N820EX
Dehavilland DHC-8-102 FAA →
reservations
earlier registrations
1 past record
service difficulty reports
70 reports
- 15 Jun 2006
Hydraulic System, leaking
NR 2 HYDRAULIC SYSTEM DROPPED TO .5 QUARTS. RUNNER ISO CAUTION LIGHT ILLUMINATED PRESSURE REMAINED AT 3000 PSI. AN EMERGENCY WAS DECLARED. INSPECTED AND FOUND…
- 28 Sep 2002
Wire, broken
ABE-FLIGHT 3515, CREW REPORTED EMERGENCY LIGHTS INOPERATIVE FROM ROW 3 THROUGH 7 ON NR 1 SIDE. MAINTENANCE REPAIRED BROKEN WIRE IN FLOOR EMERGENCY LIGHT…
- 25 Sep 2002
Light, inoperative
DURING ROUTINE MAINTENANCE VISIT RIGHT FUSELAGE EMERGENCY EXIT LIGHTS FOUND INOPERATIVE. LIGHTS WERE RELAMPED AND FUSES REPLACED IN BATTERY PACK. OPERATIONAL…
- 16 Sep 2002
Fuse, blown
DURING ROUTINE MAINTENANCE VISIT RIGHT AFT EXTERIOR EMERGENCY LIGHT FOUND INOPERATIVE. FUSES REPLACED IN AFT EMERGENCY LIGHT POWER SUPPLY. OPERATIONAL CHECK…
- 11 Sep 2002
Connector, loose
DURING ROUTINE MAINTENANCE VISIT EMERGENCY AISLE LIGHTS FOUND INOPERATIVE AT AFT LEFT SIDE OF AIRCRAFT. THREE CONNECTORS WERE FOUND TO BE LOOSE. CONNECTORS…
- 25 Aug 2002
Connector, disconnected
DURING ROUTINE MAINTENANCE VISIT AFT HALF OF LEFT EMERGENCY FLOOR PATH LIGHTING FOUND INOPERATIVE. CIRCUIT FOUND DISCONNECTED AT AFT PLUG. THE CONNECTION WAS…
- 24 Aug 2002
Connector, loose
MHT- FLIGHT 3758. CREW REPORTED FLOOR LEVEL EMERGENCY LIGHTS INOPERATIVE FROM 4A TO 9A LEFT SIDE. MAINTENANCE RESECURED CONNECTIONS NEAR ROW 4 AND ROW 9.…
- 21 Aug 2002
Fuse, blown
DURING ROUTINE MAINTENANCE VISIT RIGHT AFT EMERGENCY LIGHT ON FUSELAGE AND EMERGENCY LIGHT IN CENTER CABIN CEILING FOUND INOPERATIVE. FUSE REPLACED IN AFT…
- 14 Aug 2002
Fuse, blown
DURING ROUTINE MAINTENANCE VISIT RIGHT AFT EMERGENCY LIGHT FOUND INOPERATIVE. BULB WAS REPLACED WITH NO FIX. AFTER TROUBLESHOOTING IT WAS DISCOVERED THAT BOTH…
- 20 Jul 2002
Light, loose
LGA-FLIGHT 3971. CREW REPORTED ALL FLOOR LEVEL EMERGENCY LIGHTS BEYOND ROW 3 ARE INOPERATIVE. MAINTENANCE RESECURED FLOOR EMERGENCY LIGHT STRIPS. OPERATIONAL…
- 6 Jul 2002
Battery Pack, inoperative
PHL- FLIGHT#126. CREW REPORTED EMERGENCY EXIT SIGN AT ROW 4 NOT ILLUMINATED. MAINTENANCE REPLACED REAR EMERGENCY LIGHT BATTERY PACK. OPERATIONAL CHECK GOOD.…
- 15 Jun 2002
Seal, leaking
PHL-SYR FLIGHT 3814. WHILE IN CRUISE FLIGHT CREW REPORTED REAR BAY OVERHEAT CAUTION LIGHT FOR APU ILLUMINATED. CREW DECLARED AN EMERGENCY AND DIVERTED TO MDT.…
- 13 Jun 2002
Light, inoperative
MAINTENANCE DISCOVERED RIGHT FLOOR STRIP (EMERGENCY) LIGHTS FROM MID EXIT TO FORWARD EXIT INOPERATIVE. WIRING CONNECTORS WERE REINSTALLED. OPERATIONAL CHECK…
- 12 May 2002
Circuit Card, burned
FLIGHT# 3581 BUF-BDL. CREW REPORTED FIRE AND SMOKE FROM FLIGHT TAXI SWITCH. MAINTENANCE FOUND AUTOPILOT DISENGAGE CIRCUIT CARD BURNT DUE TO FAULTY RESISTOR.…
- 1 May 2002
Connector, damaged
DURING ROUTINE MAINTENANCE VISIT, EVERY OTHER LIGHT FOR EMERGENCY FLOOR LIGHTING ON RIGHT SIDE WAS FOUND TO BE INOPERATIVE. LEFT REAR LIGHTING ALSO…
- 28 Apr 2002
Connector, disconnected
PHL- FLIGHT 3657 CREW REPORTED EMERGENCY FLOOR LIGHTING AFT SECTION LEFT SIDE AISLE INOPERATIVE AND WIRING LOOSE. MAINTENANCE RE-ATTACHED LEFT AFT SIDE…
- 18 Apr 2002
Connector, disconnected
DURING ROUTINE MAINTENANCE VISIT LEFT AFT FLOOR EMERGENCY LIGHTS WERE FOUND INOPERATIVE. LIGHT CONNECTION FOUND UNPLUGGED. CONNECTION PLUGGED IN. OPERATIONAL…
- 10 Apr 2002
Connector, loose
DURING ROUTINE MAINTENANCE VISIT LEFT SIDE OF CABIN EMERGENCY LIGHTS FOUND TO BE INOPERATIVE. FORWARD AND AFT PLUG CONNECTORS ON LEFT SIDE OF CABIN EMERGENCY…
- 8 Mar 2002
Light, inoperative
DURING ROUTINE MAINTENANCE VISIT, EMERGENCY FLOOR PATH LIGHTING FOUND TO BE INOPERATIVE. FLOOR TRACK LIGHT STRIP WAS REPLACED. AIRCRAFT RETURNED TO SERVICE.
- 24 Feb 2002
Engine, smoke
LGA FLIGHT#3829. CREW REPORTED BURNING ODOR LIKE A DUCT OVERHEAT. DUCT TEMP 20 DEGREES. FLIGHT ATTENDANT REPORTED A LIGHT HAZE IN CABIN. LEFT ENGINE WAS…
- 15 Jan 2002
Wire, broken
DURING ROUTINE MAINTENANCE VISIT EMERGENCY FLOOR LIGHT STRIP ON LEFT SIDE FORWARD SECTION AND PAX DOOR SIGN FOUND TO BE OUT. AFTER TROUBLESHOOTING FOUND…
- 20 Nov 2001
Connector, loose
DURING ROUTINE MAINTENANCE VISIT SEVERAL EMERGENCY LIGHTS IN FLOOR FOUND INOPERATIVE. CONNECTORS ON LEFT SEAT RAIL FOUND LOOSE AND WERE RESECURED. OPERATIONAL…
- 12 Nov 2001
Skin, cracked
DURING A CHECK INSPECTION LOWER FORWARD CORNER OPENING OF CARGO COMPARTMENT FOUND CRACKED. LOWER FORWARD COAMING SECTION OF CARGO DOOR OPENING REPLACED.…
- 28 Oct 2001
Light, inoperative
DURING ROUTINE MAINTENANCE VISIT SEVERAL FLOOR PATH EMERGENCY LIGHTS FOUND TO BE INOPERATIVE ON LEFT SIDE. NEW VISTA EMERGENCY LIGHT JUMPER INSTALLED AT SEATS…
- 19 Oct 2001
Link, worn
DURING FLEET INSPECTION OF NOSE GEAR FOR WEAR IN TRAILING ARM LINK ASSEMBLY, TRAILING ARM LINK AND PIN FOUND WORN. WORN PARTS REPLACED. LUBED AND SERVICED…
- 5 Oct 2001
Light, disconnected
DURING ROUTINE MAINTENANCE VISIT EMERGENCY FLOOR LIGHTING FOUND INOPERATIVE. SYSTEM TROUBLESHOT AND FOUND SEVERAL LIGHT STRIPS DISCONNECTED. LIGHT STRIPS…
- 18 Sep 2001
Connector, disconnected
MDT- DURING ROUTINE MAINTENANCE VISIT FLOOR LEVEL EMERGENCY LIGHTS ON LEFT AFT SIDE FOUND INOPERATIVE. AFT LEAD TO FLOOR LEVEL EMERGENCY LIGHTING FOUND…
- 28 Jul 2001
Frame, cracked
MDT- DURING C-INSPECTION FUSELAGE FRAME FOUND CRACKED AT STATION 354.250 JUST ABOVE OUTBOARD RIGHT SEAT RAIL AND JUST FORWARD OF RIGHT MID EMERGENCY EXIT.…
- 28 Jul 2001
Seat Track, corroded
MDT- DURING C-CHECK INSPECTION INBOARD LEFT FORWARD SEAT RAIL FOUND CORRODED. REPLACED WORN LT INBOARD CABIN SEAT RAIL SECTION, P/N 85320490-127, BETWEEN…
- 14 Jul 2001
Wire, broken
DURING ROUTINE MAINTENANCE VISIT 2 LIGHTS FOUND INOPERATIVE ON RIGHT SIDE OF EMERGENCY EXIT FLOOR PATH LIGHTING. BROKEN WIRE ON CONNECTOR RESOLDERED.…
- 14 Jun 2001
Light, inoperative
BOS-FLIGHT 3553. CREW REPORTED EMERGENCY EXIT LIGHTING 20 PERCENT INOPERATIVE. MAINTENANCE RECONNECTED FLOOR LIGHTING PLUG AT LEFT SIDE, REPLACED LIGHTING…
- 25 May 2001
Power Supply, inoperative
BGM- DURING ROUTINE MAINTENANCE VISIT AFT EMERGENCY LIGHTS WERE FOUND TO BE INOPERATIVE. MAINTENANCE REPLACED AFT POWER SUPPLY OPERATIONAL CHECK GOOD.…
- 4 Jan 2001
Jumper, broken
DURING ROUTINE MAINTENANCE VISIT, EMERGENCY FLOOR LIGHTING FOUND TO HAVE AN INOPERATIVE SEGMENT. ONE BROKEN JUMPER REPLACED, ANOTHER JUMPER WAS RESECURED.…
- 14 Dec 2000
Windshield, cracked
BOS-FLIGHT 3789.CREW DISCOVERED FIRST OFFICERS WINDSHIELD CRACKED. MAINTENANCE REMOVED AND REPLACED FIRST OFFICERS WINDSHIELD IN ACCORDANCE WITH DEHAVILLAND…
- 11 Apr 2000
Sensor, failed
FLT 3576: AFTER GEAR RETRACTION, THE NOSE GEAR RED UNSAFE LIGHT REMAINED ILLUMINATED. ALSO, THE RIGHT AMBER DOOR LIGHT REMAINED ILLUMINATED. MAINTENANCE…
- 4 Apr 2000
Audio Panel, failed
ERI-PIT - FLIGHT 3978 UPON APPROACH INTO PIT THE CREW OBSERVED SMOKE COMING FROM THE CAPTAINS AUDIO PANEL. AIRCRAFT LANDED WITHOUT INCIDENT. MAINTENANCE…
- 10 Apr 1999
Valve, failed
CLE-FLT 3775 - ON APPROACH INTO CLE, LANDING GEAR FAILED TO EXTEND WHEN SELECTED. GEAR INDICATED INTRANSIT. CREW PERFORMED SUCCESSFUL ALTERNATE GEAR EXTENSION…
- 17 Mar 1999
Pcu, malfunctioned
AFTER TAKEOFF FROM MDT, THE CREW EXPERIENCED A NR 2 ENGINE TORQUE FLUCTUATION ASSOCIATED WITH A PROPELLER RPM FLUCTUATION, OIL PRESSURE REMAINED NORMAL. THE…
- 3 Mar 1998
Connector, loose
LEFT FLOOR EMERGENCY PROXIMITY LIGHTING HAS SEVERAL LIGHTS INOPERATIVE. SECURED LOOSE PLUG AT AFT CABIN WIRING CIRCUIT. OPERATIONAL TEST NORMAL. A/C RETURNED…
- 21 Feb 1998
Bulb, failed
COCKPIT OVERHEAD PORTABLE EMERGENCY LIGHT IS INOPERATIVE. REMOVED AND REPLACED COCKPIT OVERHEAD PORTABLE EMERGENCY LIGHT BULB. OPERATIONAL TEST NORMAL.…
- 16 Feb 1998
Connector, loose
SEVERAL LIGHTS INOPERATIVE IN FLOOR EMERGENCY PROXIMITY LIGHTING SYSTEM. FOUND SEVERAL LIGHT STRIPS UNPLUGGED. SECURED CONNECTORS. OPERATIONAL TEST NORMAL.…
- 9 Feb 1998
Gauge, malfunctioned
ON CLIMB-OUT FROM SWF AFTER SELECTION OF GEAR UP, NR 2 OIL PSI LIGHT ILLUMINATED AND NR 2 OIL PSI GAUGE INDICATED 20 PSI, 5 SECONDS LATER, BOTH INDICATED…
- 21 Jan 1998
Light, inoperative
COCKPIT OVERHEAD PORTABLE EMERGENCY LIGHT DOES NOT ILLUMINATE. REMOVED AND REPLACED COCKPIT OVERHEAD PORTABLE EMERGENCY LIGHT ASSEMBLY WITH SERVICEABLE UNIT.…
- 7 Jan 1998
Bulb, failed
COCKPIT PORTABLE EMERGENCY LIGHT INOPERATIVE. REMOVED AND REPLACED BULB. OPERATIONAL TEST NORMAL. A/C RETURNED TO SERVICE. (M)
- 31 Dec 1997
Connectors, loose
EVERY OTHER LIGHT INOPERATIVE IN FLOOR EMERGENCY PROXIMITY LIGHTING SYSTEM. FOUND CONNECTORS LOOSE AT BOTH ENDS OF EMERGENCY LIGHTING STRIPS. REINSTALLED…
- 23 Dec 1997
Fuse, failed
LEFT LOWER CABIN EMERGENCY EXIT LIGHT INOPERATIVE. REPLACED FUSE IN FORWARD BATTERY PACK. OPERATIONAL TEST NORMAL. A/C RETURNED TO SERVICE. (M)
- 23 Dec 1997
Connector, loose
NUMEROUS FLOOR EMERGENCY LIGHTS INOPERATIVE. SECURED SEVERAL LOOSE AND CONNECTORS. OPERATIONAL TEST NORMAL. AIRCRAFT RETURNED TO SERVICE. (M)
- 22 Dec 1997
Oil Press Light, illuminated
DURING TAKEOFF FROM MDT, THE NR 2 ENGINE OIL PRESSURE LIGHT FLICKERED, THEN CAME ON FOR 1 SECOND. PRESSURE DROPPED TO 45 PSI FOR 2 TO 3 SECONDS,THEN RETURNED…
- 11 Dec 1997
Fuse, failed
SEVERAL EMERGENCY FLOOR PROXIMITY LIGHTS INOPERATIVE ON LEFT AND RIGHT SIDES OF CABN. FOUND BAD FUSE IN FORWARD BATTERY PACK. REMOVED AND REPLACED FUSE.…
- 2 Dec 1997
Connectors, loose
LEFT EMERGENCY EXIT DOOR LIGHT AND EVERY OTHER EMERGENCY FLOOR PROXIMITY LIGHT STRIP IS INOPERATIVE. FOUND SEVERAL JUMPERS UNPLUGGED AT FLOOR LEVEL LIGHTING…
- 13 Nov 1997
Wire, loose
EVERY OTHER BULB INOPERATIVE IN EMERGENCY FLOOR PROXIMITY LIGHTING SYSTEM. FOUND TWO JUMPER WIRES DISCONNECTED IN EMERGENCY FLOOR PROXIMITY LIGHTING CIRCUIT.…
- 8 Nov 1997
Light, inoperative
COCKPIT PORTABLE EMERGENCY LIGHT DOES NOT WORK WHEN EMERGENCY LIGHT SWITCH IS SELECTED TO ON. REMOVED AND REPLACED COCKPIT PORTABLE EMERGENCY LIGHT ASSEMBLY…
- 17 Aug 1997
Connector, loose
HALF OF THE EMERGENCY FLOOR LIGHTS INOP ON LEFT SIDE. RECONNECTED AFT FLOOR STRIP CONNECTOR. OPERATION CHECK GOOD. AIRCRAFT RETURNED TO SERVICE. (M)
- 17 Aug 1997
Light, inoperative
COCKPIT EMERGENCY LIGHT INOP. REMOVED AND REPLACED COCKPIT EMERGENCY LIGHT. OPERATION CHECK GOOD. AIRCRAFT RETURNED TO SERVICE. (M)
- 26 Jul 1997
Light, inoperative
RIGHT FORWARD EMERGENCY FLOOR PATH LIGHTING STRIP HAS ONE LIGHT INOPERATIVE. REMOVED AND REPLACED LIGHTING STRIP. OPERATIONAL CHECK NORMAL. AIRCRAFT RETURNED…
- 26 Jul 1997
Light, inoperative
LEFT CENTER AISLE EMERGENCY FLOOR PATH LIGHTING STRIP HAS ONE RED LIGHT INOPERATIVE. REMOVED AND REPLACED LIGHTING STRIP. OPERATIONAL CHECK NORMAL. AIRCRAFT…
- 23 Jul 1997
Connector, broken
AFT SECTION OF LEFT EMERGENCY FLOOR PATH LIGHTING INOPERATIVE. REPAIRED BROKEN CONNECTOR IN AFT LIGHTING SECTION AND REPLACED TWO FUSES IN FORWARD BATTERY…
- 3 Jul 1997
Battery Pack, discharged
ARMREST LEVEL EMERGENCY LIGHTS ON AIRSTAIR DOOR IN ROW 1A INOP. REMOVED AND REPLACED FORWARD BATTERY PACK. OPERATION CHECKS GOOD. AIRCRAFT RETURNED TO…
- 26 Jun 1997
Tube Assembly, failed
DURING CRUISE FLIGHT, THE NR 1 HYDRAULIC CONTENT DROPPED TO ZERO. A/C DIVERTED INTO PVD AND LANDED WITHOUT INCIDENT. MX FOUND THE HYDRAULIC LINE FROM THE NR 1…
- 10 Jan 1997
Oil Cooler, cracked
DURING CRUISE FLIGHT TO BOS, NR 2 ENGINE OIL PRESSURE WAS OBSERVED FLUCTUATING BETWEEN 40 AND 55 PSI. A/C DIVERTED INTO BGM AND LANDED WITHOUT INCIDENT.…
- 19 Aug 1996
Wire, loose
FOUND FLOOR EMERGENCY LIGHTS INOP ON LEFT SIDE, AFT OF ROW 6. REATTACHED WIRE CONNECTOR AT ROW 9, OPS CHECK GOOD. AIRCRAFT RETURNED TO SERVICE. (M)
- 14 Mar 1996
Lights, inoperative
RIGHT SIDE CABIN FLOOR EMERGENCY LIGHTS ARE INOP. REPLACED BATTERY PACK FUSES. LIGHTS OP CHECK NORMALLY. AIRCRAFT RETURNED TO SERVICE. (M)
- 5 Mar 1996
Cable Assy, shorted
AUTO FEATHER ARMED ADVISORY LIGHT FLICKERED ON AND OFF DURING CLIMB-OUT. FURTHER TESTING ON GROUND REVEALED NR 2 PROP WOULD NOT FEATHER. TROUBLESHOT AND FOUND…
- 10 Jan 1996
Hyd Pump, failed
UPON GEAR SELECTION DOWN, NR 2 ENGINE HYDRAULIC LIGHT ILLUMINATED, GEAR DID NOT OPERATE. CREW COMPLETED EMERGENCY CHECK LIST, GEAR OPERATED NORMALLY, SYSTEM…
- 23 May 1995
Actuator, frozen
AT HIGHER ALTITUDES, THE MISS TRIM NOSE DOWN LIGHT ILLUMINATED ON THE ADVISORY DISPLAY PANEL. COULD NOT MANUALLY MOVE THE ELEVATOR TRIM AND STANDBY ELEVATOR…
- 26 Apr 1995
Prox Switch, out of adjust
RT MAIN GEAR RED INDICATOR LIGHT AND GEAR HANDLE INDICATOR LIGHT FLASHED OFF AND ON INTERMITTENTLY. INSPECTED MLG SYSTEM AND PERFORMED PSEU TEST. NO FAULTS…
- 26 Feb 1995
Retract Mech, malfunctioned
WHILE SELECTING GEAR DOWN, NR 2 MAN HYDRAULIC PRESSURE WENT TO ZERO, NO GEAR EXTENDED AT THAT POINT. LOUD GRINDING NOISE WAS HEARD AFTER GEAR SELECTED DOWN,…
- 7 Feb 1995
Sequence Valve, failed
THE LT MAIN GEAR WOULD NOT RETRACT AFTER TAKEOFF, ACFT RETURNED TO FIELD. REMOVED AND REPLACED LT AFT GEAR DOOR ACTUATOR, AND MECHANICAL SEQUENCE VALVE IAW MM…
- 7 Feb 1995
Door Act, failed
THE LT MAIN GEAR WOULD NOT RETRACT AFTER TAKEOFF, ACFT RETURNED TO FIELD. REMOVED AND REPLACED LT AFT GEAR DOOR ACTUATOR, AND MECHANICAL SEQUENCE VALVE IAW MM…
- 18 Dec 1994
Hydraulic Pump, failed
UPON SELECTING GEAR DOWN, HYDRAULIC PRESSURE ON NR 2 MAIN AND STANDBY SYSTEMS WENT TO ZERO UNTIL GEAR WAS DOWN AND LOCKED. WITH GEAR DOWN AND LOCKED.…