 31 Oct 2006
Sill, corroded
SAL - MAJOR REPAIR - BC-4 CHECK - CORROSION ON R2 DOOR CUT OUT LOWER SILL , FS 66, -Y1472. REPAIRED R2 DOOR CUT OUT LOWER SILL , FS 66, -Y1472 IAW AWA ER…
- 24 Oct 2006
Fitting, corroded
SAL - MAJOR REPAIR - BC-4 CHECK - CORROSION ON R1 DOOR CUT OUT LOWER THRESHOLD LOWER FITTING, FS 16+9" - FS 19, S23R. REPLACED R1 DOOR CUT OUT LOWER THRESHOLD…
- 20 Oct 2006
Floor Support, corroded
BC-4 CHECK - NR 5949844, CORROSION ON MAIN CABIN LONGITUDINAL BEAM, FR 68, -Y1292. REPLACED MAIN CABIN LONGITUDINAL BEAM, FR 68, -Y1292 IAW A319 SRM 51-72-11.
- 20 Oct 2006
Floor Support, corroded
BC-4 CHECK - NR 5949853, CORROSION ON MAIN CABIN LONGITUDINAL BEAM, FR 67 - 1 INCH, +Y1292. REPLACED MAIN CABIN LONGITUDINAL BEAM, FR 67 - 1 INCH, +Y1292 IAW…
- 20 Oct 2006
Seat Track, corroded
BC-4 CHECK - NR 5949426, CORROSION ON MAIN CABIN SEAT TRACK, FR 36 + 3 INCHES TO FR 41, -Y1292. REPLACED MAIN CABIN SEAT TRACK, FR 36 + 3 INCHES TO FR 41,…
- 18 Oct 2006
Skin, delaminated
MAJOR REPAIR - BC-4 CHECK -NR 5950024, DELAMINATION FOUND ON RUDDER RT SIDE PANEL, ABOVE BR 7 NEXT TO FASTENER ROW (FASTENER NR 31), DELAMINATED AREA APROX…
- 17 Oct 2006
Floor Support, corroded
MAJOR REPAIR - BC-4 CHECK - NR 5949835, CORROSION ON MAIN CABIN DUMMY RAIL (FLOOR SUPPORT), FR20, -Y254. REPAIRED MAIN CABIN DUMMY RAIL (FLOOR SUPPORT), FR20,…
- 17 Oct 2006
Floor Support, corroded
BC-4 CHECK - NR 5949839, CORROSION ON MAIN CABIN DUMMY RAIL (FLOOR SUPPORT), FR14+7 INCHES - FR16, +Y503.2. REPLACED MAIN CABIN DUMMY RAIL (FLOOR SUPPORT),…
- 17 Oct 2006
Floor Support, corroded
BC-4 CHECK - NR 5949841, CORROSION ON MAIN CABIN DUMMY RAIL (FLOOR SUPPORT), FR21, -Y189. REPLACED MAIN CABIN DUMMY RAIL (FLOOR SUPPORT), FR21, -Y189 IAW A319…
- 17 Oct 2006
Floor Support, corroded
BC-4 CHECK - NR 5949846, CORROSION ON MAIN CABIN LONGITUDINAL BEAM, FR 68, -Y765. REPLACED MAIN CABIN LONGITUDINAL BEAM, FR 68, -Y765 IAW A319 SRM 51-42-11…
- 17 Oct 2006
Floor Support, corroded
BC-4 CHECK - NR 5949838, CORROSION ON MAIN CABIN DUMMY RAIL (FLOOR SUPPORT), FR16, +Y254. REPAIRED MAIN CABIN DUMMY RAIL (FLOOR SUPPORT), FR16, +Y254 IAW A319…
- 17 Oct 2006
Seat Track, corroded
BC-4 CHECK - NR 5949834, CORROSION ON MAIN CABIN DUMMY RAIL/SEAT TRACK, FR16, -Y765. REPAIRED MAIN CABIN DUMMY RAIL/SEAT TRACK, FR16, -Y765 IAW A319 SRM…
- 17 Oct 2006
Floorbeam, corroded
SAL - MAJOR REPAIR - CORROSION ON MAIN CABIN LONGITUDINAL FLOORBEAM, FS 66, -Y1292. REPLACED MAIN CABIN LONGITUDINAL FLOORBEAM, FS 66, -Y1292 IAW A319 SRM…
- 17 Oct 2006
Floor Support, corroded
SAL - MAJOR REPAIR - BC-4 CHECK - CORROSION ON MAIN CABIN LONGITUDINAL BEAM, FS 66 + 5" - FS 68 -5", -Y1292. REPLACED MAIN CABIN LONGITUDINAL BEAM, FS 66 + 5"…
- 17 Oct 2006
Floor Panel, corroded
MAJOR REPAIR - BC-4 CHECK - NR 5949849, CORROSION ON L2 DOOR WAY THRESHOLD FLOOR PANEL 261FF, FR66 TO FR68. REPLACED L2 DOOR WAY THRESHOLD FLOOR PANEL 261FF,…
- 16 Oct 2006
Wire, damaged
SAL - EEL - BC-4 CHECK - NR 5949617, DAMAGED EMERGENCY LIGHT PATH CABLE, SEAT ROW 6 LT. REPLACED EMERGENCY LIGHT PATH CABLE, SEAT ROW 6 LT IAW A319 AMM…
- 10 May 2006
Bypass Valve, malfunctioned
LAS - AIR TURN BACK - FLT 837 - DURING CLIMB-OUT CREW RECEIVED NR 1 PACK FAULT WITH THE NR 2 PACK BEING DEFERRED. CREW CYCLED THE NR 1 PACK SWITCH TWICE WITH…
- 10 Mar 2005
Battery, discharged
DEN - EEL - DURING 4-DAY CHECK OPERATIONAL TEST OF EMERGENCY LIGHT SYSTEM RECEIVED A LT OVERWING EMERGENCY POWER SUPPLY UNIT BATTERY FAULT. MAINTENANCE…
- 2 Apr 2004
Slide, leaking
R-2 DOOR EMERGENCY ESCAPE SLIDE RESERVOIR PRESSURE WAS BELOW SERVICEABLE LIMITS. MAINTENANCE REMOVED AND REPLACED R-2 DOOR EMERGENCY ESCAPE SLIDE ASSEMBLY IAW…
- 13 Mar 2004
Adc, faulty
JFK - ABORTED TAKEOFF - FLT 0411 - ON TAKEOFF AT JFK EN ROUTE TO SFO RECEIVED NR 1 IR FAULT, REJECTED TAKEOFF AT 90 KTS. MAINTENANCE ISSUED MEL 34-10-01, COND…
- 17 Dec 2003
Wire, chafed
JFK - EEL - DURING INSPECTION EMERGENCY ESCAPE PATH LIGHTS WERE INOPERATIVE AT FORWARD & OVERWING AREA. MAINTENANCE REMOVED AND REPLACED LT & RT OVERWING…
- 2 Nov 2003
Cable, broken
PHX - EES - DURING P-09 CHECK THE CABLE END WAS FOUND BROKEN ON THE LT OVER WING SLIDE BOTTLE. MAINTENANCE REMOVED AND REPLACED LT OVERWING SLIDE RESERVOIR…
- 2 Nov 2003
Cable, broken
PHX - EES - DURING P-09 CHECK THE CABLE END WAS FOUND BROKEN ON THE RT OVERWING SLIDE BOTTLE. MAINTENANCE REMOVED AND REPLACED RT OVERWING SLIDE RESERVOIR…
- 1 Oct 2003
Pump, leaking
EN ROUTE FROM IAD TO PHX FLIGHT CREW OBSERVED A LOSS OF THE GREEN SYSTEM HYDRAULICS, DECLARED EMERGENCY AND LANDED WITHOUT FURTHER EVENT. MAINTENANCE FOUND…